PDN-LINK-FAULT-MGMT-MIB
AI MIB Summary
The PDN-LINK-FAULT-MGMT-MIB enables the configuration and monitoring of fault management parameters for primary and secondary Packet Data Network (PDN) links, specifically tracking link state transitions and failure conditions to facilitate automatic failover between redundant paths.
This management information module supports the objects to be used for fault management configuration on primary and secondary links.
Main OID:
pdnLinkFaultMgmtMIB.1.3.6.1.4.1.1795.2.24.2.40.1
17
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
17 total| Object Name |
|---|
pdnLinkFaultMgmtMIBThis management information module supports the objects
to be used for fault management configuration on primary
and secondary links. MODULE-IDENTITY .1.3.6.1.4.1.1795.2.24.2.40.1 |
pdnLinkFaultMgmtMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.40.1.1 |
pdnLinkFaultMgmtApsSelectionThis object is used to enable or disable the
Automatic Protection Switching (Aps) feature
on this device. This object can not be enabled
if the -Switchover due to link failures- is enabled.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.40.1.1.1 |
pdnLinkFaultMgmtSwitchoverSelectionThis object is used to enable or disable the
Switchover Due to link failures feature on
on this device. This object can not be enabled
if the APS feature is enabled.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.40.1.1.2 |
pdnLinkFailureConfigTableThis table contains one row per link
being monitored for link failures. SEQUENCE OF PdnLinkFailureConfigEntry .1.3.6.1.4.1.1795.2.24.2.40.1.1.3 |
pdnLinkFailureConfigEntryConfiguration information about a particular
interface being monitored for link failured. PdnLinkFailureConfigEntry .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1 |
pdnLinkFailureLOSPeriodBeforeSwitchingThis object allows users to configure the amount of
time a LOS condition shall exist on this uplink before
initiating a switchover.
Switchover due to LOS condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.1 |
pdnLinkFailureLOFPeriodBeforeSwitchingThis object allows users to configure the amount of
time a LOF condition shall exist on this uplink before
initiating a switchover.
Switchover due to LOF condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.2 |
pdnLinkFailureAISLPeriodBeforeSwitchingThis object allows users to configure the amount of
time a AIS-L condition shall exist on this uplink before
initiating a switchover.
Switchover due to AIS-L condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.3 |
pdnLinkFailureSdPeriodBeforeSwitchingThis object allows users to configure the amount of
time a Signal Degraded (Sd) condition shall exist on
this uplink before initiating a switchover.
Switchover due to Sd condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.4 |
pdnLinkFailureSfPeriodBeforeSwitchingThis object allows users to configure the amount of
time a Signal Failure Bit (Sf) condition shall exist on
this uplink before initiating a switchover.
Switchover due to Sf condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.5 |
pdnLinkFailureSdBerThresholdThis object allows users to configure the threshold
for the Signal Degrade Bit Error Rate (Sd).
The negated value of this number is used as the exponent
of 10 for computing the threshold value for the Bit Error
Rate (BER). For example, a value of 5 indicates a BER
threshold of 10^-5.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6 |
pdnLinkFailureSfBerThresholdThis object allows users to configure the threshold
for the Signal Failure Bit Error Rate (Sf).
The negated value of this number is used as the exponent
of 10 for computing the threshold value for the Bit Error
Rate (BER). For example, a value of 5 indicates a BER
threshold of 10^-5.rw Integer32 .1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.7 |
pdnDualLinkSelectionThis object is used to enable or disable the
ability to split traffic among dual links.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.40.1.1.4 |
pdnLinkFaultMgmtMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.40.1.2 |
pdnLinkFaultMgmtCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.40.1.2.1 |
pdnLinkFaultMgmtGroups OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.40.1.2.2 |