Home/Catalog/PDN-IF-EXT-CONFIG-MIB

PDN-IF-EXT-CONFIG-MIB

This Mib is created to facilitate configuration of interface related objects.
Main OID:
pdnIfExtEncapConfig.1.3.6.1.4.1.1795.2.24.2.6.12.3
13
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

13 total
Object Name
pdnIfXLinkConfigTableThis table contains configuration information for interfaces that are capable of switch roles at run-time.
SEQUENCE OF PdnIfXLinkConfigEntry
.1.3.6.1.4.1.1795.2.24.2.6.12.1.3
pdnIfXLinkConfigEntryAn entry in this table represents an interface that is capable of being used as an uplink. Typically, this table will contain entries only for interfaces that are capable of switching roles.
PdnIfXLinkConfigEntry
.1.3.6.1.4.1.1795.2.24.2.6.12.1.3.1
pdnIfXLinkConfigRoleThis object allows users to configure the role (e.g., uplink) intended for this interface.rw
PdnLinkRole
.1.3.6.1.4.1.1795.2.24.2.6.12.1.3.1.1
pdnIfExtEncapConfigThis Mib is created to facilitate configuration of interface related objects.
MODULE-IDENTITY
.1.3.6.1.4.1.1795.2.24.2.6.12.3
pdnIfMultiprotocolEncapConfigTableThis table that contains additional interface configuration information.
SEQUENCE OF PdnIfMultiprotocolEncapConfigEntry
.1.3.6.1.4.1.1795.2.24.2.6.12.3.1
pdnIfMultiprotocolEncapConfigEntryThere will be one of these rows for each interface that supports RFC1483.
PdnIfMultiprotocolEncapConfigEntry
.1.3.6.1.4.1.1795.2.24.2.6.12.3.1.1
pdnIfMultiprotocolEncapConfigIPRoutedPDUsIn the upstream direction user can configure the IP routed PDUs in the LLC SNAP encapsulation or VC Based Multiplexing encapsulation (RFC1483). If neither is configured 'none' is used. The direction is determined by the transmit direction. Initialy this object was developed for the endpoint use where the transmit direction is upstream. This object could be used for CO type equipment where the direction would be downstream.rw
Enumeration
.1.3.6.1.4.1.1795.2.24.2.6.12.3.1.1.1
pdnIfMultiprotocolEncapConfigBridgedPDUsIn the transmit direction user can configure the IP routed PDUs in the LLC SNAP encapsulation or VC Based Multiplexing encapsulation (RFC1483). If neither is configured 'none' is used.rw
Enumeration
.1.3.6.1.4.1.1795.2.24.2.6.12.3.1.1.2
pdnIfMultiprotocolEncapMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1795.2.24.2.6.12.3.2
pdnIfMultiprotocolEncapMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1795.2.24.2.6.12.3.2.1
pdnIfMultiprotocolEncapCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.1795.2.24.2.6.12.3.2.2
pdnIfXConfigMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1795.2.24.2.6.12.4
pdnIfXConfigMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1795.2.24.2.6.12.4.1
PDN-IF-EXT-CONFIG-MIB - SNMP MIB Reference | MIBs Explorer