PDN-DS1EXT-MIB
The Paradyne enterprise DS1/G.703 extension MIB. This MIB provides additional DS1 and G.703 (E1) configuration objects not provided by rfc2495.
Main OID:
pdnDs1Ext.1.3.6.1.4.1.1795.2.24.2.6.5.5
15
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
15 total| Object Name |
|---|
pdnDs1ExtThe Paradyne enterprise DS1/G.703 extension MIB. This MIB provides additional DS1 and G.703 (E1) configuration objects not provided by rfc2495. MODULE-IDENTITY .1.3.6.1.4.1.1795.2.24.2.6.5.5 |
pdnDs1ExtObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.6.5.5.1 |
pdnDs1ExtConfTableThe Paradyne DS1/G.703 extension configuration table. This table is used for configuring extensions to DS1 and G.703 interfaces. SEQUENCE OF PdnDs1ExtConfEntry .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1 |
pdnDs1ExtConfEntryAn entry in the Paradyne DS1/G.703 extension configuration table. Note: The objects used depend on the type of interface. For DS1: use pdnDs1ExtConfLineLengthType and one of (pdnDs1ExtConfLineLength or pdnDs1ExtConfLineBuildOut) For G.703: use pdnDs1ExtConfLineLengthType and pdnDs1ExtConfConnector PdnDs1ExtConfEntry .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1 |
pdnDs1ExtConfLineLengthTypeThis entry specifies the type of loop length for the interface. short-haul is intended for intra-building use. long-haul is intended for inter-building use.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.1 |
pdnDs1ExtConfLineLengthThis entry specifies the loop length, in feet, for a short-haul DS1 line. This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineBuildOut object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.2 |
pdnDs1ExtConfLineBuildOutThis entry specifies the line build out, in decibels, for a long-haul DS1 line. dB0Pnt0 = 0.0 dB dB7Pnt5 = -7.5 dB dB15Pnt0 = -15.0 dB dB22Pnt5 = -22.5 dB This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineLength object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.3 |
pdnDs1ExtConfConnectorThis entry specifies the type of connector to be used. This object only applies to G.703 interfaces. bnc: 75-Ohm connector supporting only short-haul. rj48: 120-Ohm connector supporting both short-haul and long-haul.rw Enumeration .1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.4 |
pdnDs1ExtConformance OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.6.5.5.2 |
pdnDs1ExtGroups OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1 |
pdnDs1ExtT1ConfigGroupA collection of configuration objects required for configuring a T1 interface. Unknown .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.1 |
pdnDs1ExtE1ConfigGroupA collection of configuration objects required for configuring a G.703 (E1) interface. Unknown .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.2 |
pdnDs1ExtCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2 |
pdnDs1ExtComplianceCompliance statement for using this MIB for configuring DS1 interfaces. Unknown .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.1 |
pdnDs1ExtG703ComplianceCompliance statement for using this MIB for configuring G.703 interfaces. Unknown .1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.2 |