Home/Catalog/OPTIX-SDH-PER-MIB

OPTIX-SDH-PER-MIB

This module MIB describes the Optix Perfomance.
Main OID:
optixPerformance.1.3.6.1.4.1.2011.2.25.3.10.20
166
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

166 total
Object Name
optixPerformanceThis module MIB describes the Optix Perfomance.
MODULE-IDENTITY
.1.3.6.1.4.1.2011.2.25.3.10.20
perMonitorTime
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.10
per15mMonitorTime
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.10.10
per15mMonitorStartTimeStart date and time of 15 minutes PM period.When system enter the per15mMonitorStartTime,15 minutes PM starts.the per15mMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,15 minutes PM starts immediately.reset the per15mMonitorStartTime will terminate current 15 minutes PM period.When system enter the per15mMonitorEndTime, the per15mMonitorStartTime will be reset to zero.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.10.10.10
per15mMonitorEndTimeEnd date and time of 15 minutes PM period.you need set the per15mMonitorStartTime before set the per15mMonitorEndTime,and per15mMonitorStartTime should earlier than the per15mMonitorEndTime,specially,when the per15mMonitorEndTime is equal to 1990-00-00 00:00:00,15 minutes PM ends immediately. When system enter the per15mMonitorEndTime,the per15mMonitorEndTime will be reset to zero.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.10.10.20
per24hMonitorTime
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.10.20
per24hMonitorStartTimeStart date and time of one day PM period.When system enter the per24hMonitorStartTime,one day PM starts.the per24hMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,one day PM starts immediately.reset the per24hMonitorStartTime will terminate current one day PM period.When system enter the per24hMonitorEndTime, the per24hMonitorStartTime will be reset to zero.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.10.20.10
per24hMonitorEndTimeEnd date and time of one day PM period.you need set the per24hMonitorStartTime before set the per24hMonitorEndTime,and per24hMonitorStartTime should earlier than the per24hMonitorEndTime,specially,when the per24hMonitorEndTime is equal to 1990-00-00 00:00:00,one day PM ends immediately. When system enter the per24hMonitorEndTime,the per24hMonitorEndTime will be reset to zero.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.10.20.20
perMonitorData
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.20
per15mMonitoring
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10
per15mCurrentDataTable15 minutes PM period current data table
SEQUENCE OF Per15mCurrentDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10
per15mCurrentDataEntry15 minutes PM period current data entry
Per15mCurrentDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1
per15mCurrentDataBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.1
per15mCurrentDataOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.2
per15mCurrentDataPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.3
per15mCurrentDataEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.4
per15mCurrentDataStartTimestart date and time: start date and time of current 15 minutes PM period.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.5
per15mCurrentDataValueCurrent data value: value of current 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.6
per15mCurrentDataResetCurrent data reset: reset value of current 15 minutes PM period register to zero.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.7
per15mHistoryDataTable15 minutes PM period historic data table
SEQUENCE OF Per15mHistoryDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20
per15mHistoryDataEntry15 minutes PM period historic data entry
Per15mHistoryDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1
per15mHistoryDataBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.1
per15mHistoryDataOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.2
per15mHistoryDataPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.3
per15mHistoryDataEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.4
per15mHistoryDataStartTimestart date and time: start date and time of special 15 minutes PM period.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.5
per15mHistoryDataValueHistoric data value: value of special 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.6
per15mHistoryDataResetHistoric data reset: reset value of special 15 minutes PM period register to zero.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.7
per24hMonitoring
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20
per24hCurrentDataTableone day PM period current data table
SEQUENCE OF Per24hCurrentDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10
per24hCurrentDataEntryone day PM period current data entry
Per24hCurrentDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1
per24hCurrentDataBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.1
per24hCurrentDataOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.2
per24hCurrentDataPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.3
per24hCurrentDataEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.4
per24hCurrentDataStartTimestart date and time: start date and time of current one day PM period.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.5
per24hCurrentDataValueCurrent data value: value of current one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.6
per24hCurrentDataResetCurrent data reset: reset value of current one day PM period register to zero.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.7
per24hHistoryDataTableone day PM period historic data table
SEQUENCE OF Per24hHistoryDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20
per24hHistoryDataEntryone day PM period historic data entry
Per24hHistoryDataEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1
per24hHistoryDataBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.1
per24hHistoryDataOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.2
per24hHistoryDataPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.3
per24hHistoryDataEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.4
per24hHistoryDataStartTimestart date and time: start date and time of special one day PM period.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.5
per24hHistoryDataValueHistoric data value: value of special one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.6
per24hHistoryDataResetHistoric data reset: reset value of special one day PM period register to zero.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.7
perThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.30
per15mThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10
per15mThresholdTable15 minutes PM period threshold table
SEQUENCE OF Per15mThresholdEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10
per15mThresholdEntry15 minutes PM period threshold entry
Per15mThresholdEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1
per15mThresholdBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.1
per15mThresholdOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.2
per15mThresholdPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.3
per15mThresholdEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.4
per15mThresholdHighValueHigh threshold value: some parameters have two thresholds,such as RSBBE, while others have single threshold,such as RSSES.rw
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.5
per15mThresholdLowValueLow threshold value: specially,some parameters have single threshold, so their Low threshold should always be zero.rw
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.6
per15mThresholdResetThreshold reset: reset both high threshold and low threshold(if has).rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.7
per24hThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20
per24hThresholdTableone day PM period threshold table
SEQUENCE OF Per24hThresholdEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10
per24hThresholdEntryone day PM period threshold entry
Per24hThresholdEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1
per24hThresholdBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.1
per24hThresholdOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.2
per24hThresholdPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.3
per24hThresholdEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.4
per24hThresholdValueThreshold value: all parameters have only one threshold value for one day PM period.rw
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.5
per24hThresholdResetThreshold reset: reset threshold.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.6
perStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.40
perStatusControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10
per15mStatusControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10
per15mMonitorStatusTable15 minutes PM period monitor status table.
SEQUENCE OF Per15mMonitorStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10
per15mMonitorStatusEntry15 minutes PM period monitor status entry.
Per15mMonitorStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1
per15mMonitorStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.1
per15mMonitorStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.2
per15mMonitorStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.3
per15mMonitorStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.4
per15mMonitorStatusMonitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled. The default monitor status is enable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.5
per15mPauseStatusTable15 minutes PM period pause status table.
SEQUENCE OF Per15mPauseStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20
per15mPauseStatusEntry15 minutes PM period pause status entry.
Per15mPauseStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1
per15mPauseStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.1
per15mPauseStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.2
per15mPauseStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.3
per15mPauseStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.4
per15mPauseStatusPause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.5
per15mThresholdStatusTable15 minutes PM period threshold status table
SEQUENCE OF Per15mThresholdStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30
per15mThresholdStatusEntry15 minutes PM period threshold status entry
Per15mThresholdStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1
per15mThresholdStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.1
per15mThresholdStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.2
per15mThresholdStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.3
per15mThresholdStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.4
per15mThresholdStatusThreshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.5
per15mAutoReportStatusTable15 minutes PM period automatic report(REP) status table
SEQUENCE OF Per15mAutoReportStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40
per15mAutoReportStatusEntry15 minutes PM period automatic report(REP) status entry
Per15mAutoReportStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1
per15mAutoReportStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.1
per15mAutoReportStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.2
per15mAutoReportStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.3
per15mAutoReportStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.4
per15mAutoReportStatusAutomatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable .rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.5
per24hStatusControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20
per24hMonitorStatusTableone day PM period monitor status table.
SEQUENCE OF Per24hMonitorStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10
per24hMonitorStatusEntryone day PM period monitor status entry.
Per24hMonitorStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1
per24hMonitorStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.1
per24hMonitorStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.2
per24hMonitorStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.3
per24hMonitorStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.4
per24hMonitorStatusMonitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled.The default monitor status is enable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.5
per24hPauseStatusTableone day PM period pause status table.
SEQUENCE OF Per24hPauseStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20
per24hPauseStatusEntryone day PM period pause status entry.
Per24hPauseStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1
per24hPauseStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.1
per24hPauseStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.2
per24hPauseStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.3
per24hPauseStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.4
per24hPauseStatusPause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.5
per24hThresholdStatusTableone day PM period threshold status table.
SEQUENCE OF Per24hThresholdStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30
per24hThresholdStatusEntryone day PM period threshold status entry.
Per24hThresholdStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1
per24hThresholdStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.1
per24hThresholdStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.2
per24hThresholdStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.3
per24hThresholdStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.4
per24hThresholdStatusThreshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable.rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.5
per24hAutoReportStatusTableone day PM period automatic report(REP) status table.
SEQUENCE OF Per24hAutoReportStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40
per24hAutoReportStatusEntryone day PM period automatic report(REP) status entry.
Per24hAutoReportStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1
per24hAutoReportStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.1
per24hAutoReportStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.2
per24hAutoReportStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.3
per24hAutoReportStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.4
per24hAutoReportStatusAutomatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable .rw
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.5
perThresholdCrossStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20
per15mThresholdCrossStatusTable15 minutes PM period threshold crossing status table.
SEQUENCE OF Per15mThresholdCrossStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10
per15mThresholdCrossStatusEntry15 minutes PM period threshold crossing status entry.
Per15mThresholdCrossStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1
per15mThresholdCrossStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.1
per15mThresholdCrossStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.2
per15mThresholdCrossStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.3
per15mThresholdCrossStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.4
per15mThresholdCrossStatusThreshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed.ro
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.5
per24hThresholdCrossStatusTableone day PM period threshold crossing status table.
SEQUENCE OF Per24hThresholdCrossStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20
per24hThresholdCrossStatusEntryone day PM period threshold crossing status entry.
Per24hThresholdCrossStatusEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1
per24hThresholdCrossStatusBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.1
per24hThresholdCrossStatusOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.2
per24hThresholdCrossStatusPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.3
per24hThresholdCrossStatusEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.4
per24hThresholdCrossStatusThreshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed.ro
Enumeration
.1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.5
perEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.50
perUATEvent
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10
perUATEventTableUAT event table.
SEQUENCE OF PerUATEventEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10
perUATEventEntryUAT event entry.
PerUATEventEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1
perUATBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.1
perUATOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.2
perUATPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.3
perUATEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.4
perUATStartTimethe date and time when enter UAT.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.5
perUATEndTimethe date and time when exit UAT.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.6
perCSESEvent
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20
perCSESEventTableCSES event table.
SEQUENCE OF PerCSESEventEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10
perCSESEventEntryCSES event entry.
PerCSESEventEntry
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1
perCSESBoardNoCard No.:between 1 and 20ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.1
perCSESOpticalPortOptical port No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.2
perCSESPathNumberPath No.:values depend on type of cardro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.3
perCSESEventIDEvent ID:values depend on type of cardro
SdhPerformanceEventType (OPTIX-SDH-TC-MIB)
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.4
perCSESStartTimethe date and time when enter CSES.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.5
perCSESKeepTimethe count of CSES continues.ro
Gauge32
.1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.6
optixCommonSdhConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.90
optixCommonSdhGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.90.1
currentObjectGroupEnter the description of the created OBJECT-GROUP.
Unknown
.1.3.6.1.4.1.2011.2.25.3.10.20.90.1.1
optixCommonSdhCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.2.25.3.10.20.90.2
optixCommonSdhbasicComplianceEnter the description of the created MODULE-COMPLIANCE.
Unknown
.1.3.6.1.4.1.2011.2.25.3.10.20.90.2.1