LUM-OA-MIB
AI MIB Summary
The LUM-OA-MIB module enables monitoring and configuration of optical amplifier interfaces within Lumentum optical transport equipment, exposing performance metrics such as input/output optical power, gain levels, pump laser currents, and alarm states for amplifier health assessment.
The optical amplifier interface MIB.
- General
- Amplifier interfaces
Main OID:
lumOaMIBModule.1.3.6.1.4.1.8708.1.1.20
174
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
174 total| Object Name |
|---|
lumOaMIBModuleThe optical amplifier interface MIB.
- General
- Amplifier interfaces MODULE-IDENTITY .1.3.6.1.4.1.8708.1.1.20 |
lumOaConfs OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.1 |
lumOaGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.1.1 |
lumOaCompl OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.1.2 |
lumOaMinimalGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.1.3 |
lumOaMinimalCompl OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.1.4 |
lumOaMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2 |
oaGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.1 |
oaGeneralLastChangeTimeThe time when the configuration of the MIB
was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.1.1 |
oaGeneralStateLastChangeTimeThe time when the state of the MIB was last
changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.1.2 |
oaGeneralOaIfTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.19.2.1.3 |
oaGeneralVoaIfTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.19.2.1.4 |
oaGeneralVoaClientIfTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.19.2.1.5 |
oaGeneralVoaLineIfTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.19.2.1.6 |
oaGeneralOaModuleTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.19.2.1.7 |
oaIfList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.2 |
oaIfTableThe interface list. SEQUENCE OF OaIfEntry .1.3.6.1.4.1.8708.2.19.2.2.1 |
oaIfEntryAn entry in the interface list. OaIfEntry .1.3.6.1.4.1.8708.2.19.2.2.1.1 |
oaIfIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.1 |
oaIfNameThe management name of the interface, for
example 'oa:1:2:1-2', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
oa:s:s:p - Optical amplifier interfacero MgmtNameString .1.3.6.1.4.1.8708.2.19.2.2.1.1.2 |
oaIfDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.2.1.1.3 |
oaIfSubrackThe number of the subrack where the interface
is located.rw SubrackNumber .1.3.6.1.4.1.8708.2.19.2.2.1.1.4 |
oaIfSlotThe number of the slot where the interface is
located.rw SlotNumber .1.3.6.1.4.1.8708.2.19.2.2.1.1.5 |
oaIfTxPortThe number of the port where the TX-side of the
interface is located.rw PortNumber .1.3.6.1.4.1.8708.2.19.2.2.1.1.6 |
oaIfRxPortThe number of the port where the RX-side of
the interface is located.rw PortNumber .1.3.6.1.4.1.8708.2.19.2.2.1.1.7 |
oaIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.8 |
oaIfAdminStatusThe administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
This attribute can be written via SNMP.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.9 |
oaIfOperStatusThe operational state for the interface.
notPresent - The physical resources are not
available.
down - The interface is de-activated or the are
faults preventing it from going to the 'up'-state.
up - The interface is operational.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.10 |
oaIfLaserStatusThe operational state of the laser.
off - The laser is turned off.
on - The laser is turned on.ro Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.11 |
oaIfAmplifierTypeThe type of amplifier for this interface.
preAmp25GAd - pre-amplifier for 2.5 G,
add-drop
preAmp25GTm - pre-amplifier for 2.5 G,
terminal multiplexor
powAmp10G - power amplifier for 10 G
preAmp10GAd - pre-amplifier for 10 G,
add-drop
preAmp10GTm - pre-amplifier for 10 G,
terminal multiplexor
constantGain - used for pre-amps and other
point-to-point links. Uses ASE compensation.
=> specify wantedGain
constantGainLI - Default value. Works as constantGain
but uses low input power mode. Please,
refer to OA commissioning manual to decideoaIfRxSignalStatus
which gain mode that should be used.
constantGainHI - Works as constantGain but uses high
input power mode. Please, refer to OA
commissioning manual to decide which gain
mode that should be used.
constantSignalPower - used in combination
with 2 channel add-drop filters.
Uses ASE compensation.
=> specify wantedSignalPower
constantPower - For test purposes
No ASE compensation.
=> specify wantedAbsolutePowerrw Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.12 |
oaIfWantedAbsolutePowerLevelFor powAmp10G and constantPower, the
user can give the wanted absolute power level
in units of 0.1 dBm.
For OA10 and OA17 in constantGain and
constantSignalPower, this parameter shows the
derived absolute power level. The value is
calculated from the other given parameters.rw Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.13 |
oaIfWantedRelativePowerLevelWanted offset from production setting in units
of 0.1 dBm.
Applicable for preAmp25GAd and preAmp10GAd.
Note that the output power level is dependent on
the power of the input signal, so you might not
always get the power that you want.rw Integer32 (-60..60) .1.3.6.1.4.1.8708.2.19.2.2.1.1.14 |
oaIfWantedGainSignal gain setting in units of 0.1 dB.
Applicable for preAmp25GTm, preAmp10GTm
and constantGain/LI/HI.
This attribute can be written via SNMP.rw Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.15 |
oaIfFrequencyMinLowest amplified freqency in hundreds of
GHz (0.01 GHz).
Supported range 19210 ... 19590 (c921 .. c959)rw LambdaFrequency .1.3.6.1.4.1.8708.2.19.2.2.1.1.16 |
oaIfFrequencyMaxHighest amplified freqency in hundreds of
GHz (0.01 GHz).
Supported range 19210 ... 19590 (c921 .. c959)rw LambdaFrequency .1.3.6.1.4.1.8708.2.19.2.2.1.1.17 |
oaIfNominalTxPowerThe production setting for output power in
units of 0.1 dBm.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.18 |
oaIfTxPowerLevelThe transmitted power level in units of 0.1 dBm.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.19 |
oaIfRxPowerLevelThe received power level in units of 0.1 dBm.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.20 |
oaIfRxPowerLevelLowThresholdThe lower threshold for received power level
relative to the loss of signal threshold,
in units of 0.1 dB.rw Integer32 (-50..80) .1.3.6.1.4.1.8708.2.19.2.2.1.1.21 |
oaIfLaserBiasMeasures laser bias current value in tenths of
mA (0.1 mA).ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.22 |
oaIfNominalLaserTempThe pre-set laser temperature (0.1 deg C)ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.23 |
oaIfRelativeLaserTempThe current offset from the pre-set temperature
in units of 0.1 degrees centigrade.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.24 |
oaIfLossOfSignalThresholdThe threshold for loss of signal.
Note: Depending on the type of optical amplifier
the value range may vary.rw Integer32 (-560..80) .1.3.6.1.4.1.8708.2.19.2.2.1.1.25 |
oaIfLossOfSignalLoss of signal.
Applicable for all signal formats.
A(ctivation): Active loss of signal HW
indication.
D(e-activation): Inactive loss of signal HW
indication.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.26 |
oaIfPumpLaserTempHighPump laser temperature too high.
A(ctivation): Temperature exceedes threshold.
D(e-activation): Temperature below threshold
again.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.27 |
oaIfRegulationProblemRxPowerHighThe input power is above meassuring range.
A: The received power level exceeds the
associated threshold.
D: The received power level is 0.5 dBm below
the threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.28 |
oaIfRegulationProblemTxPowerHighThe output power is above meassuring range.
A: The received power level exceeds the
associated threshold.
D: The received power level is 0.5 dBm below
the threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.29 |
oaIfRegulationProblemTxPowerLowThe output power is below meassuring range.
A: The transmitted power level below the associated
threshold.
D: The transmitted power level is 0.5 dBm above the
threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.30 |
oaIfReceivedPowerLowReceived power level low threshold exceeded.
A: The received power level is below the
associated threshold.
D: The received power level is 0.5 dBm above the
threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.31 |
oaIfLaserBiasHighLaser bias high threshold exceeded.
A: The laser bias current exceeds the associated
threshold.
D: The laser bias current is 0.5 mA below the
associated threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.32 |
oaIfLaserTempControlFaultThe pump laser temperature exceeds the
associated threshold.
A: The temperature exceeds the value.
D: The temperature is below the value.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.33 |
oaIfHwMissingThe HW for this i/f is not present
A: Wrong HW is inserted in subrack.
D: Correct HW is inserted in subrack.rodeprecated FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.34 |
oaIfConfigurationCommandSelect which amplifier type to use. All modes are not applicable
for all type of amplifier boards.
constantGain: Amplifier will set output power according to
the input power and the given gain
constantSignalPower: Amplifier will set a constant output power
with noise-compensation
constantPower: Amplifier will set a constant output power
independent of input power
constantGainLI: Amplifier will work with constant gain in the low
input power region (-35 to -5 dBm)
constantGainHI: Amplifier will work with constant gain in the
high input power region (-25 to +8 dBm)
pow10: Power amplifier for 10G
pre10ad: Pre-amplifier for 10G in add/drop config.
pre25ad: Pre-amplifier for 2.5G in add/drop config.
pre10tm: Pre-amplifier for 10G in TM configuration
pre25tm: Pre-amplifier for 2.5G in TM configurationro CommandString .1.3.6.1.4.1.8708.2.19.2.2.1.1.35 |
oaIfPumpLaserTempLowPump laser temperature too low.
A(ctivation): Temperature exceedes threshold.
D(e-activation): Temperature above threshold
again.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.36 |
oaIfLaserTempLowRelativeThresholdThreshold for the Laser Temp Low alarm, expressed
as an offset from a pre-set nominal temperature,
in units of 0.1 degrees centigrade.rw Integer32 (-100..150) .1.3.6.1.4.1.8708.2.19.2.2.1.1.37 |
oaIfLaserTempHighRelativeThresholdThreshold for the Laser Temp High alarm, expressed
as an offset from a pre-set nominal temperature,
in units of 0.1 degrees centigrade.rw Integer32 (-250..450) .1.3.6.1.4.1.8708.2.19.2.2.1.1.38 |
oaIfAmpTypeNotSupportedByHwThe HW revision does not support
the selected amplifier type.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.39 |
oaIfWantedSignalPowerLevelWanted offset from production setting in units
of 0.1 dBm.
Applicable for preAmp25GAd and preAmp10GAd.
Note that the output power level is dependent on
the power of the input signal, so you might not
always get the power that you want.rw Integer32 (-150..-50) .1.3.6.1.4.1.8708.2.19.2.2.1.1.40 |
oaIfObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.19.2.2.1.1.41 |
oaIfLaserForcedOnWhen enabled, the laser control is on regardless of
whether there is an input signal present or not.
disabled - the laser control is activated first
after input signal is detected
enabled - the laser control is always onrw Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.42 |
oaIfActualLaserTempThe current laser temperature
in units of 0.1 degrees centigrade.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.43 |
oaIfAutomaticPowerShutdownWhen enabled, the laser is turned off if
the input signal to the other gain block
is lost.
disabled - the laser is NOT affected by
the other gain block.
enabled - the laser is turned off if
the input to the other gain block
is lost.rw Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.44 |
oaIfDisabledThe interface is disabled.
A: Interface disabled.
D: Interface enabled.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.45 |
oaIfWantedPowerLimitApplicable for constantGainLI/HI.
Sets the maximum allowed output power.
This attribute can be written via SNMP.rw Integer32 (-70..195) .1.3.6.1.4.1.8708.2.19.2.2.1.1.46 |
oaIfModuleInfoInformation (for example firmware and serial number) about
the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.2.1.1.47 |
oaIfMonitorInsertionLossThe insertion loss for the monitor port.
When the real insertion loss is not possible
to read from unit (older HW revsions), 20
(default) dB will be shown which is the
normal value.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.2.1.1.48 |
oaIfNumMonitorInsertionLossThis is the same parameter as Monitor Port
Insertion Loss. The difference is that you
will not see if the value can be read from
the port or not (if not 20 dB will be shown).ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.49 |
oaIfFunctionalTypeThe functional type of amplifier. This attribute is ONLY used
by TNM and the traffic is not affected if changed.
undefined - default
preAmp - pre-amplifier. Receiving amplifier on a
terminal node.
offLinePreAmp - offline pre-amplifier. Receiving amplifier
in a non-terminal node. Offline pre-amplifier
amplifies dropped traffic, NOT line traffic.
lineAmp - line amplifier. Amplifier situated between
the terminal nodes, which amplifies passing
line traffic and (if applicable) added
traffic.
booster - booster. The transmitting amplifier from a
terminal node.rw Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.50 |
oaIfActualGainActual measured gain in units of 0.1 dB.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.51 |
oaIfSaturationFaultSaturation alarm threshold is passed. Actual Gain < (Wanted
Gain -1 dB). The alarm can be cleared be cleared by reducing
the wanted gain attribute.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.52 |
oaIfWantedGainTiltSettable gain tilt for variable gain OA in units of 0.1 dB.
Positive gain tilt is defined as gain increasing wavelength.
Negative gain tilt is defined as gain decreasing wavelength.rw Integer32 (-20..20) .1.3.6.1.4.1.8708.2.19.2.2.1.1.53 |
oaIfTxPowerLevelLowThresholdThe lower threshold for transmitted power level
transmits to the loss of signal threshold,
in units of 0.1 dB.rw Integer32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.54 |
oaIfLaserPumpBiasMeasures laser pump bias current in
per cent (%) of max value.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.2.1.1.55 |
oaIfCaseTempOutOfrangeThe module has shutdown automatically because of
too high case temp (>85 degC) or too low case
temp (-40 degC).
A(ctivation): Case temperature exceedes pre-set
temp range.
D(e-activation): Case temperature within pre-set
temp range again.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.56 |
oaIfLaserTempOutOfRangethe module has shutdown automatically because of
pump laser temp out of range (15-35 degC).
A(ctivation): Laser temperature exceedes pre-set value.
D(e-activation): Laser temperature below pre-set value
again.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.57 |
oaIfSupportsReadMonitorInsertionLossThis value tells whether a OA interface has the ability
to read the insertion loss value for the monitor port on
an interface.
true: Insertion loss can be read for this interface
false: Insertion loss cannot be read for this interfacero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.2.1.1.58 |
oaIfTxSignalStatusThe operational state for outgoing (TX) signal
of the interface.
down - A fault that would lead to a protection
switch has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.
notApplicable (2147483647) - Attribute is not used on board.ro Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.59 |
oaIfRxSignalStatusThe operational state for incoming (RX) signal
of the interface.
down - A major fault has occurred
degraded - The signal quality is impaired.
up - The signal is OK.
notApplicable (2147483647) - Attribute is not used on boardro Enumeration .1.3.6.1.4.1.8708.2.19.2.2.1.1.60 |
oaIfOutputPowerFailOutput power failed alarm threshold is passed. Actual Gain < (Wanted
Gain -1 dB) and Output Power < (Power Limit -1 dB).ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.2.1.1.61 |
lumentisOaNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.3 |
oaVoaIfList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.4 |
oaVoaIfTableThe interface list. SEQUENCE OF OaVoaIfEntry .1.3.6.1.4.1.8708.2.19.2.4.1 |
oaVoaIfEntryAn entry in the interface list. OaVoaIfEntry .1.3.6.1.4.1.8708.2.19.2.4.1.1 |
oaVoaIfIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.1 |
oaVoaIfNameThe management name of the interface,
for example 'voa:1:2:1'.ro MgmtNameString .1.3.6.1.4.1.8708.2.19.2.4.1.1.2 |
oaVoaIfDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.4.1.1.3 |
oaVoaIfSubrackThe number of the subrack where the interface
is located.ro SubrackNumber .1.3.6.1.4.1.8708.2.19.2.4.1.1.4 |
oaVoaIfSlotThe number of the slot where the interface is
located.ro SlotNumber .1.3.6.1.4.1.8708.2.19.2.4.1.1.5 |
oaVoaIfTxPortThe number of the port where the TX part of
the interface is located.ro PortNumber .1.3.6.1.4.1.8708.2.19.2.4.1.1.6 |
oaVoaIfRxPortThe number of the port where the RX part of
the interface is located.ro PortNumber .1.3.6.1.4.1.8708.2.19.2.4.1.1.7 |
oaVoaIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.8 |
oaVoaIfAdminStatusThe administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
Note that there is no difference between 'up'
and 'service', if no alarms can be rasied from
this object.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
This attribute can be written via SNMP.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.19.2.4.1.1.9 |
oaVoaIfOperStatusThe operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.19.2.4.1.1.10 |
oaVoaIfObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.19.2.4.1.1.11 |
oaVoaIfControlModeThe control mode of the VOA channel.
constPower - regulate slowly towards a given
output power.
constAttenuation - set a fix attenuation
constPowerAtInstallation -
like constPower but allow faster changes
(this mode is not released)rw Enumeration .1.3.6.1.4.1.8708.2.19.2.4.1.1.12 |
oaVoaIfWantedOutputPowerThe wanted output power.
Applicable for constPower.rw Integer32 (-300..170) .1.3.6.1.4.1.8708.2.19.2.4.1.1.13 |
oaVoaIfCurrentOutputPowerThe actual output power.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.14 |
oaVoaIfRegulationRangeAn offset below the wanted output power
at which the 'Current Power Out Of Range'
alarm shall be raised.
When the current output power is so
far below the wanted output power,
the regulation stops and the alarm
is raised.
Applicable for constPower.rw Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.15 |
oaVoaIfWantedAttenuationThe wanted attenuation.
voa8ch: applicable for constAttenuation
voa2ch: always applicable
This attribute can be written via SNMP.rw Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.16 |
oaVoaIfCurrentAttenuationThe current attenuation.
Applicable for constPower.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.17 |
oaVoaIfSamplePeriodThe approximate period between 2
consecutive measurements of the output
powerro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.4.1.1.18 |
oaVoaIfOuputPowerControlFailureAlarm raised when the wanted output power
can not be obtained. That is, even if the
attenuation is reduced to zero, the wanted
power can not be obtained.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.4.1.1.19 |
oaVoaIfCurrentPowerOutOfRangeAlarm raised when the current output power
is outside the 'regulation range'.
The regulation range is defined by
Wanted Output Power +/- Regulation Range
At this point, no regulation will be performed.
The operator must change the wantedOutputPower.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.4.1.1.20 |
oaVoaIfConfigurationCommandSelect which control mode to use:
constPower
constAttenuationro CommandString .1.3.6.1.4.1.8708.2.19.2.4.1.1.21 |
oaVoaIfInInstallationModeAlarm raised when the VOA is put in the
mode constPowerAtInstallation.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.4.1.1.22 |
oaVoaClientIfList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.5 |
oaVoaClientIfTableThe interface list. SEQUENCE OF OaVoaClientIfEntry .1.3.6.1.4.1.8708.2.19.2.5.1 |
oaVoaClientIfEntryAn entry in the interface list. OaVoaClientIfEntry .1.3.6.1.4.1.8708.2.19.2.5.1.1 |
oaVoaClientIfIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.1 |
oaVoaClientIfNameThe management name of the interface,
for example 'voaClient:1:2:1' which
indicates subrack 1, board 2 and port 1.ro MgmtNameString .1.3.6.1.4.1.8708.2.19.2.5.1.1.2 |
oaVoaClientIfDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.5.1.1.3 |
oaVoaClientIfSubrackThe number of the subrack where the interface
is located.ro SubrackNumber .1.3.6.1.4.1.8708.2.19.2.5.1.1.4 |
oaVoaClientIfSlotThe number of the slot where the interface is
located.ro SlotNumber .1.3.6.1.4.1.8708.2.19.2.5.1.1.5 |
oaVoaClientIfTxPortThe number of the port where the Tx part of
the interface is located.ro PortNumber .1.3.6.1.4.1.8708.2.19.2.5.1.1.6 |
oaVoaClientIfRxPortThe number of the port where the Rx part of
the interface is located.ro PortNumber .1.3.6.1.4.1.8708.2.19.2.5.1.1.7 |
oaVoaClientIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.8 |
oaVoaClientIfAdminStatusThe administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.9 |
oaVoaClientIfOperStatusThe operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.10 |
oaVoaClientIfObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.19.2.5.1.1.11 |
oaVoaClientIfControlModeThe control mode of the VOA channel.
constAttenuation - set a fix attenuationrw Enumeration .1.3.6.1.4.1.8708.2.19.2.5.1.1.12 |
oaVoaClientIfWantedAttenuationThe wanted attenuation.
Applicable for constAttenuation
This attribute can be written via SNMP if not set to 2147483647.rw Unsigned32 (0..200|2147483647) .1.3.6.1.4.1.8708.2.19.2.5.1.1.13 |
oaVoaClientIfCurrentAttenuationThe current attenuation.
Applicable in case of MDU40 boards.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.14 |
oaVoaClientIfLambdaThe frequency given in hundreds of GHz
(0.01 GHz). Set to 0 for transparent ports.ro LambdaFrequency .1.3.6.1.4.1.8708.2.19.2.5.1.1.15 |
oaVoaClientIfAbsoluteAttenuationThe wanted absolute attenuation including
the insertion loss. This value can never be
set below the upper limit of the insertion loss.
VOA8CHSFP: The range is dependent on the
inserted VOA SFP.
This attribute can be written via SNMP.rw Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.16 |
oaVoaClientIfVoa2CurrentAttenuationThis value shows the current set absolute attenua-
tion on VOA8ch-II and voa8chsfp. This value is
usually the same value as the absolute attenuation
except when a decrase or increase of attenuation is
ongoing or when administrative status is set to down.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.17 |
oaVoaClientIfDecreaseAttenuationThe wanted decrease of the current attenuation.
This attribute can be written via SNMP.rw Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.18 |
oaVoaClientIfIncreaseAttenuationThe wanted increase of the current attenuation.
This attribute can be written via SNMP.rw Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.19 |
oaVoaClientIfInsertionLossThe insertion loss for the port. The attenuation
can never be set to a value below this value.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.5.1.1.20 |
oaVoaClientIfExpectedFrequencyThe frequency given in hundreds of GHz
(0.01 GHz). This value is only used for
presentation purposes in name of port.rw LambdaFrequency .1.3.6.1.4.1.8708.2.19.2.5.1.1.21 |
oaVoaClientIfSfpMissingAn expected VOA SFP is missing.
A(ctivation): An expected SFP is missing.
D(e-activation): The missing SFP is inserted.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.22 |
oaVoaClientIfSfpClassString that contains general information about
the SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.5.1.1.23 |
oaVoaClientIfSfpTransmitterFailedThe SFP has detected a failure
in the transmitter part.
A(ctivation): The transmitter has failed
D(e-activation): The transmitter is OK againro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.24 |
oaVoaClientIfSfpMediaMismatchThe type of the inserted SFP is not the expected one.
A(ctivation): Invalid or mismatching SFP media is
detected.
D(e-activation): The correct SFP is used.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.25 |
oaVoaClientIfLossOfSignalLoss of signal.
A(ctivation): Active loss of signal HW
indication.
D(e-activation): Inactive loss of signal HW
indication.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.26 |
oaVoaClientIfSfpCodeMismatchThe inserted SFP does not have a legal
manufacturer code.
A(ctivation): A SFP with illegal code is inserted.
D(e-activation): The SFP with illegal code is removed.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.27 |
oaVoaClientIfAttenuationConfigMismatchThe wanted attenuation is not supported by the
inserted SFP.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.5.1.1.28 |
oaVoaLineIfList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.6 |
oaVoaLineIfTableThe interface list. SEQUENCE OF OaVoaLineIfEntry .1.3.6.1.4.1.8708.2.19.2.6.1 |
oaVoaLineIfEntryAn entry in the interface list. OaVoaLineIfEntry .1.3.6.1.4.1.8708.2.19.2.6.1.1 |
oaVoaLineIfIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.6.1.1.1 |
oaVoaLineIfNameThe management name of the interface, for
example 'VoaLine:1:2:1-2', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
oaVoaLine:s:s:p - line interfacero MgmtNameString .1.3.6.1.4.1.8708.2.19.2.6.1.1.2 |
oaVoaLineIfDescrUser configurable label.
This attribute can be written via SNMP.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.6.1.1.3 |
oaVoaLineIfSubrackThe number of the subrack where the interface
is located.rw SubrackNumber .1.3.6.1.4.1.8708.2.19.2.6.1.1.4 |
oaVoaLineIfSlotThe number of the slot where the interface is
located.rw SlotNumber .1.3.6.1.4.1.8708.2.19.2.6.1.1.5 |
oaVoaLineIfTxPortThe number of the port where the TX-side of the
interface is located.rw PortNumber .1.3.6.1.4.1.8708.2.19.2.6.1.1.6 |
oaVoaLineIfRxPortThe number of the port where the RX-side of
the interface is located.rw PortNumber .1.3.6.1.4.1.8708.2.19.2.6.1.1.7 |
oaVoaLineIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.6.1.1.8 |
oaVoaLineIfAdminStatusThe administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.19.2.6.1.1.9 |
oaVoaLineIfOperStatusThe operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.19.2.6.1.1.10 |
oaVoaLineIfModuleFailureThe module HW has detected a failure.
A: The module has failed
D: The module is OK againro FaultStatus .1.3.6.1.4.1.8708.2.19.2.6.1.1.11 |
oaVoaLineIfObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.19.2.6.1.1.12 |
oaModuleList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.19.2.7 |
oaModuleTableThe module list. SEQUENCE OF OaModuleEntry .1.3.6.1.4.1.8708.2.19.2.7.1 |
oaModuleEntryAn entry in the module list. OaModuleEntry .1.3.6.1.4.1.8708.2.19.2.7.1.1 |
oaModuleIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.7.1.1.1 |
oaModuleNameThe management name of the interface,
for example 'module:1:2:1'.ro MgmtNameString .1.3.6.1.4.1.8708.2.19.2.7.1.1.2 |
oaModuleDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.7.1.1.3 |
oaModuleSubrackThe number of the subrack where the module
is located.ro SubrackNumber .1.3.6.1.4.1.8708.2.19.2.7.1.1.4 |
oaModuleSlotThe number of the slot where the module is
located.ro SlotNumber .1.3.6.1.4.1.8708.2.19.2.7.1.1.5 |
oaModuleNumberThe number of the module on the board.ro PortNumber .1.3.6.1.4.1.8708.2.19.2.7.1.1.6 |
oaModuleInvPhysIndexOrZeroThe row in the invPhysTable for this interface.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.19.2.7.1.1.7 |
oaModuleAdminStatusThe administrative state for the module.
up - Alarms are not suppressed.
service - Alarms from the module are suppressed.
The module is still activated.
down - Currently not used.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.8 |
oaModuleOperStatusThe operational state for the module.
notPresent - The module is not available.
down - The module is not used.
up - The module is active.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.9 |
oaModuleObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.19.2.7.1.1.10 |
oaModuleNominalTempThe set temperature in units of 0.1 degrees centigrade.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.7.1.1.11 |
oaModuleRelativeTempThe relative temperature in units of 0.1 degrees centigrade.ro Integer32 .1.3.6.1.4.1.8708.2.19.2.7.1.1.12 |
oaModuleTempFailureThe module temperature is above/below expected one.
A: The temperature is not correct.
D: The temperature becomes correct.ro FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.13 |
oaModuleTemperatureThe temperature of the module in 0.1 degrees
centigradero Integer32 .1.3.6.1.4.1.8708.2.19.2.7.1.1.14 |
oaModuleCommunicationFailureThe communication with the module failed.
A(ctivation): Failed to talk to the module
D(e-activation): Could talk to the module againro FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.15 |
oaModuleModuleInfoInformation (for example firmware and serial number) about the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.19.2.7.1.1.16 |
oaModuleVcomThresholdExceededThe common voltage supply in the ROADM module has exceeded
recommended threshold. Firmware upgrade is recommended to resolve this alarm.
A(ctivation): The VCOM threshold is exceeded
D(e-activation): The VCOM threshold is OK againrodeprecated FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.17 |
oaModuleFirmwareUpgradeAvailableAn upgrade is available for the ROADM module. See release
notes for details on how to obtain and install the upgradero FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.18 |
oaModuleWarmingUpROADM module is warming up, the optics has not reached a stable
temperature, all channels are blocked.
A(ctivation): cold start of ROADM board
D(e-activation): the warning is cleared as soon as the module
has reached a stable temperature, this takes 3-8 minutesro FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.19 |
oaModuleFailureThe module HW has detected a failure.
A(ctivation): The module has failed
D(e-activation): The module is OK againro FaultStatus .1.3.6.1.4.1.8708.2.19.2.7.1.1.20 |