The LUM-OA-MIB module enables monitoring and configuration of optical amplifier interfaces within Lumentum optical transport equipment, exposing performance metrics such as input/output optical power, gain levels, pump laser currents, and alarm states for amplifier health assessment.

The optical amplifier interface MIB. - General - Amplifier interfaces
Main OID:
lumOaMIBModule.1.3.6.1.4.1.8708.1.1.20
174
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

174 total
Object Name
lumOaMIBModuleThe optical amplifier interface MIB. - General - Amplifier interfaces
MODULE-IDENTITY
.1.3.6.1.4.1.8708.1.1.20
lumOaConfs
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.1
lumOaGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.1.1
lumOaCompl
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.1.2
lumOaMinimalGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.1.3
lumOaMinimalCompl
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.1.4
lumOaMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2
oaGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.1
oaGeneralLastChangeTimeThe time when the configuration of the MIB was last changed.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.1.1
oaGeneralStateLastChangeTimeThe time when the state of the MIB was last changed.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.1.2
oaGeneralOaIfTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.1.3
oaGeneralVoaIfTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.1.4
oaGeneralVoaClientIfTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.1.5
oaGeneralVoaLineIfTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.1.6
oaGeneralOaModuleTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.1.7
oaIfList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.2
oaIfTableThe interface list.
SEQUENCE OF OaIfEntry
.1.3.6.1.4.1.8708.2.19.2.2.1
oaIfEntryAn entry in the interface list.
OaIfEntry
.1.3.6.1.4.1.8708.2.19.2.2.1.1
oaIfIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.1
oaIfNameThe management name of the interface, for example 'oa:1:2:1-2', where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: oa:s:s:p - Optical amplifier interfacero
MgmtNameString
.1.3.6.1.4.1.8708.2.19.2.2.1.1.2
oaIfDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.3
oaIfSubrackThe number of the subrack where the interface is located.rw
SubrackNumber
.1.3.6.1.4.1.8708.2.19.2.2.1.1.4
oaIfSlotThe number of the slot where the interface is located.rw
SlotNumber
.1.3.6.1.4.1.8708.2.19.2.2.1.1.5
oaIfTxPortThe number of the port where the TX-side of the interface is located.rw
PortNumber
.1.3.6.1.4.1.8708.2.19.2.2.1.1.6
oaIfRxPortThe number of the port where the RX-side of the interface is located.rw
PortNumber
.1.3.6.1.4.1.8708.2.19.2.2.1.1.7
oaIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.8
oaIfAdminStatusThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The interface should be activated when it becomes available. Alarms are not suppressed. This attribute can be written via SNMP.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.9
oaIfOperStatusThe operational state for the interface. notPresent - The physical resources are not available. down - The interface is de-activated or the are faults preventing it from going to the 'up'-state. up - The interface is operational.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.10
oaIfLaserStatusThe operational state of the laser. off - The laser is turned off. on - The laser is turned on.ro
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.11
oaIfAmplifierTypeThe type of amplifier for this interface. preAmp25GAd - pre-amplifier for 2.5 G, add-drop preAmp25GTm - pre-amplifier for 2.5 G, terminal multiplexor powAmp10G - power amplifier for 10 G preAmp10GAd - pre-amplifier for 10 G, add-drop preAmp10GTm - pre-amplifier for 10 G, terminal multiplexor constantGain - used for pre-amps and other point-to-point links. Uses ASE compensation. => specify wantedGain constantGainLI - Default value. Works as constantGain but uses low input power mode. Please, refer to OA commissioning manual to decideoaIfRxSignalStatus which gain mode that should be used. constantGainHI - Works as constantGain but uses high input power mode. Please, refer to OA commissioning manual to decide which gain mode that should be used. constantSignalPower - used in combination with 2 channel add-drop filters. Uses ASE compensation. => specify wantedSignalPower constantPower - For test purposes No ASE compensation. => specify wantedAbsolutePowerrw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.12
oaIfWantedAbsolutePowerLevelFor powAmp10G and constantPower, the user can give the wanted absolute power level in units of 0.1 dBm. For OA10 and OA17 in constantGain and constantSignalPower, this parameter shows the derived absolute power level. The value is calculated from the other given parameters.rw
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.13
oaIfWantedRelativePowerLevelWanted offset from production setting in units of 0.1 dBm. Applicable for preAmp25GAd and preAmp10GAd. Note that the output power level is dependent on the power of the input signal, so you might not always get the power that you want.rw
Integer32 (-60..60)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.14
oaIfWantedGainSignal gain setting in units of 0.1 dB. Applicable for preAmp25GTm, preAmp10GTm and constantGain/LI/HI. This attribute can be written via SNMP.rw
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.15
oaIfFrequencyMinLowest amplified freqency in hundreds of GHz (0.01 GHz). Supported range 19210 ... 19590 (c921 .. c959)rw
LambdaFrequency
.1.3.6.1.4.1.8708.2.19.2.2.1.1.16
oaIfFrequencyMaxHighest amplified freqency in hundreds of GHz (0.01 GHz). Supported range 19210 ... 19590 (c921 .. c959)rw
LambdaFrequency
.1.3.6.1.4.1.8708.2.19.2.2.1.1.17
oaIfNominalTxPowerThe production setting for output power in units of 0.1 dBm.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.18
oaIfTxPowerLevelThe transmitted power level in units of 0.1 dBm.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.19
oaIfRxPowerLevelThe received power level in units of 0.1 dBm.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.20
oaIfRxPowerLevelLowThresholdThe lower threshold for received power level relative to the loss of signal threshold, in units of 0.1 dB.rw
Integer32 (-50..80)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.21
oaIfLaserBiasMeasures laser bias current value in tenths of mA (0.1 mA).ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.22
oaIfNominalLaserTempThe pre-set laser temperature (0.1 deg C)ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.23
oaIfRelativeLaserTempThe current offset from the pre-set temperature in units of 0.1 degrees centigrade.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.24
oaIfLossOfSignalThresholdThe threshold for loss of signal. Note: Depending on the type of optical amplifier the value range may vary.rw
Integer32 (-560..80)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.25
oaIfLossOfSignalLoss of signal. Applicable for all signal formats. A(ctivation): Active loss of signal HW indication. D(e-activation): Inactive loss of signal HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.26
oaIfPumpLaserTempHighPump laser temperature too high. A(ctivation): Temperature exceedes threshold. D(e-activation): Temperature below threshold again.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.27
oaIfRegulationProblemRxPowerHighThe input power is above meassuring range. A: The received power level exceeds the associated threshold. D: The received power level is 0.5 dBm below the threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.28
oaIfRegulationProblemTxPowerHighThe output power is above meassuring range. A: The received power level exceeds the associated threshold. D: The received power level is 0.5 dBm below the threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.29
oaIfRegulationProblemTxPowerLowThe output power is below meassuring range. A: The transmitted power level below the associated threshold. D: The transmitted power level is 0.5 dBm above the threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.30
oaIfReceivedPowerLowReceived power level low threshold exceeded. A: The received power level is below the associated threshold. D: The received power level is 0.5 dBm above the threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.31
oaIfLaserBiasHighLaser bias high threshold exceeded. A: The laser bias current exceeds the associated threshold. D: The laser bias current is 0.5 mA below the associated threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.32
oaIfLaserTempControlFaultThe pump laser temperature exceeds the associated threshold. A: The temperature exceeds the value. D: The temperature is below the value.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.33
oaIfHwMissingThe HW for this i/f is not present A: Wrong HW is inserted in subrack. D: Correct HW is inserted in subrack.rodeprecated
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.34
oaIfConfigurationCommandSelect which amplifier type to use. All modes are not applicable for all type of amplifier boards. constantGain: Amplifier will set output power according to the input power and the given gain constantSignalPower: Amplifier will set a constant output power with noise-compensation constantPower: Amplifier will set a constant output power independent of input power constantGainLI: Amplifier will work with constant gain in the low input power region (-35 to -5 dBm) constantGainHI: Amplifier will work with constant gain in the high input power region (-25 to +8 dBm) pow10: Power amplifier for 10G pre10ad: Pre-amplifier for 10G in add/drop config. pre25ad: Pre-amplifier for 2.5G in add/drop config. pre10tm: Pre-amplifier for 10G in TM configuration pre25tm: Pre-amplifier for 2.5G in TM configurationro
CommandString
.1.3.6.1.4.1.8708.2.19.2.2.1.1.35
oaIfPumpLaserTempLowPump laser temperature too low. A(ctivation): Temperature exceedes threshold. D(e-activation): Temperature above threshold again.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.36
oaIfLaserTempLowRelativeThresholdThreshold for the Laser Temp Low alarm, expressed as an offset from a pre-set nominal temperature, in units of 0.1 degrees centigrade.rw
Integer32 (-100..150)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.37
oaIfLaserTempHighRelativeThresholdThreshold for the Laser Temp High alarm, expressed as an offset from a pre-set nominal temperature, in units of 0.1 degrees centigrade.rw
Integer32 (-250..450)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.38
oaIfAmpTypeNotSupportedByHwThe HW revision does not support the selected amplifier type.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.39
oaIfWantedSignalPowerLevelWanted offset from production setting in units of 0.1 dBm. Applicable for preAmp25GAd and preAmp10GAd. Note that the output power level is dependent on the power of the input signal, so you might not always get the power that you want.rw
Integer32 (-150..-50)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.40
oaIfObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.19.2.2.1.1.41
oaIfLaserForcedOnWhen enabled, the laser control is on regardless of whether there is an input signal present or not. disabled - the laser control is activated first after input signal is detected enabled - the laser control is always onrw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.42
oaIfActualLaserTempThe current laser temperature in units of 0.1 degrees centigrade.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.43
oaIfAutomaticPowerShutdownWhen enabled, the laser is turned off if the input signal to the other gain block is lost. disabled - the laser is NOT affected by the other gain block. enabled - the laser is turned off if the input to the other gain block is lost.rw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.44
oaIfDisabledThe interface is disabled. A: Interface disabled. D: Interface enabled.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.45
oaIfWantedPowerLimitApplicable for constantGainLI/HI. Sets the maximum allowed output power. This attribute can be written via SNMP.rw
Integer32 (-70..195)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.46
oaIfModuleInfoInformation (for example firmware and serial number) about the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.47
oaIfMonitorInsertionLossThe insertion loss for the monitor port. When the real insertion loss is not possible to read from unit (older HW revsions), 20 (default) dB will be shown which is the normal value.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.48
oaIfNumMonitorInsertionLossThis is the same parameter as Monitor Port Insertion Loss. The difference is that you will not see if the value can be read from the port or not (if not 20 dB will be shown).ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.49
oaIfFunctionalTypeThe functional type of amplifier. This attribute is ONLY used by TNM and the traffic is not affected if changed. undefined - default preAmp - pre-amplifier. Receiving amplifier on a terminal node. offLinePreAmp - offline pre-amplifier. Receiving amplifier in a non-terminal node. Offline pre-amplifier amplifies dropped traffic, NOT line traffic. lineAmp - line amplifier. Amplifier situated between the terminal nodes, which amplifies passing line traffic and (if applicable) added traffic. booster - booster. The transmitting amplifier from a terminal node.rw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.50
oaIfActualGainActual measured gain in units of 0.1 dB.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.51
oaIfSaturationFaultSaturation alarm threshold is passed. Actual Gain < (Wanted Gain -1 dB). The alarm can be cleared be cleared by reducing the wanted gain attribute.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.52
oaIfWantedGainTiltSettable gain tilt for variable gain OA in units of 0.1 dB. Positive gain tilt is defined as gain increasing wavelength. Negative gain tilt is defined as gain decreasing wavelength.rw
Integer32 (-20..20)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.53
oaIfTxPowerLevelLowThresholdThe lower threshold for transmitted power level transmits to the loss of signal threshold, in units of 0.1 dB.rw
Integer32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.54
oaIfLaserPumpBiasMeasures laser pump bias current in per cent (%) of max value.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.2.1.1.55
oaIfCaseTempOutOfrangeThe module has shutdown automatically because of too high case temp (>85 degC) or too low case temp (-40 degC). A(ctivation): Case temperature exceedes pre-set temp range. D(e-activation): Case temperature within pre-set temp range again.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.56
oaIfLaserTempOutOfRangethe module has shutdown automatically because of pump laser temp out of range (15-35 degC). A(ctivation): Laser temperature exceedes pre-set value. D(e-activation): Laser temperature below pre-set value again.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.57
oaIfSupportsReadMonitorInsertionLossThis value tells whether a OA interface has the ability to read the insertion loss value for the monitor port on an interface. true: Insertion loss can be read for this interface false: Insertion loss cannot be read for this interfacero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.2.1.1.58
oaIfTxSignalStatusThe operational state for outgoing (TX) signal of the interface. down - A fault that would lead to a protection switch has occurred. degraded - The signal quality is impaired. up - The signal is OK. notApplicable (2147483647) - Attribute is not used on board.ro
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.59
oaIfRxSignalStatusThe operational state for incoming (RX) signal of the interface. down - A major fault has occurred degraded - The signal quality is impaired. up - The signal is OK. notApplicable (2147483647) - Attribute is not used on boardro
Enumeration
.1.3.6.1.4.1.8708.2.19.2.2.1.1.60
oaIfOutputPowerFailOutput power failed alarm threshold is passed. Actual Gain < (Wanted Gain -1 dB) and Output Power < (Power Limit -1 dB).ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.2.1.1.61
lumentisOaNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.3
oaVoaIfList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.4
oaVoaIfTableThe interface list.
SEQUENCE OF OaVoaIfEntry
.1.3.6.1.4.1.8708.2.19.2.4.1
oaVoaIfEntryAn entry in the interface list.
OaVoaIfEntry
.1.3.6.1.4.1.8708.2.19.2.4.1.1
oaVoaIfIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.1
oaVoaIfNameThe management name of the interface, for example 'voa:1:2:1'.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.19.2.4.1.1.2
oaVoaIfDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.4.1.1.3
oaVoaIfSubrackThe number of the subrack where the interface is located.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.19.2.4.1.1.4
oaVoaIfSlotThe number of the slot where the interface is located.ro
SlotNumber
.1.3.6.1.4.1.8708.2.19.2.4.1.1.5
oaVoaIfTxPortThe number of the port where the TX part of the interface is located.ro
PortNumber
.1.3.6.1.4.1.8708.2.19.2.4.1.1.6
oaVoaIfRxPortThe number of the port where the RX part of the interface is located.ro
PortNumber
.1.3.6.1.4.1.8708.2.19.2.4.1.1.7
oaVoaIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.8
oaVoaIfAdminStatusThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. Note that there is no difference between 'up' and 'service', if no alarms can be rasied from this object. up - The interface should be activated when it becomes available. Alarms are not suppressed. This attribute can be written via SNMP.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.19.2.4.1.1.9
oaVoaIfOperStatusThe operational state for the interface. notPresent - The interface is not available. down - The interface is not used. up - The interface is active.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.19.2.4.1.1.10
oaVoaIfObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.19.2.4.1.1.11
oaVoaIfControlModeThe control mode of the VOA channel. constPower - regulate slowly towards a given output power. constAttenuation - set a fix attenuation constPowerAtInstallation - like constPower but allow faster changes (this mode is not released)rw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.4.1.1.12
oaVoaIfWantedOutputPowerThe wanted output power. Applicable for constPower.rw
Integer32 (-300..170)
.1.3.6.1.4.1.8708.2.19.2.4.1.1.13
oaVoaIfCurrentOutputPowerThe actual output power.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.14
oaVoaIfRegulationRangeAn offset below the wanted output power at which the 'Current Power Out Of Range' alarm shall be raised. When the current output power is so far below the wanted output power, the regulation stops and the alarm is raised. Applicable for constPower.rw
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.15
oaVoaIfWantedAttenuationThe wanted attenuation. voa8ch: applicable for constAttenuation voa2ch: always applicable This attribute can be written via SNMP.rw
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.16
oaVoaIfCurrentAttenuationThe current attenuation. Applicable for constPower.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.17
oaVoaIfSamplePeriodThe approximate period between 2 consecutive measurements of the output powerro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.4.1.1.18
oaVoaIfOuputPowerControlFailureAlarm raised when the wanted output power can not be obtained. That is, even if the attenuation is reduced to zero, the wanted power can not be obtained.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.4.1.1.19
oaVoaIfCurrentPowerOutOfRangeAlarm raised when the current output power is outside the 'regulation range'. The regulation range is defined by Wanted Output Power +/- Regulation Range At this point, no regulation will be performed. The operator must change the wantedOutputPower.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.4.1.1.20
oaVoaIfConfigurationCommandSelect which control mode to use: constPower constAttenuationro
CommandString
.1.3.6.1.4.1.8708.2.19.2.4.1.1.21
oaVoaIfInInstallationModeAlarm raised when the VOA is put in the mode constPowerAtInstallation.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.4.1.1.22
oaVoaClientIfList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.5
oaVoaClientIfTableThe interface list.
SEQUENCE OF OaVoaClientIfEntry
.1.3.6.1.4.1.8708.2.19.2.5.1
oaVoaClientIfEntryAn entry in the interface list.
OaVoaClientIfEntry
.1.3.6.1.4.1.8708.2.19.2.5.1.1
oaVoaClientIfIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.1
oaVoaClientIfNameThe management name of the interface, for example 'voaClient:1:2:1' which indicates subrack 1, board 2 and port 1.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.19.2.5.1.1.2
oaVoaClientIfDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.5.1.1.3
oaVoaClientIfSubrackThe number of the subrack where the interface is located.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.19.2.5.1.1.4
oaVoaClientIfSlotThe number of the slot where the interface is located.ro
SlotNumber
.1.3.6.1.4.1.8708.2.19.2.5.1.1.5
oaVoaClientIfTxPortThe number of the port where the Tx part of the interface is located.ro
PortNumber
.1.3.6.1.4.1.8708.2.19.2.5.1.1.6
oaVoaClientIfRxPortThe number of the port where the Rx part of the interface is located.ro
PortNumber
.1.3.6.1.4.1.8708.2.19.2.5.1.1.7
oaVoaClientIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.8
oaVoaClientIfAdminStatusThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The interface should be activated when it becomes available. Alarms are not suppressed.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.9
oaVoaClientIfOperStatusThe operational state for the interface. notPresent - The interface is not available. down - The interface is not used. up - The interface is active.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.10
oaVoaClientIfObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.19.2.5.1.1.11
oaVoaClientIfControlModeThe control mode of the VOA channel. constAttenuation - set a fix attenuationrw
Enumeration
.1.3.6.1.4.1.8708.2.19.2.5.1.1.12
oaVoaClientIfWantedAttenuationThe wanted attenuation. Applicable for constAttenuation This attribute can be written via SNMP if not set to 2147483647.rw
Unsigned32 (0..200|2147483647)
.1.3.6.1.4.1.8708.2.19.2.5.1.1.13
oaVoaClientIfCurrentAttenuationThe current attenuation. Applicable in case of MDU40 boards.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.14
oaVoaClientIfLambdaThe frequency given in hundreds of GHz (0.01 GHz). Set to 0 for transparent ports.ro
LambdaFrequency
.1.3.6.1.4.1.8708.2.19.2.5.1.1.15
oaVoaClientIfAbsoluteAttenuationThe wanted absolute attenuation including the insertion loss. This value can never be set below the upper limit of the insertion loss. VOA8CHSFP: The range is dependent on the inserted VOA SFP. This attribute can be written via SNMP.rw
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.16
oaVoaClientIfVoa2CurrentAttenuationThis value shows the current set absolute attenua- tion on VOA8ch-II and voa8chsfp. This value is usually the same value as the absolute attenuation except when a decrase or increase of attenuation is ongoing or when administrative status is set to down.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.17
oaVoaClientIfDecreaseAttenuationThe wanted decrease of the current attenuation. This attribute can be written via SNMP.rw
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.18
oaVoaClientIfIncreaseAttenuationThe wanted increase of the current attenuation. This attribute can be written via SNMP.rw
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.19
oaVoaClientIfInsertionLossThe insertion loss for the port. The attenuation can never be set to a value below this value.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.5.1.1.20
oaVoaClientIfExpectedFrequencyThe frequency given in hundreds of GHz (0.01 GHz). This value is only used for presentation purposes in name of port.rw
LambdaFrequency
.1.3.6.1.4.1.8708.2.19.2.5.1.1.21
oaVoaClientIfSfpMissingAn expected VOA SFP is missing. A(ctivation): An expected SFP is missing. D(e-activation): The missing SFP is inserted.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.22
oaVoaClientIfSfpClassString that contains general information about the SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.5.1.1.23
oaVoaClientIfSfpTransmitterFailedThe SFP has detected a failure in the transmitter part. A(ctivation): The transmitter has failed D(e-activation): The transmitter is OK againro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.24
oaVoaClientIfSfpMediaMismatchThe type of the inserted SFP is not the expected one. A(ctivation): Invalid or mismatching SFP media is detected. D(e-activation): The correct SFP is used.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.25
oaVoaClientIfLossOfSignalLoss of signal. A(ctivation): Active loss of signal HW indication. D(e-activation): Inactive loss of signal HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.26
oaVoaClientIfSfpCodeMismatchThe inserted SFP does not have a legal manufacturer code. A(ctivation): A SFP with illegal code is inserted. D(e-activation): The SFP with illegal code is removed.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.27
oaVoaClientIfAttenuationConfigMismatchThe wanted attenuation is not supported by the inserted SFP.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.5.1.1.28
oaVoaLineIfList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.6
oaVoaLineIfTableThe interface list.
SEQUENCE OF OaVoaLineIfEntry
.1.3.6.1.4.1.8708.2.19.2.6.1
oaVoaLineIfEntryAn entry in the interface list.
OaVoaLineIfEntry
.1.3.6.1.4.1.8708.2.19.2.6.1.1
oaVoaLineIfIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.6.1.1.1
oaVoaLineIfNameThe management name of the interface, for example 'VoaLine:1:2:1-2', where the first number indicates sub-rack, the second slot number and the third is the port number. Examples: oaVoaLine:s:s:p - line interfacero
MgmtNameString
.1.3.6.1.4.1.8708.2.19.2.6.1.1.2
oaVoaLineIfDescrUser configurable label. This attribute can be written via SNMP.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.6.1.1.3
oaVoaLineIfSubrackThe number of the subrack where the interface is located.rw
SubrackNumber
.1.3.6.1.4.1.8708.2.19.2.6.1.1.4
oaVoaLineIfSlotThe number of the slot where the interface is located.rw
SlotNumber
.1.3.6.1.4.1.8708.2.19.2.6.1.1.5
oaVoaLineIfTxPortThe number of the port where the TX-side of the interface is located.rw
PortNumber
.1.3.6.1.4.1.8708.2.19.2.6.1.1.6
oaVoaLineIfRxPortThe number of the port where the RX-side of the interface is located.rw
PortNumber
.1.3.6.1.4.1.8708.2.19.2.6.1.1.7
oaVoaLineIfInvPhysIndexOrZeroThe row in the invPhysTable for this interface. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.6.1.1.8
oaVoaLineIfAdminStatusThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The interface should be activated when it becomes available. Alarms are not suppressed.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.19.2.6.1.1.9
oaVoaLineIfOperStatusThe operational state for the interface. notPresent - The interface is not available. down - The interface is not used. up - The interface is active.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.19.2.6.1.1.10
oaVoaLineIfModuleFailureThe module HW has detected a failure. A: The module has failed D: The module is OK againro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.6.1.1.11
oaVoaLineIfObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.19.2.6.1.1.12
oaModuleList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.19.2.7
oaModuleTableThe module list.
SEQUENCE OF OaModuleEntry
.1.3.6.1.4.1.8708.2.19.2.7.1
oaModuleEntryAn entry in the module list.
OaModuleEntry
.1.3.6.1.4.1.8708.2.19.2.7.1.1
oaModuleIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.7.1.1.1
oaModuleNameThe management name of the interface, for example 'module:1:2:1'.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.19.2.7.1.1.2
oaModuleDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.7.1.1.3
oaModuleSubrackThe number of the subrack where the module is located.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.19.2.7.1.1.4
oaModuleSlotThe number of the slot where the module is located.ro
SlotNumber
.1.3.6.1.4.1.8708.2.19.2.7.1.1.5
oaModuleNumberThe number of the module on the board.ro
PortNumber
.1.3.6.1.4.1.8708.2.19.2.7.1.1.6
oaModuleInvPhysIndexOrZeroThe row in the invPhysTable for this interface. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.19.2.7.1.1.7
oaModuleAdminStatusThe administrative state for the module. up - Alarms are not suppressed. service - Alarms from the module are suppressed. The module is still activated. down - Currently not used.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.8
oaModuleOperStatusThe operational state for the module. notPresent - The module is not available. down - The module is not used. up - The module is active.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.9
oaModuleObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.19.2.7.1.1.10
oaModuleNominalTempThe set temperature in units of 0.1 degrees centigrade.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.7.1.1.11
oaModuleRelativeTempThe relative temperature in units of 0.1 degrees centigrade.ro
Integer32
.1.3.6.1.4.1.8708.2.19.2.7.1.1.12
oaModuleTempFailureThe module temperature is above/below expected one. A: The temperature is not correct. D: The temperature becomes correct.ro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.13
oaModuleTemperatureThe temperature of the module in 0.1 degrees centigradero
Integer32
.1.3.6.1.4.1.8708.2.19.2.7.1.1.14
oaModuleCommunicationFailureThe communication with the module failed. A(ctivation): Failed to talk to the module D(e-activation): Could talk to the module againro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.15
oaModuleModuleInfoInformation (for example firmware and serial number) about the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.19.2.7.1.1.16
oaModuleVcomThresholdExceededThe common voltage supply in the ROADM module has exceeded recommended threshold. Firmware upgrade is recommended to resolve this alarm. A(ctivation): The VCOM threshold is exceeded D(e-activation): The VCOM threshold is OK againrodeprecated
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.17
oaModuleFirmwareUpgradeAvailableAn upgrade is available for the ROADM module. See release notes for details on how to obtain and install the upgradero
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.18
oaModuleWarmingUpROADM module is warming up, the optics has not reached a stable temperature, all channels are blocked. A(ctivation): cold start of ROADM board D(e-activation): the warning is cleared as soon as the module has reached a stable temperature, this takes 3-8 minutesro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.19
oaModuleFailureThe module HW has detected a failure. A(ctivation): The module has failed D(e-activation): The module is OK againro
FaultStatus
.1.3.6.1.4.1.8708.2.19.2.7.1.1.20