LUM-EQUIPMENT-MIB
AI MIB Summary
The LUM-EQUIPMENT-MIB module provides SNMP-based monitoring and configuration of Lumex hardware infrastructure, specifically tracking subrack status, board states, power supply health, fan operation, and slot occupancy. This MIB enables granular visibility into physical layer components and environmental conditions for telecommunications or industrial networking equipment.
The common equipment configuration MIB.
- General
- Subrack status
- Board configuration and status
- Power supply status
- Fan status
- Slot
Main OID:
lumEquipmentMIBModule.1.3.6.1.4.1.8708.1.1.12
189
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
189 total| Object Name |
|---|
lumEquipmentMIBModuleThe common equipment configuration MIB.
- General
- Subrack status
- Board configuration and status
- Power supply status
- Fan status
- Slot MODULE-IDENTITY .1.3.6.1.4.1.8708.1.1.12 |
lumEquipmentConfs OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.1 |
lumEquipmentGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.1.1 |
lumEquipmentCompl OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.1.2 |
lumEquipmentMinimalGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.1.3 |
lumEquipmentMinimalCompl OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.1.4 |
lumEquipmentMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2 |
equipmentGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.1 |
equipmentGeneralTestAndIncrProtection against simultaneous access from
multiple managers. See SNMPv2-TC.rw TestAndIncr (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.1.1 |
equipmentGeneralMibSpecVersionThe MIB specification version.
tbd: persistent?rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.1.2 |
equipmentGeneralMibImplVersionThe MIB implementation version.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.1.3 |
equipmentGeneralLastChangeTimeThe time when the configuration of the MIB was last
changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.1.4 |
equipmentGeneralStateLastChangeTimeThe time when the state of the MIB was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.1.5 |
equipmentGeneralEquipmentSubrackTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.6 |
equipmentGeneralEquipmentBoardTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.7 |
equipmentGeneralEquipmentPowerTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.8 |
equipmentGeneralEquipmentFanTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.9 |
equipmentGeneralEquipmentSlotTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.10 |
equipmentGeneralEquipmentOpticalModuleTableSizeSize of tablero Unsigned32 .1.3.6.1.4.1.8708.2.11.2.1.11 |
equipmentSubrackList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.2 |
equipmentSubrackTableThe subrack list. SEQUENCE OF EquipmentSubrackEntry .1.3.6.1.4.1.8708.2.11.2.2.1 |
equipmentSubrackEntryAn entry in the subrack list. EquipmentSubrackEntry .1.3.6.1.4.1.8708.2.11.2.2.1.1 |
equipmentSubrackIndexAn arbitrary index assigned to each
subrack entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.2.1.1.1 |
equipmentSubrackNameThe name of the subrack, for example 'sub1'
where the number indicates the subrack number.ro MgmtNameString .1.3.6.1.4.1.8708.2.11.2.2.1.1.2 |
equipmentSubrackSubrackThe number of the subrack.rw SubrackNumber .1.3.6.1.4.1.8708.2.11.2.2.1.1.3 |
equipmentSubrackDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.2.1.1.4 |
equipmentSubrackInvPhysIndexOrZeroThe row in the invPhysTable for this subrack.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.2.1.1.5 |
equipmentSubrackAllFanUnitsFailedAll fan units in a subrack have failed.
A(ctivation): fanUnitFailed active for all fans
within a subrack.
D(e-activiation): fanUnitFailed cleared for one
fan unit.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.6 |
equipmentSubrackRowStatusSNMP administrivia.
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.2.1.1.7 |
equipmentSubrackExpectedTypeThe expected subrack type.rw EquipmentSubrackType .1.3.6.1.4.1.8708.2.11.2.2.1.1.8 |
equipmentSubrackActualTypeThe actual subrack type. If an unexpected
subrack has been detected this variable can be
used to see what type of subrack has been
detected.ro EquipmentSubrackType .1.3.6.1.4.1.8708.2.11.2.2.1.1.9 |
equipmentSubrackUnexpectedTypeA type of subrack not matching the expected
type is present.
A: A subrack with type different from the
expected type is present (even if the subrack
is not activated).
D: The type matches the expected or no
subrack is present.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.10 |
equipmentSubrackTempThe temperature in the subrack in 0.1 degrees centigrade.ro Integer32 (-1000..1000) .1.3.6.1.4.1.8708.2.11.2.2.1.1.11 |
equipmentSubrackTempHighExceededThe threshold for environmental temperature
in the subrack is exceeded.
A: The temperature exceeds the associated threshold.
D: Temperature is 0.5 degrees centigrade below the
associated threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.12 |
equipmentSubrackTempThresholdThe threshold for temperature alarm in the
subrack in 0.1 degrees centigrade.rw Integer32 (-100..800) .1.3.6.1.4.1.8708.2.11.2.2.1.1.13 |
equipmentSubrackDataChangedThe subrack data (dipswitches for subrackId and/or
system mode) has been changed. Changing this data might
affect the system behaviour after the next restart.
A: The subrack data has been changed since startup
D: The subrack data is changed back to the value read
at startup, or the system is restarted.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.14 |
equipmentSubrackSystemModeSetThe value read from the system mode
dipswitches at startup of the CU was
diffrent from 0.
This will affect the behaviour of the
system.
If the lowest bit is set, the backup
is read from the TUs - useful at CU
replacement.
A: The system mode is different from 0
at startup.
D: The system mode is 0 at startup.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.15 |
equipmentSubrackEffectiveSystemModeThe value of the system mode dipswitches
read at startup. This value determines the
system behaviour.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.2.1.1.16 |
equipmentSubrackCurrentSystemModeThe current value of the system mode
dipswitches. Will be used at the next
restart.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.2.1.1.17 |
equipmentSubrackAdminStatusThe administrative state of the subrack.
down - This subrack should not be monitored.
Suppresses alarms.
up - The subrack should be monitored.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.2.1.1.18 |
equipmentSubrackOperStatusThe operational state of the subrack.
notPresent - The subrack is not available.
down - The subrack remains in the 'down'-state
when adminStatus is set to 'down'.
up - The subrack is active and monitored.ro Enumeration .1.3.6.1.4.1.8708.2.11.2.2.1.1.19 |
equipmentSubrackObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.11.2.2.1.1.20 |
equipmentSubrackShelfLengthLength of the half-height slot divider shelf. To be
manually entered by the user. A value of 0 is
interpreted as 'not yet defined by user'.rw Unsigned32 .1.3.6.1.4.1.8708.2.11.2.2.1.1.21 |
equipmentSubrackLANModuleMissingThe subrack LAN/DCN module is missing.
A(ctivation): LAN/DCN module disconnected from subrack
for more than 2 seconds.
D(e-activiation): LAN/DCN module connected to subrack
for more than 2 seconds.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.22 |
equipmentSubrackExpectedFirstPbSlotThe lowest slot number where it is possible to
configure a passive board. Automatically configured
to the actual value supported by hardware if the
hardware is present on subrack configuration.
If no hardware is present at configuration time,
this value is set to 'undefined' until changed by
the user. The 'undefined' value allows passive board
configuration in the same slots as the highest
possible firstPbSlot setting of the subrack type.rw FirstPbSlot .1.3.6.1.4.1.8708.2.11.2.2.1.1.23 |
equipmentSubrackActualFirstPbSlotThe actual lowest slot number where it is possible
to configure a passive board.
When no subrack hardware is present, this value is
'undefined'.ro FirstPbSlot .1.3.6.1.4.1.8708.2.11.2.2.1.1.24 |
equipmentSubrackFirstPbSlotMismatchThe expected first passive slot allows more passive
boards than the hardware supports.
A(ctivation): A subrack and control unit combination
which supports fewer passive boards
than configured is present.
D(e-activiation): A subrack and control unit
combination which supports the
current configuration is present.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.2.1.1.25 |
equipmentSubrackAidThe access identifier (AID) of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.2.1.1.26 |
equipmentSubrackPhysicalLocationThe Physical location of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.2.1.1.27 |
equipmentSubrackChangeExpectedTypeCommand to change expected type,
used when upgrading subrack to a new version,
e.g TM3000 to TM3000/IIro CommandString .1.3.6.1.4.1.8708.2.11.2.2.1.1.28 |
equipmentBoardList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.3 |
equipmentBoardTableThe board list. SEQUENCE OF EquipmentBoardEntry .1.3.6.1.4.1.8708.2.11.2.3.1 |
equipmentBoardEntryAn entry in the board list.
One entry for each slot. EquipmentBoardEntry .1.3.6.1.4.1.8708.2.11.2.3.1.1 |
equipmentBoardIndexAn arbitrary index assigned to each
board entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.3.1.1.1 |
equipmentBoardNameThe name of the board, for example 'tpmr2500:1:2'
where the first number indicates in which sub-rack
the board is present and the second number
in which slot.ro MgmtNameString .1.3.6.1.4.1.8708.2.11.2.3.1.1.2 |
equipmentBoardExpectedTypeThe expected board type.rw EquipmentBoardType .1.3.6.1.4.1.8708.2.11.2.3.1.1.3 |
equipmentBoardActualTypeThe actual board type. If an unexpected board
has been detected this variable can be used to
see what type of board has been detected.ro EquipmentBoardType .1.3.6.1.4.1.8708.2.11.2.3.1.1.4 |
equipmentBoardDescrUser configurable label.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.5 |
equipmentBoardSubrackThe number of the subrack where the board is
located.rw SubrackNumber .1.3.6.1.4.1.8708.2.11.2.3.1.1.6 |
equipmentBoardSlotThe slot where the board is located.rw SlotNumber .1.3.6.1.4.1.8708.2.11.2.3.1.1.7 |
equipmentBoardTempThe temperature on the board in 0.1 degrees
centigrade.ro Integer32 (-1000..1000) .1.3.6.1.4.1.8708.2.11.2.3.1.1.8 |
equipmentBoardInvPhysIndexOrZeroThe row in the invPhysTable for this board.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.3.1.1.9 |
equipmentBoardLedTestLED test for the board.
off - Normal operation.
on - Light all leds.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.10 |
equipmentBoardAdminStatusThe administrative state of the board.
down - The board should be inactive.
Alarms are suppressed.
service - The board is activated but alarms are
suppressed. Intended for use during service or
re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The board should be activated when
it becomes available. Alarms are not suppressed.rw BoardOrInterfaceAdminStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.11 |
equipmentBoardOperStatusThe operational state of the board.
notPresent - The board is not available.
down - The board remains in the 'down'-state
when adminStatus is set to 'down' or if there is
a fault preventing it from going to the
'up'-state.
up - The board is operational. The operational
state becomes 'up' when adminStatus is set to
'up' unless there are faults detected.ro BoardOrInterfaceOperStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.12 |
equipmentBoardLastChangeTimeThe time when the operational state of the
board entry was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.13 |
equipmentBoardRowStatusSNMP administrivia.
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.14 |
equipmentBoardMissingThere is no board present in a slot where the
expected board type is defined. Suppressed if
administrative status is down.
A(ctivation): Card out of place (COP) indication
active for more than 2 seconds.
D(e-activation): Card out of place (COP) indication
inactive for more than 2 seconds.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.15 |
equipmentBoardUnexpectedTypeA type of board not matching the expected type
is present and active in the same slot.
Since the default value for the type is
'undefined' this alarm is raised when inserting
an unconfigured board.
A: A board with type different from the expected
type is present in the slot (even if the board
is not activated).
D: The type matches the expected or no board is
present.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.16 |
equipmentBoardTempHighExceededThe threshold for environmental temperature
on the board is exceeded.
A: The temperature exceeds the associated
threshold.
D: Temperature is 0.5 degrees centigrade
below the associated threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.17 |
equipmentBoardCommunicationFailureCommunication between the control unit and the
the board has failed completely.
A: There is a board present but there has been
no communication established within 20 seconds.
D: Communication is established.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.18 |
equipmentBoardInterworkFailedCommunication between the control unit and the
board has failed due to incompatible software.
A: The control unit and the board have
in-compatible software.
D: The control unit and the board have compatible
software.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.19 |
equipmentBoardSecondaryPowerFailedSecondary DC power (1.8 or 2.5 V) failure.
A: The secondary DC power on the board has
failed.
D: The secondary DC power is present.
Note: If primary power fails a
'communicationFailure' alarm will most likely
be raised instead.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.20 |
equipmentBoardVitalDataMissingProduct data vital for the safe operation
of the equipment is missing.
A: Product data missing.
D: Product data present.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.21 |
equipmentBoardNonVitalDataMissingAdministrative product data is missing.
A: Product data missing.
D: Product data present.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.22 |
equipmentBoardUnderMaintenanceThe board is undergoing maintenance, adminStatus
is set to service.
A: AdminStatus is set to service.
D: AdminStatus is set to another value.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.23 |
equipmentBoardTempThresholdThe threshold for temperature alarm on the
board in 0.1 degrees centigrade.rw Integer32 .1.3.6.1.4.1.8708.2.11.2.3.1.1.24 |
equipmentBoardSwVersionMismatchThe version of the board SW does not match
the SW version running och the main CU.
For versions to match, the release number,
e.g. 'r2b', must be the same. The build
number is not required to be the same.
Examples:
r2b-2 matches r2b-1, r2b-2, ..., r2b-<n>
r2b-<n> does NOT match r2a-<m>
A: The board is started with as SW version
other than the main CU.
D: The board, or main CU, is restarted with
matching SW versions.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.25 |
equipmentBoardObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.11.2.3.1.1.26 |
equipmentBoardTempLowThe low threshold for environmental temperature
on the board is exceeded.
A: The temperature exceeds the associated
low threshold.
D: Temperature is 0.5 degrees centigrade
above the associated threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.27 |
equipmentBoardTempVeryHighThe very high threshold for environmental
temperature on the board is exceeded.
A: The temperature exceeds the associated
threshold.
D: Temperature is 0.5 degrees centigrade
below the associated threshold.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.28 |
equipmentBoardReconfigureApplicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii.
Reconfigure cu or cu2osc board to cuSfp.
Reconfigure cu2osc or cuSfp board to cuSfpii.
Reconfigure older CU-board to cuSfpiii.
Reconfigure voa8chii to voa8chsfp.
Reconfigure tpq10Gfec to tpq10gfeci or vise versa
Reconfigure tpq10GfecReg to tpq10gfecregi or vise versaro CommandString .1.3.6.1.4.1.8708.2.11.2.3.1.1.29 |
equipmentBoardLedStatusLED status for the board.
This is primarily intended for debuggingro Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.30 |
equipmentBoardModuleInfoInformation (for example firmware and serial number) about the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.31 |
equipmentBoardNewSwActivatedButNotRestartedA new SW version on the board has been activated,
but the board has not been rebooted. This means that
after the next reboot, a new SW will be active.
For the main CU, this also means that the backup
will be read from a new directory.
A: A new SW has been activated but the board has
not been rebooted within 12 hours.
D: The board is rebooted or the SW is reverted.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.32 |
equipmentBoardLowTemperatureThe environmental temperature on the board
is below startuptemperature (+3 centigrade).
A: The temperature is below +3 degrees centigrade.
D: Temperature has increased to +5 degrees centigrade.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.33 |
equipmentBoardTempLowThresholdThe threshold for low temperature alarm on the
board in 0.1 degrees centigrade.ro Integer32 (-400..400) .1.3.6.1.4.1.8708.2.11.2.3.1.1.34 |
equipmentBoardAdditionalInfoAdditional information about the board,
e.g. FPGA revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.35 |
equipmentBoardBootErrorThe card fails to boot.
A: The card fails to boot.
D: The card boot successfully.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.36 |
equipmentBoardHardwareErrorA hardware error occured.
A: A hardware error occured.
D: No hardware error.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.37 |
equipmentBoardLowDiskSpaceLow disk space in the board.
A: Not enough disk space.
D: Disk space is enough.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.38 |
equipmentBoardClockDriftClock frequency is out of range.
A: Clock frequency out is out of range.
D: Clock frequency is in range.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.39 |
equipmentBoardPostponeFwUpgradePostpone activation of new traffic firmware when
the board software is upgraded next time. If no
firmware changes are available when upgrading this
option will not have any effect.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.40 |
equipmentBoardActivatePendingFwCommandCommand to activate a pending firmware upgrade.ro CommandString .1.3.6.1.4.1.8708.2.11.2.3.1.1.41 |
equipmentBoardFwActivationPendingFirmware activation has been postponed in a
previous software upgrade.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.42 |
equipmentBoardFeatureNotSupportedA configuration request has failed since the chosen
feature is not supported by the active firmware.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.43 |
equipmentBoardFwReloadNeededThe traffic HW has been programmed by a version
of the system that does not offer a supported
upgrade path to the currently running version.
This typically happens after a downgrade
or rollback of the SW. The state of the
traffic HW is formally unknown and further
changes to the traffic configuration cannot
be guaranteed. A reset of the traffic unit is
recommended. This will cause a short traffic hit.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.44 |
equipmentBoardFwContextUnknownThe running version of the SW cannot recover
the settings of the traffic HW/FW. The state
of the traffic HW is unknown. A reset of the
traffic unit is recommended.
This will cause a short traffic hit.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.45 |
equipmentBoardBoardVariantDetermines board configuration.
dualMuxponderProt - 2x Muxponder with protection
hexTransponder - 6x Transponder
tripleMuxponderProt - 3x Muxponder with protection
quadTransponderProt - 4x Transponder with protection
notApplicable - 2147483647 is used to indicate that the attribute
is not used on the board.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.46 |
equipmentBoardCabinetConnectivityMonitor Cabinet status if enabled. Alarm is raised if connection is lost.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.47 |
equipmentBoardCabinetConnectionFailureConnection to the cabinet has failed.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.3.1.1.48 |
equipmentBoardOperationalVariantOperational Variant mode of board, Normal or OpenFlow Controlled.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.3.1.1.49 |
equipmentBoardAidThe access identifier (AID) of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.50 |
equipmentBoardPhysicalLocationThe Physical location of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.3.1.1.51 |
equipmentPowerList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.4 |
equipmentPowerTableThe list of power supplies. SEQUENCE OF EquipmentPowerEntry .1.3.6.1.4.1.8708.2.11.2.4.1 |
equipmentPowerEntryAn entry in the power supply list. EquipmentPowerEntry .1.3.6.1.4.1.8708.2.11.2.4.1.1 |
equipmentPowerIndexAn arbitrary index assigned to each power module.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.4.1.1.1 |
equipmentPowerNameThe name of the power module.
For example 'pow:1:2'.ro DisplayString .1.3.6.1.4.1.8708.2.11.2.4.1.1.2 |
equipmentPowerSubrackThe number of the subrack in which the power
module is present.ro SubrackNumber .1.3.6.1.4.1.8708.2.11.2.4.1.1.3 |
equipmentPowerSlotThe number of the slot in which the power
module is present.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.4.1.1.4 |
equipmentPowerTypeThe the type of power module.
ac - AC power supply (230V).
dc - DC power supply (48V).ro Enumeration .1.3.6.1.4.1.8708.2.11.2.4.1.1.5 |
equipmentPowerInvPhysIndexOrZeroThe row in the invPhysTable for this power
module. Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.4.1.1.9 |
equipmentPowerAdminStatusThe administrative state of the power module.
down - This power module is not monitored.
Suppresses alarms.
up - The power module is monitored.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.4.1.1.10 |
equipmentPowerOperStatusThe operational state of the power module.
notPresent - The power module is not present.
down - The module is not active or there are
faults preventing it from going to the
'up'-state.
up - The module is operational.ro Enumeration .1.3.6.1.4.1.8708.2.11.2.4.1.1.11 |
equipmentPowerRowStatusManages creation and deletion of conceptual rows.
See also SNMPv2-TC.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.4.1.1.12 |
equipmentPowerACPowerFailedAC power supply failed (230 V).
A(ctivation): Active HW indication.
D(e-activation): Inactive HW indication.roobsolete FaultStatus .1.3.6.1.4.1.8708.2.11.2.4.1.1.13 |
equipmentPowerDCPowerFailedDC power supply failed (48 V).
A: Active HW indication.
D: Inactive HW indication.roobsolete FaultStatus .1.3.6.1.4.1.8708.2.11.2.4.1.1.14 |
equipmentPowerTemperatureHighThe built-in temperature monitoring of the power
module thinks it is too hot.
A: Active HW indication.
D: Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.4.1.1.15 |
equipmentPowerModuleMissingThe power module is not available.
A: Active HW indication.
D: Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.4.1.1.16 |
equipmentPowerObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.11.2.4.1.1.17 |
equipmentPowerDCPowerFailedSeverityThe severity of DC Power failed alarm.rw AlarmPerceivedSeverity .1.3.6.1.4.1.8708.2.11.2.4.1.1.18 |
equipmentPowerAidThe access identifier (AID) of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.4.1.1.19 |
equipmentPowerPhysicalLocationThe Physical location of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.4.1.1.20 |
equipmentPowerPowerFailedPower supply failed.
A: Active HW indication.
D: Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.4.1.1.21 |
equipmentFanList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.5 |
equipmentFanTableThe list of fan modules. SEQUENCE OF EquipmentFanEntry .1.3.6.1.4.1.8708.2.11.2.5.1 |
equipmentFanEntryAn entry in the fan module list. EquipmentFanEntry .1.3.6.1.4.1.8708.2.11.2.5.1.1 |
equipmentFanIndexAn arbitrary index assigned to each fan module.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.5.1.1.1 |
equipmentFanNameThe name of the fan module.
For example 'fan:1:2', where the first number
indicates the subrack and the second number the
fan slot.ro DisplayString .1.3.6.1.4.1.8708.2.11.2.5.1.1.2 |
equipmentFanSubrackThe number of the subrack in which the fan
module is present.ro SubrackNumber .1.3.6.1.4.1.8708.2.11.2.5.1.1.3 |
equipmentFanSlotThe number of the fan-slot in which the fan
module is present.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.5.1.1.4 |
equipmentFanInvPhysIndexOrZeroThe row in the invPhysTable for this fan module.
Set to 0 if not known.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.5.1.1.5 |
equipmentFanAdminStatusThe administrative state of the fan module.
down - This fan module should not be monitored.
Suppresses alarms. Useful if a subrack has only
one fan for some reason.
up - The fan module should be monitored.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.5.1.1.6 |
equipmentFanOperStatusThe operational state of the fan module.
Note: It is not possible to distinguish between
a missing fan and a failed fan. Therefore
'notPresent' is currently not used.
down - The fan module is not de-activated or not
present or there are faults preventing it from
going to the 'up'-state.
up - The fan module is active and monitored.ro Enumeration .1.3.6.1.4.1.8708.2.11.2.5.1.1.7 |
equipmentFanRowStatusManages creation and deletion of conceptual rows.
See also SNMPv2-TC.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.5.1.1.8 |
equipmentFanUnitFailedThe fan module has failed or is absent.
A(ctivation): Active HW indication.
D(e-activation): Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.5.1.1.9 |
equipmentFanMainUnitFailedThe main fan module has failed or is absent.
A(ctivation): Active HW indication.
D(e-activation): Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.5.1.1.10 |
equipmentFanObjectPropertyProperty mask.ro ObjectProperty .1.3.6.1.4.1.8708.2.11.2.5.1.1.11 |
equipmentFanFanFaultThe Fan malfunction or fan speed differs from the set speed.
A(ctivation): Active HW indication.
D(e-activation): Inactive HW indication.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.5.1.1.12 |
equipmentFanAidThe access identifier (AID) of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.5.1.1.13 |
equipmentFanPhysicalLocationThe Physical location of the product.
The format is according to GR-833.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.5.1.1.14 |
lumentisEquipmentNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.6 |
equipmentNotifyPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.6.0 |
equipmentBoardRowStatusActiveSent when a board is added to the configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.8708.2.11.2.6.0.1 |
equipmentBoardRowStatusDestroySent when a board is removed from the
configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.8708.2.11.2.6.0.2 |
equipmentBoardRowStatusInsertedSent when a board is physically inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.8708.2.11.2.6.0.3 |
equipmentBoardRowStatusRemovedSent when a board is physically removed. NOTIFICATION-TYPE .1.3.6.1.4.1.8708.2.11.2.6.0.4 |
equipmentBoardRowStatusDeletedSent when a board is deleted from the
configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.8708.2.11.2.6.0.5 |
equipmentNode OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.7 |
equipmentNodeLedTestLED test for the network element.
off - Normal operation.
on - Light all leds.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.1 |
equipmentNodeIcnRedundancyModeIndicates whether the internal communication
network between sub-racks, ICN3 and ICN4, can be
connected in a redundant manner or not.
disabled - Non-redundant ICN connection.
Both ICN ports are enable for forwarding.
Note: Connecting both ICN ports to the same internal switch
will cause a loop.
ring - Redundant ICN connection. Only one ICN port at a time
is enabled for forwarding even if both are physically connected
and both links are up.
Note: The port that is first connected will be used for
forwarding and if disconnected, the other port will be
enabled automatically.
disabled - Non-redundant connection.
ring - Redundantly connected in a ring.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.2 |
equipmentNodeMemoryProfileIndicates whether memory profilation shall be
done or not.
disabled - No memory profile
enabled - Memory profile donero Enumeration .1.3.6.1.4.1.8708.2.11.2.7.3 |
equipmentAllowDummyPassiveSlotsThis option is applicable for TM-3000
subracks only.
Normally passive boards can only be created in
slots 13-22. Enabling this options allows the
user to create full-size passive board objects
in slot 2-12 as well.
Note, however, that supervision of board presence
and reading of board inventory is NOT possible
in slot 2-12.
Also note that half-size boards, like ad1AB, are
not allowed in slots 2-12.
disabled - Passive boards NOT allowed in slots 2-12.
enabled - Allow full-size passive boards objects
in slot 2-12.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.4 |
equipmentNodeManagementVlanIndicates if VLAN is available (via DCN for nodes with cu) or not.
off - No bridging of VLAN. (mgmtVlan off in node)
bridge2dcn - VLAN is bridged to DCN. (mgmtVlan on in node, used for cu)
on - mgmtVlan is on, used for culessrw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.5 |
equipmentNodeMgmtVlanPrivacySet Mgmt Vlan privacy. Setting is for main subrack in node.
Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G
and gbe22Emxp10G.
isolated - privacy enabled. Not possible to communicate
between boards nor ports. In slave subrack setting is only
on ports, not boards
community - privacy disabled. It is possible to communicate
between both boards and ports.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.6 |
equipmentNodeDcnRedundancyModeIndicates whether the DCN ports on a CU, DCN1 and DCN2,
can be connected in a redundant manner or not.
disabled - Non-redundant DCN connection.
Both DCN ports are enable for forwarding.
Note: Connecting both DCN ports to the same ethernet switch
will cause a loop.
enabled - Redundant DCN connection. Only one DCN port at a time
is enabled for forwarding even if both are physically connected
and both links are up.
Note: The port that is first connected will be used for
forwarding and if disconnected, the other port will be
enabled automatically.
disabled - Non-redundant connection.
enabled - Redundantly connected through a hub.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.7 |
equipmentNodeProxyArpIndicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies
the IP-address allocation and minimizes the use of different subnets in the network.
disabled - Proxy ARP function disabled. The nodes must be in different subnets and
PPP links use routing between the nodes.
enabled - Proxy ARP function enabled. All nodes can be in the same IP-subnet and
PPP links do not require routing between the nodes.
The Gateway node/Gateway Network Element (GNE) act as router.rw Enumeration .1.3.6.1.4.1.8708.2.11.2.7.8 |
equipmentResource OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.8 |
equipmentResourceNumberOfBoardsThe number of boards, active and passive, currently in use
in this systemro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.8.1 |
equipmentResourceMaxNumberOfBoardsThe maximum number of boards, active and passive, that is
supported by the embedded software of this systemro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.8.2 |
equipmentResourceNumberOfActiveBoardsThe number of active boards running on this systemro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.8.3 |
equipmentResourceMaxNumberOfActiveBoardsThe maximum number of active boards that is supported by the
embedded software of this system.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.8.4 |
equipmentSlot OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.9 |
equipmentSlotTableThe slot list. SEQUENCE OF EquipmentSlotEntry .1.3.6.1.4.1.8708.2.11.2.9.1 |
equipmentSlotEntryAn entry in the slot list.
One entry for each slot. EquipmentSlotEntry .1.3.6.1.4.1.8708.2.11.2.9.1.1 |
equipmentSlotIndexAn arbitrary index assigned to each
slot entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.9.1.1.1 |
equipmentSlotNameThe name of the slot, for example 'tpmr2500:1:2'
where the first number indicates in which sub-rack
the slot is present and the second number
in which slot.ro MgmtNameString .1.3.6.1.4.1.8708.2.11.2.9.1.1.2 |
equipmentSlotSubrackThe number of the subrack in which the slot
is present.ro SubrackNumber .1.3.6.1.4.1.8708.2.11.2.9.1.1.3 |
equipmentSlotSlotThe slot number.ro SlotNumber .1.3.6.1.4.1.8708.2.11.2.9.1.1.4 |
equipmentSlotAdminStatusThe administrative state of the slot.
down - The slot is not monitored.
up - The interface should be activated.rw AdminStatus .1.3.6.1.4.1.8708.2.11.2.9.1.1.5 |
equipmentSlotUsageStateTells if the slot is used or not.
used - Slot is used.
notUsed - Slot is not used.ro Enumeration .1.3.6.1.4.1.8708.2.11.2.9.1.1.6 |
equipmentSlotEmptySlotSlot is empty, alarm only applicable for systems with mendatory slot usage
A: Slot is empty.
D: No empty slot.ro FaultStatus .1.3.6.1.4.1.8708.2.11.2.9.1.1.7 |
equipmentSlotEquippedIs the entity equipped.ro TruthValueWithNA .1.3.6.1.4.1.8708.2.11.2.9.1.1.8 |
equipmentSlotAidThe access identifier (AID) of the slot.
The format is according to GR-833.ro DisplayString .1.3.6.1.4.1.8708.2.11.2.9.1.1.9 |
equipmentSlotPhysicalLocationThe physical location of the slot.
The format is according to GR-833.ro DisplayString .1.3.6.1.4.1.8708.2.11.2.9.1.1.10 |
equipmentOpticalModuleList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.11.2.10 |
equipmentOpticalModuleTableThe module list. SEQUENCE OF EquipmentOpticalModuleEntry .1.3.6.1.4.1.8708.2.11.2.10.1 |
equipmentOpticalModuleEntryAn entry in the module list. EquipmentOpticalModuleEntry .1.3.6.1.4.1.8708.2.11.2.10.1.1 |
equipmentOpticalModuleIndexAn arbitrary index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.11.2.10.1.1.1 |
equipmentOpticalModuleHostBoardTypeThe actual board type hosting the optical module.ro EquipmentBoardType .1.3.6.1.4.1.8708.2.11.2.10.1.1.2 |
equipmentOpticalModuleTypeThe type of optical module,
for example monitor, switch, wss, amp etcro MgmtNameString .1.3.6.1.4.1.8708.2.11.2.10.1.1.3 |
equipmentOpticalModuleNameThe management name of the interface,
for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'.ro MgmtNameString .1.3.6.1.4.1.8708.2.11.2.10.1.1.4 |
equipmentOpticalModuleSubrackThe number of the subrack where the module
is located.ro SubrackNumber .1.3.6.1.4.1.8708.2.11.2.10.1.1.5 |
equipmentOpticalModuleSlotThe number of the slot where the module is
located.ro SlotNumber .1.3.6.1.4.1.8708.2.11.2.10.1.1.6 |
equipmentOpticalModuleFirmwareVersionFirmware version of the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.10.1.1.7 |
equipmentOpticalModuleSerialNumberSerial number of the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.11.2.10.1.1.8 |
equipmentOpticalModuleWarmingUpStateModule is warming up, the optics has not reached a stable
state.
True: Module is warming up.
False: Module is ready and optics have reached stable state.ro TruthValueWithNA .1.3.6.1.4.1.8708.2.11.2.10.1.1.9 |
equipmentOpticalModuleFailureThe module is experiencing a failure.
A(ctivation): The module has failed