Home/Catalog/LUM-EQUIPMENT-MIB

LUM-EQUIPMENT-MIB

AI MIB Summary

The LUM-EQUIPMENT-MIB module provides SNMP-based monitoring and configuration of Lumex hardware infrastructure, specifically tracking subrack status, board states, power supply health, fan operation, and slot occupancy. This MIB enables granular visibility into physical layer components and environmental conditions for telecommunications or industrial networking equipment.

The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
Main OID:
lumEquipmentMIBModule.1.3.6.1.4.1.8708.1.1.12
189
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

189 total
Object Name
lumEquipmentMIBModuleThe common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
MODULE-IDENTITY
.1.3.6.1.4.1.8708.1.1.12
lumEquipmentConfs
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.1
lumEquipmentGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.1.1
lumEquipmentCompl
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.1.2
lumEquipmentMinimalGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.1.3
lumEquipmentMinimalCompl
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.1.4
lumEquipmentMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2
equipmentGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.1
equipmentGeneralTestAndIncrProtection against simultaneous access from multiple managers. See SNMPv2-TC.rw
TestAndIncr (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.1.1
equipmentGeneralMibSpecVersionThe MIB specification version. tbd: persistent?rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.1.2
equipmentGeneralMibImplVersionThe MIB implementation version.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.1.3
equipmentGeneralLastChangeTimeThe time when the configuration of the MIB was last changed.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.1.4
equipmentGeneralStateLastChangeTimeThe time when the state of the MIB was last changed.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.1.5
equipmentGeneralEquipmentSubrackTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.6
equipmentGeneralEquipmentBoardTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.7
equipmentGeneralEquipmentPowerTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.8
equipmentGeneralEquipmentFanTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.9
equipmentGeneralEquipmentSlotTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.10
equipmentGeneralEquipmentOpticalModuleTableSizeSize of tablero
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.1.11
equipmentSubrackList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.2
equipmentSubrackTableThe subrack list.
SEQUENCE OF EquipmentSubrackEntry
.1.3.6.1.4.1.8708.2.11.2.2.1
equipmentSubrackEntryAn entry in the subrack list.
EquipmentSubrackEntry
.1.3.6.1.4.1.8708.2.11.2.2.1.1
equipmentSubrackIndexAn arbitrary index assigned to each subrack entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.1
equipmentSubrackNameThe name of the subrack, for example 'sub1' where the number indicates the subrack number.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.11.2.2.1.1.2
equipmentSubrackSubrackThe number of the subrack.rw
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.2.1.1.3
equipmentSubrackDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.4
equipmentSubrackInvPhysIndexOrZeroThe row in the invPhysTable for this subrack. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.5
equipmentSubrackAllFanUnitsFailedAll fan units in a subrack have failed. A(ctivation): fanUnitFailed active for all fans within a subrack. D(e-activiation): fanUnitFailed cleared for one fan unit.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.6
equipmentSubrackRowStatusSNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.7
equipmentSubrackExpectedTypeThe expected subrack type.rw
EquipmentSubrackType
.1.3.6.1.4.1.8708.2.11.2.2.1.1.8
equipmentSubrackActualTypeThe actual subrack type. If an unexpected subrack has been detected this variable can be used to see what type of subrack has been detected.ro
EquipmentSubrackType
.1.3.6.1.4.1.8708.2.11.2.2.1.1.9
equipmentSubrackUnexpectedTypeA type of subrack not matching the expected type is present. A: A subrack with type different from the expected type is present (even if the subrack is not activated). D: The type matches the expected or no subrack is present.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.10
equipmentSubrackTempThe temperature in the subrack in 0.1 degrees centigrade.ro
Integer32 (-1000..1000)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.11
equipmentSubrackTempHighExceededThe threshold for environmental temperature in the subrack is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.12
equipmentSubrackTempThresholdThe threshold for temperature alarm in the subrack in 0.1 degrees centigrade.rw
Integer32 (-100..800)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.13
equipmentSubrackDataChangedThe subrack data (dipswitches for subrackId and/or system mode) has been changed. Changing this data might affect the system behaviour after the next restart. A: The subrack data has been changed since startup D: The subrack data is changed back to the value read at startup, or the system is restarted.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.14
equipmentSubrackSystemModeSetThe value read from the system mode dipswitches at startup of the CU was diffrent from 0. This will affect the behaviour of the system. If the lowest bit is set, the backup is read from the TUs - useful at CU replacement. A: The system mode is different from 0 at startup. D: The system mode is 0 at startup.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.15
equipmentSubrackEffectiveSystemModeThe value of the system mode dipswitches read at startup. This value determines the system behaviour.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.16
equipmentSubrackCurrentSystemModeThe current value of the system mode dipswitches. Will be used at the next restart.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.17
equipmentSubrackAdminStatusThe administrative state of the subrack. down - This subrack should not be monitored. Suppresses alarms. up - The subrack should be monitored.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.2.1.1.18
equipmentSubrackOperStatusThe operational state of the subrack. notPresent - The subrack is not available. down - The subrack remains in the 'down'-state when adminStatus is set to 'down'. up - The subrack is active and monitored.ro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.2.1.1.19
equipmentSubrackObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.11.2.2.1.1.20
equipmentSubrackShelfLengthLength of the half-height slot divider shelf. To be manually entered by the user. A value of 0 is interpreted as 'not yet defined by user'.rw
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.21
equipmentSubrackLANModuleMissingThe subrack LAN/DCN module is missing. A(ctivation): LAN/DCN module disconnected from subrack for more than 2 seconds. D(e-activiation): LAN/DCN module connected to subrack for more than 2 seconds.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.22
equipmentSubrackExpectedFirstPbSlotThe lowest slot number where it is possible to configure a passive board. Automatically configured to the actual value supported by hardware if the hardware is present on subrack configuration. If no hardware is present at configuration time, this value is set to 'undefined' until changed by the user. The 'undefined' value allows passive board configuration in the same slots as the highest possible firstPbSlot setting of the subrack type.rw
FirstPbSlot
.1.3.6.1.4.1.8708.2.11.2.2.1.1.23
equipmentSubrackActualFirstPbSlotThe actual lowest slot number where it is possible to configure a passive board. When no subrack hardware is present, this value is 'undefined'.ro
FirstPbSlot
.1.3.6.1.4.1.8708.2.11.2.2.1.1.24
equipmentSubrackFirstPbSlotMismatchThe expected first passive slot allows more passive boards than the hardware supports. A(ctivation): A subrack and control unit combination which supports fewer passive boards than configured is present. D(e-activiation): A subrack and control unit combination which supports the current configuration is present.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.2.1.1.25
equipmentSubrackAidThe access identifier (AID) of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.26
equipmentSubrackPhysicalLocationThe Physical location of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.2.1.1.27
equipmentSubrackChangeExpectedTypeCommand to change expected type, used when upgrading subrack to a new version, e.g TM3000 to TM3000/IIro
CommandString
.1.3.6.1.4.1.8708.2.11.2.2.1.1.28
equipmentBoardList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.3
equipmentBoardTableThe board list.
SEQUENCE OF EquipmentBoardEntry
.1.3.6.1.4.1.8708.2.11.2.3.1
equipmentBoardEntryAn entry in the board list. One entry for each slot.
EquipmentBoardEntry
.1.3.6.1.4.1.8708.2.11.2.3.1.1
equipmentBoardIndexAn arbitrary index assigned to each board entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.3.1.1.1
equipmentBoardNameThe name of the board, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the board is present and the second number in which slot.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.11.2.3.1.1.2
equipmentBoardExpectedTypeThe expected board type.rw
EquipmentBoardType
.1.3.6.1.4.1.8708.2.11.2.3.1.1.3
equipmentBoardActualTypeThe actual board type. If an unexpected board has been detected this variable can be used to see what type of board has been detected.ro
EquipmentBoardType
.1.3.6.1.4.1.8708.2.11.2.3.1.1.4
equipmentBoardDescrUser configurable label.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.5
equipmentBoardSubrackThe number of the subrack where the board is located.rw
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.3.1.1.6
equipmentBoardSlotThe slot where the board is located.rw
SlotNumber
.1.3.6.1.4.1.8708.2.11.2.3.1.1.7
equipmentBoardTempThe temperature on the board in 0.1 degrees centigrade.ro
Integer32 (-1000..1000)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.8
equipmentBoardInvPhysIndexOrZeroThe row in the invPhysTable for this board. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.3.1.1.9
equipmentBoardLedTestLED test for the board. off - Normal operation. on - Light all leds.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.10
equipmentBoardAdminStatusThe administrative state of the board. down - The board should be inactive. Alarms are suppressed. service - The board is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The board should be activated when it becomes available. Alarms are not suppressed.rw
BoardOrInterfaceAdminStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.11
equipmentBoardOperStatusThe operational state of the board. notPresent - The board is not available. down - The board remains in the 'down'-state when adminStatus is set to 'down' or if there is a fault preventing it from going to the 'up'-state. up - The board is operational. The operational state becomes 'up' when adminStatus is set to 'up' unless there are faults detected.ro
BoardOrInterfaceOperStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.12
equipmentBoardLastChangeTimeThe time when the operational state of the board entry was last changed.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.13
equipmentBoardRowStatusSNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.14
equipmentBoardMissingThere is no board present in a slot where the expected board type is defined. Suppressed if administrative status is down. A(ctivation): Card out of place (COP) indication active for more than 2 seconds. D(e-activation): Card out of place (COP) indication inactive for more than 2 seconds.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.15
equipmentBoardUnexpectedTypeA type of board not matching the expected type is present and active in the same slot. Since the default value for the type is 'undefined' this alarm is raised when inserting an unconfigured board. A: A board with type different from the expected type is present in the slot (even if the board is not activated). D: The type matches the expected or no board is present.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.16
equipmentBoardTempHighExceededThe threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.17
equipmentBoardCommunicationFailureCommunication between the control unit and the the board has failed completely. A: There is a board present but there has been no communication established within 20 seconds. D: Communication is established.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.18
equipmentBoardInterworkFailedCommunication between the control unit and the board has failed due to incompatible software. A: The control unit and the board have in-compatible software. D: The control unit and the board have compatible software.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.19
equipmentBoardSecondaryPowerFailedSecondary DC power (1.8 or 2.5 V) failure. A: The secondary DC power on the board has failed. D: The secondary DC power is present. Note: If primary power fails a 'communicationFailure' alarm will most likely be raised instead.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.20
equipmentBoardVitalDataMissingProduct data vital for the safe operation of the equipment is missing. A: Product data missing. D: Product data present.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.21
equipmentBoardNonVitalDataMissingAdministrative product data is missing. A: Product data missing. D: Product data present.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.22
equipmentBoardUnderMaintenanceThe board is undergoing maintenance, adminStatus is set to service. A: AdminStatus is set to service. D: AdminStatus is set to another value.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.23
equipmentBoardTempThresholdThe threshold for temperature alarm on the board in 0.1 degrees centigrade.rw
Integer32
.1.3.6.1.4.1.8708.2.11.2.3.1.1.24
equipmentBoardSwVersionMismatchThe version of the board SW does not match the SW version running och the main CU. For versions to match, the release number, e.g. 'r2b', must be the same. The build number is not required to be the same. Examples: r2b-2 matches r2b-1, r2b-2, ..., r2b-<n> r2b-<n> does NOT match r2a-<m> A: The board is started with as SW version other than the main CU. D: The board, or main CU, is restarted with matching SW versions.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.25
equipmentBoardObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.11.2.3.1.1.26
equipmentBoardTempLowThe low threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated low threshold. D: Temperature is 0.5 degrees centigrade above the associated threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.27
equipmentBoardTempVeryHighThe very high threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.28
equipmentBoardReconfigureApplicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. Reconfigure cu or cu2osc board to cuSfp. Reconfigure cu2osc or cuSfp board to cuSfpii. Reconfigure older CU-board to cuSfpiii. Reconfigure voa8chii to voa8chsfp. Reconfigure tpq10Gfec to tpq10gfeci or vise versa Reconfigure tpq10GfecReg to tpq10gfecregi or vise versaro
CommandString
.1.3.6.1.4.1.8708.2.11.2.3.1.1.29
equipmentBoardLedStatusLED status for the board. This is primarily intended for debuggingro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.30
equipmentBoardModuleInfoInformation (for example firmware and serial number) about the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.31
equipmentBoardNewSwActivatedButNotRestartedA new SW version on the board has been activated, but the board has not been rebooted. This means that after the next reboot, a new SW will be active. For the main CU, this also means that the backup will be read from a new directory. A: A new SW has been activated but the board has not been rebooted within 12 hours. D: The board is rebooted or the SW is reverted.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.32
equipmentBoardLowTemperatureThe environmental temperature on the board is below startuptemperature (+3 centigrade). A: The temperature is below +3 degrees centigrade. D: Temperature has increased to +5 degrees centigrade.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.33
equipmentBoardTempLowThresholdThe threshold for low temperature alarm on the board in 0.1 degrees centigrade.ro
Integer32 (-400..400)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.34
equipmentBoardAdditionalInfoAdditional information about the board, e.g. FPGA revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.35
equipmentBoardBootErrorThe card fails to boot. A: The card fails to boot. D: The card boot successfully.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.36
equipmentBoardHardwareErrorA hardware error occured. A: A hardware error occured. D: No hardware error.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.37
equipmentBoardLowDiskSpaceLow disk space in the board. A: Not enough disk space. D: Disk space is enough.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.38
equipmentBoardClockDriftClock frequency is out of range. A: Clock frequency out is out of range. D: Clock frequency is in range.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.39
equipmentBoardPostponeFwUpgradePostpone activation of new traffic firmware when the board software is upgraded next time. If no firmware changes are available when upgrading this option will not have any effect.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.40
equipmentBoardActivatePendingFwCommandCommand to activate a pending firmware upgrade.ro
CommandString
.1.3.6.1.4.1.8708.2.11.2.3.1.1.41
equipmentBoardFwActivationPendingFirmware activation has been postponed in a previous software upgrade.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.42
equipmentBoardFeatureNotSupportedA configuration request has failed since the chosen feature is not supported by the active firmware.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.43
equipmentBoardFwReloadNeededThe traffic HW has been programmed by a version of the system that does not offer a supported upgrade path to the currently running version. This typically happens after a downgrade or rollback of the SW. The state of the traffic HW is formally unknown and further changes to the traffic configuration cannot be guaranteed. A reset of the traffic unit is recommended. This will cause a short traffic hit.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.44
equipmentBoardFwContextUnknownThe running version of the SW cannot recover the settings of the traffic HW/FW. The state of the traffic HW is unknown. A reset of the traffic unit is recommended. This will cause a short traffic hit.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.45
equipmentBoardBoardVariantDetermines board configuration. dualMuxponderProt - 2x Muxponder with protection hexTransponder - 6x Transponder tripleMuxponderProt - 3x Muxponder with protection quadTransponderProt - 4x Transponder with protection notApplicable - 2147483647 is used to indicate that the attribute is not used on the board.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.46
equipmentBoardCabinetConnectivityMonitor Cabinet status if enabled. Alarm is raised if connection is lost.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.47
equipmentBoardCabinetConnectionFailureConnection to the cabinet has failed.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.3.1.1.48
equipmentBoardOperationalVariantOperational Variant mode of board, Normal or OpenFlow Controlled.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.3.1.1.49
equipmentBoardAidThe access identifier (AID) of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.50
equipmentBoardPhysicalLocationThe Physical location of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.3.1.1.51
equipmentPowerList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.4
equipmentPowerTableThe list of power supplies.
SEQUENCE OF EquipmentPowerEntry
.1.3.6.1.4.1.8708.2.11.2.4.1
equipmentPowerEntryAn entry in the power supply list.
EquipmentPowerEntry
.1.3.6.1.4.1.8708.2.11.2.4.1.1
equipmentPowerIndexAn arbitrary index assigned to each power module.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.4.1.1.1
equipmentPowerNameThe name of the power module. For example 'pow:1:2'.ro
DisplayString
.1.3.6.1.4.1.8708.2.11.2.4.1.1.2
equipmentPowerSubrackThe number of the subrack in which the power module is present.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.4.1.1.3
equipmentPowerSlotThe number of the slot in which the power module is present.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.4.1.1.4
equipmentPowerTypeThe the type of power module. ac - AC power supply (230V). dc - DC power supply (48V).ro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.4.1.1.5
equipmentPowerInvPhysIndexOrZeroThe row in the invPhysTable for this power module. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.4.1.1.9
equipmentPowerAdminStatusThe administrative state of the power module. down - This power module is not monitored. Suppresses alarms. up - The power module is monitored.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.4.1.1.10
equipmentPowerOperStatusThe operational state of the power module. notPresent - The power module is not present. down - The module is not active or there are faults preventing it from going to the 'up'-state. up - The module is operational.ro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.4.1.1.11
equipmentPowerRowStatusManages creation and deletion of conceptual rows. See also SNMPv2-TC.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.4.1.1.12
equipmentPowerACPowerFailedAC power supply failed (230 V). A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.roobsolete
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.4.1.1.13
equipmentPowerDCPowerFailedDC power supply failed (48 V). A: Active HW indication. D: Inactive HW indication.roobsolete
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.4.1.1.14
equipmentPowerTemperatureHighThe built-in temperature monitoring of the power module thinks it is too hot. A: Active HW indication. D: Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.4.1.1.15
equipmentPowerModuleMissingThe power module is not available. A: Active HW indication. D: Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.4.1.1.16
equipmentPowerObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.11.2.4.1.1.17
equipmentPowerDCPowerFailedSeverityThe severity of DC Power failed alarm.rw
AlarmPerceivedSeverity
.1.3.6.1.4.1.8708.2.11.2.4.1.1.18
equipmentPowerAidThe access identifier (AID) of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.4.1.1.19
equipmentPowerPhysicalLocationThe Physical location of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.4.1.1.20
equipmentPowerPowerFailedPower supply failed. A: Active HW indication. D: Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.4.1.1.21
equipmentFanList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.5
equipmentFanTableThe list of fan modules.
SEQUENCE OF EquipmentFanEntry
.1.3.6.1.4.1.8708.2.11.2.5.1
equipmentFanEntryAn entry in the fan module list.
EquipmentFanEntry
.1.3.6.1.4.1.8708.2.11.2.5.1.1
equipmentFanIndexAn arbitrary index assigned to each fan module.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.5.1.1.1
equipmentFanNameThe name of the fan module. For example 'fan:1:2', where the first number indicates the subrack and the second number the fan slot.ro
DisplayString
.1.3.6.1.4.1.8708.2.11.2.5.1.1.2
equipmentFanSubrackThe number of the subrack in which the fan module is present.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.5.1.1.3
equipmentFanSlotThe number of the fan-slot in which the fan module is present.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.5.1.1.4
equipmentFanInvPhysIndexOrZeroThe row in the invPhysTable for this fan module. Set to 0 if not known.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.5.1.1.5
equipmentFanAdminStatusThe administrative state of the fan module. down - This fan module should not be monitored. Suppresses alarms. Useful if a subrack has only one fan for some reason. up - The fan module should be monitored.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.5.1.1.6
equipmentFanOperStatusThe operational state of the fan module. Note: It is not possible to distinguish between a missing fan and a failed fan. Therefore 'notPresent' is currently not used. down - The fan module is not de-activated or not present or there are faults preventing it from going to the 'up'-state. up - The fan module is active and monitored.ro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.5.1.1.7
equipmentFanRowStatusManages creation and deletion of conceptual rows. See also SNMPv2-TC.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.5.1.1.8
equipmentFanUnitFailedThe fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.5.1.1.9
equipmentFanMainUnitFailedThe main fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.5.1.1.10
equipmentFanObjectPropertyProperty mask.ro
ObjectProperty
.1.3.6.1.4.1.8708.2.11.2.5.1.1.11
equipmentFanFanFaultThe Fan malfunction or fan speed differs from the set speed. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.5.1.1.12
equipmentFanAidThe access identifier (AID) of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.5.1.1.13
equipmentFanPhysicalLocationThe Physical location of the product. The format is according to GR-833.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.5.1.1.14
lumentisEquipmentNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.6
equipmentNotifyPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.6.0
equipmentBoardRowStatusActiveSent when a board is added to the configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8708.2.11.2.6.0.1
equipmentBoardRowStatusDestroySent when a board is removed from the configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8708.2.11.2.6.0.2
equipmentBoardRowStatusInsertedSent when a board is physically inserted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8708.2.11.2.6.0.3
equipmentBoardRowStatusRemovedSent when a board is physically removed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8708.2.11.2.6.0.4
equipmentBoardRowStatusDeletedSent when a board is deleted from the configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8708.2.11.2.6.0.5
equipmentNode
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.7
equipmentNodeLedTestLED test for the network element. off - Normal operation. on - Light all leds.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.1
equipmentNodeIcnRedundancyModeIndicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop. ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. ring - Redundantly connected in a ring.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.2
equipmentNodeMemoryProfileIndicates whether memory profilation shall be done or not. disabled - No memory profile enabled - Memory profile donero
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.3
equipmentAllowDummyPassiveSlotsThis option is applicable for TM-3000 subracks only. Normally passive boards can only be created in slots 13-22. Enabling this options allows the user to create full-size passive board objects in slot 2-12 as well. Note, however, that supervision of board presence and reading of board inventory is NOT possible in slot 2-12. Also note that half-size boards, like ad1AB, are not allowed in slots 2-12. disabled - Passive boards NOT allowed in slots 2-12. enabled - Allow full-size passive boards objects in slot 2-12.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.4
equipmentNodeManagementVlanIndicates if VLAN is available (via DCN for nodes with cu) or not. off - No bridging of VLAN. (mgmtVlan off in node) bridge2dcn - VLAN is bridged to DCN. (mgmtVlan on in node, used for cu) on - mgmtVlan is on, used for culessrw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.5
equipmentNodeMgmtVlanPrivacySet Mgmt Vlan privacy. Setting is for main subrack in node. Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G and gbe22Emxp10G. isolated - privacy enabled. Not possible to communicate between boards nor ports. In slave subrack setting is only on ports, not boards community - privacy disabled. It is possible to communicate between both boards and ports.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.6
equipmentNodeDcnRedundancyModeIndicates whether the DCN ports on a CU, DCN1 and DCN2, can be connected in a redundant manner or not. disabled - Non-redundant DCN connection. Both DCN ports are enable for forwarding. Note: Connecting both DCN ports to the same ethernet switch will cause a loop. enabled - Redundant DCN connection. Only one DCN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. enabled - Redundantly connected through a hub.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.7
equipmentNodeProxyArpIndicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies the IP-address allocation and minimizes the use of different subnets in the network. disabled - Proxy ARP function disabled. The nodes must be in different subnets and PPP links use routing between the nodes. enabled - Proxy ARP function enabled. All nodes can be in the same IP-subnet and PPP links do not require routing between the nodes. The Gateway node/Gateway Network Element (GNE) act as router.rw
Enumeration
.1.3.6.1.4.1.8708.2.11.2.7.8
equipmentResource
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.8
equipmentResourceNumberOfBoardsThe number of boards, active and passive, currently in use in this systemro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.8.1
equipmentResourceMaxNumberOfBoardsThe maximum number of boards, active and passive, that is supported by the embedded software of this systemro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.8.2
equipmentResourceNumberOfActiveBoardsThe number of active boards running on this systemro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.8.3
equipmentResourceMaxNumberOfActiveBoardsThe maximum number of active boards that is supported by the embedded software of this system.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.8.4
equipmentSlot
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.9
equipmentSlotTableThe slot list.
SEQUENCE OF EquipmentSlotEntry
.1.3.6.1.4.1.8708.2.11.2.9.1
equipmentSlotEntryAn entry in the slot list. One entry for each slot.
EquipmentSlotEntry
.1.3.6.1.4.1.8708.2.11.2.9.1.1
equipmentSlotIndexAn arbitrary index assigned to each slot entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.9.1.1.1
equipmentSlotNameThe name of the slot, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the slot is present and the second number in which slot.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.11.2.9.1.1.2
equipmentSlotSubrackThe number of the subrack in which the slot is present.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.9.1.1.3
equipmentSlotSlotThe slot number.ro
SlotNumber
.1.3.6.1.4.1.8708.2.11.2.9.1.1.4
equipmentSlotAdminStatusThe administrative state of the slot. down - The slot is not monitored. up - The interface should be activated.rw
AdminStatus
.1.3.6.1.4.1.8708.2.11.2.9.1.1.5
equipmentSlotUsageStateTells if the slot is used or not. used - Slot is used. notUsed - Slot is not used.ro
Enumeration
.1.3.6.1.4.1.8708.2.11.2.9.1.1.6
equipmentSlotEmptySlotSlot is empty, alarm only applicable for systems with mendatory slot usage A: Slot is empty. D: No empty slot.ro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.9.1.1.7
equipmentSlotEquippedIs the entity equipped.ro
TruthValueWithNA
.1.3.6.1.4.1.8708.2.11.2.9.1.1.8
equipmentSlotAidThe access identifier (AID) of the slot. The format is according to GR-833.ro
DisplayString
.1.3.6.1.4.1.8708.2.11.2.9.1.1.9
equipmentSlotPhysicalLocationThe physical location of the slot. The format is according to GR-833.ro
DisplayString
.1.3.6.1.4.1.8708.2.11.2.9.1.1.10
equipmentOpticalModuleList
OBJECT IDENTIFIER
.1.3.6.1.4.1.8708.2.11.2.10
equipmentOpticalModuleTableThe module list.
SEQUENCE OF EquipmentOpticalModuleEntry
.1.3.6.1.4.1.8708.2.11.2.10.1
equipmentOpticalModuleEntryAn entry in the module list.
EquipmentOpticalModuleEntry
.1.3.6.1.4.1.8708.2.11.2.10.1.1
equipmentOpticalModuleIndexAn arbitrary index assigned to each entry.ro
Unsigned32
.1.3.6.1.4.1.8708.2.11.2.10.1.1.1
equipmentOpticalModuleHostBoardTypeThe actual board type hosting the optical module.ro
EquipmentBoardType
.1.3.6.1.4.1.8708.2.11.2.10.1.1.2
equipmentOpticalModuleTypeThe type of optical module, for example monitor, switch, wss, amp etcro
MgmtNameString
.1.3.6.1.4.1.8708.2.11.2.10.1.1.3
equipmentOpticalModuleNameThe management name of the interface, for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'.ro
MgmtNameString
.1.3.6.1.4.1.8708.2.11.2.10.1.1.4
equipmentOpticalModuleSubrackThe number of the subrack where the module is located.ro
SubrackNumber
.1.3.6.1.4.1.8708.2.11.2.10.1.1.5
equipmentOpticalModuleSlotThe number of the slot where the module is located.ro
SlotNumber
.1.3.6.1.4.1.8708.2.11.2.10.1.1.6
equipmentOpticalModuleFirmwareVersionFirmware version of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.10.1.1.7
equipmentOpticalModuleSerialNumberSerial number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8708.2.11.2.10.1.1.8
equipmentOpticalModuleWarmingUpStateModule is warming up, the optics has not reached a stable state. True: Module is warming up. False: Module is ready and optics have reached stable state.ro
TruthValueWithNA
.1.3.6.1.4.1.8708.2.11.2.10.1.1.9
equipmentOpticalModuleFailureThe module is experiencing a failure. A(ctivation): The module has failed D(e-activation): The module is OK againro
FaultStatus
.1.3.6.1.4.1.8708.2.11.2.10.1.1.10
LUM-EQUIPMENT-MIB - SNMP MIB Reference | MIBs Explorer