LUM-IFOTN-MIB
AI MIB Summary
The LUM-IFOTN-MIB module manages Optical Transport Network (OTN) layer parameters compliant with ITU-T G.709, specifically monitoring and configuring Optical Channel Transport Unit (OTU), Optical Channel Data Unit (ODU), and Optical Channel Payload Unit (OPU) objects alongside tributary port attributes. This module facilitates the retrieval of operational status, performance counters, and configuration settings for OTN interfaces on Lumex (or compatible) optical transport hardware, excluding section, tandem connection, and performance monitoring data which are handled by the LUM-IFSMTCMPM-MIB.
The MIB module for management of otn parameters on objects. Notice! The SM, TCM and PM sections are described in LUM-IFSMTCMPM-MIB.txt
This module describes the otn layer in ITU-T Recommendation G.709.
The references refers to the following: G.709/Y.1331 (03/2003) G.798 (06/2004) G.806 (03/2006)
The tables contained in this MIB are:
(1) The General group contains some general attributes as time stamps and tables sizes.
(2) The optical channel transport unit (otu) group contains infor- mation and configuration for the Otu layer objects.
(3) The optical channel data unit (odu) group contains information and configuration for the Odu layer objects.
(4) The optical channel payload unit (opu) group contains information and configuration for the Opu layer objects.
(5) The tributary port (tp) group contains information and configuration for the tributary port.
Main OID:
lumIfOtnMIBModule.1.3.6.1.4.1.8708.1.1.50
75
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
75 total| Object Name |
|---|
lumIfOtnMIBModuleThe MIB module for management of otn parameters on objects.
Notice! The SM, TCM and PM sections are described in
LUM-IFSMTCMPM-MIB.txt
This module describes the otn layer in ITU-T Recommendation
G.709.
The references refers to the following:
G.709/Y.1331 (03/2003)
G.798 (06/2004)
G.806 (03/2006)
The tables contained in this MIB are:
(1) The General group contains some general attributes as time stamps
and tables sizes.
(2) The optical channel transport unit (otu) group contains infor-
mation and configuration for the Otu layer objects.
(3) The optical channel data unit (odu) group contains information
and configuration for the Odu layer objects.
(4) The optical channel payload unit (opu) group contains information
and configuration for the Opu layer objects.
(5) The tributary port (tp) group contains information
and configuration for the tributary port. MODULE-IDENTITY .1.3.6.1.4.1.8708.1.1.50 |
lumIfOtnConfs OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.1 |
lumIfOtnGroups OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.1.1 |
lumIfOtnCompl OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.1.2 |
lumIfOtnMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2 |
ifOtnGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2.1 |
ifOtnGeneralConfigLastChangeTimeThe time when the configuration of the MIB was
last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.1 |
ifOtnGeneralStateLastChangeTimeThe time when the state and/or configuration of the
MIB was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.2 |
ifOtnGeneralIfOtnOtuTableSizeSize of otn otu table.ro Unsigned32 .1.3.6.1.4.1.8708.2.50.2.1.3 |
ifOtnGeneralIfOtnOtuConfigLastChangeTimeThe time when the configuration of the table was
last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.4 |
ifOtnGeneralIfOtnOtuStateLastChangeTimeThe time when the state and/or configuration of the
table was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.5 |
ifOtnGeneralIfOtnOduTableSizeSize of otn odu tablero Unsigned32 .1.3.6.1.4.1.8708.2.50.2.1.6 |
ifOtnGeneralIfOtnOduConfigLastChangeTimeThe time when the configuration of the table was
last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.7 |
ifOtnGeneralIfOtnOduStateLastChangeTimeThe time when the state and/or configuration of the
MIB was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.8 |
ifOtnGeneralIfOtnOpuTableSizeSize of otn opu tablero Unsigned32 .1.3.6.1.4.1.8708.2.50.2.1.9 |
ifOtnGeneralIfOtnOpuConfigLastChangeTimeThe time when the configuration of the table was
last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.10 |
ifOtnGeneralIfOtnOpuStateLastChangeTimeThe time when the state and/or configuration of the
MIB was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.11 |
ifOtnGeneralIfOtnTpTableSizeSize of otn Tp tablero Unsigned32 .1.3.6.1.4.1.8708.2.50.2.1.12 |
ifOtnGeneralIfOtnTpConfigLastChangeTimeThe time when the configuration of the table was
last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.13 |
ifOtnGeneralIfOtnTpStateLastChangeTimeThe time when the state and/or configuration of the
MIB was last changed.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.1.14 |
ifOtnOtuList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2.2 |
ifOtnOtuTableThe optical channel transport unit (otu) group contains infor-
mation and configuration for the Otu layer objects. SEQUENCE OF IfOtnOtuEntry .1.3.6.1.4.1.8708.2.50.2.2.1 |
ifOtnOtuEntryAn entry in the ifOtn otu list. IfOtnOtuEntry .1.3.6.1.4.1.8708.2.50.2.2.1.1 |
ifOtnOtuIndexAn index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.50.2.2.1.1.1 |
ifOtnOtuNameThe management name of the otn otu, for example 'otu:1:2:1-2',
where the first number indicates subrack, the second slot
number and the third/fourth are the physical port numbers.ro MgmtNameString .1.3.6.1.4.1.8708.2.50.2.2.1.1.2 |
ifOtnOtuConnIfBasicIfIndexAn index that describes to which index in ifBasicIf table
this object is related.ro Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.3 |
ifOtnOtuTxSignalStatusThe state for outgoing (TX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.4 |
ifOtnOtuRxSignalStatusThe state for incoming (RX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.5 |
ifOtnOtuLossOfFrameLoss of frame (LOF).
Reference: 6.2.5.1 G.798
alarm: An OTU frame cannot be located.
ok: An OTU frame can be located.ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.6 |
ifOtnOtuRxAlarmIndicationSignalRx Alarm indication signal (AIS).
Indicates if alarm indication signal (AIS) alarm
exists or not in receiving direction.
Reference: 16.4 G.709, 6.2, 6.3.3 G.798
alarm: An AIS in OTU signal is detected.
ok: AIS inactive.ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.7 |
ifOtnOtuLossOfMultiframeLoss of multiframe (LOM).
Indicates loss of multiframe.
Reference: 6.2.5.2 G.798
A: Loss of multiframe is active.
D: Loss of multiframe inactive.ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.2.1.1.8 |
ifOtnOtuUpPortIdInternal port reference for traffic unit.ro Integer32 (-1..2147483647) .1.3.6.1.4.1.8708.2.50.2.2.1.1.9 |
ifOtnOduList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2.3 |
ifOtnOduTableThe optical channel data unit (odu) group contains information
and configuration for the Odu layer objects. SEQUENCE OF IfOtnOduEntry .1.3.6.1.4.1.8708.2.50.2.3.1 |
ifOtnOduEntryAn entry in the ifOtn odu list. IfOtnOduEntry .1.3.6.1.4.1.8708.2.50.2.3.1.1 |
ifOtnOduIndexAn index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.50.2.3.1.1.1 |
ifOtnOduNameThe management name of the otn odu, for example 'odu:1:2:1-2',
where the first number indicates subrack, the second slot
number and the third/fourth are the physical port numbers.rw MgmtNameString .1.3.6.1.4.1.8708.2.50.2.3.1.1.2 |
ifOtnOduConnIfBasicIfIndexAn index that describes to which index in ifBasicIf table
this object is related.rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.3 |
ifOtnOduGcc1TerminatedSet if GCC1 should be terminated or not.
true - GCC1 should be terminated
false - GCC1 should not be terminatedro TruthValueWithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.4 |
ifOtnOduGcc2TerminatedSet if GCC2 should be terminated or not.
true - GCC2 should be terminated
false - GCC2 should not be terminatedro TruthValueWithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.5 |
ifOtnOduUsedTcmsThis attribute indicates which ODU related TCMs
that has been created.
This is a bit-mask, where
0x00000000 means No TCM
0x00000001 means tcm1
0x00000010 means tcm2
...
0x00100000 means tcm6
...
0x00100010 means tcm2 + tcm6
...
0x00111111 means all tcms i.e. tcm1 ..tcm6rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.6 |
ifOtnOduTxSignalStatusThe state for outgoing (TX) signal
of the interface. This is reflecting
the signalStatus of the OTN PM object
and any terminated TCMs.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.7 |
ifOtnOduRxSignalStatusThe state for outgoing (RX) signal
of the interface. This is reflecting
the signalStatus of the OTN PM object
and any terminated TCMs.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.8 |
ifOtnOduTypeThe odu type.rw Enumeration .1.3.6.1.4.1.8708.2.50.2.3.1.1.9 |
ifOtnOduParentOduIndexAn index that describes to which index in ifOtnOduIf table
this SubOdu object is related.rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.3.1.1.10 |
ifOtnOpuList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2.4 |
ifOtnOpuTableThe optical channel payload unit (opu) group contains information
and configuration for the Opu layer objects. SEQUENCE OF IfOtnOpuEntry .1.3.6.1.4.1.8708.2.50.2.4.1 |
ifOtnOpuEntryAn entry in the ifOtn opu list. IfOtnOpuEntry .1.3.6.1.4.1.8708.2.50.2.4.1.1 |
ifOtnOpuIndexAn index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.50.2.4.1.1.1 |
ifOtnOpuNameThe management name of the otn opu, for example 'opu:1:2:1-2',
where the first number indicates subrack, the second slot
number and the third/fourth are the physical port numbers.ro MgmtNameString .1.3.6.1.4.1.8708.2.50.2.4.1.1.2 |
ifOtnOpuConnIfBasicIfIndexAn index that describes to which index in ifBasicIf table
this object is related.ro Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.3 |
ifOtnOpuTxSignalStatusThe state for outgoing (TX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.4 |
ifOtnOpuRxSignalStatusThe state for incoming (RX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.5 |
ifOtnOpuTxClientMaintenanceIndicationTx generic alarm indication signal (generic AIS).
Indicates if client maintenance signal (PN11)
exists or not.
alarm: A client maintenance signal is active.
ok: Client maintenance signal inactive.
Reference: 16.6.1 G.709/Y.1331ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.6 |
ifOtnOpuTxClientSignalFailTx Client signal fail (CSF).
Indicates if insignal in remote end is failed or not.
alarm: Remote end client is faulty.
ok: Remote end client is OK.
Reference: 17.1 G.709/Y.1331ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.7 |
ifOtnOpuRxPayloadMismatchRx Payload mismatch (PLM).
Monitored overhead: OPUk-PLM
Direction: Received from the associated physical interface and, unless the ODUk is terminated,
the PLM is sent towards the board-internal G.805 Matrix.
Reference 6.2.4.1 G.798
Values:
alarm: The OPUk-PLM overhead is declared as active if the incoming payload type is not equal to the expected payload type(s).
ok: The OPUk-PLM overhead is declared as inactive if the incoming payload type is equal to the expected payload type(s).ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.8 |
ifOtnOpuTxPayloadMismatchTx Payload mismatch (PLM).
Monitored overhead: OPUk-PLM
Direction: Received from the board-internal G.805 Matrix and, if applicable, sent towards the physical interface.
Reference 6.2.4.1 G.798
Values:
alarm: The OPUk-PLM overhead is declared as active if the incoming payload type is not equal to the expected payload type(s).
ok: The OPUk-PLM overhead is declared as inactive if the incoming payload type is equal to the expected payload type(s)ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.9 |
ifOtnOpuLossOfOpuMultiFrameIdentifierRx Loss of OPU Multi-frame identifier (LOOMFI).
Monitored overhead: OPU4 Multi-Frame Identifier
Direction: OPU4 Rx. If the expected 80-frame identifier goes out of
expected sequence for a period of > 3 ms, LOOMFI is declared.
Reference: 14.3.10.2 G.798
Values:
alarm: The OPU Multi-frame identifier is lost.
ok: The OPU Multi-frame identifier is present.ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.10 |
ifOtnOpuRxClientMaintenanceIndicationRx generic alarm indication signal (generic AIS).
Indicates if client maintenance signal (PN11)
exists or not.
alarm: A client maintenance signal is active.
ok: Client maintenance signal inactive.
Reference: 16.6.1 G.709/Y.1331ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.11 |
ifOtnOpuConnOduIndexAn index that describes to which index in Odu table
this object is related.ro Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.4.1.1.12 |
ifOtnTpList OBJECT IDENTIFIER .1.3.6.1.4.1.8708.2.50.2.5 |
ifOtnTpTableThe optical channel payload unit (tp) group contains information
and configuration for the Tp layer objects. SEQUENCE OF IfOtnTpEntry .1.3.6.1.4.1.8708.2.50.2.5.1 |
ifOtnTpEntryAn entry in the ifOtn tp list. IfOtnTpEntry .1.3.6.1.4.1.8708.2.50.2.5.1.1 |
ifOtnTpIndexAn index assigned to each entry.ro Unsigned32 .1.3.6.1.4.1.8708.2.50.2.5.1.1.1 |
ifOtnTpNameThe management name of the otn tp, for example 'tp:1:2:1',
where the first number indicates subrack, the second slot
number and the third is the tributary port number.rw MgmtNameString .1.3.6.1.4.1.8708.2.50.2.5.1.1.2 |
ifOtnTpConnIfBasicIfIndexAn index that describes to which index in the ifBasicIf table
this object is related.rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.3 |
ifOtnTpUsedTribSlotsThe number of tributary slots occupied by this tributary portro Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.4 |
ifOtnTpTribPortIdTributary port id.rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.5 |
ifOtnTpRxMultiplexStructureIdentifierMismatchRx Multiplex structure identifier mismatch (MSIM).
Indicates received MSI is not equal to expected MSI.
alarm: The MSIM shall be declared for the ODU tributary port
if the received MSI is not equal to the expected MSI.
ok: MSIM shall be cleared if the received MSI is equal to the
expected MSI.
reference 19.4.1 G709, 6.2.9.1 G.798ro FaultStatusWithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.6 |
ifOtnTpTxSignalStatusThe state for outgoing (TX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.7 |
ifOtnTpRxSignalStatusThe state for incoming (RX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.ro SignalStatusWithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.8 |
ifOtnTpXcRefOduIndexAn index that describes to which index in ifOtnOduIf table
this TP object is contained in.rw Unsigned32WithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.9 |
ifOtnTpTribSlotMaskTributary slot mask string
Format:
'<bit-mask>'rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.5.1.1.10 |
ifOtnTpTribSlotViewTributary slotsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8708.2.50.2.5.1.1.11 |
ifOtnTpNotAvailableForUseThe ifOtnTpTable is statically populated with entries
that may or may not be available for use depending on
other configuration items.
This attribute states whether the tributary port object
is actually possible to allocate or not.
TRUE => Not possible to allocate.
FALSE => Can be allocated.ro TruthValueWithNA .1.3.6.1.4.1.8708.2.50.2.5.1.1.12 |