LINKSYS-rndMng
AI MIB Summary
The LINKSYS-rndMng private MIB module facilitates the monitoring and management of Linksys RND series networking hardware, specifically providing access to general system management metrics such as device status, interface states, and resource utilization counters.
The private MIB module definition for RND general management MIB.
Main OID:
rndMng.1.3.6.1.4.1.89.1
39
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
39 total| Object Name |
|---|
rndMngThe private MIB module definition for RND general management MIB. MODULE-IDENTITY .1.3.6.1.4.1.89.1 |
rndSysIdIdentification of an RND device. The device type for each
integer clarifies the sysObjectID in MIB - II.ro INTEGER .1.3.6.1.4.1.89.1.1 |
rndActionThis variable enables the operator to perform one of the
specified actions on the tables maintained by the network device.
Send actions require support of proprietery File exchange
protocol.rw Enumeration .1.3.6.1.4.1.89.1.2 |
rndFileNameThe name of the file used internally by RND for transferring
tables maintained by network devices, using a prorietary File
exchange protocol.rw OCTET STRING -- SIZE 256 .1.3.6.1.4.1.89.1.3 |
rlSnmpVersionSupportedIndicates the snmp versions that are supported by
this device.ro OCTET STRING .1.3.6.1.4.1.89.1.4 |
rlSnmpMibVersionIndicates the snmp support version that is supported by
this device.ro INTEGER .1.3.6.1.4.1.89.1.5 |
rlCpuUtilEnableEnables measurement of the device CPU utilization.
In order to get real values for rlCpuUtilDuringLastSecond, rlCpuUtilDuringLastMinute
and rlCpuUtilDuringLast5Minutes, the value of this object must be true.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.1.6 |
rlCpuUtilDuringLastSecondPercentage of the device CPU utilization during last second.
The value 101 is a dummy value, indicating that the CPU utilization was
not measured (since measurement is disabled or was disabled during last second).ro INTEGER .1.3.6.1.4.1.89.1.7 |
rlCpuUtilDuringLastMinutePercentage of the device CPU utilization during last minute.
The value 101 is a dummy value, indicating that the CPU utilization was
not measured (since measurement is disabled or was disabled during last minute).ro INTEGER .1.3.6.1.4.1.89.1.8 |
rlCpuUtilDuringLast5MinutesPercentage of the device CPU utilization during the last 5 minutes.
The value 101 is a dummy value, indicating that the CPU utilization was
not measured (since measurement is disabled or was disabled during last 5 minutes).ro INTEGER .1.3.6.1.4.1.89.1.9 |
rlRebootDelaySetting the variable will cause the device to reboot rlRebootDelay timeticks
from the moment this variable was set.
If not set, the variable will return a value of 4294967295.
If set to 4294967295, reboot action is cancelled.
The maximum delay is set by the host parameter: reboot_delay_maxrw TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.89.1.10 |
rlGroupManagement OBJECT IDENTIFIER .1.3.6.1.4.1.89.1.11 |
rlGroupMngQuerySetting value query will cause the device to query for UPNP devices on the network.
The device will always return value idle for GET.rw Enumeration .1.3.6.1.4.1.89.1.11.1 |
rlGroupMngQueryPeriodSets desired interval between queries for UPNP devices on the network.
Setting 0 will result in no such query.
Note that the actual query interval might be less than the set value
if another application running in the device requested a shorter interval.
Likewise setting 0 will not necessarily stop periodic queries if another
application is still interested in periodic polling.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.89.1.11.2 |
rlGroupMngLastUpdateThe last time rlGroupMng MIB was updated.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.89.1.11.3 |
rlGroupMngDevicesTableThe table showing the discovered devices. SEQUENCE OF RlGroupMngDeviceEntry .1.3.6.1.4.1.89.1.11.4 |
rlGroupMngDeviceEntryThe row definition for this table. RlGroupMngDeviceEntry .1.3.6.1.4.1.89.1.11.4.1 |
rlGroupMngDeviceIdTypeThe IP address type of the discovered device InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.89.1.11.4.1.1 |
rlGroupMngDeviceIdThe IP address of the discovered device InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.89.1.11.4.1.2 |
rlGroupMngSubdeviceA subdevice within the rlGroupMngDeviceId. Only subdevices with greatest
specifity will be kept (specific UUID device is more specific than basic device which is in turn
more specific than root device. INTEGER .1.3.6.1.4.1.89.1.11.4.1.3 |
rlGroupMngDeviceDescriptionThe discovery protocol description of the device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.89.1.11.4.1.4 |
rlGroupMngGroupMngEnabledIndicates whether the device has Group Management enable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.1.11.4.1.5 |
rlGroupMngGroupLLDPDeviceIdThe LLDP device id. If it is empty the device id is not known (either it is a non-MTS device or a non-LLDP supporting MTS device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.89.1.11.4.1.6 |
rlGroupMngDeviceVendorThe vendor of the device. If empty the vendor is not known.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.89.1.11.4.1.7 |
rlGroupMngDeviceAdvertisedCachingTimeThe caching time advertised by the device. If no update for this
device has been received during this caching time the system will assume
that the device has left the network and will therefore remove its entry
from the table.ro INTEGER UNITS "seconds" .1.3.6.1.4.1.89.1.11.4.1.8 |
rlGroupMngDeviceLocationURLThe URL inidicating the location of the XML presenting the details of the device.ro DisplayString UNITS "seconds" .1.3.6.1.4.1.89.1.11.4.1.9 |
rlGroupMngDeviceLastSeenThe value of sysUpTime at the moment of last reception of an update for
this device.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.89.1.11.4.1.10 |
rlRunningCDBequalToStartupCDBIndicates whether there are changes in running CDB that were not saved in flash.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.1.13 |
rlClearMibClear MIB value for scalars or tables:
Delete all entries for tables with dynamic entries.
Set table entries default values for table with static entries.
Set scalar default value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.89.1.14 |
rlScheduledReloadUsed for requesting a delayed reload of the device in a
specific desired time, should be configured in one of the following formats:
'athhmmddMM' , 'inhhhmmm' or '', setting this value to an empty string
will result in request for cancellation of a (previously) committed system reload.
to complete the request, the 'rlScheduledReloadCommit' must also be set to either
TRUE (apply) or FALSE (discard) for completion of the transaction.
failing from doing so will result in an indefinite lock of the APIrw DisplayString .1.3.6.1.4.1.89.1.15 |
rlScheduledReloadPendingDateDisplays the most recently requested scheduled-reload due date
in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7).
if there is no pending/scheduled reload request, string will be emptyro DisplayString .1.3.6.1.4.1.89.1.16 |
rlScheduledReloadApprovedDateDisplays the most recently approved/committed scheduled-reload date
in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7).
if there is no committed scheduled-reload , string will be emptyro DisplayString .1.3.6.1.4.1.89.1.17 |
rlScheduledReloadCommitcommits the pending scheduled-reload request, and completes the transaction.
when this value is set to TRUE, the system is instructed to perform the
requested reload operation at the requested date/time
as was given in 'rlScheduledReload'.
setting this value to FALSE will discard the request.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.1.18 |
rlSysNameTableHolds the current system name configuration. SEQUENCE OF RlSysNameEntry .1.3.6.1.4.1.89.1.19 |
rlSysNameEntryThe row definition of this table. RlSysNameEntry .1.3.6.1.4.1.89.1.19.1 |
rlSysNameSourceThe system name source. 'static' if defined by user through CLI,
'dhcpv6' or 'dhcpv4' if received by DHCP network protocol. Enumeration .1.3.6.1.4.1.89.1.19.1.1 |
rlSysNameIfIndexThe IfIndex from which the system-name configuration was received,
for static entries, value will always be 1. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.89.1.19.1.2 |
rlSysNameNameAn administratively-assigned name for this managed node.
By convention, this is the node's fully-qualified domain
name. If the name is unknown, the value is the zero-length
string.rw DisplayString .1.3.6.1.4.1.89.1.19.1.3 |
rlSysNameRowStatusThe row status variable, used according to
row installation and removal conventions.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.89.1.19.1.4 |