LINKSYS-PHY-MIB
AI MIB Summary
The LINKSYS-PHY-MIB provides vendor-specific monitoring of Layer 1 physical interface parameters, including signal status, link state, and electrical characteristics, for Linksys networking hardware. This private MIB enables granular diagnostics of physical layer connectivity and hardware health beyond standard SNMP MIB-II capabilities.
The MIB module describes the private MIB for testing Layer1 interfaces supported by Linksys's software and products.
Main OID:
rlPhy.1.3.6.1.4.1.89.90
14
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
14 total| Object Name |
|---|
rlPhyThe MIB module describes the private MIB for testing Layer1 interfaces supported
by Linksys's software and products. MODULE-IDENTITY .1.3.6.1.4.1.89.90 |
IMPORTSThe MIB module describes the private MIB for testing Layer1 interfaces supported
by Linksys's software and products. Unknown .1.3.6.1.4.1.89.90 |
rlPhyTest OBJECT IDENTIFIER .1.3.6.1.4.1.89.90.1 |
rlPhyTestSetTable SEQUENCE OF RlPhyTestSetEntry .1.3.6.1.4.1.89.90.1.1 |
rlPhyTestSetEntryAn entry containing objects for invoking tests on an interface. RlPhyTestSetEntry .1.3.6.1.4.1.89.90.1.1.1 |
rlPhyTestSetTypeA control variable used to start operator initiated interface
tests.1 indicates that no test has been initiated. Only
operator initiated interface tests can be set to this variable.rw RlPhyTestType .1.3.6.1.4.1.89.90.1.1.1.1 |
rlPhyTestGetTable SEQUENCE OF RlPhyTestGetEntry .1.3.6.1.4.1.89.90.1.2 |
rlPhyTestGetEntryAn entry containing results of tests on an interface. RlPhyTestGetEntry .1.3.6.1.4.1.89.90.1.2.1 |
rlPhyTestGetTypeA control variable used to, 1 to indicate that this test can be
done on the specified port, 2 to initiate the test whenever the
user wishesro RlPhyTestType .1.3.6.1.4.1.89.90.1.2.1.1 |
rlPhyTestGetStatusThis object contains the status of the most recently
requested test for operator initiated tests or the value
none(1) if no tests have been requested since the last
reset. For non operator initiated tests the value is always
none(1).
Note that this facility provides no provision for saving
the results of one test when starting another, as could
be required if used by multiple managers concurrently.ro Enumeration .1.3.6.1.4.1.89.90.1.2.1.2 |
rlPhyTestGetResultThis object holds the test resultro INTEGER .1.3.6.1.4.1.89.90.1.2.1.3 |
rlPhyTestGetUnitsThe test result unit of measure. The units can be standard unit or special units
that are designed for special test.
The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).ro Enumeration .1.3.6.1.4.1.89.90.1.2.1.4 |
rlPhyTestGetAlarmThis object hold the Alarm for this Entry. only Test that have can have alarms
use this field, other holds the Value notRelevant(1)ro Enumeration .1.3.6.1.4.1.89.90.1.2.1.5 |
rlPhyTestGetTimeStampThe time in string (formated DD-MMM-YYYY HH:MM:SS e.g
14-Apr-2002 10:33:31)ro DisplayString .1.3.6.1.4.1.89.90.1.2.1.6 |