INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB enables SNMP-based monitoring and management of storage subsystems, including disk arrays, RAID controllers, and volume health status, on Intel Multi-Flex Server platforms. It exposes critical operational metrics such as drive temperature, I/O throughput, error counters, and RAID array state transitions to facilitate proactive infrastructure maintenance.
Imported Objects
Objects
85 total| Object Name |
|---|
multiFlexServerStorageMibModule MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.18 |
storageGroup Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.18 |
storage OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.208 |
interposer OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.208.1 |
interposerVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.1 |
interposerMfgDatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.2 |
interposerDeviceNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.3 |
interposerPartro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.4 |
interposerSerialNoro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.5 |
interposerMaximumPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.6 |
interposerNominalPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.7 |
interposerAssetTagro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.1.8 |
storageWWNro DisplayString .1.3.6.1.4.1.343.2.19.1.2.10.208.3 |
storageInterConnectionTypero Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.208.4 |
storagePoolTable SEQUENCE OF StoragePoolEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.5 |
storagePoolEntry StoragePoolEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1 |
poolIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.1 |
poolAliasro DisplayString .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.2 |
poolOperationalStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.3 |
poolConditionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.4 |
poolOperationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.5 |
poolPhysicalCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.6 |
poolConfigurableCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.7 |
poolFreeCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.8 |
poolMaxContiguousCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.9 |
poolMediaPatrolEnabledro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.10 |
poolPDMEnabledro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.11 |
poolNumOfPhysicalDrivesro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.12 |
poolNumOfVirtualDrivesro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.13 |
poolNumOfDedicatedSparesro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.14 |
poolPhysicalDriveIDsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.15 |
poolVirtualDriveIDsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.16 |
poolDedicatedSpareIDsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.17 |
poolWWNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.18 |
virtualDriveTable SEQUENCE OF VirtualDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.6 |
virtualDriveEntry VirtualDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1 |
virtDriveIdro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.1 |
virtDriveAliasro DisplayString .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.2 |
virtDriveSerialNoro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.3 |
virtDriveWWNro DisplayString .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.4 |
virtDriveOperationalStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.5 |
virtDriveConditionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.6 |
virtDriveOperationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.7 |
virtDriveSynchronizedro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.8 |
virtDriveRAIDLevelro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.9 |
virtDriveCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.10 |
virtDrivePhysicalCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.11 |
virtDriveStoragePoolIdro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.12 |
virtDriveNumOfAxelsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.13 |
virtDriveNumOfUsedPDro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.14 |
virtDriveSectorSizero Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.15 |
virtDrivePreferredScmIdro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.16 |
virtualDriveStatsTable SEQUENCE OF VirtualDriveStatsEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.7 |
virtualDriveStatsEntry VirtualDriveStatsEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1 |
virtDriveStatsDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.1 |
virtDriveStatsReadDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.2 |
virtDriveStatsWriteDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.3 |
virtDriveStatsNumOfErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.4 |
virtDriveStatsNumOfNonRWErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.5 |
virtDriveStatsNumOfReadErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.6 |
virtDriveStatsNumOfWriteErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.7 |
virtDriveStatsNumOfIORequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.8 |
virtDriveStatsNumOfNonRWRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.9 |
virtDriveStatsNumOfReadRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.10 |
virtDriveStatsNumOfWriteRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.11 |
virtDriveStatsStartTimero Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.12 |
virtDriveStatsCollectionTimero Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.7.1.13 |
spareDriveTable SEQUENCE OF SpareDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.8 |
spareDriveEntry SpareDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1 |
spareIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.1 |
spareOperationalStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.2 |
sparePhysicalDriveIdro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.3 |
sparePhysicalCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.4 |
spareConfigurableCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.5 |
spareRevertiblero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.6 |
spareTypero Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.7 |
spareNumOfAssociatedStoragePoolsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.8 |
spareAssociatedStoragePoolIDsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.9 |
spareDriveWWNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.8.1.10 |
vdb2lTable SEQUENCE OF VdB2lEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.9 |
vdb2lEntry VdB2lEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.9.1 |
vdb2Lunro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.208.9.1.1 |
bl2vdTable SEQUENCE OF Bl2vdEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.10 |
bl2vdEntry Bl2vdEntry .1.3.6.1.4.1.343.2.19.1.2.10.208.10.1 |
bl2vdVirtualDriveIdro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.208.10.1.1 |
INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB Technical Reference Overview
The INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB SNMP MIB module published by Intel defines 85 managed OID objects, including 70 scalar/column metrics, 6 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.18. Key tabular structures include bl2vdTable, spareDriveTable, storagePoolTable, vdb2lTable, virtualDriveStatsTable, virtualDriveTable.
Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB
.1.3.6.1.4.1.343.2.19.1.1.1.18Storage Module of the Multi-Flex Server
.1.3.6.1.4.1.343.2.19.1.2.10.208.10Blade/LUN to virtual drive mapping table. The table is doubly indexed given a blade slot and a LUN on that blade, it maps to an instance of a virtual drive id
.1.3.6.1.4.1.343.2.19.1.2.10.208.8A table of SpareDriveEntry.
.1.3.6.1.4.1.343.2.19.1.2.10.208.5Information about the storage pools
.1.3.6.1.4.1.343.2.19.1.2.10.208.9Virtual Drive to Blade/LUN mapping table. The table is doubly indexed given a instance of a virtual drive id and a blade slot, a specific LUN mapping for the virtual drive for that blade is provided.
.1.3.6.1.4.1.343.2.19.1.2.10.208.7A table of Virtual Drive Statistics.
.1.3.6.1.4.1.343.2.19.1.2.10.208.6A table of VirtualDriveEntry.
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.8Asset Tag # of device
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.3Device Name
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.6Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.2Manufacture date/time
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.7Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.4Device Part Number
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.5Device Serial Number
.1.3.6.1.4.1.343.2.19.1.2.10.208.1.1Device manufacturer
.1.3.6.1.4.1.343.2.19.1.2.2.2.18Description.
.1.3.6.1.4.1.343.2.19.1.2.10.208.4The Inter-Connection Type for the subystem
.1.3.6.1.4.1.343.2.19.1.2.10.208.3The World Wide Name of the subsystem (hexadecimal ID in 0, 8, or 16 bytes)
.1.3.6.1.4.1.343.2.19.1.2.10.208.10.1The parameters of a bl2vd drive.
.1.3.6.1.4.1.343.2.19.1.2.10.208.10.1.1Same as virtDriveId, but named differently so as not to cause namespace query conflicts. This is the associated virtual drive id given a blade slot and lun for the specified blade slot
.1.3.6.1.4.1.343.2.19.1.2.10.208.1IDROM information from the Interposer
.1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.2Alias of the Storage Pool.
.1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.4The condition of the Storage Pool. Currently not supported
.1.3.6.1.4.1.343.2.19.1.2.10.208.5.1.7The configurable capacity in bytes of the Storage Pool. It is the minimum configurable capacity of the physical drives in the storage pool mulitplies by the number of physical drives in the storage pool.
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module