Home/Catalog/INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB

INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB

AI MIB Summary

The INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB facilitates SNMP-based monitoring and management of Intel Multi-Flex Server blade chassis, exposing hardware telemetry such as blade presence, power status, temperature sensors, and fan health. This module enables centralized tracking of individual blade subsystems within a high-density server environment for fault isolation and capacity planning.

Blade Module of the Multi-Flex Server
Main OID:
multiFlexServerBladesMibModule.1.3.6.1.4.1.343.2.19.1.1.1.12
85
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

85 total
Object Name
multiFlexServerBladesMibModuleBlade Module of the Multi-Flex Server
MODULE-IDENTITY
.1.3.6.1.4.1.343.2.19.1.1.1.12
bladeGroupDescription.
Unknown
.1.3.6.1.4.1.343.2.19.1.2.2.2.12
maxBladesMaximum number of Blades possible in this chassis.ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.12
numOfBladesThe number of Blades in the system.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.22
bladePresenceMaskASCII representation of bit string reflecting the presence of the blades with the left most 'bit' being bit 1 and maxBlades bits being represented. Thus, '010011' would express that blades 2, 5, & 6 (of six blades) are presentro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.32
bladesContainer for Blade specific information as well as all components logically contained within.
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.202
bladeTableEach row describes a Blade in the chassis. Note, all blade rows possible for a chassis are present so that the presence field is accessible even when the blade is not.
SEQUENCE OF BladeEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.1
bladeEntryIndividual blade entry
BladeEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1
bladeSlotIdSlot number which the blade current occupies (or would occupy).ro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.1
bladePresencecolumn used to flag the existence of a particular FRUro
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.2
maxFrusGiven a board, the Maximum number of FRUs for this board. This parameter is related to the bladeFruPresenceMask as it defines the number of FRUs to be represented (whether they are present or not)ro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.3
numOfFrusThe number FRUs present on the boardro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.4
bladeFruPresenceMaskASCII representation of bit string reflecting the presence of the FRUs with the left most 'bit' being bit 1 and maxFrus bits being represented. bit 1 - blade, itself bit 2 - mez card Thus, '10' would express that the blade is present, but does not have a Mez card When indeterminate, the string will be emptyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.5
bladePowerLedState of the Power LED on the Blade (and optionally power control blade)rw
PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.6
bladeFaultLedState of the Fault LED on the Bladero
FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.7
bladePresenceLedState of the Presence LED on the Blade (and optionally intiate identification)rw
PresenceLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.8
bladeBmcFirmwareVersionTextual BMC Version of this blade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.9
bladeBootBlockVersionTextual Boot Block Version of this blade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.10
bladeBiosVersionTextual BIOS Version of this blade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.11
bladeConsoleRedirectionConsole redirection configuration within BIOSro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.12
bladeLegacyOsRedirectionLegacy OS Redirection configuration within BIOSro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.13
bladeBootCountNumber of times the blade has booted (since manufactured or NVRAM cleared) Will be 0 if unknown (e.g., blade hasn't been powered on at least once since insertion, blade not present, etc.).ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.14
bladeFruTableEach row describes a FRU associated with (and including) a Blade in the chassis There will always be 2 FRU entries for every blade (with the presence field marking whether marking whether the rest of the row is relevant). Thus, the presence can be queried of all FRUs regardless of their being present.
SEQUENCE OF BladeFruEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.2
bladeFruEntryblade & SubFRU common information.
BladeFruEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1
bladeFruTypecolumn used to identify a particular FRU. FRU 1 is the blade, itself, FRU 2 is the mezzanine cardro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.1
bladeFruPresencecolumn used to flag the existence of a particular FRUro
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.2
bladeFruVendorDevice manufacturerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.3
bladeFruMfgDateManufacture date/timero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.4
bladeFruDeviceNameDevice Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.5
bladeFruPartDevice Part Numberro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.6
bladeFruSerialNoDevice Serial Numberro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.7
bladeFruMaximumPowerStatic maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) 0xffff - Maximum power generation/consumption not known or specifiedro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.8
bladeFruNominalPowerStatic Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) 0xffff - Nominal power generation/consumption not known or specifiedro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.9
bladeFruAssetTagAsset Tag # of devicero
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.10
bladeNicTableEach row describes a NIC associated with a blade from the system memory as described by the blades SMBIOS entries. For future compatibility, this table is sparsely populate based on the presence of the blade, and the availability of the SMBIOS from the blade (e.g., a blade may be present, but if it never has powered on, or there is a communications error to the BMC, it may not be displayed)
SEQUENCE OF BladeNicEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.3
bladeNicEntryOverall NIC information per blade information
BladeNicEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.3.1
bladeNicNIC associated with blade (both onboard and optional Mezzanine card) as found within the SMBIOS data for the bladero
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.3.1.1
bladeProcessorTableEach row describes a Processor associated with a Blade in the chassis as described by the blades SMBIOS entries. As there are multiple Processors available per blade, there are two indices associated with this table. One for the blade, the other for the Processor in question. Although the blade is associated by slot within the chassis and is easily made a numeric value, the processor is less reliable. Although initial boards return via the BIOS the form 'CPU#', this is not required by the SMBIOS specification (it could be J2341). Thus, the SMBIOS handle associated with the processor is used so that cross referencing is more straight forward (e.g., when listing L caches associated with processors). For future compatibility, this table is sparsely populate based on the presence of the blade, and the availability of the SMBIOS from the blade (e.g., a blade may be present, but if it never has powered on, or there is a communications error to the BMC, it may not be displayed)
SEQUENCE OF BladeProcessorEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.4
bladeProcessorEntryProcessor(s) per blade information
BladeProcessorEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1
handleUnique handle within the SMBIOS table for a specific blade which lays out the assorted record types.
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.1
bladeProcessorSocketString returned by SMBIOS designating the socket location of the CPU for the indexed blade. The string is returned by the BIOS and is arbitrary as determined by the vendor. Thus it could be J202, or CPU2. Regardless, it will be unqiue in it's designation for a blade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.2
bladeProcessorPresencecolumn used to flag the existence of a particular CPUro
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.3
bladeProcessorTypeSMBIOS string representing type of Processor in this slotro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.4
bladeProcessorFamilyString representing SMBIOS data for the processor family typero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.5
bladeProcessorManufacturerString representing SMBIOS data for the Manufacturer of the Processorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.6
bladeProcessorIDSMBIOS string containing the Processor ID field which contains processor-specific information that describes the processor's features.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.7
bladeProcessorVersionString representing SMBIOS data describing the Processorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.8
bladeProcessorVoltageSMBIOS string representing the voltage(s) the processor is capable ofro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.9
bladeProcessorExtClockSMBIOS value of the External Clock Frequency, in MHZ. If the value is unknown, the field is set to 0ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.10
bladeProcessorMaxSpeedSMBIOS value of the Maximum processor speed (in MHz) supported by the system for this processor socket. If the value is unknown, the field is set to 0. Note: This field identifies a capability for the system, not the processor itself.ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.11
bladeProcessorStatusString representing SMBIOS data describing CPU status informationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.12
bladeProcessorUpgradeString representing SMBIOS data describing the CPU 'Upgrade' or how the processor is located on the bladero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.13
bladeProcessorSerialNoSMBIOS string of the serial number of this processor. This value is set by the manufactureer and normally not changeable.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.14
bladeProcessorAssetTagSMBIOS string of the asset tag of this processor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.15
bladeProcessorPartNoSMBIOS string of the part number of this processor. This value is set by the manufactureer and normally not changeable.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.16
bladeMemorySummaryTableEach row describes the overall summary of the memory configuration for a given blade in the chassis as described by the blades SMBIOS entries. For future compatibility, this table is sparsely populate based on the presence of the blade, and the availability of the SMBIOS from the blade (e.g., a blade may be present, but if it never has powered on, or there is a communications error to the BMC, it may not be displayed)
SEQUENCE OF BladeMemorySummaryEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.5
bladeMemorySummaryEntryOverall memory configuration summary per blade information
BladeMemorySummaryEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1
bladeMSMaxDevicesThe number of slots or sockets available for Memory Devices on the board.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.1
bladeMSNumOfDevicesThe number of slots or sockets populated with Memory Devices on the board.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.2
bladeMSCapacityThe maximum memory capacity in MB for this array.ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.3
bladeMSTotalSizeTotal size in MB of all memory physically installedro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.4
bladeMSEffectiveSizeMemory available after deducting for failed and redundant memory unitsro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.5
bladeMSNumFailedTotal Number of failed memory devicesro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.6
bladeMSDisabledSizeTotal size in MB of all disabled memoryro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.7
bladeMSSpareSizeTotal size in MB of all spare memory (see bladeMSRasPossible & bladeMSRasConfiguration columns)ro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.8
bladeMSRasPossibleRAS Configuration Possiblero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.9
bladeMSRasConfigurationRAS Configuration Possiblero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.10
bladeMSErrorCorrectionThe primary hardware error correction or detection method supportedro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.11
bladeMemoryTableEach row describes an individual memory device for system memory given a specific blade in the chassis as described by the blades SMBIOS entries. For future compatibility, this table is sparsely populate based on the presence of the blade, and the availability of the SMBIOS from the blade (e.g., a blade may be present, but if it never has powered on, or there is a communications error to the BMC, it may not be displayed)
SEQUENCE OF BladeMemoryEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.6
bladeMemoryEntryOverall memory device per blade information
BladeMemoryEntry
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1
bladeMemTotalWidthThe total width, in bits, of this memory device, including any check or error-correction bits. If there are no error-correction bits, this value should be equal to bladeMemDataWidth. If the width is unknown, the field is set to -1.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.1
bladeMemDataWidthThe data width, in bits, of this memory device. If 0 and bladeMemTotalWidth is 8 indicates that the device is being used solely to provide 8 error-correction bits. If the width is unknown, the field is set to -1.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.2
bladeMemSizeThe size of the memory device. If the value is 0, no memory device is installed in the socket (shouldn't occur as the table is sparsely populated); if the size is unknown, the field value is -1.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.3
bladeMemGranularityThe granularity of the bladeMemSizero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.4
bladeMemFormFactorThe implementation form factor for this memory device.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.5
bladeMemDeviceSetIdentifies when the Memory Device is one of a set of Memory Devices that must be populated with all devices of the same type and size and the set to which this device belongs. A value of 0 indicates that the device is not part of a set; a value of -1 indicates that the attribute is unknown.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.6
bladeMemLocationString that identifies the physically labeled socket or board position where the memory device is locatedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.7
bladeMemBankString that identifies the physically labeled bank where where the memory device is locatedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.8
bladeMemTypeThe type of memory used in this devicero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.9
bladeMemTypeDetailThe type of memory used in this devicero
Bits
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.10
bladeMemSpeedIdentifies the speed of the device in megahertz (MHz).ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.11
bladeMemManufacturerManufacturer of this memory devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.12
bladeMemSerialNoSerial Number of this memory devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.13
bladeMemAssetTagAsset Tag of this memory devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.14
bladeMemPartPart Number of this memory devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.15
INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB - SNMP MIB Reference | MIBs Explorer