Home/Catalog/INFINERA-ENTITY-CHASSIS-MIB

INFINERA-ENTITY-CHASSIS-MIB

AI MIB Summary

The INFINERA-ENTITY-CHASSIS-MIB provides SNMP-based management for the physical chassis inventory and status attributes of Infinera transport network equipment. It enables monitoring of chassis-level metrics including hardware component presence, slot occupancy, and physical device states within the managed infrastructure.

This MIB is modeling for CHASSIS equipment table.
Main OID:
chassisMIB.1.3.6.1.4.1.21296.2.2.2.1.13
63
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

63 total
Object Name
chassisMIBThis MIB is modeling for CHASSIS equipment table.
MODULE-IDENTITY
.1.3.6.1.4.1.21296.2.2.2.1.13
chassisTableThis table contains all chassis modules that are currently present in a network element.
SEQUENCE OF ChassisEntry
.1.3.6.1.4.1.21296.2.2.2.1.13.1
chassisEntryA row in the CHASSIS table. Each row in the table is identified with a unique entPhysicalIndexID.
ChassisEntry
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1
chassisMoIdThis is the primary Key of the objects e.g 1, 2, 3...rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.1
chassisProvChassisTypeThe provisioned chassis. Valid values: OTC, DTC, DTC-A, DTC-B, and MTC-A.rw
InfnChassisType (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.2
chassisInstalledChassisTypeThe installed chassis type.ro
InfnChassisType (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.3
chassisProvSerialNumberThe provisioned serial number of the Expansion Chassis. This field is configured for the expansion chassis in a multi-chassis configuration. This attribute can be modified only when the Admin State of the chassis (Expansion Chassis only) is Locked.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.4
chassisInstalledSerialNumberThe actual serial number of the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.5
chassisRackNameThe name of the rack in which the chassis is installed.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.6
chassisRUlocationInRackThe position of the chassis within the rack. The chassis with lower RU location is displayed at the bottom in the node view and the one with higher number is displayed at the top. If there are more than two chassis having the same rack name, they are displayed next to each other though they might be physically located in the same rack.rw
Unsigned32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.7
chassisSwitchCapabilityModeThe switch capability mode for the chassis. Valid values: ring and mesh.rw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.8
chassisInletTemperatureTemperature (in Centigrade) of the circuit pack at the inlet. The temperature is displayed as -1 if the circuit pack does not have a temperature sensor.ro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.9
chassisAcoStateThe chassis alarm cutoff state.rw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.10
chassisBayLevelSummaryAlarmReportingFlag that enables reporting of bay-level alarms. Typically, this is enabled for one chassis within a bay and disabled for all other chassis in the same bay. Vaid values:enabled and disabled.rw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.11
chassisConfiguredMaxPowerDrawThe estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration.rw
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.12
chassisCurrentEstimatedPowerDrawThe sum of estimated power drawn by all the currently installed and pre-provisioned FRUs in the chassis. This value is not indicative of the actual power drawn.ro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.13
chassisEqptMaxPowerDrawThe estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration.ro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.14
chassisScmMigrationAllowedThis objects indicate whether user can chnage the chassisSwitchCapabilityMode. If this is false user will not be able to chnage.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.15
chassisScmMigrationInProgressThis objects indicate that switch capability mode change is in progress.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.16
chassisPowerControlThis objects enable the auto power saving if pwoer is hitting the limit.ro
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.17
chassiscurrentInstalledPowerDrawThe estimated power drawn by the installed equipment in chassis. This varies depending on the type of the chassis and installed equipment.ro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.18
chassisConfiguredPemRatingThis attribute tells what is the compatible PEM rating for the chassis , in case of PEM-35 this attribute should be set to 35 and in case of PEM-70 it should be set to 70. Accordingly RatingAmps attribute of PEM will change and in case RatingAmps value of PEM doesn't matche with its InstalledRatingAmps then equipment mismatch alarm will be raised.rw
Unsigned32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.19
chassisRowStatusThe row status of this CHASSIS entry. Because rows in this table are indexed by entPhysicalIndex, to create a new row one must choose a value of entPhysicalIndex that is not already in use. A side-effect of the creation of a row in this table is the creation of a corresponding row in the eqptTable and the entPhysicalTable. The status may not be set to active if the chassisMoId, chassisProvEqptType and other read-create objects are not set to valid values. This row may only be deleted if it was a pre-provisioned row and the hardware is not present. If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be deleted by the agent.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.20
chassisIsNCChassiswhether or not this chassis houses the Node Controller XCM.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.21
chassisSwitchingModecurrent configuration of the chassis switch fabric module.ro
InfnChassisSwitchingMode
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.22
chassisMaxAvailablePowerMaximum available power in the chassisro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.23
chassisActvTimingSourcero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.24
chassisOperatingTemperatureThresholdrw
Integer32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.25
chassisConfiguredAmbientTemprw
Unsigned32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.26
chassisSkewBudgetrw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.27
chassisPduCktBreakerRatingrw
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.28
chassisRebootTimero
Integer32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.29
chassisCLEIro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.30
chassisHardwareVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.31
chassisManufacturedDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.32
chassisPartNumberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.33
chassisPONro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.34
chassisHolderTypero
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.35
chassisHolderStatero
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.36
chassisAcceptableEquipmentTypeListro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.37
chassisUnreachableFromManagementro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.38
chassisSerialPortCLIAccessrw
InfnEnableDisable (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.39
chassisAcliSessionAdminStaterw
InfnEnableDisable (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.40
chassisFruInsertionDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.41
chassisPowerSupplyTyperw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.42
chassisBaffleTyperw
Enumeration
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.43
chassisPmHistStatsEnablero
InfnPmHistStatsControl
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.44
chassisInletTemperatureOffsetInlet Temperature Offsetrw
FloatTenths (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.45
chassisHasPluggableEepromFlag to indicate if the device has pluggable Eepromro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.46
chassisPluggablePromSerialNumberPlugged in Eeprom serial numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.47
chassisOutletTemperatureThe outlet temperature of the chassisro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.48
chassisTTLMaxro
Integer32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.49
chassisTTLCurrentDaysro
Integer32
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.50
chassisAvailablePowerAvailable power in the chassisro
FloatArbitraryPrecision (INFINERA-TC-MIB)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.51
chassisSwitchFabricModecurrent configuration of the chassis switch fabric module.rw
InfnChassisOxmSwitchingMode
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.52
chassisPicDspVerPIC DSP Versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.53
chassisClientPowerModeselected client power moderw
InfnClientPowerMode
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.54
chassisClientPowerModeStatusclient power mode selectedro
InfnClientPowerMode
.1.3.6.1.4.1.21296.2.2.2.1.13.1.1.55
chassisConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.21296.2.2.2.1.13.3
chassisCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.21296.2.2.2.1.13.3.1
chassisCompliance
Unknown
.1.3.6.1.4.1.21296.2.2.2.1.13.3.1.1
chassisGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.21296.2.2.2.1.13.3.2
chassisGroup
Unknown
.1.3.6.1.4.1.21296.2.2.2.1.13.3.2.1