HUAWEI-VO-ANALOG-IF-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for HUAWEI-VO-ANALOG-IF-MIB.
Main OID:
hwVoiceAnalogInterfaceMIB.1.3.6.1.4.1.2011.5.25.1.3
55
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
55 total| Object Name |
|---|
hwVoiceAnalogInterfaceMIB MODULE-IDENTITY .1.3.6.1.4.1.2011.5.25.1.3 |
hwVoAnalogIfCommonObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.1.3.1 |
hwVoAnalogIfCommonConfigTableThe voice analog interface common configuration table contains information about configuration parameters for analog voice interface. SEQUENCE OF HWVoAnalogIfCommonConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.1.1 |
hwVoAnalogIfCommonConfigEntryAn entry in the voice analog interface common configuration table. The entry is automatically created when a analog voice interface hardware is found. HWVoAnalogIfCommonConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.1.1.1 |
hwVoAnalogIfConfigPortNumberIndex of voice analog interface common config table. It identify the number of the voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.1 |
hwVoAnalogIfConfigPortTypeThis object expresses the type of the voice analog interfaces. fxs : the type of the voice port is FXS. fxo : the type of the voice port is FXO. em : the type of the voice port is E&M.ro Enumeration .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.2 |
hwVoAnaloglfConfigPortImpedanceThis object expresses the port impedance of voice analog interfaces. impedance600Real : 600 Ohms This impedance is primarily used by FXS. impedanceComplex : 200 Ohms + 680 Ohms || 100nF This impedance is primarily used by FX0 and E&M.ro Enumeration .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.3 |
hwVoAnalogIfConfigInitialDigitTimeOutThis object states the longgest time to wait the first input digit from caller side. The default value is 10 seconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.4 |
hwVoAnalogIfConfigInterDigitTimeOutThis object states the longest time to wait between two input digit from caller side. The default value is 10 seconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.5 |
hwVoAnalogIfConfigCallDisconnectThis object states the time the system waits for the caller side to hang up after the connect is disable. The default value is 10 seconds.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.6 |
hwVoAnalogIfFXSObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.1.3.2 |
hwVoAnalogIfFXSConfigTableThe voice analog interface fxs configuration table contains information about configuration parameters for analog fxs voice interface. SEQUENCE OF HWVoAnalogIfFXSConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.2.1 |
hwVoAnalogIfFXSConfigEntryAn entry in the voice analog interface fxs configuration table. The entry is automatically created when a analog fxs voice interface hardware is found. HWVoAnalogIfFXSConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.2.1.1 |
hwVoAnalogIfFXSConfigPortNumberIndex of voice analog interface fxs config table. It identify the number of the fxs voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.2.1.1.1 |
hwVoAnalogIfFXSConfigStartModeThis object expresses the signaling type of analog fxs interface. The default value is loopStart.ro Enumeration .1.3.6.1.4.1.2011.5.25.1.3.2.1.1.2 |
hwVoAnalogIfFXSTimerTableThe voice analog interface fxs timer table contains information about timer parameters for analog fxs voice interface. SEQUENCE OF HWVoAnalogIfFXSTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.2.3 |
hwVoAnalogIfFXSTimerEntryAn entry in the voice analog interface fxs configuration table. The entry is automatically created when a analog fxs voice interface hardware is found. HWVoAnalogIfFXSTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.2.3.1 |
hwVoAnalogIfFXSTimerPortNumberIndex of voice analog interface fxs timer table. It identify the number of the fxs voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.2.3.1.1 |
hwVoAnalogIfFXSTimerDtmfThis object expresses outgoing dtmf digit duration of the analog fxs interface. The default value is 120 millisecondsro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.2.3.1.2 |
hwVoAnalogIfFXSTimerDtmfIntervalThis object expresses outgoing dtmf interval duration of the analog fxs interface. The default value is 120 millisecondsro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.2.3.1.3 |
hwVoAnalogIfFXOObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.1.3.3 |
hwVoAnalogIfFXOConfigTableThe voice analog interface fxo configuration table contains information about configuration parameters for analog fxo voice interface. SEQUENCE OF HWVoAnalogIfFXOConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.3.1 |
hwVoAnalogIfFXOConfigEntryAn entry in the voice analog interface fxo configuration table. The entry is automatically created when a analog fxo voice interface hardware is found. HWVoAnalogIfFXOConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.3.1.1 |
hwVoAnalogIfFXOConfigPortNumberIndex of voice analog interface fxo config table. It identify the number of the fxo voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.1 |
hwVoAnalogIfFXOConfigStartModeThis object expresses the signal type of analog fxo interface. The default value is fxoLoopStart.ro Enumeration .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.2 |
hwVoAnalogIfFXOConfigAlertNumberThis object expresses the number of rings detected before loop being closed. The default value is 2.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.3 |
hwVoAnalogIfFXOConfigAreaThis object expresses the busy tone of analog fxo interface. The default value is europe.rw Enumeration .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.4 |
hwVoAnalogIfFXOPreDialDelayThis object expresses the pre-dial delay of analog fxo interface. The default value is 1 seconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.5 |
hwVoAnaloglfFXOConfigPortImpedanceThis object expresses the port impedance of FXO interfaces.rw Enumeration .1.3.6.1.4.1.2011.5.25.1.3.3.1.1.6 |
hwVoAnalogIfFXOTimerTableThe voice analog interface fxo timer table contains information about timer parameters for analog fxo voice interface. SEQUENCE OF HWVoAnalogIfFXOTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.3.3 |
hwVoAnalogIfFXOTimerEntryAn entry in the voice analog interface fxo timer table. The entry is automatically created when a analog fxo voice interface hardware is found. HWVoAnalogIfFXOTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.3.3.1 |
hwVoAnalogIfFXOTimerPortNumberIndex of voice analog interface fxo timer table. It identify the number of the fxo voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.3.1.1 |
hwVoAnalogIfFXOTimerDtmfThis object expresses outgoing dtmf digit duration of the analog fxo interface. The default value is 120 millisecondsrw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.3.1.2 |
hwVoAnalogIfFXOTimerDtmfIntervalThis object expresses outgoing dtmf interval duration of the analog fxo interface. The default value is 120 millisecondsrw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.3.3.1.3 |
hwVoAnalogIfEMObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.1.3.4 |
hwVoAnalogIfEMConfigTableThe voice analog interface e&m configuration table contains information about configuration parameters for analog e&m voice interface. SEQUENCE OF HWVoAnalogIfEMConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.4.1 |
hwVoAnalogIfEMConfigEntryAn entry in the voice analog interface e&m configuration table. The entry is automatically created when a analog e&m voice interface hardware is found. HWVoAnalogIfEMConfigEntry .1.3.6.1.4.1.2011.5.25.1.3.4.1.1 |
hwVoAnalogIfEMConfigPortNumberIndex of voice analog interface e&m config table. It identify the number of the e&m voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.1 |
hwVoAnalogIfEMConfigSignalModeThis object expresses the signal mode of the analog e&m interfaces. The default value is immediateDial.rw Enumeration .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.2 |
hwVoAnalogIfEMConfigPhyParmThis object expresses the operation of the analog e&m signal. The default value of this object is fourWiresOperation.rw Enumeration .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.3 |
hwVoAnalogIfEMConfigPhyTypeThis object expresses the e&m lead signaling type of the analog e&m interface. The default is type5.rw Enumeration .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.4 |
hwVoAnalogIfEMConfigTimeoutRingingThis object expresses the ring timeout of the analog e&m interface. The value of 65535 indicates the timer is approach infinity. The default value of this object is 60 seconds.rw INTEGER (5..600 | 65535) .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.5 |
hwVoAnalogIfEMConfigTimeoutWaitDigitThis object expresses the wait digit timeout of the analog e&m interface. The value of 65535 indicates the timer is approach infinity. The default value of this object is 5 seconds.rw INTEGER (3..600 | 65535) .1.3.6.1.4.1.2011.5.25.1.3.4.1.1.6 |
hwVoAnalogIfEMTimerTableThe voice analog interface e&m timer table contains information about timer parameters for analog e&m voice interface. SEQUENCE OF HWVoAnalogIfEMTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.4.3 |
hwVoAnalogIfEMTimerEntryAn entry in the voice analog interface e&m timer table. The entry is automatically created when a analog e&m voice interface hardware is found. HWVoAnalogIfEMTimerEntry .1.3.6.1.4.1.2011.5.25.1.3.4.3.1 |
hwVoAnalogIfEMTimerPortNumberIndex of voice analog interface e&m timer table. It identify the number of the e&m voice port.ro INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.1 |
hwVoAnalogIfEMTimerDtmfThis object expresses outgoing dtmf digit duration of the analog e&m interface. The default value is 120 millisecondsrw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.2 |
hwVoAnalogIfEMTimerDtmfIntervalThis object expresses outgoing dtmf interval duration of the analog e&m interface. The default value is 120 millisecondsrw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.3 |
hwVoAnalogIfEMTimerCallIntervalThis object expresses the dureation of call clearing. The default value is 200 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.4 |
hwVoAnalogIfEMTimerSendWinkThis object expresses the max time between receiving seizure signal and sending wink signal. This object can olny be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 500 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.5 |
hwVoAnalogIfEMTimerWinkRisingThis object expresses the max time between sending seizure signal and receiving wink signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 2000 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.6 |
hwVoAnalogIfEMTimerWinkHoldThis object expresses the max duration for sending wink signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 500 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.7 |
hwVoAnalogIfEMTimerDialoutDelayThis object expresses max time sending called digits. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'immediate'. The default value is 300 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.8 |
hwVoAnalogIfEMTimerRisingThis object expresses the wait duration between receiveing seizure signal and sending delay signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'delayDial'. The default value is 300 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.9 |
hwVoAnalogIfEMTimerHoldThis object expresses the max time sending delay signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'delayDial'. The default value is 400 milliseconds.rw INTEGER .1.3.6.1.4.1.2011.5.25.1.3.4.3.1.10 |