HUAWEI-ND-MIB
The HUAWEI-ND-MIB module facilitates the monitoring and management of Huawei Network Device (ND) specific attributes, primarily tracking interface status, traffic statistics, and hardware component health across Huawei routers and switches. It provides standardized OID access for SNMP-based polling of critical network performance indicators and device operational states within Huawei enterprise infrastructure.
Imported Objects
Objects
27 total| Object Name |
|---|
hwNDMIBPlease provide the descritpion. MODULE-IDENTITY .1.3.6.1.4.1.2011.5.25.332 |
HUAWEI-MIBPlease provide the descritpion. Unknown .1.3.6.1.4.1.2011.5.25.332 |
hwNDObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.332.1 |
hwNDStatisticsPerSlotTableThis object indicates the threshold of the alarm generated in slot. SEQUENCE OF HwNDStatisticsPerSlotEntry .1.3.6.1.4.1.2011.5.25.332.1.1 |
hwNDStatisticsPerSlotEntryThis object indicates the threshold of the alarm generated in slot. HwNDStatisticsPerSlotEntry .1.3.6.1.4.1.2011.5.25.332.1.1.1 |
hwNDSlotPhysicalIndexThe slot of alarm generated.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.1 |
hwNDSlotThresholdExceedValueThis object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is greater than or equal to the alarm threshold.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.2 |
hwNDSlotThresholdResumeValueThis object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.3 |
hwNDSlotDynamicNumberCurrent dynamic ND entries in slot.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.4 |
hwNDSlotStaticNumberCurrent static ND entries in slot.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.5 |
hwNDSlotTotalNumberMaximum ND entries number for slot.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.1.1.6 |
hwNDStatisticsPerIfTableThis object indicates the threshold of the alarm generated in interface. SEQUENCE OF HwNDStatisticsPerIfEntry .1.3.6.1.4.1.2011.5.25.332.1.2 |
hwNDStatisticsPerIfEntryThis object indicates the threshold of the alarm generated in interface. HwNDStatisticsPerIfEntry .1.3.6.1.4.1.2011.5.25.332.1.2.1 |
hwNDIntfIndexThe interface of alarm generated.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.1 |
hwNDIntfThresholdExceedValueThis object indicates an ND entry alarm threshold on an interface. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is greater than or equal to the alarm threshold.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.2 |
hwNDIntfThresholdResumeValueThis object indicates an ND entry clear alarm threshold on an interface. An ND entry clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is less than or equal to the clear alarm threshold.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.3 |
hwNDIntfDynamicNumberCurrent dynamic ND entries in interface.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.4 |
hwNDIntfStaticNumberCurrent static ND entries in interface.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.5 |
hwNDIntfTotalNumberMaximum ND entries number for interface.ro Unsigned32 .1.3.6.1.4.1.2011.5.25.332.1.2.1.6 |
hwNDNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.332.2 |
hwSlotNDThresholdExceedAlarmThis object indicates that an alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is greater than or equal to the 80% threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.5.25.332.2.1 |
hwSlotNDThresholdResumeAlarmThis object indicates that a clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is less than or equal to the 70% threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.5.25.332.2.2 |
hwInterfaceNDThresholdExceedAlarmThis object indicates that an alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is greater than or equal to the 80% threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.5.25.332.2.3 |
hwInterfaceNDThresholdResumeAlarmThis object indicates that a clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is less than or equal to the 70% threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.5.25.332.2.4 |
hwNDConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.332.3 |
hwNDGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.332.3.1 |
hwNDCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2011.5.25.332.3.2 |
More MIBs from Huawei
Browse all HuaweiMIBs →The HUAWEI-MIB module provides a unified namespace for monitoring and managing generic system resources, interface statistics, and hardware telemetry across Huawei network devices. It serves as the foundational OID repository for retrieving standard operational data, including CPU utilization, memory usage, interface counters, and device status, required for comprehensive network management via SNMP.
Standard SNMP MIB module defining data structures for HUAWEI-SERVER-IBMC-MIB.
The HUAWEI-XPON-MIB module enables Network Management Systems to monitor and configure GPON and EPON optical line terminals and optical network units, specifically tracking PON port status, optical power levels, bandwidth allocation, and subscriber session states.
SNMP MIB module
The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.
The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.