Home/Catalog/HUAWEI-IFIT-MIB

HUAWEI-IFIT-MIB

AI MIB Summary

The HUAWEI-IFIT-MIB module enables Huawei network devices to generate and manage In-Service Flow Information Technology (IFIT) telemetry notifications, specifically monitoring real-time network performance metrics such as one-way delay, packet loss, and jitter across active traffic flows.

The mib is used for IFIT notifications.
Main OID:
hwIfit.1.3.6.1.4.1.2011.25.364
90
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

90 total
Object Name
hwIfitThe mib is used for IFIT notifications.
MODULE-IDENTITY
.1.3.6.1.4.1.2011.25.364
hwIfitObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1
hwFlowNumExceedObjectsInBoard
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.1
hwFlowNumExceedTableThe table is used to define variables in traps.
SEQUENCE OF HwFlowNumExceedEntry
.1.3.6.1.4.1.2011.25.364.1.1.1
hwFlowNumExceedEntryDefined the entries on which occurred IFIT flow reaches the upper limit.
HwFlowNumExceedEntry
.1.3.6.1.4.1.2011.25.364.1.1.1.1
hwIfitFlowExceedBoardThis object indicates the slot ID of the board.ro
DisplayString
.1.3.6.1.4.1.2011.25.364.1.1.1.1.1
hwIfitMaxFlowInBoardThis object indicates the max IFIT flow number in a board.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.1.1.1.2
hwIfitConfigObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.2
hwIfitStatsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.3
hwFlowNumExceedObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.4
hwDynFlowMidEgressNumExcTableThe table is used to define variables in traps.
SEQUENCE OF HwDynFlowMidEgressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.4.1
hwDynFlowMidEgressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit.
HwDynFlowMidEgressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.4.1.1
hwIfitMaxDynFlowMidEgressThis object indicates the max IFIT dynamic midegress flow number.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.4.1.1.1
hwInstanceExceedObjectsInBoard
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.5
hwInstanceExceedTableThe table is used to define variables in traps.
SEQUENCE OF HwInstanceExceedEntry
.1.3.6.1.4.1.2011.25.364.1.5.1
hwInstanceExceedEntryDefined the entries on which occurred IFIT flow reaches the upper limit.
HwInstanceExceedEntry
.1.3.6.1.4.1.2011.25.364.1.5.1.1
hwIfitInstanceTypeThis object indicates the type of the ifit instance.ro
DisplayString
.1.3.6.1.4.1.2011.25.364.1.5.1.1.1
hwIfitInstanceBoardThis object indicates the slot ID of the board.ro
DisplayString
.1.3.6.1.4.1.2011.25.364.1.5.1.1.2
hwIfitMaxInstanceInBoardThis object indicates the max IFIT instance number in a board.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.5.1.1.3
hwDynFlowIngressLimitObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.6
hwDynFlowIngressNumExcTableThe table is used to define variables in traps.
SEQUENCE OF HwDynFlowIngressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.6.1
hwDynFlowIngressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit.
HwDynFlowIngressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.6.1.1
hwIfitDynFlowIngressUpperLimitThis object indicates the IFIT total dynamic ingress flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.6.1.1.1
hwIngressLimitObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.7
hwIngressNumExcTableThe table is used to define variables in traps.
SEQUENCE OF HwIngressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.7.1
hwIngressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit.
HwIngressNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.7.1.1
hwIfitIngressUpperLimitThis object indicates the IFIT total ingress flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.7.1.1.1
hwMeasureFlowLimitObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.8
hwMeasureFlowNumExcTableThe table is used to define measurement flow specifications.
SEQUENCE OF HwMeasureFlowNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.8.1
hwMeasureFlowNumExcEntryDefined the measurement flow specifications entries.
HwMeasureFlowNumExcEntry
.1.3.6.1.4.1.2011.25.364.1.8.1.1
hwIfitMeasureFlowNodeTypeThis object indicates the measurement flow node type.ro
OCTET STRING
.1.3.6.1.4.1.2011.25.364.1.8.1.1.1
hwIfitMeasureFlowTypeThis object indicates the measurement flow type.ro
OCTET STRING
.1.3.6.1.4.1.2011.25.364.1.8.1.1.2
hwIfitMeasureFlowUpperLimitThis object indicates the measurement flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.8.1.1.3
hwFlowNumAlmostExceedObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.9
hwDynFlowMidEgressNumAlmostExcTableThe table is used to define variables in traps.
SEQUENCE OF HwDynFlowMidEgressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.9.1
hwDynFlowMidEgressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit.
HwDynFlowMidEgressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.9.1.1
hwIfitDynFlowMidEgressMaxLimitThis object indicates the max IFIT dynamic midegress flow number.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.9.1.1.1
hwDynFlowIngressAlmostExceedObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.10
hwDynFlowIngressNumAlmostExcTableThe table is used to define variables in traps.
SEQUENCE OF HwDynFlowIngressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.10.1
hwDynFlowIngressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit.
HwDynFlowIngressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.10.1.1
hwIfitDynFlowIngressMaxLimitThis object indicates the IFIT total dynamic ingress flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.10.1.1.1
hwIngressAlmostExceedObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.11
hwIngressNumAlmostExcTableThe table is used to define variables in traps.
SEQUENCE OF HwIngressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.11.1
hwIngressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit.
HwIngressNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.11.1.1
hwIfitIngressMaxLimitThis object indicates the IFIT total ingress flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.11.1.1.1
hwMeasureFlowAlmostExceedObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.1.12
hwMeasureFlowNumAlmostExcTableThe table is used to define measurement flow specifications.
SEQUENCE OF HwMeasureFlowNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.12.1
hwMeasureFlowNumAlmostExcEntryDefined the measurement flow specifications entries.
HwMeasureFlowNumAlmostExcEntry
.1.3.6.1.4.1.2011.25.364.1.12.1.1
hwMeasureFlowNodeTypeThis object indicates the measurement flow node type.ro
OCTET STRING
.1.3.6.1.4.1.2011.25.364.1.12.1.1.1
hwMeasureFlowTypeThis object indicates the measurement flow type.ro
OCTET STRING
.1.3.6.1.4.1.2011.25.364.1.12.1.1.2
hwMeasureFlowMaxLimitThis object indicates the measurement flow number upper limit.ro
Integer32
.1.3.6.1.4.1.2011.25.364.1.12.1.1.3
hwIfitNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2
hwFlowNumExceedTrapInBoard
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.1
hwIfitStaticFlowNumExceedAlarmThe total number of IFIT static flows and reverse flows in the board reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.1
hwIfitStaticFlowNumExceedResumeThe total number of IFIT static flows and reverse flows in the board has been lower than the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.2
hwIfitDynamicFlowNumExceedAlarmThe total number of IFIT dynamic flows in the board reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.3
hwIfitDynamicFlowNumExceedResumeThe total number of IFIT dynamic flows in the board has been lower than the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.4
hwIfitExceedInstanceAlarmThe total number of IFIT instances on the interface board reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.5
hwIfitExceedInstanceAlarmResumeThe total number of IFIT instances on the interface board has been lower the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.1.6
hwDynFlowMidEgressNumExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.2
hwIfitDynFlowMidEgressNumExceedAlarmThe total number of IFIT dynamic flows in the machine reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.2.1
hwIfitDynFlowMidEgressNumExceedResumeThe total number of IFIT dynamic flows in the machine has been lower than the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.2.2
hwDynFlowIngressNumExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.3
hwIfitDynFlowIngressNumExceedAlarmThe number of IFIT dynamic ingress flow reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.3.1
hwIfitDynFlowIngressNumExceedResumeThe number of IFIT dynamic ingress flow is below the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.3.2
hwIngressNumExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.4
hwIfitIngressNumExceedAlarmThe number of IFIT ingress flow reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.4.1
hwIfitIngressNumExceedResumeThe number of IFIT ingress flow is below the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.4.2
hwMeasureFlowNumExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.5
hwIfitMeasureFlowNumExceedAlarmThe number of IFIT measurement flow reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.5.1
hwIfitMeasureFlowNumExceedResumeThe number of IFIT measurement flow is below the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.5.2
hwSlaDataTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.6
hwIfitmcpSlaDataAlarmIFITMCP has not been generating SLA data for a noticeable period of time.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.6.1
hwIfitmcpSlaDataResumeIFITMCP is generating SLA data now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.6.2
hwDynFlowMidEgressNumAlmostExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.7
hwIfitDynFlowMidEgressNumAlmostExceedAlarmThe total number of IFIT dynamic flows in the machine almost reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.7.1
hwIfitDynFlowMidEgressNumAlmostExceedResumeThe total number of IFIT dynamic flows in the machine is below 80% of the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.7.2
hwDynFlowIngressNumAlmostExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.8
hwIfitDynFlowIngressNumAlmostExceedAlarmThe number of IFIT dynamic ingress flows almost reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.8.1
hwIfitDynFlowIngressNumAlmostExceedResumeThe number of IFIT dynamic ingress flows is below 80% of the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.8.2
hwIngressNumAlmostExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.9
hwIfitIngressNumAlmostExceedAlarmThe number of IFIT ingress flows almost reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.9.1
hwIfitIngressNumAlmostExceedResumeThe number of IFIT ingress flows is below 80% of the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.9.2
hwMeasureFlowNumAlmostExcTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.2.10
hwIfitMeasureFlowNumAlmostExceedAlarmThe number of IFIT measurement flows almost reaches the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.10.1
hwIfitMeasureFlowNumAlmostExceedResumeThe number of IFIT measurement flows is below 80% of the upper limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.25.364.2.10.2
hwIfitTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.3
hwIfitTrapObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.3.1
hwIfitConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.4
hwIfitGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.25.364.4.1
HUAWEI-IFIT-MIB - SNMP MIB Reference | MIBs Explorer