HUAWEI-IFIT-MIB
The HUAWEI-IFIT-MIB module enables Huawei network devices to generate and manage In-Service Flow Information Technology (IFIT) telemetry notifications, specifically monitoring real-time network performance metrics such as one-way delay, packet loss, and jitter across active traffic flows.
Imported Objects
Objects
90 total| Object Name |
|---|
hwIfitThe mib is used for IFIT notifications. MODULE-IDENTITY .1.3.6.1.4.1.2011.25.364 |
hwIfitObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1 |
hwFlowNumExceedObjectsInBoard OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.1 |
hwFlowNumExceedTableThe table is used to define variables in traps. SEQUENCE OF HwFlowNumExceedEntry .1.3.6.1.4.1.2011.25.364.1.1.1 |
hwFlowNumExceedEntryDefined the entries on which occurred IFIT flow reaches the upper limit. HwFlowNumExceedEntry .1.3.6.1.4.1.2011.25.364.1.1.1.1 |
hwIfitFlowExceedBoardThis object indicates the slot ID of the board.ro DisplayString .1.3.6.1.4.1.2011.25.364.1.1.1.1.1 |
hwIfitMaxFlowInBoardThis object indicates the max IFIT flow number in a board.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.1.1.1.2 |
hwIfitConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.2 |
hwIfitStatsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.3 |
hwFlowNumExceedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.4 |
hwDynFlowMidEgressNumExcTableThe table is used to define variables in traps. SEQUENCE OF HwDynFlowMidEgressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.4.1 |
hwDynFlowMidEgressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit. HwDynFlowMidEgressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.4.1.1 |
hwIfitMaxDynFlowMidEgressThis object indicates the max IFIT dynamic midegress flow number.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.4.1.1.1 |
hwInstanceExceedObjectsInBoard OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.5 |
hwInstanceExceedTableThe table is used to define variables in traps. SEQUENCE OF HwInstanceExceedEntry .1.3.6.1.4.1.2011.25.364.1.5.1 |
hwInstanceExceedEntryDefined the entries on which occurred IFIT flow reaches the upper limit. HwInstanceExceedEntry .1.3.6.1.4.1.2011.25.364.1.5.1.1 |
hwIfitInstanceTypeThis object indicates the type of the ifit instance.ro DisplayString .1.3.6.1.4.1.2011.25.364.1.5.1.1.1 |
hwIfitInstanceBoardThis object indicates the slot ID of the board.ro DisplayString .1.3.6.1.4.1.2011.25.364.1.5.1.1.2 |
hwIfitMaxInstanceInBoardThis object indicates the max IFIT instance number in a board.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.5.1.1.3 |
hwDynFlowIngressLimitObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.6 |
hwDynFlowIngressNumExcTableThe table is used to define variables in traps. SEQUENCE OF HwDynFlowIngressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.6.1 |
hwDynFlowIngressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit. HwDynFlowIngressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.6.1.1 |
hwIfitDynFlowIngressUpperLimitThis object indicates the IFIT total dynamic ingress flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.6.1.1.1 |
hwIngressLimitObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.7 |
hwIngressNumExcTableThe table is used to define variables in traps. SEQUENCE OF HwIngressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.7.1 |
hwIngressNumExcEntryDefined the entries on which occurred IFIT flow reaches the upper limit. HwIngressNumExcEntry .1.3.6.1.4.1.2011.25.364.1.7.1.1 |
hwIfitIngressUpperLimitThis object indicates the IFIT total ingress flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.7.1.1.1 |
hwMeasureFlowLimitObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.8 |
hwMeasureFlowNumExcTableThe table is used to define measurement flow specifications. SEQUENCE OF HwMeasureFlowNumExcEntry .1.3.6.1.4.1.2011.25.364.1.8.1 |
hwMeasureFlowNumExcEntryDefined the measurement flow specifications entries. HwMeasureFlowNumExcEntry .1.3.6.1.4.1.2011.25.364.1.8.1.1 |
hwIfitMeasureFlowNodeTypeThis object indicates the measurement flow node type.ro OCTET STRING .1.3.6.1.4.1.2011.25.364.1.8.1.1.1 |
hwIfitMeasureFlowTypeThis object indicates the measurement flow type.ro OCTET STRING .1.3.6.1.4.1.2011.25.364.1.8.1.1.2 |
hwIfitMeasureFlowUpperLimitThis object indicates the measurement flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.8.1.1.3 |
hwFlowNumAlmostExceedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.9 |
hwDynFlowMidEgressNumAlmostExcTableThe table is used to define variables in traps. SEQUENCE OF HwDynFlowMidEgressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.9.1 |
hwDynFlowMidEgressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit. HwDynFlowMidEgressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.9.1.1 |
hwIfitDynFlowMidEgressMaxLimitThis object indicates the max IFIT dynamic midegress flow number.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.9.1.1.1 |
hwDynFlowIngressAlmostExceedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.10 |
hwDynFlowIngressNumAlmostExcTableThe table is used to define variables in traps. SEQUENCE OF HwDynFlowIngressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.10.1 |
hwDynFlowIngressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit. HwDynFlowIngressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.10.1.1 |
hwIfitDynFlowIngressMaxLimitThis object indicates the IFIT total dynamic ingress flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.10.1.1.1 |
hwIngressAlmostExceedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.11 |
hwIngressNumAlmostExcTableThe table is used to define variables in traps. SEQUENCE OF HwIngressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.11.1 |
hwIngressNumAlmostExcEntryDefined the entries on which occurred IFIT flow almost reaches the upper limit. HwIngressNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.11.1.1 |
hwIfitIngressMaxLimitThis object indicates the IFIT total ingress flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.11.1.1.1 |
hwMeasureFlowAlmostExceedObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.1.12 |
hwMeasureFlowNumAlmostExcTableThe table is used to define measurement flow specifications. SEQUENCE OF HwMeasureFlowNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.12.1 |
hwMeasureFlowNumAlmostExcEntryDefined the measurement flow specifications entries. HwMeasureFlowNumAlmostExcEntry .1.3.6.1.4.1.2011.25.364.1.12.1.1 |
hwMeasureFlowNodeTypeThis object indicates the measurement flow node type.ro OCTET STRING .1.3.6.1.4.1.2011.25.364.1.12.1.1.1 |
hwMeasureFlowTypeThis object indicates the measurement flow type.ro OCTET STRING .1.3.6.1.4.1.2011.25.364.1.12.1.1.2 |
hwMeasureFlowMaxLimitThis object indicates the measurement flow number upper limit.ro Integer32 .1.3.6.1.4.1.2011.25.364.1.12.1.1.3 |
hwIfitNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2 |
hwFlowNumExceedTrapInBoard OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.1 |
hwIfitStaticFlowNumExceedAlarmThe total number of IFIT static flows and reverse flows in the board reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.1 |
hwIfitStaticFlowNumExceedResumeThe total number of IFIT static flows and reverse flows in the board has been lower than the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.2 |
hwIfitDynamicFlowNumExceedAlarmThe total number of IFIT dynamic flows in the board reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.3 |
hwIfitDynamicFlowNumExceedResumeThe total number of IFIT dynamic flows in the board has been lower than the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.4 |
hwIfitExceedInstanceAlarmThe total number of IFIT instances on the interface board reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.5 |
hwIfitExceedInstanceAlarmResumeThe total number of IFIT instances on the interface board has been lower the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.1.6 |
hwDynFlowMidEgressNumExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.2 |
hwIfitDynFlowMidEgressNumExceedAlarmThe total number of IFIT dynamic flows in the machine reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.2.1 |
hwIfitDynFlowMidEgressNumExceedResumeThe total number of IFIT dynamic flows in the machine has been lower than the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.2.2 |
hwDynFlowIngressNumExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.3 |
hwIfitDynFlowIngressNumExceedAlarmThe number of IFIT dynamic ingress flow reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.3.1 |
hwIfitDynFlowIngressNumExceedResumeThe number of IFIT dynamic ingress flow is below the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.3.2 |
hwIngressNumExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.4 |
hwIfitIngressNumExceedAlarmThe number of IFIT ingress flow reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.4.1 |
hwIfitIngressNumExceedResumeThe number of IFIT ingress flow is below the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.4.2 |
hwMeasureFlowNumExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.5 |
hwIfitMeasureFlowNumExceedAlarmThe number of IFIT measurement flow reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.5.1 |
hwIfitMeasureFlowNumExceedResumeThe number of IFIT measurement flow is below the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.5.2 |
hwSlaDataTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.6 |
hwIfitmcpSlaDataAlarmIFITMCP has not been generating SLA data for a noticeable period of time. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.6.1 |
hwIfitmcpSlaDataResumeIFITMCP is generating SLA data now. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.6.2 |
hwDynFlowMidEgressNumAlmostExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.7 |
hwIfitDynFlowMidEgressNumAlmostExceedAlarmThe total number of IFIT dynamic flows in the machine almost reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.7.1 |
hwIfitDynFlowMidEgressNumAlmostExceedResumeThe total number of IFIT dynamic flows in the machine is below 80% of the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.7.2 |
hwDynFlowIngressNumAlmostExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.8 |
hwIfitDynFlowIngressNumAlmostExceedAlarmThe number of IFIT dynamic ingress flows almost reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.8.1 |
hwIfitDynFlowIngressNumAlmostExceedResumeThe number of IFIT dynamic ingress flows is below 80% of the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.8.2 |
hwIngressNumAlmostExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.9 |
hwIfitIngressNumAlmostExceedAlarmThe number of IFIT ingress flows almost reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.9.1 |
hwIfitIngressNumAlmostExceedResumeThe number of IFIT ingress flows is below 80% of the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.9.2 |
hwMeasureFlowNumAlmostExcTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.2.10 |
hwIfitMeasureFlowNumAlmostExceedAlarmThe number of IFIT measurement flows almost reaches the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.10.1 |
hwIfitMeasureFlowNumAlmostExceedResumeThe number of IFIT measurement flows is below 80% of the upper limit. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.25.364.2.10.2 |
hwIfitTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.3 |
hwIfitTrapObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.3.1 |
hwIfitConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.4 |
hwIfitGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2011.25.364.4.1 |
More MIBs from Huawei
Browse all HuaweiMIBs →The HUAWEI-MIB module provides a unified namespace for monitoring and managing generic system resources, interface statistics, and hardware telemetry across Huawei network devices. It serves as the foundational OID repository for retrieving standard operational data, including CPU utilization, memory usage, interface counters, and device status, required for comprehensive network management via SNMP.
Standard SNMP MIB module defining data structures for HUAWEI-SERVER-IBMC-MIB.
The HUAWEI-XPON-MIB module enables Network Management Systems to monitor and configure GPON and EPON optical line terminals and optical network units, specifically tracking PON port status, optical power levels, bandwidth allocation, and subscriber session states.
SNMP MIB module
The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.
The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.