HUAWEI-ENERGYMNGT-MIB
AI MIB Summary
The HUAWEI-ENERGYMNGT-MIB enables SNMP-based monitoring and management of power consumption, voltage, current, and temperature metrics on Huawei network infrastructure devices. It facilitates the collection of energy efficiency data and environmental sensor readings to support power capacity planning and thermal management.
huawei energy management MIB.
Main OID:
hwEnergyMngt.1.3.6.1.4.1.2011.6.157
60
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
60 total| Object Name |
|---|
hwEnergyMngthuawei energy management MIB. MODULE-IDENTITY .1.3.6.1.4.1.2011.6.157 |
hwSysPowerMgnt OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.1 |
hwPowerConsumptionNE total power consumption, counted from equipment first used.
Joule(Watt * second).
Note: If the device is a power supplier(PSE), the power consumption includes the outputs.ro Counter64 .1.3.6.1.4.1.2011.6.157.1.1 |
hwPowerStatPeriodNE power statistics period:
fifteenMinutes(1): The power statistics generated every 15 minutes.
thirtyMinutes(2): The power statistics generated every 30 minutes.
oneHour(3): The power statistics generated every hour.
oneDay(4): The power statistics generated every day.
oneWeek(5): The power statistics generated every week.
oneMonth(6): The power statistics generated every month.
The defaut statistics intervalue is one hour.rw Enumeration .1.3.6.1.4.1.2011.6.157.1.2 |
hwAveragePowerNE average power consumtion during a period: milliwattro Integer32 .1.3.6.1.4.1.2011.6.157.1.3 |
hwRatedPowerNE rated power: milliwattro Integer32 .1.3.6.1.4.1.2011.6.157.1.4 |
hwThresholdOfPowerNE threshold power: milliwattrw Integer32 .1.3.6.1.4.1.2011.6.157.1.5 |
hwCurrentPowerNE current power: milliwattro Integer32 .1.3.6.1.4.1.2011.6.157.1.6 |
hwPoETypepowered type:
PSE(1): power supplier.
PD(2): powered deivce.
noPoe(255): not PSE or PDro Enumeration .1.3.6.1.4.1.2011.6.157.1.7 |
hwPSEPowerThe output power(milliwatt) by a PSE. For a non-PSE device, the value is zero.ro Integer32 .1.3.6.1.4.1.2011.6.157.1.8 |
hwBoardPowerMngt OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.2 |
hwBoardPowerMngtTableThis table describes current power and rated power of boards. The index is hwBoardIndex. SEQUENCE OF HwBoardPowerMngtEntry .1.3.6.1.4.1.2011.6.157.2.1 |
hwBoardPowerMngtEntryThe entry of hwBoardPowerMngtTable. HwBoardPowerMngtEntry .1.3.6.1.4.1.2011.6.157.2.1.1 |
hwBoardIndexIndex: reserved/shelf/frame/slot.
The index is format by 4 bytes(8bit for 1 byte): reservedByte(0xFF), shelfID, frameID, slotID.
e.g. shlef=1, frame=2, slot=17, the index is 0xFF010211(66065).
If no shelfID or frameID, the corresponding byte is set to be 0xFF.
e.g. no shlefID, no frameID, slot=17, the index is 0xFFFFFF11(4294967057).ro Integer32 .1.3.6.1.4.1.2011.6.157.2.1.1.1 |
hwBoardTypehwBoardType describes main type of board: LPU/SFU/ADSL/PSTN, etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.6.157.2.1.1.2 |
hwBoardNamehwBoardName describes full name of board: CR52LPUA/CR57SFU40A/H805ADGG, etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.6.157.2.1.1.3 |
hwBoardCurrentPowercurrent power of board(slot): milliwattro Integer32 .1.3.6.1.4.1.2011.6.157.2.1.1.4 |
hwBoardRatedPowerrated power of board(slot): milliwattro Integer32 .1.3.6.1.4.1.2011.6.157.2.1.1.5 |
hwBoardThresholdOfPowerThreshold power of board(slot): milliwattrw Integer32 .1.3.6.1.4.1.2011.6.157.2.1.1.6 |
hwEnergySavingMngt OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.3 |
hwEnergySavingModePower saving mode:
UserDefined(1): UserDined energy-saving mode, user can define energy-saving strategy.
Standard(2): standard energy-saving mode
Basic(3): basic energy-saving mode, many basic energy-saving strategy included.
Deep(4): Deep energy-saving mode, many complex energy-saving strategy included, which may effect service.rw Enumeration .1.3.6.1.4.1.2011.6.157.3.1 |
hwEnergySavingMethodTablehwEnergySavingMethodTable defines energy-saving Method for all mode.
User can set a method with its parameter.
The index of this table is hwEnergySavingMethodIndex. SEQUENCE OF HwEnergySavingMethodEntry .1.3.6.1.4.1.2011.6.157.3.2 |
hwEnergySavingMethodEntryEntry of energy-saveing method table. HwEnergySavingMethodEntry .1.3.6.1.4.1.2011.6.157.3.2.1 |
hwEnergySavingMethodIndexThe index of method in use.ro Integer32 .1.3.6.1.4.1.2011.6.157.3.2.1.1 |
hwEnergySavingMethodEnablehwEnergySaveingMethodEnable describes the status of energy-saving method: enableed or disabled.rw Enumeration .1.3.6.1.4.1.2011.6.157.3.2.1.2 |
hwEnergySavingParameterTablehwEnergySavingParameterTable defines parameters for all energy-saving methods.
User can set parameter for a method.
The index of this table: hwEnergySavingMethodIndex, hwEnergySavingParameterIndex. SEQUENCE OF HwEnergySavingParameterEntry .1.3.6.1.4.1.2011.6.157.3.3 |
hwEnergySavingParameterEntryEntry of energy-saveing parameter table. HwEnergySavingParameterEntry .1.3.6.1.4.1.2011.6.157.3.3.1 |
hwEnergySavingParameterIndexThe second index of hwEnergySavingParameterTable.
An energy-saving method might have more than one parameter.
This index is used to identify the parameter for a method.ro Integer32 .1.3.6.1.4.1.2011.6.157.3.3.1.1 |
hwEnergySavingParameterValueThe value of an energy-saveing method's parameter.
The parameter is a format string.
When NMS sets integer 12 as a parameter for a energy-saving method, the value is a string '12'.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.6.157.3.3.1.2 |
hwEnergySavingCapabilityMngtTableThis table describes the energy-saving capability, including energy-saving methods and parameters.
The index is hwEnergySavingCapabilityDescIndex. SEQUENCE OF HwEnergySavingCapabilityMngtEntry .1.3.6.1.4.1.2011.6.157.3.4 |
hwEnergySavingCapabilityMngtEntryThe entry of hwBoardPowerMngtTable. HwEnergySavingCapabilityMngtEntry .1.3.6.1.4.1.2011.6.157.3.4.1 |
hwEnergySavingCapabilityDescIndexThe index of hwEnergySavingCapabilityMngtTable.ro Integer32 .1.3.6.1.4.1.2011.6.157.3.4.1.1 |
hwEnergySavingCapabilityDescLanguageThe language of EnergySavingCapabilityDescription file.
'en-gb'(English-GreatBraitain)
'zh-cn'(Chinese)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.6.157.3.4.1.2 |
hwEnergySavingCapabilityDescUser can get the description string from hwEnergySavingCapabilityDesc.
An XML file which is compressed by ZIP to less than 10240 bytes,
describes the energy-saving capability, including all energy-saving methods and parameters.ro OCTET STRING .1.3.6.1.4.1.2011.6.157.3.4.1.3 |
hwEnergySavingDescReqModeThe mode describes how to get energy saving capability description file :
snmp(1): Get the file using hwEnergySavingCapabilityDesc.
ftp(2): Get the file using FTP, which described by hwEnergyFtpclientReqTable.ro Enumeration .1.3.6.1.4.1.2011.6.157.3.5 |
hwEnergyFtpcObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.4 |
hwEnergyFtpcTransFileTableThis table is used to configure transfer file feature related parameters. SEQUENCE OF HwEnergyFtpcTransFileEntry .1.3.6.1.4.1.2011.6.157.4.1 |
hwEnergyFtpcTransFileEntryName identifying Transfer configuration HwEnergyFtpcTransFileEntry .1.3.6.1.4.1.2011.6.157.4.1.1 |
hwEnergyFtpcSetNameName identifying FTPC Transfer configuration OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.1 |
hwEnergyFtpcSrcAddrTypeSource IP address Type:
ipv4(1)
ipv6(2)rw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.6.157.4.1.1.2 |
hwEnergyFtpcSrcAddrSource IP addressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.6.157.4.1.1.3 |
hwEnergyFtpcVpnNameVPN name used for the corresponding connectionrw OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.4 |
hwEnergyFtpcHostAddrTypeServer address type:
ipv4(1)
ipv6(2)rw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.6.157.4.1.1.5 |
hwEnergyFtpcHostAddrServer IP addressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.6.157.4.1.1.6 |
hwEnergyFtpcServerPortServer port used for connectionrw Integer32 (21 | 1025..55535) .1.3.6.1.4.1.2011.6.157.4.1.1.7 |
hwEnergyFtpcUserNameUser Name used for user validationrw OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.8 |
hwEnergyFtpcPasswordPassword used for user validation. Password Length while setting should not be more than
16 characters, while querying password will be cipher textrw OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.9 |
hwEnergyFtpcDirectoryLocal working directoryrw OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.10 |
hwEnergyFtpcSrcIfNameInterface Namerw OCTET STRING .1.3.6.1.4.1.2011.6.157.4.1.1.11 |
hwEnergyFtpcTransCfgRowStatusThe object specifies the status of this table
entry. When the status is createAndGo, it
allows to create and when value is destroy
it allows to delete the record in the tablerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2011.6.157.4.1.1.12 |
hwEnergyFtpcActionThe type of request.
get(1): To request a file from the FTP server.
put(2): To send a file to the FTP server.rw Enumeration .1.3.6.1.4.1.2011.6.157.4.1.1.13 |
hwEnergyFtpcTransModeThe file transfer protocol. Default: FTP.rw Enumeration .1.3.6.1.4.1.2011.6.157.4.1.1.14 |
hwEnergyFtpOperStatusThe OperStatus:
opInProgress(1): the operation is in process.
opSuccess(2): the operation has been completed successfully.
opInvalid(3): the command is invalid or command-protocol-device combination is unsupported by the system.
opInvalidProtocol(4): invalid protocol is specified
opInvalidSourceName(5) :invalid source file name is specified.
opInvalidDestName(6): invalid target name is specified.
opInvalidServerAddress(7): invalid server address is specified
opDeviceBusy(8): the device is in use and locked by another process
opDeviceError(9): device read, write or erase error
opFileOpenError(10) :invalid file name; file not found in partition
opFileTransferError(11) :file transfer was unsuccessfull
opFileChecksumError(12) :file checksum in Flash is invalid
opAuthFail(13) :authentication failure
opUnknownFailure(14) :failure which is unknown
opAbort(15) : transfer operation has been aborted
opInvalidSourceAddress(16): invalid source IP is specified.
opInvalidSourceInterface(17): invalid source interface is specified.ro Enumeration .1.3.6.1.4.1.2011.6.157.4.1.1.15 |
hwEnergyConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.6 |
hwEnergyCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.6.1 |
hwEnergyGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.6.2 |
hwEnergyTrapObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.10 |
hwEnergyDevIdThis object identifies the device ID.ro Integer32 .1.3.6.1.4.1.2011.6.157.10.1 |
hwEnergyNotification OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.157.11 |
hwEnergyDevChangeToSleepThis notification indicates device entering in the sleeping status. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.6.157.11.1 |