Home/Catalog/HUAWEI-COMMTEST-MIB

HUAWEI-COMMTEST-MIB

AI MIB Summary

The HUAWEI-COMMTEST-MIB enables remote management of copper twisted-pair line diagnostics on Huawei service boards by executing metallic line tests (MELT), querying test results and calibration data, and controlling searching tone operations to verify physical layer connectivity integrity.

This MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board to the phone set is normal. Common MELT operations include starting a MELT test, querying the test result, querying the calibration data, and starting and stopping a searching tone test.
Main OID:
hwTestCommon.1.3.6.1.4.1.2011.6.21.1
385
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

385 total
Object Name
hwTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21
hwTestCommonThis MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board to the phone set is normal. Common MELT operations include starting a MELT test, querying the test result, querying the calibration data, and starting and stopping a searching tone test.
MODULE-IDENTITY
.1.3.6.1.4.1.2011.6.21.1
hwTestCommonMib
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.1
hwTestCommonMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.1.1
hwTestGroupOprTableTable of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this table is hwTestGroupNo.
SEQUENCE OF HwTestGroupOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.1
hwTestGroupOprEntryTable of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this entry is hwTestGroupNo.
HwTestGroupOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1
hwTestGroupNoTest group number. The MD5500 supports the number that ranges from 0 to 240. The MA5100 supports the number that ranges from 0 to 4. The MA5300 supports the number that ranges from 0 to 63.
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.1
hwTestBoardIfIndexTest board IfIndex.rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.2
hwTestGroupAssistIfIndexTestGroupAssist port IfIndex.rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.3
hwTestGroupAssistTelNoAssistant telephone number. The maximum length is 16 Octets.rw
OCTET STRING
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.4
hwTestGroupRowStatusPresent operation status of a row. Options: 1. active(1), -the present operation status of the row is active 2. notInService(2), -the present operation status of the row is notInService 3. notReady(3), -the present operation status of the row is notReady 4. createAndGo(4), -the present operation status of the row is createAndGo 5. createAndWait(5), -the present operation status of the row is createAndWait 6. destroy(6) -the present operation status of the row is destroyrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.5
hwLoopLineTestOprTableThis table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this table is ifindex.
SEQUENCE OF HwLoopLineTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.2
hwLoopLineTestOprEntryThis table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this entry is ifindex.
HwLoopLineTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1
hwLoopLineTestOprTypeMELT operation type Options: 1. stop(1) -stop a MELT test 2. start(2) -start a MELT test 3. invalid(-1) -invalid valuerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.1
hwLoopLineTestVoltageIndicates whether a voltage exists on the line under test. Options: 1. notest(1) -the voltage does not exist on the line under test 2. test(2) -the voltage exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.2
hwLoopLineTestResistanceIndicates whether resistance exists on the line under test. Options: 1. notest(1) -resistance does not exist on the line under test 2. test(2) -resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.3
hwLoopLineTestCapacitanceIndicates whether capacitance exists on the line under test. Options: 1. notest(1) -capacitance does not exist on the line under test 2. test(2) -capacitance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.4
hwLoopLineTestLoopResistanceIndicates whether loop resistance exists on the line under test. Options: 1. notest(1) -loop resistance does not exist on the line under test 2. test(2) -loop resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.5
hwLoopLineTestPoleResistanceIndicates whether pole resistance exists on the line under test. Options: 1. notest(1) -Pole resistance does not exist on the line under test 2. test(2) -Pole resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.6
hwLoopLineTestBusyProcFlagIdentify whether to start a test when the line is busy. The system will excecute a corresponding operation according to the configuration that a user specifies, for example, to cancel the test or to force to test. Options: 1. busyNoTest(1) -perform no test when a port is busy 2. busyTest(2) -perform a remedy test when a port is busy 3. busystrenTest(3) -force to test when a port is busy 4. deferredTest(4) -defer a test when a port is busy 5. invalid(-1) -invalid value Default: busyTest(1) If the value of this leaf is deferredTest(4), both hwLoopLineTestDeferredTime and hwLoopLineTestTimeoutProc must be set.rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.7
hwLoopLineTestStatusIndicates the result of MELT test. Options: 1. normal(1) -the MELT test is successful 2. testFail(2) -the MELT test fails 3. portBusy(3) -the MELT test port is busy 4. testOutOfTime(4) -the MELT test times out 5. testingAbnormal(5) -the MELT test is abnormal 6. broadbandtesting(6)-the MELT test is broadbandtesting 7. capturefail(7) -the MELT test fails to capture 8. notratb(8) -the relay transfer board of the MELT test does not exist 9. testcanceled(9) -the MELT test is canceled 10. invalid(-1) -invalid valuero
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.8
hwLoopLineTestConclusionMELT test conclusion Options: 1. normal(1) -the test conclusion is normal 2. meetLine(2) -the test conclusion is meetLine 3. aLineMix(3) -the test conclusion is aLineMix 4. bLineMix(4) -the test conclusion is bLineMix 5. doubleMix(5) -the test conclusion is doubleMix 6. aLineEarth(6) -the test conclusion is aLineEarth 7. bLineEarth(7) -the test conclusion is bLineEarth 8. doublelineearth(8) -the test conclusion is doublelineearth 9. selfMix(9) -the test conclusion is selfMix 10. abLine(10) -the test conclusion is abLine 11. aLineFree(11) -the test conclusion is aLineFree 12. bLineEarthFree(12) -the test conclusion is bLineEarthFree 13. doubleLineEarthFree(13) -the test conclusion is doubleLineEarthFree 14. abLineFree(14) -the test conclusion is abLineFree 15. killLine(15) -the test conclusion is killLine 16. noPutDownTele(16) -the test conclusion is noPutDownTele 17. unknow(17) -the test conclusion is unknow 18. selfMixinMDF(18) -the test conclusion is selfMixinMDF 19. selfMixoutMDF(19) -the test conclusion is selfMixoutMDF 20. cutLineinMDF(20) -the test conclusion is cutLineinMDF 21. cutLineoutMDF(21) -the test conclusion is cutLineoutMDF 22. dCvoltagePowerFeed(30) -the test conclusion is dCvoltagePowerFeed 23. aCvoltageRinging(31) -the test conclusion is aCvoltageRinging 24. dCvoltageOffhook(32) -the test conclusion is dCvoltageOffhook 25. dCvoltage(33) -the test conclusion is dCvoltage 26. aCvoltage(34) -the test conclusion is aCvoltage 27. abImpedance(35) -the test conclusion is abImpedance 28. baImpedance(36) -the test conclusion is baImpedance 29. agImpedance(37) -the test conclusion is agImpedance 30. bgImpedance(38) -the test conclusion is bgImpedance 31. agACCurrent(39) -the test conclusion is agACCurrent 32. bgACCurrent(41) -the test conclusion is bgACCurrent 33. abACCurrent(42) -the test conclusion is abACCurrent 34. agDCCurrent(43) -the test conclusion is agDCCurrent 35. bgDCCurrent(44) -the test conclusion is bgDCCurrent 36. abDCCurrent(45) -the test conclusion is abDCCurrent 37. loopCurrent(46) -the test conclusion is loopCurrent 38. noise(47) -the test conclusion is noise 39. abRFaultId(91) -the test conslusion is ab Line all fault 40. aRFaultId(92) -the test conslusion is a Line fault 41. bRFaultId(93) -the test conslusion is b Line fault 42. abLeakId(94) -the test conslusion is ab Line all leak 43. aLeakId(95) -the test conslusion is a Line leak 44. bLeakId(96) -the test conslusion is b line leak 45. abFvacLevelH(97) -the test conslusion is ab dangerous AC to ground 46. aFvacLevelH(98) -the test conslusion is a dangerous AC to ground 47. bFvacLevelH(99) -the test conslusion is b dangerous AC to ground 48. abFvacLevelI(100) -the test conslusion is ab EMF AC to ground 49. aFvacLevelI(101) -the test conslusion is a EMF AC to ground 50. bFvacLevelI(102) -the test conslusion is b EMF AC to ground 51. abFvacLevelO(103) -the test conslusion is ab other dangerous AC to ground 52. aFvacLevelO(104) -the test conslusion is a other dangerous AC to ground 53. bFvacLevelO(105) -the test conslusion is b other dangerous AC to ground 54. abFvDcLevelH(106) -the test conslusion is ab dangerous DC to ground 55. aFvDcLevelH(107) -the test conslusion is a dangerous DC to ground 56. bFvDcLevelH(108) -the test conslusion is b dangerous DC to ground 57. abFvDcLevelI(109) -the test conslusion is ab EMF DC to ground 58. aFvDcLevelI(110) -the test conslusion is a EMF DC to ground 59. bFvDcLevelI(111) -the test conslusion is b EMF DC to ground 60. abFvDcLevelO(112) -the test conslusion is ab other dangerous DC to ground 61. aFvDcLevelO(113) -the test conslusion is a other dangerous DC to ground 62. bFvDcLevelO(114) -the test conslusion is b other dangerous DC to ground 63. fesIdPPA(115) -the test conslusion is ab PPA 64. fesIdPPAInv(116) -the test conslusion is ab reverse PPA 65. fesId2PPA(117) -the test conslusion is ab two PPA 66. fesId2PPAInv(118) -the test conslusion is ab two reverse PPA 67. etsiXdslSignature(119) -the test conslusion is ETSI XDSL Signature 68. fetIdEr(120) -the test conslusion is exist electronic ring terminal 69. abreak(121) -the test conslusion is a line break 70. bbreak(122) -the test conslusion is b line break 71. abreakInMDF(123) -the test conslusion is a line break InMDF 72. bbreakInMDF(124) -the test conslusion is b line break InMDF 73. abreakOutMDF(125) -the test conslusion is a line break OutMDF 74. bbreakOutMDF(126) -the test conslusion is b line break OutMDF 75. invalid(-1) -the test conclusion is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.9
hwLoopLineTestACAGIndicates the A->ground AC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.10
hwLoopLineTestACBGIndicates the B->ground AC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.11
hwLoopLineTestACABIndicates the A->B AC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.12
hwLoopLineTestDCAGIndicates the A->ground DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.13
hwLoopLineTestDCBGIndicates the B->ground DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.14
hwLoopLineTestDCABIndicates the A->B DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.15
hwLoopLineTestRAGIndicates the A->ground insulation resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.16
hwLoopLineTestRBGIndicates the B->ground insulation resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.17
hwLoopLineTestRABIndicates the A->B insulation resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.18
hwLoopLineTestCapAGIndicates the A->ground capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.19
hwLoopLineTestCapBGIndicates the B->ground capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.20
hwLoopLineTestCapABIndicates the A->B capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.21
hwLoopLineTestLRIndicates the loop resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.22
hwLoopLineTestRABResPoleIndicates the A->B polarity reversal resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.23
hwLoopLineTestMSocketIndicates the M-socket connection. Options: 1. notconnected(1) -the M-socket is not connected 2. connected(2) -the M-socket is connected 3. aBReversed(3) -the wire A and wire B are reversedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.24
hwLoopLineTestBtssPowerProcFlagLoop line test-BTSS line with power processing. Options: 1. noTest(1) -not test 2. test(2) -test 3. invalid(-1) -invalid valuerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.25
hwLoopLineTestImpedanceLoop line test-impedance. Options: 1. notest(1) -not test 2. test(2) -testrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.26
hwLoopLineTestImpedanceABA->B impedance (unit: ohm)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.27
hwLoopLineTestImpedanceBAB->A impedance (unit: ohm)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.28
hwLoopLineTestImpedanceAGA->ground impedance (unit: ohm)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.29
hwLoopLineTestImpedanceBGB->ground impedance (unit: ohm)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.30
hwLoopLineTestCurrentLoop line test-current. Options: 1. notest(1) -not test 2. test(2) -testrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.31
hwLoopLineTestACCurrentAGA->ground AC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.32
hwLoopLineTestACCurrentBGB->ground AC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.33
hwLoopLineTestACCurrentABAB AC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.34
hwLoopLineTestDCCurrentAGA->ground DC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.35
hwLoopLineTestDCCurrentBGB->ground DC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.36
hwLoopLineTestDCCurrentABAB DC current (unit: mA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.37
hwLoopLineTestLoopCurrentLoop line test-loop current. Options: 1. notest(1) -not test 2. test(2) -testrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.38
hwLoopLineTestLCLoop current (unit: uA)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.39
hwLoopLineTestNoiseLoop line test-noise. Options: 1. notest(1) -not test 2. test(2) -testrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.40
hwLoopLineTestNNoise (unit: dBm)ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.41
hwLoopLineTestPPAIndicates whether PPA exists on the line under test. Options: 1. notest(1) -PPA does not exist on the line under test 2. test(2) -PPA exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.42
hwLoopLineTestPPAResultIndicates whether the PPA exists. Options: 1. noexist(1) -PPA does not exist 2. exist(2) -PPA exists 3. inverseexist(3) -PPA inverse exists 4. invalid(-1) -invalid valuero
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.43
hwLoopLineTestDeferredTimeIndicates the deferred time. Unit: minute This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4). Default: 30rw
Integer32(-1 | 1..1440)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.44
hwLoopLineTestTimeoutProcIndicates the timeout processing. Options: 1. notest(1) -if the deferred time times out and the port is still busy the test will be canceled 2. test(2) -if the deferred time times out and the port is still busy the test will be forcedly started 3. invalid(-1) -invalid value This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4).rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.45
hwLoopLineTestReverseReverse flag (0:normal test 1:reverse test)rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.46
hwLoopLineTestUtgAcFreqFrequency of foreign AC voltage source coupled to tip via Zbat_tip impedance. Unit: Hzro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.47
hwLoopLineTestUrgAcFreqFrequency of foreign AC voltage source coupled to ring via Zbat_ring impedance. Unit:Hzro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.48
hwLoopLineTestUtrAcFreqFrequency of foreign AC voltage source coupled to tip-ring via Zbat_tipring impedance. Unit:Hzro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.49
hwLoopLineTestItipAcAC foreign current on the tip wire. Unit:uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.50
hwLoopLineTestIringAcAC foreign current on the ring wire. Unit:uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.51
hwLoopLineTestItipDcDC foreign current on the tip wire. Unit:uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.52
hwLoopLineTestIringDcDC foreign current on the ring wire. Unit:uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.53
hwLoopLineTestRbattipIn presence of a foreign voltage, the equivalent coupling resistance of wire A. Unit:ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.54
hwLoopLineTestRbatringIn presence of a foreign voltage, the equivalent coupling resistance of wire B. Unit:ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.55
hwLoopLineTestRringResistance in series with the ring capacitance, for example when a ringer load or a passive R-C signature terminates the loop. It also includes the cable resistance R line but it does not include the 24 k feeding resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.56
hwLoopLineTestCsigCapacitance of an xDSL signal. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.57
hwLoopLineTestVzenerZener diode threshold in the case of an off-hook phone. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.58
hwLoopLineTestRzenerDC tip-ring resistance measured in the case of an off-hook phone. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.59
hwLoopLineTestGtgAggregate a->ground conductance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.60
hwLoopLineTestBtgAggregate a->ground susceptance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.61
hwLoopLineTestGrgAggregate b->ground conductance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.62
hwLoopLineTestBrgAggregate b->ground susceptance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.63
hwLoopLineTestGtrAggregate a->b conductance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.64
hwLoopLineTestBtrAggregate a->b susceptance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.65
hwLoopLineTestSIGNIndicates the ETSI xDSL Signature is detected or not.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.66
hwLoopLineTestACFEMIndicates the presence of an AC foreign voltage above the threshold defined by ACFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.67
hwLoopLineTestDCFEMIndicates the presence of a DC foreign voltage above the threshold defined by DCFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.68
hwLoopLineTestONHKIndicates the presens of a phone in the on-hook state.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.69
hwLoopLineTestOPENIndicates a->b resistance exceeds the threshold.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.70
hwLoopLineTestSHORTIndicates that the insulation resistance is small.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.71
hwLoopLineTestROHIndicates a phone in the off-hook state.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.72
hwLoopLineTestUtgDcUpIndicates the a->ground highest measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.73
hwLoopLineTestUtgDcDownIndicates the a->ground lowest measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.74
hwLoopLineTestUrgDcUpIndicates the b->ground highest measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.75
hwLoopLineTestUrgDcDownIndicates the b->ground lowest measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.76
hwLoopLineTestUtrPosIndicates the a->b positive measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.77
hwLoopLineTestUtrNegIndicates the b->a measurement DC voltage. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.78
hwLoopLineTestItgDcUpIndicates the current mapping the A-wire highest voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.79
hwLoopLineTestItgDcDownIndicates the current mapping the A-wire lowest voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.80
hwLoopLineTestIrgDcUpIndicates the current mapping the B-wire highest voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.81
hwLoopLineTestIrgDcDownIndicates the current mapping the B-wire lowest voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.82
hwLoopLineTestItrPosIndicates the current mapping the A->B positive voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.83
hwLoopLineTestItrNegIndicates the current mapping the A->B negative voltage for test. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.84
hwLoopLineTestRingerIndicates the detected ringer.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.85
hwLoopLineTestPPAResIndicates the resistance of PPA. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.86
hwLoopLineTestStartTimeIndicates the start time and date of the MELT test.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.87
hwLoopLineTestEndTimeIndicates the end time and date of the MELT test.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.88
hwLoopLineTestOprMeasuredFreqIndicates the measured frequency for complex impedance. Options: 1. frequency25Hz(0) -25 Hz 2. frequency275Hz(1) -275 Hz 3. invalid(-1) -invalid value Default: frequency25Hz(0)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.89
hwLoopLineTestIfIndexPort IfIndex.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.90
hwLoopLineTestRequestIDRequest ID. The value is the fourth parameter in the trap message.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.91
hwLoopLineTestRABPoleIndicates the A->B polarity resistance. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.92
hwLoopLineTestACAGFlagIndicates whether the value of hwLoopLineTestACAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAG is valid 2. invalid(2) -the value of hwLoopLineTestACAG is invalid 3. notsupport(3) -the value of hwLoopLineTestACAG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.93
hwLoopLineTestACBGFlagIndicates whether the value of hwLoopLineTestACBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACBG is valid 2. invalid(2) -the value of hwLoopLineTestACBG is invalid 3. notsupport(3) -the value of hwLoopLineTestACBG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.94
hwLoopLineTestACABFlagIndicates whether the value of hwLoopLineTestACAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAB is valid 2. invalid(2) -the value of hwLoopLineTestACAB is invalid 3. notsupport(3) -the value of hwLoopLineTestACAB is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.95
hwLoopLineTestDCAGFlagIndicates whether the value of hwLoopLineTestDCAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAG is valid 2. invalid(2) -the value of hwLoopLineTestDCAG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.96
hwLoopLineTestDCBGFlagIndicates whether the value of hwLoopLineTestDCBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCBG is valid 2. invalid(2) -the value of hwLoopLineTestDCBG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCBG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.97
hwLoopLineTestDCABFlagIndicates whether the value of hwLoopLineTestDCAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAB is valid 2. invalid(2) -the value of hwLoopLineTestDCAB is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAB is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.98
hwLoopLineTestRAGFlagIndicates whether the value of hwLoopLineTestRAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAG is valid 2. invalid(2) -the value of hwLoopLineTestRAG is invalid 3. notsupport(3) -the value of hwLoopLineTestRAG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.99
hwLoopLineTestRBGFlagIndicates whether the value of hwLoopLineTestRBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRBG is valid 2. invalid(2) -the value of hwLoopLineTestRBG is invalid 3. notsupport(3) -the value of hwLoopLineTestRBG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.100
hwLoopLineTestRABFlagIndicates whether the value of hwLoopLineTestRAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAB is valid 2. invalid(2) -the value of hwLoopLineTestRAB is invalid 3. notsupport(3) -the value of hwLoopLineTestRAB is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.101
hwLoopLineTestRABPoleFlagIndicates whether the value of hwLoopLineTestRABPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABPole is valid 2. invalid(2) -the value of hwLoopLineTestRABPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABPole is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.102
hwLoopLineTestRABResPoleFlagIndicates whether the value of hwLoopLineTestRABResPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABResPole is valid 2. invalid(2) -the value of hwLoopLineTestRABResPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABResPole is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.103
hwLoopLineTestCapAGFlagIndicates whether the value of hwLoopLineTestCapAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAG is valid 2. invalid(2) -the value of hwLoopLineTestCapAG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.104
hwLoopLineTestCapBGFlagIndicates whether the value of hwLoopLineTestCapBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapBG is valid 2. invalid(2) -the value of hwLoopLineTestCapBG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapBG is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.105
hwLoopLineTestCapABFlagIndicates whether the value of hwLoopLineTestCapAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAB is valid 2. invalid(2) -the value of hwLoopLineTestCapAB is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAB is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.106
hwLoopLineTestRbattipFlagIndicates whether the value of hwLoopLineTestRbattip is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbattip is valid 2. invalid(2) -the value of hwLoopLineTestRbattip is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.107
hwLoopLineTestRbatringFlagIndicates whether the value of hwLoopLineTestRbatring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbatring is valid 2. invalid(2) -the value of hwLoopLineTestRbatring is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.108
hwLoopLineTestRringFlagIndicates whether the value of hwLoopLineTestRring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRring is valid 2. invalid(2) -the value of hwLoopLineTestRring is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.109
hwLoopLineTestCsigFlagIndicates whether the value of hwLoopLineTestCsig is valid. Options: 1. valid(1) -the value of hwLoopLineTestCsig is valid 2. invalid(2) -the value of hwLoopLineTestCsig is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.110
hwLoopLineTestPPAResFlagIndicates whether the value of hwLoopLineTestPPARes is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPARes is valid 2. invalid(2) -the value of hwLoopLineTestPPARes is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.111
hwLoopLineTestVzenerFlagIndicates whether the value of hwLoopLineTestVzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestVzener is valid 2. invalid(2) -the value of hwLoopLineTestVzener is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.112
hwLoopLineTestRzenerFlagIndicates whether the value of hwLoopLineTestRzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestRzener is valid 2. invalid(2) -the value of hwLoopLineTestRzener is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.113
hwLoopLineTestSNMPRabIndicates the A to B resistance (insulation resistance). Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.114
hwLoopLineTestSNMPRabFlagIndicates whether the value of hwLoopLineTestSNMPRab is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRab is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRab is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.115
hwLoopLineTestSNMPRbaIndicates the B to A resistance (insulation resistance). Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.116
hwLoopLineTestSNMPRbaFlagIndicates whether the value of hwLoopLineTestSNMPRba is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRba is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRba is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.117
hwLoopLineTestPPAResultFlagIndicates whether the value of hwLoopLineTestPPA is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPA is valid 2. invalid(2) -the value of hwLoopLineTestPPA is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.118
hwLoopLineTestUtgAcFreqFlagIndicates whether the value of hwLoopLineTestUtgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcFreq is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.119
hwLoopLineTestUrgAcFreqFlagIndicates whether the value of hwLoopLineTestUrgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcFreq is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.120
hwLoopLineTestUtrAcFreqFlagIndicates whether the value of hwLoopLineTestUtrAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcFreq is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.121
hwLoopLineTestItipAcFlagIndicates whether the value of hwLoopLineTestItipAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipAc is valid 2. invalid(2) -the value of hwLoopLineTestItipAc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipAc is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.122
hwLoopLineTestIringAcFlagIndicates whether the value of hwLoopLineTestIringAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringAc is valid 2. invalid(2) -the value of hwLoopLineTestIringAc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringAc is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.123
hwLoopLineTestItipDcFlagIndicates whether the value of hwLoopLineTestItipDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipDc is valid 2. invalid(2) -the value of hwLoopLineTestItipDc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipDc is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.124
hwLoopLineTestIringDcFlagIndicates whether the value of hwLoopLineTestIringDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringDc is valid 2. invalid(2) -the value of hwLoopLineTestIringDc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringDc is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.125
hwLoopLineTestGtgFlagIndicates whether the value of hwLoopLineTestGtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtg is valid 2. invalid(2) -the value of hwLoopLineTestGtg is invalid 3. notsupport(3) -the value of hwLoopLineTestGtg is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.126
hwLoopLineTestBtgFlagIndicates whether the value of hwLoopLineTestBtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtg is valid 2. invalid(2) -the value of hwLoopLineTestBtg is invalid 3. notsupport(3) -the value of hwLoopLineTestBtg is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.127
hwLoopLineTestGrgFlagIndicates whether the value of hwLoopLineTestGrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGrg is valid 2. invalid(2) -the value of hwLoopLineTestGrg is invalid 3. notsupport(3) -the value of hwLoopLineTestGrg is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.128
hwLoopLineTestBrgFlagIndicates whether the value of hwLoopLineTestBrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBrg is valid 2. invalid(2) -the value of hwLoopLineTestBrg is invalid 3. notsupport(3) -the value of hwLoopLineTestBrg is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.129
hwLoopLineTestGtrFlagIndicates whether the value of hwLoopLineTestGtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtr is valid 2. invalid(2) -the value of hwLoopLineTestGtr is invalid 3. notsupport(3) -the value of hwLoopLineTestGtr is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.130
hwLoopLineTestBtrFlagIndicates whether the value of hwLoopLineTestBtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtr is valid 2. invalid(2) -the value of hwLoopLineTestBtr is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.131
hwLoopLineTestSIGNFlagIndicates whether the value of hwLoopLineTestSIGN is valid. Options: 1. valid(1) -the value of hwLoopLineTestSIGN is valid 2. invalid(2) -the value of hwLoopLineTestSIGN is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.132
hwLoopLineTestACFEMFlagIndicates whether the value of hwLoopLineTestACFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestACFEM is valid 2. invalid(2) -the value of hwLoopLineTestACFEM is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.133
hwLoopLineTestDCFEMFlagIndicates whether the value of hwLoopLineTestDCFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCFEM is valid 2. invalid(2) -the value of hwLoopLineTestDCFEM is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.134
hwLoopLineTestONHKFlagIndicates whether the value of hwLoopLineTestONHK is valid. Options: 1. valid(1) -the value of hwLoopLineTestONHK is valid 2. invalid(2) -the value of hwLoopLineTestONHK is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.135
hwLoopLineTestOPENFlagIndicates whether the value of hwLoopLineTestOPEN is valid. Options: 1. valid(1) -the value of hwLoopLineTestOPEN is valid 2. invalid(2) -the value of hwLoopLineTestOPEN is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.136
hwLoopLineTestSHORTFlagIndicates whether the value of hwLoopLineTestSHORT is valid. Options: 1. valid(1) -the value of hwLoopLineTestSHORT is valid 2. invalid(2) -the value of hwLoopLineTestSHORT is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.137
hwLoopLineTestROHFlagIndicates whether the value of hwLoopLineTestROH is valid. Options: 1. valid(1) -the value of hwLoopLineTestROH is valid 2. invalid(2) -the value of hwLoopLineTestROH is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.138
hwLoopLineTestUtgDcUpFlagIndicates whether the value of hwLoopLineTestUtgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcUp is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.139
hwLoopLineTestUtgDcDownFlagIndicates whether the value of hwLoopLineTestUtgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcDown is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.140
hwLoopLineTestUrgDcUpFlagIndicates whether the value of hwLoopLineTestUrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcUp is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.141
hwLoopLineTestUrgDcDownFlagIndicates whether the value of hwLoopLineTestUrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcDown is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.142
hwLoopLineTestUtrPosFlagIndicates whether the value of hwLoopLineTestUtrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrPos is valid 2. invalid(2) -the value of hwLoopLineTestUtrPos is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.143
hwLoopLineTestUtrNegFlagIndicates whether the value of hwLoopLineTestUtrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrNeg is valid 2. invalid(2) -the value of hwLoopLineTestUtrNeg is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.144
hwLoopLineTestItgDcUpFlagIndicates whether the value of hwLoopLineTestItgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestItgDcUp is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.145
hwLoopLineTestItgDcDownFlagIndicates whether the value of hwLoopLineTestItgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestItgDcDown is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.146
hwLoopLineTestIrgDcUpFlagIndicates whether the value of hwLoopLineTestIrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcUp is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.147
hwLoopLineTestIrgDcDownFlagIndicates whether the value of hwLoopLineTestIrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcDown is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.148
hwLoopLineTestItrPosFlagIndicates whether the value of hwLoopLineTestItrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrPos is valid 2. invalid(2) -the value of hwLoopLineTestItrPos is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.149
hwLoopLineTestItrNegFlagIndicates whether the value of hwLoopLineTestItrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrNeg is valid 2. invalid(2) -the value of hwLoopLineTestItrNeg is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.150
hwLoopLineTestRingerFlagIndicates whether the value of hwLoopLineTestRinger is valid. Options: 1. valid(1) -the value of hwLoopLineTestRinger is valid 2. invalid(2) -the value of hwLoopLineTestRinger is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.151
hwLoopLineTestLRFlagIndicates whether the value of hwLoopLineTestLR is valid. Options: 1. valid(1) -the value of hwLoopLineTestLR is valid 2. invalid(2) -the value of hwLoopLineTestLR is invalid 3. notsupport(3) -the value of hwLoopLineTestLR is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.152
hwLoopLineTestDcCurrentIndicates whether DcCurrent exists on the line under test. Options: 1. notest(1) -DcCurrent does not exist on the line under test 2. test(2) -DcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.153
hwLoopLineTestAcCurrentIndicates whether AcCurrent exists on the line under test. Options: 1. notest(1) -AcCurrent does not exist on the line under test 2. test(2) -AcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.154
hwLoopLineTestConductanceIndicates whether conductance exists on the line under test. Options: 1. notest(1) -Conductance does not exist on the line under test 2. test(2) -Conductance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.155
hwLoopLineTestSusceptanceIndicates whether susceptance exists on the line under test. Options: 1. notest(1) -Susceptance does not exist on the line under test 2. test(2) -Susceptance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.156
hwLoopLineTestAcfrequencyAIndicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hzro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.157
hwLoopLineTestAcfrequencyBIndicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hzro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.158
hwLoopLineTestCapABHIndicates the A->B capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.159
hwLoopLineTestCapABHFlagIndicates whether the value of hwLoopLineTestCapABH is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapABH is valid 2. invalid(2) -the value of hwLoopLineTestCapABH is invalid 3. notsupport(3) -the value of hwLoopLineTestCapABH is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.160
hwLoopLineTestGtrHIndicates the A->B conductance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.161
hwLoopLineTestGtrHFlagIndicates whether the value of hwLoopLineTestGtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtrH is valid 2. invalid(2) -the value of hwLoopLineTestGtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestGtrH is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.162
hwLoopLineTestBtrHIndicates the A->B susceptance. Unit: nSro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.163
hwLoopLineTestBtrHFlagIndicates whether the value of hwLoopLineTestBtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtrH is valid 2. invalid(2) -the value of hwLoopLineTestBtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestBtrH is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.164
hwLoopLineTestABDcCurrentIndicates the A->B Dc current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.165
hwLoopLineTestABDcCurrentFlagIndicates whether the value of hwLoopLineTestABDcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABDcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABDcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABDcCurrent is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.166
hwLoopLineTestBADcCurrentIndicates the B->A Dc current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.167
hwLoopLineTestBADcCurrentFlagIndicates whether the value of hwLoopLineTestBADcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBADcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBADcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBADcCurrent is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.168
hwLoopLineTestABAcCurrentIndicates the A->B Ac current. Unit: uArmsro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.169
hwLoopLineTestABAcCurrentFlagIndicates whether the value of hwLoopLineTestABAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABAcCurrent is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.170
hwLoopLineTestBAAcCurrentIndicates the B->A Ac current. Unit: uArmsro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.171
hwLoopLineTestBAAcCurrentFlagIndicates whether the value of hwLoopLineTestBAAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBAAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBAAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBAAcCurrent is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.172
hwLoopLineTestCSfrequencyForTestIndicates the frequency for test capacitance and conductance. Unit: Hzro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.173
hwLoopLineTestCSfrequencyForTestFlagIndicates whether the value of hwLoopLineTestCSfrequencyForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestCSfrequencyForTest is valid 2. invalid(2) -the value of hwLoopLineTestCSfrequencyForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestCSfrequencyForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.174
hwLoopLineTestImpedanceForTestIndicates the resistance inputed in test abnormal voltage. Unit:ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.175
hwLoopLineTestImpedanceForTestFlagIndicates whether the value of hwLoopLineTestImpedanceForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestImpedanceForTest is valid 2. invalid(2) -the value of hwLoopLineTestImpedanceForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestImpedanceForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.176
hwLoopLineTestMaxVForSignatureIndicates the maximum voltage for signature. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.177
hwLoopLineTestMaxVForSignatureFlagIndicates whether the value of hwLoopLineTestMaxVForSignature is valid. Options: 1. valid(1) -the value of hwLoopLineTestMaxVForSignature is valid 2. invalid(2) -the value of hwLoopLineTestMaxVForSignature is invalid 3. notsupport(3) -the value of hwLoopLineTestMaxVForSignature is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.178
hwLoopLineTestAGMaxVForTestIndicates the A->ground max voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.179
hwLoopLineTestAGMaxVForTestFlagIndicates whether the value of hwLoopLineTestAGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.180
hwLoopLineTestAGMinVForTestIndicates the A->ground min voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.181
hwLoopLineTestAGMinVForTestFlagIndicates whether the value of hwLoopLineTestAGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.182
hwLoopLineTestBGMaxVForTestIndicates the B->ground max voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.183
hwLoopLineTestBGMaxVForTestFlagIndicates whether the value of hwLoopLineTestBGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.184
hwLoopLineTestBGMinVForTestIndicates the B->ground min voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.185
hwLoopLineTestBGMinVForTestFlagIndicates whether the value of hwLoopLineTestBGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.186
hwLoopLineTestABMaxVForTestIndicates the A->B max voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.187
hwLoopLineTestABMaxVForTestFlagIndicates whether the value of hwLoopLineTestABMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.188
hwLoopLineTestABMinVForTestIndicates the A->ground min voltage in testing. Unit: mVro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.189
hwLoopLineTestABMinVForTestFlagIndicates whether the value of hwLoopLineTestABMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMinVForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.190
hwLoopLineTestAGMaxCForTestIndicates the A->ground max current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.191
hwLoopLineTestAGMaxCForTestFlagIndicates whether the value of hwLoopLineTestAGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.192
hwLoopLineTestAGMinCForTestIndicates the A->ground min current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.193
hwLoopLineTestAGMinCForTestFlagIndicates whether the value of hwLoopLineTestAGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.194
hwLoopLineTestBGMaxCForTestIndicates the B->ground max current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.195
hwLoopLineTestBGMaxCForTestFlagIndicates whether the value of hwLoopLineTestBGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.196
hwLoopLineTestBGMinCForTestIndicates the B->ground min current. Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.197
hwLoopLineTestBGMinCForTestFlagIndicates whether the value of hwLoopLineTestBGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.198
hwLoopLineTestABMaxCForTestIndicates the A->B max current Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.199
hwLoopLineTestABMaxCForTestFlagIndicates whether the value of hwLoopLineTestABMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.200
hwLoopLineTestABMaxNegCForTestIndicates the A->ground min current Unit: uAro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.201
hwLoopLineTestABMaxNegCForTestFlagIndicates whether the value of hwLoopLineTestABMaxNegCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxNegCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxNegCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxNegCForTest is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.202
hwLoopLineTestLineALengthIndicates length of line A Unit: mro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.203
hwLoopLineTestLineBLengthIndicates length of line B Unit: mro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.204
hwLoopLineTestTermimalConcusionIndicates Termimal Concusion Options: 1. noPhone(1) -the TermimalConcusion is not connect Phone 2. offHook(2) -the TermimalConcusion is connect phone and offhook 3. eTSIxDSLsignature(3) -the TermimalConcusion is ETSI XDSL Signature 4. abMixed(4) -the TermimalConcusion is ab line short 5. rcNetWork(5) -the TermimalConcusion is rcNetWork 6. elecRing(6) -the TermimalConcusion is elecRing 7. other(7) -the TermimalConcusion is other unknown terminal 8. abMixInMDF(8) -the TermimalConcusion is abMixInMDF 9. abMixOutMDF(9) -the TermimalConcusion is abMixOutMDF 10. invalid(-1) -the TermimalConcusion is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.205
hwLoopLineTestMoreDataFlagIndicates is there more data Options: 1. more(1) -Indicates there is more data needs report,but needs a SNMP-GET oper. to get other data. 2. invalid(-1) -Indicates the value is invalidro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.206
hwLoopLineTestCtrLVAggregate tip-ring capacitance: CtrLV = Cco + Ctr + Cring, measured by means of low voltage ramps, such that it does NOT include the capacitance Csig whenever the ETSI Signature terminates the subscriber loop. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.207
hwLoopLineTestCtrLVFlagIndicates whether the value of hwLoopLineTestCtrLV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrLV is valid 2. invalid(2) -the value of hwLoopLineTestCtrLV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrLV is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.208
hwLoopLineTestCtrHVAggregate tip-ring capacitance: CtrHV = Cco + Ctr + Cring + Csig, measured by means of high voltage ramps. It includes the capacitance Csig of an ETSI Signature whenever connected to the tip and ring wires. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.209
hwLoopLineTestCtrHVFlagIndicates whether the value of hwLoopLineTestCtrHV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrHV is valid 2. invalid(2) -the value of hwLoopLineTestCtrHV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrHV is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.210
hwLoopLineTestCtrAcAggregate tip-ring capacitance: CtrAc = Cco + Ctr + Cring, measured by means of a low amplitude AC signal (either 25 Hz or 275 Hz). It does NOT include Csig. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.211
hwLoopLineTestCtrAcFlagIndicates whether the value of hwLoopLineTestCtrAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrAc is valid 2. invalid(2) -the value of hwLoopLineTestCtrAc is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrAc is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.212
hwLoopLineTestRtgSerResistance in series with Ctg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.213
hwLoopLineTestRtgSerFlagIndicates whether the value of hwLoopLineTestRtgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtgSer is valid 2. invalid(2) -the value of hwLoopLineTestRtgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtgSer is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.214
hwLoopLineTestRrgSerResistance in series with Crg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.215
hwLoopLineTestRrgSerFlagIndicates whether the value of hwLoopLineTestRrgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRrgSer is valid 2. invalid(2) -the value of hwLoopLineTestRrgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRrgSer is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.216
hwLoopLineTestRtrSerResistance in series with Ctring, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohmro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.217
hwLoopLineTestRtrSerFlagIndicates whether the value of hwLoopLineTestRtrSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtrSer is valid 2. invalid(2) -the value of hwLoopLineTestRtrSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtrSer is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.218
hwLoopLineTestUtgAcAdmitAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tipground admittance Ytg = Gtg + i * Btg. Unit: Vro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.219
hwLoopLineTestUtgAcAdmitFlagIndicates whether the value of hwLoopLineTestUtgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcAdmit is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.220
hwLoopLineTestUrgAcAdmitAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the ringground admittance Yrg = Grg + i * Brg. Unit: Vro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.221
hwLoopLineTestUrgAcAdmitFlagIndicates whether the value of hwLoopLineTestUrgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcAdmit is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.222
hwLoopLineTestUtrAcAdmitAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tip-ring admittance Ytr = Gtr + i * Btr. Unit: Vro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.223
hwLoopLineTestUtrAcAdmitFlagIndicates whether the value of hwLoopLineTestUtrAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcAdmit is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.224
hwLoopLineTestCapterminalA capacitive termination of the access line shall be identified by the capacitance measurement and the associated evaluation. The following average value for the capacitance Cabk of the measured cable can be assumed: Cabk = 0.083(Cae + Cbe). If the measured capacitance is Cab > Cabk + 50 nF for ADSL&VDSL, or Cab > Cabk + 100 nF for SHDSL, respectively, It can be assumed that a terminal device with a significant self-capacitance is connected to the line. The cable-factor 0.083 is determined by hwLoopLineTestSysConfigCableFactor. Options: 1. noexist(1) -Significant terminal device capacitance is not detected 2. exist(2) -Significant terminal device capacitance is detectedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.225
hwLoopLineTestCapterminalFlagIndicates whether the value of hwLoopLineTestCapterminal is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapterminal is valid 2. invalid(2) -the value of hwLoopLineTestCapterminal is invalid 3. notsupport(3) -the value of hwLoopLineTestCapterminal is not supportro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.226
hwMeterTestOprTableOperation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this table is ifIndex.
SEQUENCE OF HwMeterTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.3
hwMeterTestOprEntryOperation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this entry is ifIndex.
HwMeterTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1
hwMeterTestOprTypeOperation type. Options: 1. stop(1) -operation type is stop 2. start(2) -operation type is startrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.1
hwMeterTestItemTest items. Options: 1. inline(1) -in test 2. outline(2) -out testrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.2
hwMeterTestStatusTest status. Options: 1. success(1) -no test on busy 2. fail(2) -remedy test on busy 3. portbusy(3) -forced test on busy 4. outoftime(4) -test out of time 5. testingAbnormal(5) -test abnormal 6. broadbandtesting(6) -broadband testing 7. capturefail(7) -capture fail 8. notratb(8) -relay transfer board not existro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.3
hwMeterTestBusyFlagMeter test busy flag. Options: 1. busyNoTest(1) -no test on busy 2. busyTest(2) -test on busy 3. busystrenTest(3) -forced test on busyrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.4
hwTestBoardDiagnoseTestOprTableOperation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this table is ifIndex.
SEQUENCE OF HwTestBoardDiagnoseTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.4
hwTestBoardDiagnoseTestOprEntryOperation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this entry is ifIndex.
HwTestBoardDiagnoseTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1
hwTestBoardDiagnoseTestOprTypeOperation type. Options: 1. start(2) -operation type is startrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.1
hwTestBoardDiagnoseTestResultSelf-diagnosis result. Options: 1. selfTestOver(1) -self-diagnosis successful 2. selfTestFail(2) -self-diagnosis failure 3. testingAbnormal(3) -test abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.2
hwTestBoardDiagnoseTestRAMSystem RAMRAM. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.3
hwTestBoardDiagnoseTestVoltageVoltage. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.4
hwTestBoardDiagnoseTestResistanceResistance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.5
hwTestBoardDiagnoseTestSignalSignal circuit. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.6
hwTestBoardDiagnoseTestDTMFDTMF. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.7
hwTestBoardDiagnoseTestRingRinging. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.8
hwTestBoardDiagnoseTestOnOffHookOn/off hook. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.9
hwTestBoardDiagnoseTestPolePolarity reversal. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.10
hwTestBoardDiagnoseTestISDNUISDN U port. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.11
hwTestBoardDiagnoseTestBitErrCodeError code test. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.12
hwTestBoardDiagnoseTestCapacitanceCapacitance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.13
hwTestBoardStatusQueryOprTableOperation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this table is ifIndex.
SEQUENCE OF HwTestBoardStatusQueryOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.5
hwTestBoardStatusQueryOprEntryOperation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this entry is ifIndex.
HwTestBoardStatusQueryOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1
hwTestBoardStatusQueryOprTypeOperation type. Options: 1. beginQuery(2) -startrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.1
hwTestBoardStatusQueryResultQuery status. Options: 1. querySuccess(1) -query status successful 2. queryFail(2) -query status failurero
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.2
hwTestBoardStatusQueryVersionVersion.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.3
hwTestBoardStatusQueryTestItemTest item. Options: 1. testIdle(1) -idle 2. pstnUserInLineTest(2) -pstn inline test 3. userLineTest(3) -loop line test 4. phoneTest(4) -telephone test 5. manTestOutLine(5) -manual test outline 6. manTestInnerLine(6) -manual test inline 7. halfAutoUserCircuit(7) -half auto tss user circuit -meter interface 8. halfAutoTssPhoneCircuit(8) -half auto tss telephone circuit -meter interface 9. tssSelfTest(9) -Tss self test 10. testInnerBus(10) -test inline bus test 11. testOuterBus(11) -test outline bus test 12. digUserOutLineTest(12) -isdn outline test 13. digUserInnerLineTest(13) -isdn inline test 14. switchToStandIsdnTerminal(14) -switch to standard isdn terminal 15. switchToIsdnSpecialcode(15) -switch to isdn special service telephone number 16. testBoarDfault(16) -test board fault 17. pstnRemoteCallTest(17) -pstn user remote call test 18. indialtest(18) -in-dial test 19. coEmulate(33) -CO simulation test 20. cqtTest(34) -CQT test 21. cqtFRTest(35) -CQT Frequency Response Measurement 22. cqtTDRTest(36) -CQT Time Domain Reflectometry Measurement 23. cqtDMTTest(37) -CQT Data Rate Prediction Measurement 24. cqtNSETest(38) -CQT Noise Measurement 25. cqtLBTest(39) -CQT Longitudinal Balance Measurement 26. cqtLCTest(40) -CQT Load Coil Detection 27. internalcaptureTestedPort(61) -Capture tested port loopline 28. externalcaptureTestedPort(62) -Capture tested port inline 29. monitorTest(63) -monitor test 30. seltTest(64) -selt test 31. sendtoneTest(65) -tone send test 32. checktoneTest(66) -tone check test 33. autocalltest(67) -auto call test 34. anothermainboardistesting(241) -another main board is testingro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.4
hwTestBoardStatusTestedBoardIfIndexIndex of the tested port.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.5
hwSearchingToneOprTableThis table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this table is ifindex.
SEQUENCE OF HwSearchingToneOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.6
hwSearchingToneOprEntryThis table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this entry is ifindex.
HwSearchingToneOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1
hwSearchingToneOprTypeSearching tone test-operation type. Options: 1. stop(1) -stop a searching tone test 2. start(2) -start a searching tone test 3. invalid(-1) -invalid valuerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.1
hwSearchingToneLevelIndicates the test voltage level of a searching tone test. Options: 1. -1 -Invalid value 2. 80..500 -(XDSL Range: 80-126 MXU voice Range: 80-500) Default: 120 -(XDSL Default: 120 MXU voice default:295) Unit: mVrw
Integer32 (-1 | 80..500)
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.2
hwSearchingToneFrequencyIndicates the test frequency of a searching tone test. Default: 800 Unit: Hzrw
Integer32 (-1 | 300..3400)
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.3
hwSearchingToneDurationTimeIndicates the test duration of a searching tone test. Default: 9000 Unit: 0.1srw
Integer32 (-1 | 1..54000)
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.4
hwSearchingToneRemainingTimeIndicates the test remaining time of a searching tone test. Unit: 0.1sro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.5
hwSearchingToneBusyProcFlagSearching tone test-busy flag. Options: 1. cancel(1) -when port is busy do not start a searching tone test 2. force(2) -when port is busy force to start a searching tone test 3. invalid(-1) -invalid valuerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.6
hwLoopLineTestCalibrationTableThis table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this table is ifindex.
SEQUENCE OF HwLoopLineTestCalibrationEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.7
hwLoopLineTestCalibrationEntryThis table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this entry is ifindex.
HwLoopLineTestCalibrationEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1
hwLoopLineTestAGCalibrationIndicates the test calibration data of A->Ground capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1
hwLoopLineTestBGCalibrationIndicates the test calibration data of B->Ground capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2
hwLoopLineTestABCalibrationIndicates the test calibration data of A->B capacitance. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3
hwLoopLineTestMeltVerTableThis table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this table are hwFrameIndex and hwSlotIndex.
SEQUENCE OF HwLoopLineTestMeltVerEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.8
hwLoopLineTestMeltVerEntryThis table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this entry are hwFrameIndex and hwSlotIndex.
HwLoopLineTestMeltVerEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1
hwLoopLineTestMeltFactoryMELT chipset manufacturer information Maximum length: 32 Octetsro
OCTET STRING
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.1
hwLoopLineTestMeltChipMELT chipset manufacturer hardware information Maximum length: 128 Octetsro
OCTET STRING
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.2
hwLoopLineTestMeltFirmwareVerMELT chipset manufacturer version information Maximum length: 16 Octetsro
OCTET STRING
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.3
hwLoopLineTestSysConfigPara
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.1.1.9
hwLoopLineTestSysConfigConvertABIndicates the polarity of A wire and B wire. Options: 1. normal(1) -default polarity of A wire and B wire 2. reverse(2) -reverse polarity of A wire and B wire 3. invalid(-1) -invalid value Default: normal(1)rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.9.1
hwLoopLineTestSysConfigCableFactorThe cable-factor used to detect significant terminal device capacitance. The cable-factor ranges from 1 to 1000 units of 0.001 (Physical values are 0.001 to 1, default: 0.083).rw
Unsigned32
.1.3.6.1.4.1.2011.6.21.1.1.1.9.2
hwLoopLineTestSysConfigSigCapUpperLimitThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 1350nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.rw
Unsigned32
.1.3.6.1.4.1.2011.6.21.1.1.1.9.3
hwLoopLineTestSysConfigSigCapLowerLimitThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 250nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.rw
Unsigned32
.1.3.6.1.4.1.2011.6.21.1.1.1.9.4
hwLoopLineTestSysConfigSigResistanceThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The resistance ranges from 10000ohm to 1000000ohm, default: 55000ohm.rw
Unsigned32
.1.3.6.1.4.1.2011.6.21.1.1.1.9.5
hwONTPotsTestOprTableThis table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this table are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
SEQUENCE OF HwONTPotsTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.10
hwONTPotsTestOprEntryThis table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this entry are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
HwONTPotsTestOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1
hwONTPotsTestONTIndexONT ID.
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1
hwONTPotsTestONTPstnPortIndexONT port ID.
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2
hwONTPotsTestOprTypePOTS port line Test-operation type. Options: 1. stop(1) -stop a POTS port line test 2. start(2) -start a POTS port line test 3. invalid(-1) -invalid valuerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3
hwONTPotsTestItemPOTS port line test item. Options: 1. allMLTTests(1) -outdoor connection test 2. hazardousPotential(2) -hazardous potential test 3. foreignEMF(3) -foreign electromotive force(EMF) test 4. resistiveFaults(4) -resistive faults test 5. receiverOff-hook(5) -receiver off-hook test 6. ringer(6) -ringer impedance test 7. nT1DcSignatureTest(7) -NT1 dc signature test 8. selfTest(8) -self test 9. dialToneMake-breakTest(9) -dial tone make-break test 10. subscriber-line(10) -subscriber line test 11. vendor-specificTest2(11) -vendor-specific test all results are returned in a test result message 12. vendor-specificTest3(12) -vendor-specific test all results are returned in a test result message 13. vendor-specificTest4(13) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 14. vendor-specificTest5(14) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 15. vendor-specificTest6(15) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 16. vendor-specificTest7(16) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP bufferrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4
hwONTPotsTestBusyProcFlagTest mode when a line is busy. Options: 1. cancel(1) -deny a test if a line is busy 2. force(2) -forced moderw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5
hwONTPotsTestT1ThresholdSlow dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..6000 -Valid value rangerw
Integer32(0 | 100..6000)
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6
hwONTPotsTestT2ThresholdNo dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..10000 -Valid value rangerw
Integer32(0 | 1000..10000)
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7
hwONTPotsTestT3ThresholdSlow break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..3000 -Valid value rangerw
Integer32(0 | 100..3000)
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8
hwONTPotsTestT4ThresholdNo break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..3000 -Valid value rangerw
Integer32(0 | 1000..3000)
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9
hwONTPotsTestDtmfDigitDTMF test number. Options: 1. zero(1) -the test number is 0 2. one(2) -the test number is 1 3. two(3) -the test number is 2 4. three(4) -the test number is 3 5. four(5) -the test number is 4 6. five(6) -the test number is 5 7. six(7) -the test number is 6 8. seven(8) -the test number is 7 9. eight(9) -the test number is 8 10. nine(10) -the test number is 9 11. symbolStar(11) -the test number is * 12. symbolSharp(12)-the test number is # 13. default(13) -use the default value (number) of the systemrw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10
hwONTPotsTestDialTypeThe dialling type of dialling tone test. Options: 1. dtmf(1) -dtmf type 2. pulse(2) -pulse typerw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11
hwONTPotsTestDialToneFreq1The frequency1 in the dialling tone test. 0 -unused Unit: Hzrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12
hwONTPotsTestDialToneFreq2The frequency2 in the dialling tone test. 0 -unused Unit: Hzrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13
hwONTPotsTestDialToneFreq3The frequency3 in the dialling tone test. 0 -unused Unit: Hzrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14
hwONTPotsTestDialToneEnergyThresholdThe value of energy threshold in the dialling tone test. Valid value: 1. 0x00: unspecified 2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0 Unit: 0.1 dBm0rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15
hwONTPotsTestIdleChannelEnergyThresholdThe value of energy threshold in the dialling tone test when the line is in the idle state. Valid value: 1. 0x00: unspecified 2. 0x01-0x5A: -1 dBm0 to -90 dBm0 Unit: 1 dBm0rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16
hwONTPotsTestDCHazardousVoltThresholdThe value of DC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: voltrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17
hwONTPotsTestACHazardousVoltThresholdThe value of AC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt.rw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18
hwONTPotsTestDCForeignVoltThresholdThe value of DC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: voltrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19
hwONTPotsTestACForeignVoltThresholdThe value of AC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: voltrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20
hwONTPotsTestAGBGResistanceThresholdThe resistance (tip to ground, ring to ground) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohmrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21
hwONTPotsTestABResistanceThresholdThe resistance (tip to ring) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohmrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22
hwONTPotsTestRingerEquivMinThresholdRinger equivalence minimum threshold. 0x00 -unspecified Unit: 0.01 RENrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23
hwONTPotsTestRingerEquivMaxThresholdRinger equivalence maximum threshold. 0x00 -unspecified Unit: 0.01 RENrw
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24
hwONTPotsTestMLTResultMLT qualitative test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25
hwONTPotsTestHazardousVoltResultHazardous volt test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26
hwONTPotsTestEMFResultEMF test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27
hwONTPotsTestResistacneResultResistacne test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28
hwONTPotsTestOffHookResultThe off-hook test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29
hwONTPotsTestRingerResultRinger test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30
hwONTPotsTestNT1DCSignalResultNT1 DC Signal test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31
hwONTPotsTestSelfTestResultSelf test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run 3. notCompleted(3) -a test is not complete yetro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32
hwONTPotsTestDrawDialToneResultDraw dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passesro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33
hwONTPotsTestBreakDialToneResultThe break dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passesro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34
hwONTPotsTestQuietEnergyResultThe quiet energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35
hwONTPotsTestDialToneEnergyResultThe dialling tone energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails. the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36
hwONTPotsTestLoopDCAGVoltResultThe DC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37
hwONTPotsTestLoopDCBGVoltResultThe DC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run. 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38
hwONTPotsTestLoopACAGVoltResultThe AC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39
hwONTPotsTestLoopACBGVoltResultThe AC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40
hwONTPotsTestLoopResistanceAGResultThe A-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41
hwONTPotsTestLoopResistanceBGResultThe B-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42
hwONTPotsTestLoopResistanceABResultThe A-B (tip to ring) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43
hwONTPotsTestLoopRingerLoadTestResultThe ringer load Loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reportedro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44
hwONTPotsTestDrawDialToneTimeValueThe draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100ms.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45
hwONTPotsTestBreakDialToneTimeValueThe break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100 ms.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46
hwONTPotsTestQuietEnergyValueThe quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-90 : 0 dBm0 to -90 dBm0 Step: 1 dBm0ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47
hwONTPotsTestDialToneEnergyValueThe dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-255 : 0 dBm0 to -25.5 dBm0 Values above 0 dBm0 are reported as 0. Step: 0.1 dBm0ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48
hwONTPotsTestLoopDCAGVoltValueThe DC A-G(Tip-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49
hwONTPotsTestLoopDCBGVoltValueThe DC B-G(Ring-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50
hwONTPotsTestLoopACAGVoltValueThe AC A-G(Tip-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51
hwONTPotsTestLoopACBGVoltValueThe AC B-G(Ring-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52
hwONTPotsTestLoopResistanceAGValueThe A-G (tip to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53
hwONTPotsTestLoopResistanceBGValueThe B-G (ring to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54
hwONTPotsTestLoopResistanceABValueThe A-B (tip to ring) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55
hwONTPotsTestLoopRingerLoadTestValueThe ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult is failMeasurementReported(4) or passMeasurementReported(8). Unit: 0.1 REN.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56
hwONTPotsTestSubscriberLineTestResultThe subscriber line test result. Options: 1. normal(1) -subscriber line test normal 2. acCurrentAbnormal(12) -AC current abnormal 3. dcCurrentAbnormal(13) -DC current abnormal 4. loopCurrentAbnormal(14) -loop current abnormal 5. loopResistanceAbnormal(15) -loop resistance abnormal 6. insulatingResistanceAbnormal(16) -insulating resistance abnormal 7. capacitanceAbnormal(17) -capacitance abnormal 8. impedanceAbnormal(18) -impedance abnormal 9. insulatingNotGood(22) -insulating not good 10. brokenLines(23) -broken lines 11. lineMixing(24) -line mixing 12. connectedToGround(25) -connected to ground 13. abLinereversal(26) -ABLine reversal 14. lineLeaking(27) -line leaking 15. phoneDisconnect(28) -phone disconnect 16. testTimeout(29) -test is time out 17. testFailed(30) -test failed 18. invalid(-1) -a test does not runro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57
hwONTPotsTestLoopDCABVoltValueThe DC A-B (tip-Ring) volt result of subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58
hwONTPotsTestLoopACABVoltValueThe AC A-B (Tip-Ring) volt result of subscriber line test. Unit: volt.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59
hwONTPotsTestLoopAGCapacitanceValueThe A->G (Tip-Ground) capacitance result of subscriber line test. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60
hwONTPotsTestLoopBGCapacitanceValueThe B->G (Ring-Ground) capacitance result of subscriber line test. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61
hwONTPotsTestLoopABCapacitanceValueThe A->B (Tip-Ring) capacitance result of subscriber line test. Unit: nFro
Integer32
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62
hwPortTestingListOprTableThis table is used to query the ports under a test by board. The indexes of this table are hwFrameIndex and hwSlotIndex.
SEQUENCE OF HwPortTestingListOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.11
hwPortTestingListOprEntryThis table is used to query the ports under a test by board. The indexes of this entry are hwFrameIndex and hwSlotIndex.
HwPortTestingListOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.11.1
hwMeltTestingPortListList of ports under a MELT test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a MELT test. For example, if port 8 is under a MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0.ro
Bits
.1.3.6.1.4.1.2011.6.21.1.1.1.11.1.1
hwSearchToneTestingPortListList of ports under a searching tone test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a searching tone test. For example, if port 8 is under MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0.ro
Bits
.1.3.6.1.4.1.2011.6.21.1.1.1.11.1.2
hwWettingCurrentOprTableThis table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this table is ifindex.
SEQUENCE OF HwWettingCurrentOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.12
hwWettingCurrentOprEntryThis table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this entry is ifindex.
HwWettingCurrentOprEntry
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1
hwWettingCurrentOprStatusWetting Current operation type. Options: 1. enabled(1) -enable a wetting current port 2. disabled(2) -disable a wetting current port 3. invalid(-1) -invalid value enabled(1) and disabled(2) options are available in the set operation. enabled(1), disabled(2) and invalid(-1) options are available in the get operation.rw
Enumeration
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.1
hwWettingCurrentOprWorkingVoltageIndicates the working voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 90 Unit: voltrw
Integer32 (-1 | 1..120)
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.2
hwWettingCurrentOprMaximumVoltageIndicates the maximum voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 30 Unit: voltrw
Integer32 (-1 | 1..120)
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.3
hwWettingCurrentOprSlopeIndicates the slope of a wetting current port. Options: 1. -1 -Invalid value 2. 200..20000 -Valid value range Default: 200 Unit: volt per secondrw
Integer32 (-1 | 200..20000)
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.4
hwTestCommonTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2
hwTestCommonTrapVbOids
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.1
hwTestCommonVbOidsReason
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.1.2
hwTestClearedReasonDefinition of the test-canceling reasons. Options: 1. testBoardFail(1) -the test-canceling reason is testBoardFail 2. testedBoardFail(2) -the test-canceling reason is testedBoardFail 3. userCmd(3) -the test-canceling reason is userCmd 4. switchOver(4) -the test-canceling reason is switchOver 5. anotherMainBoardIsTesting(5) -the test-canceling reason is anotherMainBoardIsTesting 6. unknowError(255) -the test-canceling reason is unknowErrorro
Enumeration
.1.3.6.1.4.1.2011.6.21.1.2.1.2.1
hwTestRingSrcAlarmReasonDefinition of the ringing source alarms. Options: 1. testRingSrcFail(1) -the ringing source alarm is testRingSrcFail 2. testRingSrcRestore(2) -the ringing source alarm is testRingSrcRestorero
Enumeration
.1.3.6.1.4.1.2011.6.21.1.2.1.2.2
hwTestCommonRequestIDNMS request ID.ro
Integer32
.1.3.6.1.4.1.2011.6.21.1.2.1.3
hwTestCommonAlarmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.2
hwTestCommonAlarmTrapsOIDs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.2.0
hwTestRingSrcFailTrapThe btss ring source failed trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS doesn't work) Troubleshooting suggestions: (1) Check the BTSS board; (2) Reset the BTSS board; (3) Replace the BTSS board. This trap will send when the btss ring source failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.2.0.1
hwTestRingSrcRestoreTrapTest ringing source restore trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS is normal) The advice: none. This trap will send when test ringing source restore.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.2.0.2
hwTestAutoClearedTrapTrap of test automatically cancelled: 1: hwTestBoardIfIndex; 2: hwTestBoardStatusTestedBoardIfIndex; 3: hwTestClearedReason. This trap will send when the test automatically cancelled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.2.0.3
hwTestCommonGeneralTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.3
hwTestCommonGeneralTrapsOIDs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.21.1.2.3.0
hwLoopLineTestTrapThis trap will be sent when a loop-line test finished successfully. The trap shows the result of the loop-line test. 1. hwLoopLineTestRequestID, 2. hwLoopLineTestStatus, 3. hwLoopLineTestConclusion, 4. hwLoopLineTestACAG, 5. hwLoopLineTestACBG, 6. hwLoopLineTestACAB, 7. hwLoopLineTestDCAG, 8. hwLoopLineTestDCBG, 9. hwLoopLineTestDCAB, 10. hwLoopLineTestRAG, 11. hwLoopLineTestRBG, 12. hwLoopLineTestRAB, 13. hwLoopLineTestCapAG, 14. hwLoopLineTestCapBG, 15. hwLoopLineTestCapAB, 16. hwLoopLineTestLR, 17. hwLoopLineTestRABResPole, 18. hwLoopLineTestMSocket, 19. hwLoopLineTestPPAResult, 19. hwLoopLineTestIfIndex, 20. hwLoopLineTestMoreDataFlag
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.1
hwMeterTestTrapMeter test result trap: 1: hwMeterTestStatus. This trap will send when meter test result return.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.2
hwTestBoardDiagnoseTestTrapTest board self-test result trap: 1: hwTestBoardDiagnoseTestResult; 2: hwTestBoardDiagnoseTestRAM; 3: hwTestBoardDiagnoseTestVoltage; 4: hwTestBoardDiagnoseTestResistance; 5: hwTestBoardDiagnoseTestSignal; 6: hwTestBoardDiagnoseTestDTMF; 7: hwTestBoardDiagnoseTestRing; 8: hwTestBoardDiagnoseTestOnOffHook; 9: hwTestBoardDiagnoseTestPole; 10: hwTestBoardDiagnoseTestISDNU; 11: hwTestBoardDiagnoseTestBitErrCode; 12: hwTestBoardDiagnoseTestCapacitance. This trap will send when the test board self-test result return.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.3
hwTestBoardStatusQueryTrapTest board status query result trap: 1: hwTestBoardStatusQueryResult; 2: hwTestBoardStatusQueryVersion; 3: hwTestBoardStatusQueryTestItem; 4: hwTestBoardStatusTestedBoardIfIndex. This trap will send when the test board status query result return.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.4
hwTestOntPotsTestResultTrapThis trap indicates that a POTS port line test finished successfully, and shows the result of the line test. This trap will send when a POTS port line test finished successfully.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.5
hwTestCommonMeltTestResultTrapThis trap indicates that MELT test finished successfully, and show the result of the melt test This trap will send when the MELT test finished successfully.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.6
hwTestCommonMeltTestFaileTrapThis trap indicates that MELT test fails. This trap will send when the MELT test failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.21.1.2.3.0.7
HUAWEI-COMMTEST-MIB - SNMP MIB Reference | MIBs Explorer