HUAWEI-CLK-MIB
The HUAWEI-CLK-MIB module enables monitoring and management of clock synchronization states on Huawei network equipment, specifically exposing the system work mode and the operational status of third-party clock sub-boards via the `hwUASystemWorkMode` and `hw3rdClkSubBoardWorkMode` objects.
Imported Objects
Objects
16 total| Object Name |
|---|
hwClockClock Management MIB .
Added the Nodes of hwUASystemWorkMode And hw3rdClkSubBoardWorkMode by fengjinchun MODULE-IDENTITY .1.3.6.1.4.1.2011.6.25 |
hwClkMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.6.25.1 |
hwClockInManageTableClock Source Management Table (the max record number is 10) SEQUENCE OF HwClockInManageEntry .1.3.6.1.4.1.2011.6.25.1.1 |
hwClockInManageEntryClock Source Management Table Entity HwClockInManageEntry .1.3.6.1.4.1.2011.6.25.1.1.1 |
hwClkInIndexClock source index: from 0 to 9 is effective, 255 indicates local source INTEGER (0..9 | 255) .1.3.6.1.4.1.2011.6.25.1.1.1.1 |
hwClkInPostionThe ifIndex of physical position of clock source.If the clock source isn't
a sysline clock, the value will be NULL_ULONG(0xFFFFFFFFFFFFFF).The highest
byte is useless.The second byte describes the NO. of frame, the third byte
describes the NO. of slot and the lowest byte describes the port ID.
The following shows how to use parameter when getting or setting:
0x 0000, FFFF,0000,0000 Frame ID; 0~255
0x 0000, 0000,FFFF,0000 Slot ID; 0~255
0x 0000, 0000,0000,FFFF Port ID; 0~255rw Integer32 .1.3.6.1.4.1.2011.6.25.1.1.1.2 |
hwClkInWorkModeClock source type:
none(1),
sysLine(2),
cesLine(3),
cesSrts(4),
e1Bits0(5),
e1Bits1(6),
f2mhzBits0(7),
f2mhzBits1(8),
msuSdh(9),
msuTdm(10),
localSurge(11),
xpm-8k(12),
includes line clock source, bits clock source,local surge source,
If it is line clock source of ces port, it may be ces line or ces srts clock source,.
If it is bits clock source, it may be 2MHZ or e1 clock source of bits0, or 2MHZ or e1.
clock source of bits1. if the value is 1, it indicates that clock source isn't configuredrw Enumeration .1.3.6.1.4.1.2011.6.25.1.1.1.3 |
hwClockOutPortManageTableClock Out Port Management Table(the max record number is 24) SEQUENCE OF HwClockOutPortManageEntry .1.3.6.1.4.1.2011.6.25.1.4 |
hwClockOutPortManageEntryClock Out Port Management Table Entity HwClockOutPortManageEntry .1.3.6.1.4.1.2011.6.25.1.4.1 |
hwClkOutputPostionThe ifIndex of physical position of clock source.The highest
byte is useless.The second byte describes the NO. of frame, the third byte
describes the NO. of slot and the lowest byte describes the NO. of port.
How to use parameter when getting or setting is as below:
0x 0000, FFFF,0000,0000 Frame ID; 0~255
0x 0000, 0000,FFFF,0000 Slot ID; 0~255
0x 0000, 0000,0000,FFFF Port ID; 0~255rw Integer32 .1.3.6.1.4.1.2011.6.25.1.4.1.1 |
hwClkOutPortEnableClock source type:
enable(0),
disable(1),rw Enumeration .1.3.6.1.4.1.2011.6.25.1.4.1.2 |
hwClkInOperStatusclock source state
none(1),
normal(2),
failure(3)
::= { hwClockInManageEntry 4 }
hwClkInRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTIONro Enumeration .hwSystemClockManagePara.1 |
hw3rdClkSubBoardWorkModeThe Out work mode of 3rd subboard clock:
trace(1) indicates clock is working in tracing mode
keep(2) indicates clock is working in keeping mode
3rdsurge(3) indicates clock is working in 3rd subboard crystal
snap(4) indicates clock is working in snap mode
no3rdclksubboard(255) indicates does not have 3rd subboardro Enumeration .hwSystemClockManagePara.2 |
hwSystemClockModeThe Clock mode:
clock-clksubboard(1) clock-subboard supply output clock
clock-localboard(2) local-board supplay output clockro Enumeration .hwSystemClockManagePara.3 |
hw3rdClkSubBoardInputStatusThe Clock mode:
none(1) clock-subboard have no clock-signal input
normal(2) clock-subboard clock-signal input normal
fault(3) clock-subboard clock-signal input fault
no3rdclksubboard(255) indicates does not have 3rd subboardro Enumeration .hwSystemClockManagePara.4 |
hw3rdClkSubBoardOutputStatusThe Clock mode:
normal(1) clock-subboard output status normal
fault(2) clock-subboard output status fault
no3rdclksubboard(255) indicates does not have 3rd subboardro Enumeration .hwSystemClockManagePara.5 |
More MIBs from Huawei
Browse all HuaweiMIBs →The HUAWEI-MIB module provides a unified namespace for monitoring and managing generic system resources, interface statistics, and hardware telemetry across Huawei network devices. It serves as the foundational OID repository for retrieving standard operational data, including CPU utilization, memory usage, interface counters, and device status, required for comprehensive network management via SNMP.
Standard SNMP MIB module defining data structures for HUAWEI-SERVER-IBMC-MIB.
The HUAWEI-XPON-MIB module enables Network Management Systems to monitor and configure GPON and EPON optical line terminals and optical network units, specifically tracking PON port status, optical power levels, bandwidth allocation, and subscriber session states.
SNMP MIB module
The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.
The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.