HP-SWITCH-BASIC-CONFIG-MIB
AI MIB Summary
The HP-SWITCH-BASIC-CONFIG-MIB enables SNMP-based retrieval and configuration of fundamental operational parameters for HP networking switches, including interface status, port speed, duplex settings, and VLAN assignments. This module facilitates the centralized management of Layer 2 switching infrastructure by exposing static configuration objects required for device provisioning and baseline health verification.
This MIB module describes objects for basic switch configuration.
Main OID:
hpSwitchBasicConfigMIB.1.3.6.1.4.1.25506.11.1.7.1.29
74
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
74 total| Object Name |
|---|
hpicfBridgeFilterConfigTableA table that contains information about the
source port traffic filter configuration in this
device. SEQUENCE OF HpicfBridgeFilterConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.8.2 |
hpicfBridgeFilterConfigEntryInformation about a source port traffic filter
configuration in this device. HpicfBridgeFilterConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.8.2.1 |
hpicfBridgeFilterNameThis variable specifies the name of the
filter. Filter name can be upto 20 characters.
Filter name cannot contain tilde (~).
A filter name can not be same as port-name. DisplayString .1.3.6.1.4.1.25506.11.1.7.1.8.2.1.1 |
hpicfBridgeFilterDropPortMaskThis variable specifies a group of ports to which
forwarding of filtered traffic is not permitted.rw PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.25506.11.1.7.1.8.2.1.2 |
hpicfBridgeFilterEntryStatusRow can be deleted only when no port are mapped to
this filter in 'hpSwitchFilterConfigEntry' table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.8.2.1.3 |
hpSwitchIgmpProxyDomainConfigTableA table that contains information about the IGMP
proxy domain configurations on this switch. SEQUENCE OF HpSwitchIgmpProxyDomainConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.15.5 |
hpSwitchIgmpProxyDomainConfigEntryThe information associated with each IGMP
proxy domain configuration. HpSwitchIgmpProxyDomainConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.15.5.1 |
hpSwitchIgmpProxyDomainIdThe domain id that uniquely identifies a row
in the IGMP proxy domain configuration table. Integer32 .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.1 |
hpSwitchIgmpProxyDomainStatusThe status of a IGMP proxy domain configuration
entry. Allows creation/deletion of the
IGMP proxy domain entry. Row cannot be deleted if
the IGMP proxy domain is associated with a VLAN.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.2 |
hpSwitchIgmpProxyDomainNameThe IGMP proxy domain name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.3 |
hpSwitchIgmpProxyDomainIpThe IGMP proxy domain IP.rw IpAddress .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.4 |
hpSwitchIgmpProxyMcastLowerIpThe IGMP proxy domain's lower multicast IP.rw IpAddress .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.5 |
hpSwitchIgmpProxyMcastUpperIpThe IGMP proxy domain's upper multicast IP.rw IpAddress .1.3.6.1.4.1.25506.11.1.7.1.15.5.1.6 |
hpSwitchBasicConfigMIBThis MIB module describes objects for basic
switch configuration. MODULE-IDENTITY .1.3.6.1.4.1.25506.11.1.7.1.29 |
IMPORTSThis MIB module describes objects for basic
switch configuration. Unknown .1.3.6.1.4.1.25506.11.1.7.1.29 |
hpSwitchBasicConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.1 |
hpSwitchNotificationObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.1.0 |
hpSwitchStartupConfigSourceIndicate the method of change to startup config
was initiated.ro Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.1 |
hpSwitchStartupConfigSourceIPAddrTypeIndicates the source address type of network agent
which made a change. Not valid (set to zero)
if change is made via CLI on system console.ro InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.2 |
hpSwitchStartupConfigSourceIPAddrIndicates the source address of network agent
which made a change. Not valid (set to zero)
if change is made via CLI on system console.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.3 |
hpSwitchStartupConfigSourceUsernameIndicates the username of CLI user making the
change to startup config. Zero-string if username
is not set or change is made via SNMPro DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.4 |
hpSwitchStartupConfigThrottledIndicates if notification throttle was activated
and one or more notifications were dropped.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.5 |
hpSwitchStartupConfigChangeThe hpSwitchStartupConfigChange
notification signifies that switch's startup
config was modified by user/manager.
Notifications might be buffered on the system to
be sent after throttle delay. In some cases,
notifications will be dropped. At such event
the next transmitted notification will set
flag hpSwitchStartupConfigThrottled NOTIFICATION-TYPE .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.6 |
hpSwitchRunningConfigChangeNotification of a running configuration change
event as recorded in hpSwitchRunningCfgChgTable. NOTIFICATION-TYPE .1.3.6.1.4.1.25506.11.1.7.1.29.1.0.7 |
hpSwitchSaveConfigWhen this object is set to to 'saveConfig' it
results in saving the running configuration of the
switch to flash. The saved configuration becomes
the boot-up configuration of the switch when it boots
next time. When read, this object always returns
'noConfigSave'.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.1 |
hpSwitchAliasTableTable of alias configurations for CLI commands.
This table contains information about name of the
alias and the corresponding CLI command. SEQUENCE OF HpSwitchAliasEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.2 |
hpSwitchAliasEntryA row in the alias config table. HpSwitchAliasEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.2.1 |
hpSwitchAliasNameName of the alias which uniquely identifies
alias configuration table. 'hpSwitchAliasName' can be
used in place of 'hpSwitchAliasCommand` on the CLI.
Maximum allowed length for alias name is 32 characters. DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.2.1.1 |
hpSwitchAliasCommandCLI command for which 'hpSwitchAliasName' can be
used in CLI. Maximum allowed length for alias command
is 255 characters. This object is required to create
an entry in the table.rw OCTET STRING .1.3.6.1.4.1.25506.11.1.7.1.29.1.2.1.2 |
hpSwitchAliasConfigRowStatusControls creation/deletion of entries
in alias table. Row cant be created when
'hpSwitchAliasCommand' is of zero length.
Row transition to 'notReady' or
'notInService' states are not allowed.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.29.1.2.1.3 |
hpSwitchACLConfig OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.1.3 |
hpSwitchAclLogtimeoutConfigACL deny entries can be logged to the syslog server.
Log timeout is the period the switch waits before sending
updates about any ACL deny matches to the syslog server.
The same log timer will be used for ipv4 and ipv6 logging.
The configurable value is from 30 to 300.Maximum limit is given
as 65535 so that if the value is increased in the future, the mib need
not be modified.rw Integer32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.3.1 |
hpicfPortCopyNameTableThis table contains Mirroring Destination name String. SEQUENCE OF HpicfPortCopyNameEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.4 |
hpicfPortCopyNameEntryAn entry in the hpicfPortCopyNameEntry contains
Mirroring Destination name string. HpicfPortCopyNameEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.4.1 |
hpicfPortCopyNameMirroring Destination name string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.29.1.4.1.1 |
hpSwitchDefaultLogonThis indicates whether switch should boot to CLI (default)
or menu. The changes takes effect after rebooting the
switch.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.5 |
hpSwitchChassisLocateTableThis table is contains information about the current
state of all the chassis locate LEDs. SEQUENCE OF HpSwitchChassisLocateEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.6 |
hpSwitchChassisLocateEntryContains information about the current state of a
particular chassis LED. HpSwitchChassisLocateEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.6.1 |
hpSwitchChassisLocateStateThe current state of the chassis LED. The state is
set to 'off' by default.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.6.1.1 |
hpSwitchChassisLocateDurationThe duration for which the current LED state is
to be maintained. The minimum value is 60 and the
maximum value is 86400. The 'off' state does not
require a duration. A get request for the duration
when the state is 'off' will return the default
duration value.rw Integer32 UNITS "seconds" .1.3.6.1.4.1.25506.11.1.7.1.29.1.6.1.2 |
hpSwitchModules OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.1.7 |
hpSwitchModuleInfoTableA table describing all modules
that can be supported by the device. SEQUENCE OF HpSwitchModuleInfoEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.1 |
hpSwitchModuleInfoEntryThe information regarding the module type
in the switch. This table lists all the
supported module types. The supported module type
will have the equivalent module name. HpSwitchModuleInfoEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.1.1 |
hpSwitchModuleInfoModIdThe module Id. This is a sequence number Integer32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.1.1.1 |
hpSwitchModuleInfoModTypeThe module type in the switch.
This is the Jnumber string that is
supported on the device.ro DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.1.1.2 |
hpSwitchModuleConfigTableA table to configure the module
type for a specific module. SEQUENCE OF HpSwitchModuleConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.2 |
hpSwitchModuleConfigEntryConfiguration of module type for a
specific module. Configuration of
module type on an already configured
module is not allowed. HpSwitchModuleConfigEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.2.1 |
hpSwitchModuleConfigModTypeThe module type in the switch.
This is the Jnumber supported
on the device. The supported
types are listed in hpSwitchModuleInfoTable.rw DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.2.1.1 |
hpSwitchModuleConfigModNameThe module name in the switch.ro DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.7.2.1.2 |
hpSwitchWebSupportUrlURL for the web interface support page.rw DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.8 |
hpSwitchStartupConfigSeqNumThis is the value of the global startup-config
sequential number. Every change to startup-config
increments the value by 1. Must be stored in
non-volatile memory to be carried over the system boot.rw Unsigned32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.9 |
hpSwitchStartupConfigNotifyEnableIndicates whether the SNMP entity is permitted
to generate hpSwitchStartupConfigChange notifications.
Default is disabled.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.10 |
hpSwitchImplicitConfigSaveThis object is to enable/disable the implicit
write-memory (saving the running-config to the
flash) done after every successful SNMP
set operation.
When set to 'enable', config changes are written to
the flash which results in slow performance for
these set operations.
To get faster processing while doing large number
of continuous SNMP set operations, this object can be
set to 'disable'; And,once the SNMP set operations are
done, 'hpSwitchSaveConfig' MIB object can be used
to save the running-config to the flash.
This object will not be saved across a re-boot,
and will always be set to 'enable' at boot.
It is advisable to set this MIB object to
'disable' only when there are a lot of
continuous SNMP set operations e.g. a script
executing a large number of SNMP set operations.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.11 |
hpSwitchRunningCfgChgObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.1.12 |
hpSwitchRunningCfgChgNotifyEnableIndicates whether the SNMP entity is permitted
to generate hpSwitchRunningConfigChange notifications.
Default is disabled.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.1 |
hpSwitchRunningCfgChgTransmitIntervalSpecifies the transmission interval in seconds
for sending running config change traps. Only
one running config change trap is sent in this
time interval. Default value is 0, indicating
there is no limit on sending running config
change traps.rw Unsigned32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.2 |
hpSwitchRunningCfgChgLatestDateAndTimeIndicates the date and time of the
most recent running config change.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.3 |
hpSwitchRunningCfgChgCountThe total number of running config changes
since last reboot.ro Counter32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.4 |
hpSwitchRunningCfgChgEntriesBumpedThe number of times the oldest entry in
hpSwitchRunningCfgChgTable was discarded
to make room for a new entry.ro Counter32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.5 |
hpSwitchRunningCfgChgEventTableA table of latest 32 running configuration change
events. SEQUENCE OF HpSwitchRunningCfgChgEventEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6 |
hpSwitchRunningCfgChgEventEntryInformation about running configuration
change event on this switch. HpSwitchRunningCfgChgEventEntry .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1 |
hpSwitchRunningCfgChgEventTableIndexThe Index for hpSwitchRunningCfgChgTable. Integer32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.1 |
hpSwitchRunningCfgChgEventIdIdentifies a specific running config change.
Monotonically increasing values will be
assigned by the system to each event as it
occurs. If the system is reset, these event ID
values will be reset as well.ro Unsigned32 .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.2 |
hpSwitchRunningCfgChgEventMethodIndicates the source through which change to
running config was initiated.ro Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.3 |
hpSwitchRunningCfgChgEventSourceIPAddrTypeIndicates the source address type of network agent
which made a change. This object value is set to an
address type of unknown when not applicable.ro InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.4 |
hpSwitchRunningCfgChgEventSourceIPAddrIndicates the source address of network agent
which made a running config change. The value
is an address of length 0 (unknown(0)) if not
available or not applicable.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.5 |
hpSwitchRunningCfgChgEventUsernameIndicates the username of the user making the change
the change to running config. Empty string (length 0)
if username is not available or not applicable.ro DisplayString .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.6 |
hpSwitchRunningCfgChgEventDateAndTimeIndicates the date and time of the running
config change.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.25506.11.1.7.1.29.1.12.6.1.7 |
hpSwitchSecureModeLevelIndicates current Secure-Mode Level of switch
standard : switch operates with standard security
capabilities.
enhanced : switch operates with enhanced security
capabilities for configurations to satisfy FIPS
140-2 requirements.The default level is standard.rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.13 |
hpSwitchCdpRunModeIndicates the mode of CDP processing. This variable
has no effect when CDP is disabled (cdpGlobalRun = FALSE).rw Enumeration .1.3.6.1.4.1.25506.11.1.7.1.29.1.14 |
hpSwitchBasicConfigConformance OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.2 |
hpSwitchBasicConfigCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.2.1 |
hpSwitchBasicConfigGroups OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.2.2 |
hpSwitchBasicNotificationGroups OBJECT IDENTIFIER .1.3.6.1.4.1.25506.11.1.7.1.29.2.3 |