H3C-HPEOC-MIB
The objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification.
Main OID:
h3cHPEOC.1.3.6.1.4.1.2011.10.2.84
40
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
40 total| Object Name |
|---|
h3cHPEOCThe objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification. MODULE-IDENTITY .1.3.6.1.4.1.2011.10.2.84 |
h3cHPEOCSystem OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.84.1 |
h3cHPEOCCltVlanTypeControl EOC CLT's VLAN type, ieee8021q : 802.1q VLAN mode, portbased : portbased VLAN mode.rw Enumeration .1.3.6.1.4.1.2011.10.2.84.1.1 |
h3cHPEOCCltVlanManTableThis table implements the management of CLT(Coax Line Terminal) VLAN. SEQUENCE OF H3cHPEOCCltVlanManEntry .1.3.6.1.4.1.2011.10.2.84.1.2 |
h3cHPEOCCltVlanManEntryThe entry of the table h3cHPEOCCltVlanManTable. H3cHPEOCCltVlanManEntry .1.3.6.1.4.1.2011.10.2.84.1.2.1 |
h3cHPEOCCltEthPortTypeControl CLT ethernet ports' type, normal : port which used for normal translation, debug : port which used for debug.rw Enumeration .1.3.6.1.4.1.2011.10.2.84.1.2.1.1 |
h3cHPEOCCltSysManTableThis table implements the management of CLT(Coax Line Terminal). SEQUENCE OF H3cHPEOCCltSysManEntry .1.3.6.1.4.1.2011.10.2.84.1.3 |
h3cHPEOCCltSysManEntryThe entry of the table h3cHPEOCCltSysManTable. H3cHPEOCCltSysManEntry .1.3.6.1.4.1.2011.10.2.84.1.3.1 |
h3cHPEOCCltDescrSet the description of CLT.rw DisplayString .1.3.6.1.4.1.2011.10.2.84.1.3.1.1 |
h3cHPEOCCltFwVersionEOC firmware version. If the object length is zero, it means the version is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.3.1.2 |
h3cHPEOCCnuSysManTableThis table implements the management of CNUs. SEQUENCE OF H3cHPEOCCnuSysManEntry .1.3.6.1.4.1.2011.10.2.84.1.4 |
h3cHPEOCCnuSysManEntryThe entry of the table h3cHPEOCCnuSysManTable. H3cHPEOCCnuSysManEntry .1.3.6.1.4.1.2011.10.2.84.1.4.1 |
h3cHPEOCCnuBcastControlBroadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.4.1.1 |
h3cHPEOCCnuAnonymStatusAnonymity status. true(1) - the user which uses the CNU is anonymous. false(2) - the user which uses the CNU has an account.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.4.1.2 |
h3cHPEOCCnuMacLimitConfigure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU.rw Unsigned32 .1.3.6.1.4.1.2011.10.2.84.1.4.1.3 |
h3cHPEOCCltAutoUpgradeAuto upgrade Status. true(1) - The firmware of the CNU will be auto changed by CLT. false(2)- The firmware of the CNU will not be auto changed.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.5 |
h3cHPEOCOnLineCnuNumberThe total number of the online CNU(s).ro Integer32 .1.3.6.1.4.1.2011.10.2.84.1.6 |
h3cHPEOCCpuMacAddressEOC CPU's MAC address.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.7 |
h3cHPEOCOffLineCnuNumberThe total number of the offline CNU(s).ro Integer32 .1.3.6.1.4.1.2011.10.2.84.1.8 |
h3cHPEOCDownLoadCNUFWResultDownload CNU firmware result.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.9 |
h3cHPEOCCltAutoUpgradeTypeType of auto upgrade status. It depends on h3cHPEOCCltAutoUpgrade status. flash - The CLT auto upgrade the firmware inside its flash to the CNUs. ftp - First download the firmware from FTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs. tftp - First download the firmware from TFTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs.rw Enumeration .1.3.6.1.4.1.2011.10.2.84.1.10 |
h3cHPEOCAutoUpObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.84.1.11 |
h3cHPEOCServerAddressThe address of remote host acting as server for operation. The default value is 0.0.0.0rw IpAddress .1.3.6.1.4.1.2011.10.2.84.1.11.1 |
h3cHPEOCServerUserWhen using ftp to transfer files, the user name must be specified through this node. It contains 1 to 30 characters.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.11.2 |
h3cHPEOCServerPasswordRemote user password for copying via ftp protocol. Optionally, this object may be ignored for protocols other than ftp. It contains 1 to 31 characters.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.84.1.11.3 |
h3cHPEOCCableInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.84.2 |
h3cHPEOCCableInfoTableThis table defines the primary parameters of the cable information. SEQUENCE OF H3cHPEOCCableInfoEntry .1.3.6.1.4.1.2011.10.2.84.2.1 |
h3cHPEOCCableInfoEntryThe entry of the table h3cHPEOCCableInfoTable. H3cHPEOCCableInfoEntry .1.3.6.1.4.1.2011.10.2.84.2.1.1 |
h3cHPEOCFECErrorsThe cable port's FEC bits errors ratio. FEC means the payload Forward Error Correction. It's a technology of controlling errors. Packets in transmission is checked by the receiver, if error occurs, the receiver will announce the sender to resend.ro Counter64 .1.3.6.1.4.1.2011.10.2.84.2.1.1.1 |
h3cHPEOCAvgBitsPerCarrierThe cable port's average bits per carrier.ro Unsigned32 .1.3.6.1.4.1.2011.10.2.84.2.1.1.2 |
h3cHPEOCAvgSNRPerCarrierThe cable port's signal noise ratio(SNR) bits per carrier.ro Integer32 .1.3.6.1.4.1.2011.10.2.84.2.1.1.3 |
h3cHPEOCAvgInPBCRCErrorsThe input PB CRC errors on average.ro Unsigned32 .1.3.6.1.4.1.2011.10.2.84.2.1.1.4 |
h3cHPEOCInTotalPktsThe total number of packets(including bad packets) received on this interface.ro Counter64 .1.3.6.1.4.1.2011.10.2.84.2.1.1.5 |
h3cHPEOCAvgOutPowerThe cable port's power sent on average, the unit is db.ro Integer32 .1.3.6.1.4.1.2011.10.2.84.2.1.1.6 |
h3cHPEOCAvgOutPBCRCErrorsThe cable port's physical block(PB) cyclic redundancy check(CRC) errors sent on average.ro Unsigned32 .1.3.6.1.4.1.2011.10.2.84.2.1.1.7 |
h3cHPEOCOutTotalPktsThe total count of the packets(including bad packets) sent on this interface.ro Counter64 .1.3.6.1.4.1.2011.10.2.84.2.1.1.8 |
h3cHPEOCBitPerSymbolTableThis table defines the bits per symbol parameters of the cable line. SEQUENCE OF H3cHPEOCBitPerSymbolEntry .1.3.6.1.4.1.2011.10.2.84.2.2 |
h3cHPEOCBitPerSymbolEntryThe entry of the table h3cHPEOCBitPerSymbolTable. H3cHPEOCBitPerSymbolEntry .1.3.6.1.4.1.2011.10.2.84.2.2.1 |
h3cHPEOCBitPerSymbolIndexThe index of the h3cHPEOCBitPerSymbolTable. Unsigned32 .1.3.6.1.4.1.2011.10.2.84.2.2.1.1 |
h3cHPEOCBitPerSymbolh3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed frequency. Each 4 bits stand for one value, all the values picking-up will make up a cable bit map.ro OCTET STRING .1.3.6.1.4.1.2011.10.2.84.2.2.1.2 |