Home/Catalog/H3C-FC-FLOGIN-MIB

H3C-FC-FLOGIN-MIB

AI MIB Summary

The H3C-FC-FLOGIN-MIB monitors Fibre Channel fabric login states, session establishment parameters, and port authentication details on H3C SAN switches to track active N_Port and F_Port connections within the storage area network.

This MIB module is for representing fabric login information.
Main OID:
h3cFcFLogin.1.3.6.1.4.1.2011.10.2.127.3
15
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

15 total
Object Name
h3cFcFLoginThis MIB module is for representing fabric login information.
MODULE-IDENTITY
.1.3.6.1.4.1.2011.10.2.127.3
h3cFcFLoginMibObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.127.3.1
h3cFcFLoginTableA table of Fibre Channel related service parameters used to represent the fabric login information in accord with each Nx_Port attached to a particular Fibre Channel port in a particular VSAN (Virtual Storage Area Network). Each entry is created by a fabric switch when an Nx_Port successfully logged in to it explicitly or implicitly, and is deleted when the port logged out.
SEQUENCE OF H3cFcFLoginEntry
.1.3.6.1.4.1.2011.10.2.127.3.1.1
h3cFcFLoginEntryA group of Fibre Channel related service parameters used to represent fabric login information of a specific Nx_Port.
H3cFcFLoginEntry
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1
h3cFcFLoginIndexThe index of current fabric login entry. The Fibre Channel address identifier is used to identify the associated Nx_Port of this entry.
H3cFcAddressId (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.1
h3cFcFLoginPortNodeWWNThe world wide name of the Remote Node to which the logged-in Nx_Port belongs.ro
H3cFcNameId (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.2
h3cFcFLoginPortWWNThe world wide name of the logged-in Nx_Port.ro
H3cFcNameId (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.3
h3cFcFLoginPortFcIdThe Fibre Channel address identifier that has been assigned by the fabric to the logged-in Nx_Port.ro
H3cFcAddressId (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.4
h3cFcFLoginRxBbCreditThe maximum number of buffers available for a recipient to receive frames from the logged-in Nx_Port in Class2, Class3. The object is used in the buffer-to-buffer flow control from the logged-in Nx_Port to Fx_Port.ro
H3cFcBbCredit (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.5
h3cFcFLoginTxBbCreditThe total number of buffers available for a sender to transmit frames to the logged-in Nx_Port in Class2, Class3. The object is used in the buffer-to-buffer flow control from Fx_Port to the logged-in Nx_Port.ro
H3cFcBbCredit (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.6
h3cFcFLoginClass2RxMTUThe object specifies the Maximum Transmission Unit of an Fibre Channel frame that can be received by the logged-in Nx_Port in Class 2 service.ro
H3cFcRxMTU (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.7
h3cFcFLoginClass3RxMTUThe object specifies the Maximum Transmission Unit of an Fibre Channel frame that can be received by the logged-in Nx_Port in Class 3 service.ro
H3cFcRxMTU (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.8
h3cFcFLoginSuppClassRequestedThe object indicating the supported Classes that the logged-in Nx_Port has requested.ro
H3cFcClassOfServices (H3C-FC-TC-MIB)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.9
h3cFcFLoginClass2ReqAgreedThe object indicating whether the Fx_Port has agreed to support Class 2 delivery that the logged-in Nx_Port requested. It's meaningful only when the Class 2 delivery has been requested.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.10
h3cFcFLoginClass3ReqAgreedThe object indicating whether the Fx_Port has agreed to support Class 3 delivery that the logged-in Nx_Port requested. It's meaningful only when the Class 3 delivery has been requested.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.10.2.127.3.1.1.1.11