H3C-CATV-TRANSCEIVER-MIB
The H3C-CATV-TRANSCEIVER-MIB enables SNMP-based monitoring and configuration of H3C Community Antenna Television (CATV) transceiver modules, specifically exposing parameters such as optical power levels, bias currents, temperature, and voltage status for network health assessment.
Imported Objects
Objects
20 total| Object Name |
|---|
h3cCATVTransceiverThe objects in this MIB module are used to manage and display common configuration for CATV(Community Antenna Television) transceiver module. MODULE-IDENTITY .1.3.6.1.4.1.2011.10.2.94 |
h3cCATVTransStatus OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.1 |
h3cCATVTransStatusScalarObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.1.1 |
h3cCATVTransStateThe state of CATV transceiver.ro Enumeration .1.3.6.1.4.1.2011.10.2.94.1.1.1 |
h3cCATVTransInputPwrThe input power of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "dbm" .1.3.6.1.4.1.2011.10.2.94.1.1.2 |
h3cCATVTransOutputLevelThe output level of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "dbuv" .1.3.6.1.4.1.2011.10.2.94.1.1.3 |
h3cCATVTransTemperatureThe temperature of CATV transceiver. If transceiver is not on site, the value should be zero.ro Integer32 UNITS "centigrade" .1.3.6.1.4.1.2011.10.2.94.1.1.4 |
h3cCATVTransceiverMan OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.2 |
h3cCATVTransCtrlScalarObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.2.1 |
h3cCATVTransInputPwrLowerThrA threshold for the CATV transceiver's input power. When the input power of CATV transceiver is lower than threshold, a trap should be generated.rw Integer32 UNITS "dbm" .1.3.6.1.4.1.2011.10.2.94.2.1.1 |
h3cCATVTransOutputLvlLowerThrA threshold for the CATV transceiver's output level. When the output level of CATV transceiver is lower than threshold, a trap should be generated.rw Integer32 UNITS "dbuv" .1.3.6.1.4.1.2011.10.2.94.2.1.2 |
h3cCATVTransTempratureUpperThrA threshold for the CATV transceiver's temperature. When the temperature of CATV transceiver is higher than threshold, a trap should be generated.rw Integer32 UNITS "" .1.3.6.1.4.1.2011.10.2.94.2.1.3 |
h3cCATVTansTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.3 |
h3cCATVTransTrapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.94.3.0 |
h3cCATVTransInputPwrTrapA h3cCATVTransInputPwrTrap notification is sent when the input power of CATV transceiver is lower than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.1 |
h3cCATVTransInputPwrReTrapA h3cCATVTransInputPwrReTrap notification is sent when the input power of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.2 |
h3cCATVTransOutputLvlTrapA h3cCATVTransOutputLvlTrap notification is sent when the output level of CATV transceiver is lower than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.3 |
h3cCATVTransOutputLvlReTrapA h3cCATVTransOutputLvlReTrap notification is sent when the output level of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.4 |
h3cCATVTransTemperatureTrapA h3cCATVTransTemperatureTrap notification is sent when the temperature of CATV transceiver is higher than the threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.5 |
h3cCATVTransTemperatureReTrapA h3cCATVTransTemperatureReTrap notification is sent when the temperature of CATV transceiver recovered from the last trap. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.94.3.0.6 |
More MIBs from Huawei
Browse all HuaweiMIBs →The HUAWEI-MIB module provides a unified namespace for monitoring and managing generic system resources, interface statistics, and hardware telemetry across Huawei network devices. It serves as the foundational OID repository for retrieving standard operational data, including CPU utilization, memory usage, interface counters, and device status, required for comprehensive network management via SNMP.
Standard SNMP MIB module defining data structures for HUAWEI-SERVER-IBMC-MIB.
The HUAWEI-XPON-MIB module enables Network Management Systems to monitor and configure GPON and EPON optical line terminals and optical network units, specifically tracking PON port status, optical power levels, bandwidth allocation, and subscriber session states.
SNMP MIB module
The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.
The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.