GDCUAS7624-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for GDCUAS7624-MIB.
110
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
110 total| Object Name |
|---|
gdc OBJECT IDENTIFIER .1.3.6.1.4.1.498 |
RFC1155-SMI Unknown .1.3.6.1.4.1.498 |
niudiu OBJECT IDENTIFIER .1.3.6.1.4.1.498.18 |
uas7624System OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1 |
uas7624Version OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.1 |
uas7624MIBversionIdentifies the version of the MIB. The format of the version
is x.yzT, where 'x' identifies the major revision number, 'y'
identifies the minor revision number, 'z' identifies the
typographical revision, and T identifies the test revision.
Acceptable values for the individual revision components are
as follows:
x: 1 - 9
y: 0 - 9
z: 0 - 9
T: A - Z
Upon formal release, no designation for the test revision will
be present.ro Unknown .1.3.6.1.4.1.498.18.1.1.1 |
uas7624VersionTableThe 7624 version table SEQUENCE OF Uas7624VersionEntry .1.3.6.1.4.1.498.18.1.1.2 |
uas7624VersionEntryAn entry in the GDC uas7624System Version Table. Uas7624VersionEntry .1.3.6.1.4.1.498.18.1.1.2.1 |
uas7624VersionIndexInteger value which uniquely identifies the uas7624
to which this entry is applicable.
For entire table:
SCinstance: [L]ine=5 [i]nterface=0ro SCinstance .1.3.6.1.4.1.498.18.1.1.2.1.1 |
uas7624FirmwareRevThe version number of the firmware, to allow products
to know which revision is installed. The released
version number is sequenced from
::= { uas7624VersionEntry 2 }
uas7624CardType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTIONro DisplayString .1.3.6.1.4.1.498.18.1.1.2.1.4 |
uas7624Maintenance OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.2 |
uas7624MaintenanceTableThe table describes the maintenance objects for uas7624. SEQUENCE OF Uas7624MaintenanceEntry .1.3.6.1.4.1.498.18.1.2.1 |
uas7624MaintenanceEntryAn entry in the GDC 7624 Maintenance Table. Uas7624MaintenanceEntry .1.3.6.1.4.1.498.18.1.2.1.1 |
uas7624MaintenanceLineIndexInteger value which uniquely identifies
the uas7624 to which this entry is applicable.
See DESCRIPTION's below for ranges.ro SCinstance .1.3.6.1.4.1.498.18.1.2.1.1.1 |
uas7624SoftResetSupports the action of soft resetting the unit.
When this object is set to reset(2), then the unit
performs a soft reset, whose meaning is specific to
the type of unit being managed. The value of norm(1)
will be returned when the reset is complete.
The value of norm(1) can not be set by management.
SCinstance: [L]ine=1-5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.2 |
uas7624DefaultInitThis is used to allow the NonVolatile Configuration to
be set to a factory default state. When this value is set
to factoryDefault(2) the unit will perform a reset to make
the default configuration take affect.
The value of normal(1) will be returned when the
initialization is complete.
The value of normal(1) can not be set by management.
SCinstance: [L]ine=1-5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.3 |
uas7624ResetMajorAlarmThis variable is used.
SCinstance: [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.4 |
uas7624ResetMinorAlarmThis variable is used.
SCinstance: [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.5 |
uas7624ResetStatisticsThis variable is used to reset the performance intervals.
When it is set to reset, the performance tables and uas7624Valid
intervals are reset to zero. The value of norm(1) can not be set
by management.
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.6 |
uas7624StatLastInitializedThe elapsed time since the statistics were last initialized.
This will be zero'd when uas7624ResetStatistics is reset(2).
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.498.18.1.2.1.1.7 |
uas7624ValidIntervalsThe number of previous intervals for which
valid data was collected. The value will be 96 for the T1
interface and 16 for the loop interface
unless the interface was brought on-line within
the last 24 hours, in which case the value will
be the number of complete 15 minute intervals
the since interface has been online.
Note: The loop interface values are 1-16, T1 values are 1-96.
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro INTEGER .1.3.6.1.4.1.498.18.1.2.1.1.8 |
uas7624SysUpTimeThis variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.
SCinstance: [L]ine=5 [i]nterface=0ro INTEGER .1.3.6.1.4.1.498.18.1.2.1.1.9 |
uas7624LedStatusReturns a bitwise snapshot of the front panel LED state.
based on the Line:
For SCinstance: [L]ine=1-4 [i]nterface=0
key
01 = SOLID GREEN Good Condition and in Sync
10 = SOLID RED Alarm State (no Current or no Sync)
11 = FLASHING GREEN Loop in Test
1.7 - n/a
1.6 - f/u
1.5 - 2^1
1.4 - 2^0 Loop 1 (01, 10, 11)
1.3 - f/u
1.2 - f/u
1.1 - 2^1
1.0 - 2^0 Loop 2 (01, 10, 11)
2.7 - f/u
2.6 - f/u
2.5 - f/u
2.4 - f/u
2.3 - 2^1
2.2 - 2^0 Loop 3 (01, 10, 11)
2.1 - f/u
2.0 - f/u
For SCinstance: [L]ine=5 [i]nterface=0
1.7 - n/a
1.6 - f/u
1.5 - f/u
1.4 - f/u
1.3 - f/u
1.2 - f/u
1.1 - f/u
1.0 - f/u
2.7 - n/a
2.6 - f/u
2.5 - Network AIS 1:RED (Alarm Indication Signal)
2.4 - Network LVC 1:RED (Line Code Violation)
2.3 - Network LOS 1:RED (Loss Of Signal)
2.2 - Network OOF 1:RED (Out Of Frame)
2.1 - ALARM 1: FLASHING RED (AIS, LVC, LOS, or OOF)
2.0 - Test Mode 1: RED (in test mode)ro OCTET STRING .1.3.6.1.4.1.498.18.1.2.1.1.10 |
uas7624AlarmStatusReturns a bit-wise Status of alarms with
both masked and unmasked.
For SCinstance: [L]ine=1-4 [i]nterface=0
1.7 - f/u
1.6 - Power-up
1.5 - f/u
1.4 - Loop 1 OOS
1.3 - Loop 1 Sealing Current Non-Continuity
1.2 - Loop 1 ES
1.1 - Loop 1 SES
1.0 - Loop 1 UAS
2.7 - f/u
2.6 - f/u
2.5 - f/u
2.4 - Loop 2 OOS
2.3 - Loop 2 Sealing Current Non-Continuity
2.2 - Loop 2 ES
2.1 - Loop 2 SES
2.0 - Loop 2 UAS
3.7 - f/u
3.6 - f/u
3.5 - f/u
3.4 - Loop 3 OOS
3.3 - Loop 3 Sealing Current Non-Continuity
3.2 - Loop 3 ES
3.1 - Loop 3 SES
3.0 - Loop 3 UAS
4.7 - f/u
4.6 - f/u
4.5 - Loop 1 Major
4.4 - Loop 1 Minor
4.3 - Loop 2 Major
4.2 - Loop 2 Minor
4.1 - Loop 3 Major
4.0 - Loop 3 Minor
For SCinstance: [L]ine=5 [i]nterface=0
1.7 - f/u
1.6 - LOS
1.5 - LOF
1.4 - AIS
1.3 - f/u
1.2 - Received Yellow
1.1 - f/u
1.0 - f/u
2.7 - f/u
2.6 - LCV
2.5 - CRC
2.4 - f/u
2.3 - f/u
2.2 - f/u
2.1 - f/u
2.0 - f/u
3.7 - f/u
3.6 - f/u
3.5 - f/u
3.4 - f/u
3.3 - f/u
3.2 - f/u
3.1 - f/u
3.0 - f/u
4.7 - f/u
4.6 - ES
4.5 - BES
4.4 - SES
4.3 - UAS
4.2 - f/u
4.1 - f/u
4.0 - Power-upro OCTET STRING .1.3.6.1.4.1.498.18.1.2.1.1.11 |
uas7624LoopStateA setting of inhibit(1) stops operation on the loop
and a setting of enable(2) starts operation on the
loop.
SCinstance: [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.12 |
uas7624ConfigModeThis variable is used to report the mode, either soft or
hard, of the the uas7624. If the unit is in hard mode
then the options in the uas7624ConfigTable are read-only.
If the unit is in soft mode then the options in the
uas7624ConfigTable are read-write.
SCinstance: [L]ine=5 [i]nterface=0ro Enumeration .1.3.6.1.4.1.498.18.1.2.1.1.13 |
uas7624Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.3 |
uas7624ConfigTableThe GDC Configuration table. SEQUENCE OF Uas7624ConfigEntry .1.3.6.1.4.1.498.18.1.3.1 |
uas7624ConfigEntryThe GDC Configuration table entry. Uas7624ConfigEntry .1.3.6.1.4.1.498.18.1.3.1.1 |
uas7624ConfigIndexInteger value which uniquely identifies the uas7624
to which this entry is applicable.
For entire table:
SCinstance: [L]ine=5 [i]nterface=0ro SCinstance .1.3.6.1.4.1.498.18.1.3.1.1.1 |
uas7624NetworkInterfaceTypeSets the transmit range to DSX-1 short or DS-1 longrw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.2 |
uas7624TransmitClockSourceSets the transmit clock source.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.3 |
uas7624PreEqualizationPre-Equalization distancerw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.4 |
uas7624FramingSet the framing for the interface.
Abbreviations are as follows:
eSF - Extended Super Frame
d4 - Super Framerw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.5 |
uas7624LineCodingSets the line coding for the interface.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.6 |
uas7624LineBuildoutSets the line build out for the T1 interface.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.7 |
uas7624FDLModeSets the Facility Data Link Mode.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.8 |
uas7624LoopbackSets the loopback typerw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.9 |
uas7624AISLoopdownSets AIS unloop time where 4 = inhibit,
5 thru 60 = number of secondsrw INTEGER .1.3.6.1.4.1.498.18.1.3.1.1.10 |
uas7624LineBuildoutModeSets the line build out mode for the T1 interface.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.11 |
uas7624FramingModeSet the framing mode.rw Enumeration .1.3.6.1.4.1.498.18.1.3.1.1.12 |
uas7624Diagnostics OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.4 |
uas7624DiagTableThe GDC 7624 Diagnostics table. Information in the entries of
this table support diagnostics testing, both active testing
via patterns, and passive testing via loopbacks. SEQUENCE OF Uas7624DiagEntry .1.3.6.1.4.1.498.18.1.4.1 |
uas7624DiagEntryThe GDC 7624 Diagnostics table entry. Uas7624DiagEntry .1.3.6.1.4.1.498.18.1.4.1.1 |
uas7624DiagIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.
See DESCRIPTION's below for ranges.ro SCinstance .1.3.6.1.4.1.498.18.1.4.1.1.1 |
uas7624DiagConfigSelects test to run. (1) stops test.
SCinstance:
stopTest(1) [L]ine=1-5 [i]nterface=0-3
lineLoopback(2) [L]ine=5 [i]nterface=0
payloadLoopback(3) [L]ine=5 [i]nterface=0
digitalLoopback(4) [L]ine=1-4 [i]nterface=1-3
selfTest(5) [L]ine=1-4 [i]nterface=1-3
rdl(6) [L]ine=1-4 [i]nterface=1-3
rdlSelfTest(7) [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.4.1.1.2 |
uas7624T1TestLimitSelects the duration to run a T1 diagnostic test. The value(1)
noLimit signifies that the test should run indefinitely until
explicitly terminated.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.4.1.1.3 |
uas7624T1TestExecutionStatusThis variable reports the status of a T1 test.
notInTest(1) indicates a test is not running.
testInProgress(2) indicates that a test is
currently running. testCompleted(4) indicates that a test has run
and is completed.
testCompletedNotInTest(5) indicates that a test has
completed and it is no longer in test.
SCinstance: [L]ine=5 [i]nterface=0ro Enumeration .1.3.6.1.4.1.498.18.1.4.1.1.4 |
uas7624T1TestExceptionsIndicates T1 test exceptions that have occurred that may affect
interpretation of the test results.
The value of this object is a sum. This sum initially take
the value zero. Then, for each exception, the value
associated with the exception is added to the sum.
The exception values are:
value exception
1 a timed test was preempted so the result
cannot be viewed in relation to the test
duration
2 the results overflowed so the result cannot be
viewed as an absolute value
4 the test was performed while synchronization
could not be performed so the result may not
be accurate.
SCinstance: [L]ine=5 [i]nterface=0ro INTEGER .1.3.6.1.4.1.498.18.1.4.1.1.5 |
uas7624TestResultsThe results of the last T1 diagnostic test. This can be the
current test running or the last completed test.
Note that the interpretation of these results may be affected
by the value of the uas7624TestExceptions object.
This function reads the DIU self test results in
bit errors. 2^20
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro INTEGER .1.3.6.1.4.1.498.18.1.4.1.1.6 |
uas7624ResetTestResultsResets the diagnostic T1 or Loop error count.
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.4.1.1.7 |
uas7624Performance OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.5 |
uas7624CurrentTableThe uas7624 Current table contains various statistics being
collected for the current 15 minute interval. SEQUENCE OF Uas7624CurrentEntry .1.3.6.1.4.1.498.18.1.5.3 |
uas7624CurrentEntryAn entry in the uas7624 Current table. Uas7624CurrentEntry .1.3.6.1.4.1.498.18.1.5.3.1 |
uas7624CurrentIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.
For this table:
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro SCinstance .1.3.6.1.4.1.498.18.1.5.3.1.1 |
uas7624CurrentStatReturns a bitwise snapshot of the interval statistics.
for [L]ine=1-4 [i]nterface=1-3 (SIZE (10))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^1
bit 0 - 2^0 Loop ID
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 4 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 5 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 6 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 FEBE (Far End Block Error Count)
OR,
Returns a bitwise snapshot of the interval statistics.
for [L]ine=5 [i]nterface=0 (SIZE (17))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 1: New Interval
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 12 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 13 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 14 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 15 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 16 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 17 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.18.1.5.3.1.2 |
uas7624IntervalTableThe uas7624 Interval table contains various statistics
collected by each Interface over the previous 24 hours of
operation.
For this table:
SCinstance: [L]ine=1-4 [i]nterface=1-3 [I]nterval=1-15
[L]ine=5 [i]nterface=0 [I]nterval=1-96 SEQUENCE OF Uas7624IntervalEntry .1.3.6.1.4.1.498.18.1.5.4 |
uas7624IntervalEntryAn entry in the DS1 Interval table. Uas7624IntervalEntry .1.3.6.1.4.1.498.18.1.5.4.1 |
uas7624IntervalIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.ro SCinstance .1.3.6.1.4.1.498.18.1.5.4.1.1 |
uas7624IntervalNumberFor the T1 interface: A number between 1 and 96,
where 1 is the most recently completed 15 minute
interval and 96 is the least recently completed 15
minutes interval (assuming that all 96
intervals are valid). For the Loop interfaces:
A number between 1 and 16.ro INTEGER .1.3.6.1.4.1.498.18.1.5.4.1.2 |
uas7624IntervalStatReturns a bitwise snapshot of the interval statistics.
for [L]ine=1-4 [i]nterface=1-3 (SIZE (11))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^1
bit 0 - 2^0 Loop ID
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Interval
Octet 3 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 6 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 7 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 9 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 10 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 11 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 FEBE (Far End Block Error Count)
OR,
Returns a bitwise snapshot of the interval statistics.
for [L]ine=5 [i]nterface=0 (SIZE (16))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 2 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 4 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 5 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 6 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 7 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 8 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 10 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 13 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 14 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 15 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 16 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.18.1.5.4.1.3 |
uas7624TotalTableThe DS1 Total table. 24 hour interval. SEQUENCE OF Uas7624TotalEntry .1.3.6.1.4.1.498.18.1.5.5 |
uas7624TotalEntryAn entry in the DS1 Total table. Uas7624TotalEntry .1.3.6.1.4.1.498.18.1.5.5.1 |
uas7624TotalIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.
For this table:
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro SCinstance .1.3.6.1.4.1.498.18.1.5.5.1.1 |
uas7624TotalStatReturns a bitwise snapshot of the interval statistics.
for [L]ine=1-4 [i]nterface=1-3 (SIZE (14))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^1
bit 0 - 2^0 Loop ID
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^23
bit 1 - 2^22
bit 0 - 2^21
Octet 12 bit 7 - not used
bit 6 - 2^20
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 13 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 14 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 FEBE (Far End Block Error Count)
OR,
Returns a bitwise snapshot of the interval statistics.
for [L]ine=5 [i]nterface=0 (SIZE (17))
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 1: New Interval
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 12 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 13 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 14 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 15 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 16 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 17 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.18.1.5.5.1.2 |
uas7624Recent24HrTableThe Recent24Hr table. 4 hour interval SEQUENCE OF Uas7624Recent24HrEntry .1.3.6.1.4.1.498.18.1.5.6 |
uas7624Recent24HrEntryAn entry in the Recent24Hr table. Uas7624Recent24HrEntry .1.3.6.1.4.1.498.18.1.5.6.1 |
uas7624Recent24HrIndexThe index value which uniquely identifies the interface to
which this entry is applicable. This has the form of a
For this table:
SCinstance: [L]ine=1-4 [i]nterface=1-3ro SCinstance .1.3.6.1.4.1.498.18.1.5.6.1.1 |
uas7624Recent24HrStatReturns a bitwise snapshot of the interval statistics.
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^1
bit 0 - 2^0 Loop ID
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - >65535
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - 2^23
bit 1 - 2^22
bit 0 - 2^21
Octet 12 bit 7 - not used
bit 6 - 2^20
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 13 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 14 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 FEBE (Far End Block Error Count)ro OCTET STRING .1.3.6.1.4.1.498.18.1.5.6.1.2 |
uas7624AlarmConfig OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.6 |
uas7624AlarmConfigTableThis table contains entries that configure Alarm reporting. SEQUENCE OF Uas7624AlarmConfigEntry .1.3.6.1.4.1.498.18.1.6.1 |
uas7624AlarmConfigEntryAn entry in the uas7624 Alarm Configuration table. Uas7624AlarmConfigEntry .1.3.6.1.4.1.498.18.1.6.1.1 |
uas7624AlarmConfigIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.
For this table:
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0ro SCinstance .1.3.6.1.4.1.498.18.1.6.1.1.1 |
uas7624AlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type.
The format of this identifier is an OBJECT IDENTIFIER that has
the following format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y)
where xxx(x) is the administratively assigned family object
identifier (z) is the object identifier for alarms in the family
defined MIB and yyy(y) is the administratively assigned alarm
type identifier for this alarm.ro OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.1.6.1.1.2 |
uas7624AlarmCountWindowThis variable sets/reads the alarm window.
This window is used with the alarm threshold to determine
how long the alarm should be active before reporting.
Default: disabled(1)rw Enumeration .1.3.6.1.4.1.498.18.1.6.1.1.3 |
uas7624AlarmCountThresholdThis function sets/reads the alarm threshold criteria.
This threshold is used along with the the alarm window to
determine the number of instances in a given time frame for
an alarm to occur before the alarm is considered active.
Default: thresGT1(1)rw Enumeration .1.3.6.1.4.1.498.18.1.6.1.1.4 |
uas7624LocalAlarmConfigTableThe uas7624LocalAlarmConfigTable contains entries
that configure alarm reporting to the alarm card. SEQUENCE OF Uas7624LocalAlarmConfigEntry .1.3.6.1.4.1.498.18.1.6.2 |
uas7624LocalAlarmConfigEntryAn entry in the GDC Local Alarm Configuration table. Uas7624LocalAlarmConfigEntry .1.3.6.1.4.1.498.18.1.6.2.1 |
uas7624LocalAlarmConfigIndexInteger value which uniquely identifies the uas7624 to which this
entry is applicable.
For this table:
See DESCRIPTION's below for ranges.ro SCinstance .1.3.6.1.4.1.498.18.1.6.2.1.1 |
uas7624LOSLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.2 |
uas7624LOFLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.3 |
uas7624AISLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.4 |
uas7624YELLOWLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.5 |
uas7624LineCodeViolationLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.6 |
uas7624CRCLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.7 |
uas7624ESLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.10 |
uas7624BESLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.11 |
uas7624SESLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.12 |
uas7624UASLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=1-4 [i]nterface=1-3
[L]ine=5 [i]nterface=0rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.13 |
uas7624OutofSyncLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.14 |
uas7624NoSealingCurrentLocalDisables or enables the alarm on the Major buss or Minor Buss.
SCinstance: [L]ine=1-4 [i]nterface=1-3rw Enumeration .1.3.6.1.4.1.498.18.1.6.2.1.15 |
uas7624 OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2 |
uas7624Alarms OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1 |
uas7624NoResponseAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.1 |
uas7624DiagRxErrAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.2 |
uas7624PowerUpAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.3 |
uas7624LossOfSignalAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.4 |
uas7624LossOfFrameAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.5 |
uas7624AisAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.6 |
uas7624YellowAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.7 |
uas7624OutofSyncAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.8 |
uas7624SealingCurrentNoContAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.9 |
uas7624UASAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.10 |
uas7624ESAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.11 |
uas7624LineCodeViolationAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.12 |
uas7624CRCAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.13 |
uas7624BESAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.14 |
uas7624SESAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.15 |
uas7624MajorBERAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.16 |
uas7624MinorBERAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.18.2.1.17 |