Home/Catalog/GDCSC616-MIB

GDCSC616-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

149
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

149 total
Object Name
gdc
OBJECT IDENTIFIER
.1.3.6.1.4.1.498
RFC1213-MIB
Unknown
.1.3.6.1.4.1.498
bql
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10
bqlMIBVersionThe version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.ro
DisplayString
.1.3.6.1.4.1.498.10.1
bqlWhatAreYouTableThe GDC SC616, DC610, DC612, GT 128 What Are You Table.
SEQUENCE OF BqlWhatAreYouEntry
.1.3.6.1.4.1.498.10.2
bqlWhatAreYouEntryAn entry in the GDC SC616 What Are You table.
BqlWhatAreYouEntry
.1.3.6.1.4.1.498.10.2.1
bqlWhatAreYouIndexThis object is the identifier of the SC616 What Are You table.ro
SCinstance
.1.3.6.1.4.1.498.10.2.1.1
bqlBaseCardTypeThis function returns the value the Base Card Type.ro
Enumeration
.1.3.6.1.4.1.498.10.2.1.2
bqlOptionCardThis indicates whether the option card is installed or not on the DC610 or DC612.ro
Enumeration
.1.3.6.1.4.1.498.10.2.1.3
bqlDTE2CardTypeThis object is the DTE channel 2 plug-in card type on the DC610 or DC612.ro
Enumeration
.1.3.6.1.4.1.498.10.2.1.4
bqlDTE1CardTypeThis object is the DTE channel 1 plug-in card type on the DC610 or DC612 or GT 128.ro
Enumeration
.1.3.6.1.4.1.498.10.2.1.5
bqlCodeRevThis function returns the firmware code level. Example A- ,B-ro
DisplayString
.1.3.6.1.4.1.498.10.2.1.6
bqlAlarmStatusThe current alarms of the unit without the alarm masks.ro
OCTET STRING
.1.3.6.1.4.1.498.10.2.1.7
bqlConfigTableThe GDC SC616, DC610, DC612, GT 128 2B1Q configuration table.
SEQUENCE OF BqlConfigEntry
.1.3.6.1.4.1.498.10.3
bqlConfigEntryA listing of GDC 2B1Q SC616 options.
BqlConfigEntry
.1.3.6.1.4.1.498.10.3.1
bqlConfigIndexA unique index for the Configuration Table.ro
SCinstance
.1.3.6.1.4.1.498.10.3.1.1
bqlConfigChnlIndexA unique channel index for the Configuration Table.ro
Enumeration
.1.3.6.1.4.1.498.10.3.1.2
bqlTestPatternObject to select loop and channel test pattern for SC616, DC610, DC612.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.3
bqlRLTimeoutObject to select loop and channel remote loop time out for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.4
bqlRespRLObject to select loop and channel remote loop response for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.5
bqlRLTypeObject to select loop and channel remote loop type for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.6
bqlBilateralRLObject to select loop and channel bilateral remote loop for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.7
bqlInbandRTSDCDObject to select loop and channel in-band RTS/DCD for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.8
bqlRTSObject to select loop and channel RTS for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.9
bqlRTSCTSDelayObject to select loop and channel RTS/CTS delay for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.10
bqlAntiStreamObject to select loop and channel Anti-streaming for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.11
bqlTXDataElasticBufrObject to select loop and channel transmit data elastic buffer for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.12
bqlRTSCTSDelayTimeObject to select loop and channel RTS to CTS delay time for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.13
bqlAntiStreamTimeObject to select loop and channel anti-streaming time for DC610 and DC612 only.rw
Enumeration
.1.3.6.1.4.1.498.10.3.1.14
bqlConfig1TableThe GDC SC616, DC610, DC612 2B1Q configuration 1 table.
SEQUENCE OF BqlConfig1Entry
.1.3.6.1.4.1.498.10.4
bqlConfig1EntryA listing of GDC 2B1Q SC616 options.
BqlConfig1Entry
.1.3.6.1.4.1.498.10.4.1
bqlConfig1IndexA unique index for the Configuration Table.ro
SCinstance
.1.3.6.1.4.1.498.10.4.1.1
bqlFrontPanelObject used to enable or disable the units front panel switches.rw
Enumeration
.1.3.6.1.4.1.498.10.4.1.2
bqlSoftHardObject used to read how the unit is configured.ro
Enumeration
.1.3.6.1.4.1.498.10.4.1.3
bqlDteStatusObject used to read the status of the DTE interface.ro
OCTET STRING
.1.3.6.1.4.1.498.10.4.1.4
bqlConfig2TableThe GDC SC616 2B1Q configuration 2 table.
SEQUENCE OF BqlConfig2Entry
.1.3.6.1.4.1.498.10.5
bqlConfig2EntryA listing of GDC 2B1Q SC616 options.
BqlConfig2Entry
.1.3.6.1.4.1.498.10.5.1
bqlConfig2IndexA unique index for the Configuration Table.ro
SCinstance
.1.3.6.1.4.1.498.10.5.1.1
bqlMasterTXClkSrcObject to option the Loop master transmit clock source. This is for the SC616 only.rw
Enumeration
.1.3.6.1.4.1.498.10.5.1.2
bqlDiagnosticTableThe GDC SC616 diagnostics table.
SEQUENCE OF BqlDiagnosticEntry
.1.3.6.1.4.1.498.10.6
bqlDiagnosticEntryA listing of GDC SC616 diagnostic tests
BqlDiagnosticEntry
.1.3.6.1.4.1.498.10.6.1
bqlDiagnosticIndexA unique index for the Diagnostic Table.ro
SCinstance
.1.3.6.1.4.1.498.10.6.1.1
bqlDiagnosticChnlIndexA unique channel index for the Channel the test will run on.ro
Enumeration
.1.3.6.1.4.1.498.10.6.1.2
bqlDiagnosticTestThis function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest 16 = line loopback test 32 = terminate test All other values are test combinations such as 9 = selftest and remote loopback.rw
INTEGER
.1.3.6.1.4.1.498.10.6.1.3
bqlDiagnosticLengthThis function selects the test time length. Where 0 is test indefinitely and 1 to 127 are seconds.rw
INTEGER
.1.3.6.1.4.1.498.10.6.1.4
bqlDiagnosticActiveThis function represents the test condition.ro
Enumeration
.1.3.6.1.4.1.498.10.6.1.5
bqlDiagnosticResultsThis function reads the self test results in bit errors.ro
INTEGER
.1.3.6.1.4.1.498.10.6.1.6
bqlSC616Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7
bqlAlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1
bqlNoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.1
bqlDiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.2
bqlPowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.3
bqlLp2B1QOutofSyncAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.4
bqlLpChn1ElasBufrOverUnderFlowAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.5
bqlLpChn2ElasBufrOverUnderFlowAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.6
bqlLpChn1ExtTxClkAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.7
bqlLpChn2ExtTxClkAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.8
bqlLpSealingCurrentNoContinuityAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.7.1.9
bqlSC616LEDStatusTableThe GDC SC616 LED Status Table.
SEQUENCE OF BqlSC616LEDEntry
.1.3.6.1.4.1.498.10.8
bqlSC616LEDEntryAn entry in the GDC SC616 LED Status table.
BqlSC616LEDEntry
.1.3.6.1.4.1.498.10.8.1
bqlSC616LEDIndexThis object is the index of the SC616 LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.8.1.1
bqlSC616LEDStatusThe GDC SC616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - alarm on 1.4 - loop 1 line loopback 1.3 - loop 1 channel 1 send data transitions 1.2 - loop 1 channel 1 receive data transitions 1.1 - loop 1 channel 2 send data transitions 1.0 - loop 1 channel 2 receive data transitions 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - loop 2 line loopback 2.3 - loop 2 channel 1 send data transitions 2.2 - loop 2 channel 1 receive data transitions 2.1 - loop 2 channel 2 send data transitions 2.0 - loop 2 channel 2 receive data transitions 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - loop 3 line loopback 3.3 - loop 3 channel 1 send data transitions 3.2 - loop 3 channel 1 receive data transitions 3.1 - loop 3 channel 2 send data transitions 3.0 - loop 3 channel 2 receive data transitionsro
OCTET STRING
.1.3.6.1.4.1.498.10.8.1.2
bqlDC610Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9
bqlDC610AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9.1
bqlDC610PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9.1.1
bqlDC610Chnl1DTRAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9.1.2
bqlDC610NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9.1.3
bqlDC610DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.9.1.4
bqlDC610LEDStatusTableThe GDC DC610 LED Status Table.
SEQUENCE OF BqlDC610LEDEntry
.1.3.6.1.4.1.498.10.10
bqlDC610LEDEntryAn entry in the GDC DC610 LED Status table.
BqlDC610LEDEntry
.1.3.6.1.4.1.498.10.10.1
bqlDC610LEDIndexThis object is the index of the DC610 LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.10.1.1
bqlDC610LEDStatusThe GDC DC610 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - sync 1.4 - request to send 1.3 - clear to send 1.2 - carrier on 1.1 - send data transitions 1.0 - receive data transitionsro
OCTET STRING
.1.3.6.1.4.1.498.10.10.1.2
bqlDC612Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11
bqlDC612AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1
bqlDC612PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1.1
bqlDC612Chnl1DTRAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1.2
bqlDC612Chnl2DTRAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1.3
bqlDC612NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1.4
bqlDC612DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.11.1.5
bqlDC612LEDStatusTableThe GDC DC612 LED Status Table.
SEQUENCE OF BqlDC612LEDEntry
.1.3.6.1.4.1.498.10.12
bqlDC612LEDEntryAn entry in the GDC DC612 LED Status table.
BqlDC612LEDEntry
.1.3.6.1.4.1.498.10.12.1
bqlDC612LEDIndexThis object is the index of the DC612 LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.12.1.1
bqlDC612LEDStatusThe GDC DC612 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - not used 1.4 - not used 1.3 - not used 1.2 - not used 1.1 - channel 1 selected for front panel pushbutton operation 1.0 - channel 2 selected for front panel pushbutton operation 2.7 - not used 2.6 - channel 1 test mode 2.5 - channel 1 sync 2.4 - channel 1 request to send 2.3 - channel 1 clear to send 2.2 - channel 1 carrier on 2.1 - channel 1 send data transitions 2.0 - channel 1 receive data transitions 3.7 - not used 3.6 - channel 2 test mode 3.5 - channel 2 sync 3.4 - channel 2 request to send 3.3 - channel 2 clear to send 3.2 - channel 2 carrier on 3.1 - channel 2 send data transitions 3.0 - channel 2 receive data transitionscdro
OCTET STRING
.1.3.6.1.4.1.498.10.12.1.2
bqlControlTableThe GDC SC616 Control Table.
SEQUENCE OF BqlControlEntry
.1.3.6.1.4.1.498.10.13
bqlControlEntryAn entry in the GDC SC616 Control table.
BqlControlEntry
.1.3.6.1.4.1.498.10.13.1
bqlControlIndexThis object is the identifier of the SC616 Control table.ro
SCinstance
.1.3.6.1.4.1.498.10.13.1.1
bqlSoftResetForces a soft reset on the network element. The reset selection is write only. The normal selection is read only.rw
Enumeration
.1.3.6.1.4.1.498.10.13.1.2
bqlEraseConfigForces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only.rw
Enumeration
.1.3.6.1.4.1.498.10.13.1.3
bqlCurrentTableThe SC616 Current table.
SEQUENCE OF BqlCurrentEntry
.1.3.6.1.4.1.498.10.14
bqlCurrentEntryAn entry in the SC616 Current table.
BqlCurrentEntry
.1.3.6.1.4.1.498.10.14.1
bqlCurrentIndexThe index value which uniquely identifies the SC616 DC610 or DC612 interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.10.14.1.1
bqlCurrentESsThe number of Errored Seconds, encountered by an ISDN interface in the current 15 minute interval. This is defined as a second with at least one CRC error event or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.14.1.2
bqlCurrentBESsThe number of Bursty Errored Seconds (BESs) encountered by an ISDN interface in the current 15 minute interval. This is defined as a second with more than one but less than 640 CRC error events.ro
Gauge
.1.3.6.1.4.1.498.10.14.1.3
bqlCurrentSESsThe number of Severely Errored Seconds encoun- tered by an ISDN interface in the current 15 minute interval. This is defined as a second with 640 or more CRC error events or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.14.1.4
bqlCurrentUASsThe number of Unavailable Seconds encountered by an ISDN interface in the current 15 minute interval. This is a count of one-second intervals during which service is not available.ro
Gauge
.1.3.6.1.4.1.498.10.14.1.5
bqlCurrentStatsThe number of ES, BES, ESE and UAS encountered by an ISDN interface in the current 15 minute interval. This is a count of one-second intervals during which service is not available.ro
OCTET STRING
.1.3.6.1.4.1.498.10.14.1.6
bqlIntervalTableThe SC616 Interval table.
SEQUENCE OF BqlIntervalEntry
.1.3.6.1.4.1.498.10.15
bqlIntervalEntryAn entry in the SC616 Interval table.
BqlIntervalEntry
.1.3.6.1.4.1.498.10.15.1
bqlIntervalIndexThe index value which uniquely identifies the ISDN interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.10.15.1.1
bqlIntervalNumberA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that all 96 intervals are valid).ro
INTEGER
.1.3.6.1.4.1.498.10.15.1.2
bqlIntervalESsThe number of Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals. This is defined as a second with at least one CRC error event or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.15.1.3
bqlIntervalBESsThe number of Bursty Errored Seconds (BESs) encountered by an ISDN interface in one of the previous 96, individual 15 minute, intervals. This is defined as a second with more than one but less than 640 CRC error events.ro
Gauge
.1.3.6.1.4.1.498.10.15.1.4
bqlIntervalSESsThe number of Severely Errored Seconds encoun- tered by an ISDN interface in one of the previous 96, individual 15 minute, intervals. This is defined as a second with 640 or more CRC error events or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.15.1.5
bqlIntervalUASsThe number of Unavailable Seconds encountered by an ISDN interface in one of the previous 96, individual 15 minute, intervals. This is a count of one-second intervals during which service is not available.ro
Gauge
.1.3.6.1.4.1.498.10.15.1.6
bqlIntervalStatsThe number of ES, BES, SES, and UAS encountered by an ISDN interface in one of the previous 96, individual 15 minute, intervals. This is a count of one-second intervals during which service is not available.ro
OCTET STRING
.1.3.6.1.4.1.498.10.15.1.7
bqlTotalTableThe SC616 Total table. 24 hour interval.
SEQUENCE OF BqlTotalEntry
.1.3.6.1.4.1.498.10.16
bqlTotalEntryAn entry in the SC616 Total table.
BqlTotalEntry
.1.3.6.1.4.1.498.10.16.1
bqlTotalIndexThe index value which uniquely identifies the ISDN interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.10.16.1.1
bqlTotalESsThe number of Errored Seconds encountered by an ISDN interface in the previous 24 hour interval. This is defined as a second with at least one CRC error event or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.16.1.2
bqlTotalBESsThe number of Bursty Errored Seconds (BESs) encountered by an ISDN interface in the previous 24 hour interval. This is defined as a second with more than one but less than 640 CRC error events.ro
Gauge
.1.3.6.1.4.1.498.10.16.1.3
bqlTotalSESsThe number of Severely Errored Seconds encoun- tered by an ISDN interface in the previous 24 hour interval. This is defined as a second with 640 or more CRC error events or one or more out of frames (OOF).ro
Gauge
.1.3.6.1.4.1.498.10.16.1.4
bqlTotalUASsThe number of Unavailable Seconds encountered by an ISDN interface in the previous 24 hour interval. This is a count of one-second intervals during which service is not available.ro
Gauge
.1.3.6.1.4.1.498.10.16.1.5
bqlTotalStatsThe number of ES, BES, SES and UAS encountered by an ISDN interface in the previous 24 hour interval. This is a count of one-second intervals during which service is not available.ro
OCTET STRING
.1.3.6.1.4.1.498.10.16.1.6
bqlDTERateTableThe DC610 DC612 DTE rate table.
SEQUENCE OF BqlDTEEntry
.1.3.6.1.4.1.498.10.17
bqlDTEEntryAn entry in the DC610 DC612 table.
BqlDTEEntry
.1.3.6.1.4.1.498.10.17.1
bqlDTEIndexThe index value which uniquely identifies the DC610 DC612 interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.10.17.1.1
bqlDTE2MappedForces a DC612 to map DTE channel 2 into channel 2 or channel 1.rw
Enumeration
.1.3.6.1.4.1.498.10.17.1.2
bqlDTE2DataRateForces a DC612 DTE channel 2 to a K bit per second rate.rw
Enumeration
.1.3.6.1.4.1.498.10.17.1.3
bqlDTE1MappedForces a DC610 or DC612 to map DTE channel 1 into channel 1 or channel 2.rw
Enumeration
.1.3.6.1.4.1.498.10.17.1.4
bqlDTE1DataRateForces a DC610 or DC612 DTE channel 1 to a K bit per second rate.rw
Enumeration
.1.3.6.1.4.1.498.10.17.1.5
bqlIntervalMaintenanceTableThe SC616, DC610, DC612 Loop Interval Maintenance table.
SEQUENCE OF BqlIntervalMaintenanceEntry
.1.3.6.1.4.1.498.10.18
bqlIntervalMaintenanceEntryThe SC616, DC610, DC612 Interval Maintenance table entry.
BqlIntervalMaintenanceEntry
.1.3.6.1.4.1.498.10.18.1
bqlIntervalMaintenanceIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface.ro
SCinstance
.1.3.6.1.4.1.498.10.18.1.1
bqlResetIntervalsThis variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.rw
Enumeration
.1.3.6.1.4.1.498.10.18.1.2
bqlNumberofValidIntervalsThis variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.ro
INTEGER
.1.3.6.1.4.1.498.10.18.1.3
bqlDC610LEDStatusNZTableThe GDC DC610NZ LED Status Table.
SEQUENCE OF BqlDC610LEDNZEntry
.1.3.6.1.4.1.498.10.19
bqlDC610LEDNZEntryAn entry in the GDC DC610NZ LED Status table.
BqlDC610LEDNZEntry
.1.3.6.1.4.1.498.10.19.1
bqlDC610LEDNZIndexThis object is the index of the DC610 LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.19.1.1
bqlDC610LEDNZStatusThe GDC DC610NZ front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - 128K (sync ) 1.4 - request to send 1.3 - clear to send 1.2 - network available (carrier on) 1.1 - send data transitions 1.0 - receive data transitionsro
OCTET STRING
.1.3.6.1.4.1.498.10.19.1.2
bqlGT128Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20
bqlGT128AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20.1
bqlGT128NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20.1.1
bqlGT128DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20.1.2
bqlGT128PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20.1.3
bqlGT128Chnl1DTRAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.20.1.4
bqlGT128LEDStatusTableThe GDC GT 128 LED Status Table.
SEQUENCE OF BqlGT128LEDEntry
.1.3.6.1.4.1.498.10.21
bqlGT128LEDEntryAn entry in the GDC GT128 LED Status table.
BqlGT128LEDEntry
.1.3.6.1.4.1.498.10.21.1
bqlGT128LEDIndexThis object is the index of the GT 128 LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.21.1.1
bqlGT128LEDStatusThe GDC GT128 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - sync 1.4 - request to send 1.3 - clear to send 1.2 - carrier on 1.1 - send data transitions 1.0 - receive data transitions 2.6 - fu 2.5 - fu 2.4 - fu 2.3 - fu 2.2 - remote loopback ON 2.1 - selftest ON 2.0 - line loopback ONro
OCTET STRING
.1.3.6.1.4.1.498.10.21.1.2
bqlGT128NZAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22
bqlGT128NZAlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22.1
bqlGT128NZNoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22.1.1
bqlGT128NZDiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22.1.2
bqlGT128NZPowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22.1.3
bqlGT128NZChnl1DTRAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.10.22.1.4
bqlGT128LEDNZStatusTableThe GDC GT 128 NZ LED Status Table.
SEQUENCE OF BqlGT128LEDNZEntry
.1.3.6.1.4.1.498.10.23
bqlGT128LEDNZEntryAn entry in the GDC GT128 NZ LED Status table.
BqlGT128LEDNZEntry
.1.3.6.1.4.1.498.10.23.1
bqlGT128LEDNZIndexThis object is the index of the GT 128 NZ LED Status table.ro
SCinstance
.1.3.6.1.4.1.498.10.23.1.1
bqlGT128LEDNZStatusThe GDC GT128 NZ front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - 128K (sync) 1.4 - request to send 1.3 - clear to send 1.2 - network available (carrier on) 1.1 - send data transitions 1.0 - receive data transitions 2.6 - fu 2.5 - fu 2.4 - fu 2.3 - fu 2.2 - remote loopback ON 2.1 - selftest ON 2.0 - line loopback ONro
OCTET STRING
.1.3.6.1.4.1.498.10.23.1.2
GDCSC616-MIB - SNMP MIB Reference | MIBs Explorer