GDCSC613-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
68
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
68 total| Object Name |
|---|
gdc OBJECT IDENTIFIER .1.3.6.1.4.1.498 |
RFC1213-MIB Unknown .1.3.6.1.4.1.498 |
bql2 OBJECT IDENTIFIER .1.3.6.1.4.1.498.12 |
bql613 OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.1 |
bql613MIBVersionThe version number of the MIB, to allow products to
know which MIB is being supported. The version number
will be x.yzT where x is a major revision (1-9), y is a minor
revision(0-9), z is a typo revision (0-9) and T indicates the
MIB is still a test revision(A-Z). When a release is complete
no T should exist.ro DisplayString .1.3.6.1.4.1.498.12.1.1 |
bql613WhatAreYouTableThe GDC SC613 What Are You Table. SEQUENCE OF Bql613WhatAreYouEntry .1.3.6.1.4.1.498.12.1.2 |
bql613WhatAreYouEntryAn entry in the GDC SC613 What Are You table. Bql613WhatAreYouEntry .1.3.6.1.4.1.498.12.1.2.1 |
bql613WhatAreYouIndexThis object is the identifier of the SC613 What Are You table.ro SCinstance .1.3.6.1.4.1.498.12.1.2.1.1 |
bql613CodeRevThis function returns the firmware code level.
Example A- ,B-ro DisplayString .1.3.6.1.4.1.498.12.1.2.1.2 |
bql613AlarmStatusThe current alarms of the unit without the alarm masks.ro OCTET STRING .1.3.6.1.4.1.498.12.1.2.1.3 |
bql613ConfigTableThe GDC SC613. SEQUENCE OF Bql613ConfigEntry .1.3.6.1.4.1.498.12.1.3 |
bql613ConfigEntryA listing of GDC 2B1Q SC613 options. Bql613ConfigEntry .1.3.6.1.4.1.498.12.1.3.1 |
bql613ConfigIndexA unique index for the Configuration Table.ro SCinstance .1.3.6.1.4.1.498.12.1.3.1.1 |
bql613TestPatternObject to select loop and channel test pattern
for SC613.rw Enumeration .1.3.6.1.4.1.498.12.1.3.1.2 |
bql613RLTimeoutObject to select remote loop time out.rw Enumeration .1.3.6.1.4.1.498.12.1.3.1.3 |
bql613MasterTXClkSrcObject to option the Loop master transmit clock source.rw Enumeration .1.3.6.1.4.1.498.12.1.3.1.4 |
bql613DTEDataRateObject to option a SC613 Loop interface to a K bit per second rate.rw Enumeration .1.3.6.1.4.1.498.12.1.3.1.5 |
bql613RespRdlObject to option V54 Response RDL to enable or disable.rw Enumeration .1.3.6.1.4.1.498.12.1.3.1.6 |
bql613DiagnosticTableThe GDC SC613 diagnostics table. SEQUENCE OF Bql613DiagnosticEntry .1.3.6.1.4.1.498.12.1.4 |
bql613DiagnosticEntryA listing of GDC SC613 diagnostic tests Bql613DiagnosticEntry .1.3.6.1.4.1.498.12.1.4.1 |
bql613DiagnosticIndexA unique index for the Diagnostic Table.ro SCinstance .1.3.6.1.4.1.498.12.1.4.1.1 |
bql613DiagnosticTestThis function selects or reads the test.
0 = no test currently operating
1 = remote loopback test
2 = channel loopback test
4 = data loopback test
8 = selftest
16 = line loopback test
32 = terminate test
All other values are test combinations such as
9 = selftest and remote loopback.rw INTEGER .1.3.6.1.4.1.498.12.1.4.1.2 |
bql613DiagnosticActiveThis function represents the test condition.ro Enumeration .1.3.6.1.4.1.498.12.1.4.1.3 |
bql613DiagnosticResultsThis function reads the self test results in
bit errors.ro INTEGER .1.3.6.1.4.1.498.12.1.4.1.4 |
bql613DiagnosticErrorCountThis function resets the selftest error count for a
SC613.rw Enumeration .1.3.6.1.4.1.498.12.1.4.1.5 |
bql613ControlTableThe GDC SC613 Control Table. SEQUENCE OF Bql613ControlEntry .1.3.6.1.4.1.498.12.1.6 |
bql613ControlEntryAn entry in the GDC SC613 Control table. Bql613ControlEntry .1.3.6.1.4.1.498.12.1.6.1 |
bql613ControlIndexThis object is the identifier of the SC613 Control table.ro SCinstance .1.3.6.1.4.1.498.12.1.6.1.1 |
bql613SoftResetForces a soft reset on the network element.
The reset selection is write only. The normal
selection is read only.rw Enumeration .1.3.6.1.4.1.498.12.1.6.1.2 |
bql613EraseConfigForces an erase of the stored configuration in the
network element. The erase selection is write only.
The normal selection is read only.rw Enumeration .1.3.6.1.4.1.498.12.1.6.1.3 |
bql613FrontPanelObject used to enable or disable the units front panel
switches.rw Enumeration .1.3.6.1.4.1.498.12.1.6.1.4 |
bql613LEDStatusThe GDC SC613 front panel LED Status.
A value of 1 means on, 0 is off.
byte 1 bit 7 (1.7) - not used
1.6 - test mode
1.5 - alarm on
1.4 - loop 1 line loopback
1.3 - loop 1 send data transitions
1.2 - loop 1 receive data transitions
1.1 - loop 1 request to send
1.0 - loop 1 data carrier on
2.7 - not used
2.6 - not used
2.5 - not used
2.4 - loop 2 line loopback
2.3 - loop 2 send data transitions
2.2 - loop 2 receive data transitions
2.1 - loop 2 request to send
2.0 - loop 2 data carrier on
3.7 - not used
3.6 - not used
3.5 - not used
3.4 - loop 3 line loopback
3.3 - loop 3 send data transitions
3.2 - loop 3 receive data transitions
3.1 - loop 3 request to send
3.0 - loop 3 data carrier onro OCTET STRING .1.3.6.1.4.1.498.12.1.6.1.5 |
bql613CurrentTableThe SC613 Current table. SEQUENCE OF Bql613CurrentEntry .1.3.6.1.4.1.498.12.1.7 |
bql613CurrentEntryAn entry in the SC613 Current table. Bql613CurrentEntry .1.3.6.1.4.1.498.12.1.7.1 |
bql613CurrentIndexThe index value which uniquely identifies the
SC613 interface to which this entry
is applicable.ro SCinstance .1.3.6.1.4.1.498.12.1.7.1.1 |
bql613CurrentStatsThe number of Errored Seconds, Severely Errored Seconds &
Unavailable Errored Seconds encountered by
an ISDN interface in the current 15 minute interval.ro OCTET STRING .1.3.6.1.4.1.498.12.1.7.1.2 |
bql613IntervalTableThe SC613 Interval table. SEQUENCE OF Bql613IntervalEntry .1.3.6.1.4.1.498.12.1.8 |
bql613IntervalEntryAn entry in the SC613 Interval table. Bql613IntervalEntry .1.3.6.1.4.1.498.12.1.8.1 |
bql613IntervalIndexThe index value which uniquely identifies the
ISDN interface to which this entry is applicable.ro SCinstance .1.3.6.1.4.1.498.12.1.8.1.1 |
bql613IntervalNumberA number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minute inter-
val (assuming that all 96 intervals are
valid).ro INTEGER .1.3.6.1.4.1.498.12.1.8.1.2 |
bql613IntervalStatsThe number of Errored Seconds, Severely Errored Seconds and
Unavailable Errored Seconds encountered by a DS1 interface in one of the
previous 96, individual 15 minute, intervals.ro OCTET STRING .1.3.6.1.4.1.498.12.1.8.1.3 |
bql613TotalTableThe SC613 Total table. 24 hour interval. SEQUENCE OF Bql613TotalEntry .1.3.6.1.4.1.498.12.1.9 |
bql613TotalEntryAn entry in the SC613 Total table. Bql613TotalEntry .1.3.6.1.4.1.498.12.1.9.1 |
bql613TotalIndexThe index value which uniquely identifies the
ISDN interface to which this entry is applicable.ro SCinstance .1.3.6.1.4.1.498.12.1.9.1.1 |
bql613TotalStatsThe number of Errored Seconds,Severely Errored Seconds & Unavailable Errored
Seconds encountered by an ISDN interface in the previous 24 hour interval.ro OCTET STRING .1.3.6.1.4.1.498.12.1.9.1.2 |
bql613IntervalMaintenanceTableThe SC613 Loop Interval Maintenance table. SEQUENCE OF Bql613IntervalMaintenanceEntry .1.3.6.1.4.1.498.12.1.10 |
bql613IntervalMaintenanceEntryThe SC613 Interval Maintenance table entry. Bql613IntervalMaintenanceEntry .1.3.6.1.4.1.498.12.1.10.1 |
bql613IntervalMaintenanceIndexThe index value which uniquely identifies the interface to
which this entry is applicable. This has the form of a
SCinstance which defines the slot, line, drop, and interface,
where is can be 1, 2, or 3.ro SCinstance .1.3.6.1.4.1.498.12.1.10.1.1 |
bql613ResetIntervalsThis variable is used to reset Loop performance intervals.
When it is set to reset, the Loop performance tables are
reset to zero.rw Enumeration .1.3.6.1.4.1.498.12.1.10.1.2 |
bql613NumberofValidIntervalsThis variable is used to read the number of intervals collected.
Each interval is an increment of 15 minutes.ro INTEGER .1.3.6.1.4.1.498.12.1.10.1.3 |
bql613ResetMajorAlarmThis variable is used to reset alarm per Loop basis.rw Enumeration .1.3.6.1.4.1.498.12.1.10.1.4 |
bql613ResetMinorAlarmThis variable is used to reset alarm per Loop basis.rw Enumeration .1.3.6.1.4.1.498.12.1.10.1.5 |
bql613Alarm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7 |
bql613AlarmData OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1 |
bql613NoResponseAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.1 |
bql613DiagRxErrAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.2 |
bql613PowerUpAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.3 |
bql613Lp2B1QOutofSyncAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.4 |
bql613LpTxClockOutOfTolerance OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.5 |
bql613LpExtTxClkAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.6 |
bql613LpSealingCurrentNoContinuityAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.7 |
bql613LpMajorBERAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.8 |
bql613LpMinorBERAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.1.9 |
bql613AlarmConfigTableThe bql613AlarmConfigTable contains entries that configure alarm
reporting. The structure of the table is such that alarm
configuration is supported on a unit and interface basis, and
then on an alarm type basis within the interface. For
simplicity sake alarms, be they unit or interface
related, are represented in one table. SEQUENCE OF Bql613AlarmConfigEntry .1.3.6.1.4.1.498.12.7.2 |
bql613AlarmConfigEntryAn entry in the bql613AlarmConfigTable table. Bql613AlarmConfigEntry .1.3.6.1.4.1.498.12.7.2.1 |
bql613AlarmConfigIndexThe index value which uniquely identifies the interface to
which this entry is applicable.ro SCinstance .1.3.6.1.4.1.498.12.7.2.1.1 |
bql613AlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type.
The format of this identifier is an OBJECT IDENTIFIER that has
the following format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y)
where xxx(x) is the administratively assigned family object
identifier (z) is the object identifier for alarms in the family
defined MIB and yyy(y) is the administratively assigned alarm
type identifier for this alarm.ro OBJECT IDENTIFIER .1.3.6.1.4.1.498.12.7.2.1.2 |
bql613AlarmThresholdThis function sets/reads the Major or Minor BER alarm threshold criteria.rw Enumeration .1.3.6.1.4.1.498.12.7.2.1.3 |