Home/Catalog/GDCSC611-MIB

GDCSC611-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for GDCSC611-MIB.

90
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

90 total
Object Name
gdc
OBJECT IDENTIFIER
.1.3.6.1.4.1.498
RFC1213-MIB
Unknown
.1.3.6.1.4.1.498
bql2
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12
bql611
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.2
bql611MIBVersionThe version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.ro
DisplayString
.1.3.6.1.4.1.498.12.2.1
bql611WhatAreYouTableThe GDC SC611 and DC621 What Are You Table.
SEQUENCE OF Bql611WhatAreYouEntry
.1.3.6.1.4.1.498.12.2.2
bql611WhatAreYouEntryAn entry in the GDC SC611 What Are You table.
Bql611WhatAreYouEntry
.1.3.6.1.4.1.498.12.2.2.1
bql611WhatAreYouIndexThis object is the identifier of the SC611/DC621 What Are You table.ro
SCinstance
.1.3.6.1.4.1.498.12.2.2.1.1
bql611BaseCardTypeThis function returns the value the Base Card Type.ro
Enumeration
.1.3.6.1.4.1.498.12.2.2.1.2
bql611OptionCardThis indicates whether the option card is installed or not on the DC621.ro
Enumeration
.1.3.6.1.4.1.498.12.2.2.1.3
bql611DTECardTypeThis object is the DTE plug-in card type. This variable is used for a SC611 or DC621.ro
Enumeration
.1.3.6.1.4.1.498.12.2.2.1.4
bql611CodeRevThis function returns the firmware code level. Example A- ,B-ro
DisplayString
.1.3.6.1.4.1.498.12.2.2.1.5
bql611AlarmStatusThe current alarms of the unit without the alarm masks.ro
OCTET STRING
.1.3.6.1.4.1.498.12.2.2.1.6
bql611ConfigTableThe GDC SC611, DC621 2B1Q configuration table.
SEQUENCE OF Bql611ConfigEntry
.1.3.6.1.4.1.498.12.2.3
bql611ConfigEntryA listing of GDC 2B1Q SC611/DC621 options.
Bql611ConfigEntry
.1.3.6.1.4.1.498.12.2.3.1
bql611ConfigIndexA unique index for the Configuration Table.ro
SCinstance
.1.3.6.1.4.1.498.12.2.3.1.1
bql611DteRateObject to select the DTE rate for the SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.2
bql611RateAdaptionObject to select the DTE Rate Adaption for the SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.3
bql611DteOperationObject to select the DTE Operation for the SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.4
bql611TxClkSourceObject to select the Transmit Clock Source for the SC611 ONLY.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.5
bql611WordLengthObject to select the Word Length for the SC611 or DC621 when selected for async mode.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.6
bql611OverSpeedObject to select the Over Speed for the SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.7
bql611RTSObject to select RTS for SC611 and DC621 only.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.8
bql611RTSCTSDelayObject to select RTS CTS Delay for SC611 and DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.9
bql611DCDObject to select DCD for SC611 and DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.10
bql611RDLObject to select the RDL respond for SC611 and DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.11
bql611RDLMethodObject to select RDL Method for SC611 and DC621. SC611 Valid Choices DC621 Valid Choices =================== =================== V54 V54 EOC PN127rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.12
bql611RDLTimeoutObject to select RDL Timeout for SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.13
bql611TestPatternObject to Test Pattern for SC611 and DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.3.1.14
bql611DiagnosticTableThe GDC SC611/DC621 diagnostics table.
SEQUENCE OF Bql611DiagnosticEntry
.1.3.6.1.4.1.498.12.2.4
bql611DiagnosticEntryA listing of GDC SC611/DC621 diagnostic tests
Bql611DiagnosticEntry
.1.3.6.1.4.1.498.12.2.4.1
bql611DiagnosticIndexA unique index for the Diagnostic Table.ro
SCinstance
.1.3.6.1.4.1.498.12.2.4.1.1
bql611DiagnosticTestThis function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest 16 = line loopback test 32 = terminate test All other values are test combinations such as 9 = selftest and remote loopback.rw
INTEGER
.1.3.6.1.4.1.498.12.2.4.1.2
bql611DiagnosticActiveThis function represents the test condition.ro
Enumeration
.1.3.6.1.4.1.498.12.2.4.1.3
bql611DiagnosticResultsThis function reads the self test results in bit errors.ro
INTEGER
.1.3.6.1.4.1.498.12.2.4.1.4
bql611DiagnosticResetErrorCountObject to reset selftest error count during diagnostic self testing for SC611 and DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.2.4.1.5
bql611ControlTableThe GDC SC611 and DC621 Control Table.
SEQUENCE OF Bql611ControlEntry
.1.3.6.1.4.1.498.12.2.5
bql611ControlEntryAn entry in the GDC SC611/DC621 Control table.
Bql611ControlEntry
.1.3.6.1.4.1.498.12.2.5.1
bql611ControlIndexThis object is the identifier of the SC611/DC621 Control table.ro
SCinstance
.1.3.6.1.4.1.498.12.2.5.1.1
bql611SoftResetForces a soft reset on the network element. The reset selection is write only. The normal selection is read only.rw
Enumeration
.1.3.6.1.4.1.498.12.2.5.1.2
bql611EraseConfigForces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only.rw
Enumeration
.1.3.6.1.4.1.498.12.2.5.1.3
bql611FrontPanelObject used to enable or disable the units front panel switches.rw
Enumeration
.1.3.6.1.4.1.498.12.2.5.1.4
bql611LEDStatusThe GDC SC611 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - not used 1.4 - test mode 1.3 - alarm transitions 1.2 - self test 1.1 - line loopback 1.0 - remote loopback 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - not used 2.3 - send data transitions 2.2 - receive data transitions 2.1 - request to send 2.0 - data carrier detect 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - not used 3.3 - not used 3.2 - not used 3.1 - not used 3.0 - not usedro
OCTET STRING
.1.3.6.1.4.1.498.12.2.5.1.5
bql621LEDStatusThe GDC DC621 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - sync 1.4 - request to send 1.3 - clear to send 1.2 - carrier 1.1 - send data transitions 1.0 - receive data transitions 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - not used 2.3 - not used 2.2 - not used 2.1 - not used 2.0 - not used 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - not used 3.3 - not used 3.2 - not used 3.1 - not used 3.0 - not usedro
OCTET STRING
.1.3.6.1.4.1.498.12.2.5.1.6
bql611CurrentTableThe SC611/DC621 Current table.
SEQUENCE OF Bql611CurrentEntry
.1.3.6.1.4.1.498.12.2.6
bql611CurrentEntryAn entry in the SC611/DC621 Current table.
Bql611CurrentEntry
.1.3.6.1.4.1.498.12.2.6.1
bql611CurrentIndexThe index value which uniquely identifies the SC611 interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.2.6.1.1
bql611CurrentStatsThe number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval.ro
OCTET STRING
.1.3.6.1.4.1.498.12.2.6.1.2
bql611IntervalTableThe SC611/DC621 Interval table.
SEQUENCE OF Bql611IntervalEntry
.1.3.6.1.4.1.498.12.2.8
bql611IntervalEntryAn entry in the SC611/DC621 Interval table.
Bql611IntervalEntry
.1.3.6.1.4.1.498.12.2.8.1
bql611IntervalIndexThe index value which uniquely identifies the ISDN interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.2.8.1.1
bql611IntervalNumberA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that all 96 intervals are valid).ro
INTEGER
.1.3.6.1.4.1.498.12.2.8.1.2
bql611IntervalStatsThe number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.ro
OCTET STRING
.1.3.6.1.4.1.498.12.2.8.1.3
bql611TotalTableThe SC611/DC621 Total table. 24 hour interval.
SEQUENCE OF Bql611TotalEntry
.1.3.6.1.4.1.498.12.2.9
bql611TotalEntryAn entry in the SC611/DC621 Total table.
Bql611TotalEntry
.1.3.6.1.4.1.498.12.2.9.1
bql611TotalIndexThe index value which uniquely identifies the ISDN interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.2.9.1.1
bql611TotalStatsThe number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval.ro
OCTET STRING
.1.3.6.1.4.1.498.12.2.9.1.2
bql611IntervalMaintenanceTableThe SC611, DC621 Loop Interval Maintenance table.
SEQUENCE OF Bql611IntervalMaintenanceEntry
.1.3.6.1.4.1.498.12.2.10
bql611IntervalMaintenanceEntryThe SC611, DC621 Interval Maintenance table entry.
Bql611IntervalMaintenanceEntry
.1.3.6.1.4.1.498.12.2.10.1
bql611IntervalMaintenanceIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface.ro
SCinstance
.1.3.6.1.4.1.498.12.2.10.1.1
bql611ResetIntervalsThis variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.rw
Enumeration
.1.3.6.1.4.1.498.12.2.10.1.2
bql611NumberofValidIntervalsThis variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.ro
INTEGER
.1.3.6.1.4.1.498.12.2.10.1.3
bql611ResetMajorAlarmThis variable is used to reset alarm per Loop basis.rw
Enumeration
.1.3.6.1.4.1.498.12.2.10.1.4
bql611ResetMinorAlarmThis variable is used to reset alarm per Loop basis.rw
Enumeration
.1.3.6.1.4.1.498.12.2.10.1.5
bql621
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.3
bql611Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9
bql611AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1
bql611NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.1
bql611DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.2
bql611PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.3
bql611OutofSyncAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.4
bql611TxClkOutOfToleranceAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.5
bql611ExtClkAbsentAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.6
bql611SealingCurrentNoContinuityAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.7
bql611DtrNotPresentAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.8
bql611MajorAlarmBERAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.9
bql611MinorAlarmBERAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.1.10
bql611AlarmConfigTableThe bql611AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
SEQUENCE OF Bql611AlarmConfigEntry
.1.3.6.1.4.1.498.12.9.2
bql611AlarmConfigEntryAn entry in the bql611AlarmConfigTable table.
Bql611AlarmConfigEntry
.1.3.6.1.4.1.498.12.9.2.1
bql611AlarmConfigIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.9.2.1.1
bql611AlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.9.2.1.2
bql611AlarmThresholdThis function sets/reads the Major or Minor BER alarm threshold criteria for a SC611 or DC621.rw
Enumeration
.1.3.6.1.4.1.498.12.9.2.1.3
bql621Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11
bql621AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1
bql621NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.1
bql621DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.2
bql621PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.3
bql621DtrNotPresentAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.4
bql621MajorAlarmBERAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.5
bql621MinorAlarmBERAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.11.1.6
GDCSC611-MIB - SNMP MIB Reference | MIBs Explorer