GDCMP7001-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
147
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
147 total| Object Name |
|---|
gdc OBJECT IDENTIFIER .1.3.6.1.4.1.498 |
RFC1155-SMI Unknown .1.3.6.1.4.1.498 |
dsx1 OBJECT IDENTIFIER .1.3.6.1.4.1.498.6 |
mp7001System OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10 |
mp7001Version OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.1 |
mp7001MIBversionIdentifies the version of the MIB. The format of the version
is x.yzT, where 'x' identifies the major revision number, 'y'
identifies the minor revision number, 'z' identifies the
typographical revision, and T identifies the test revision.
Acceptable values for the individual revision components are
as follows:
x: 1 - 9
y: 0 - 9
z: 0 - 9
T: A - Z
Upon formal release, no designation for the test revision will
be present.ro Unknown .1.3.6.1.4.1.498.6.10.1.1 |
mp7001VersionTable SEQUENCE OF Mp7001VersionEntry .1.3.6.1.4.1.498.6.10.1.2 |
mp7001VersionEntryAn entry in the GDC Mp7001System Version Table. Mp7001VersionEntry .1.3.6.1.4.1.498.6.10.1.2.1 |
mp7001VersionIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.1.2.1.1 |
mp7001FirmwareRevThe version number of the firmware, to allow products
to know which revision is installed. The released
version number is sequenced from
::= { mp7001VersionEntry 2 }
mp7001CardType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTIONro DisplayString .1.3.6.1.4.1.498.6.10.1.2.1.4 |
mp7001Maintenance OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.2 |
mp7001MaintenanceTableThe table describes the maintenance objects for MP 7001. SEQUENCE OF Mp7001MaintenanceEntry .1.3.6.1.4.1.498.6.10.2.1 |
mp7001MaintenanceEntryAn entry in the GDC 701 Maintenance Table. Mp7001MaintenanceEntry .1.3.6.1.4.1.498.6.10.2.1.1 |
mp7001MaintenanceLineIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.2.1.1.1 |
mp7001SoftResetSupports the action of soft resetting the unit. When this
object is set to reset(2), then the unit performs a soft
reset, whose meaning is specific to the type of unit being
managed. The value of norm(1) will be returned when
the reset is complete.
The value of norm(1) can not be set by management.rw Enumeration .1.3.6.1.4.1.498.6.10.2.1.1.2 |
mp7001SysUpTimeThis variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.ro INTEGER .1.3.6.1.4.1.498.6.10.2.1.1.3 |
mp7001DefaultInitThis is used to allow the NonVolatile Configuration to
be set to a factory default state. When this value is set to
factoryDefault(2) the unit will perform a reset to make
the default configuration take affect.
The value of normal(1) will be returned when the initialization
is complete.
The value of normal(1) can not be set by management.rw Enumeration .1.3.6.1.4.1.498.6.10.2.1.1.4 |
mp7001ResetStatsSupports the action of soft resetting the mp7001ValidIntervals
object. When this object is set to reset(2), then the unit
will reset the mp7001ValidIntervals object to zero.
The value of norm(1) can not be set by management.rw Enumeration .1.3.6.1.4.1.498.6.10.2.1.1.5 |
mp7001LedStatusReturns a bitwise snapshot of the front panel LED state.
Octet 1 bit 7 - not used
bit 6 - ON
bit 5 - INSV
bit 4 - RSP
bit 3 - TMG
bit 2 - future use
bit 1 - future use
bit 0 - future use
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - NTWK AIS
bit 4 - NTWK LCV
bit 3 - NTWK LOS
bit 2 - NTWK OOF
bit 1 - ALM
bit 0 - TMro OCTET STRING .1.3.6.1.4.1.498.6.10.2.1.1.6 |
mp7001T1CircuitNameCircuit name T1 is connected to.rw DisplayString .1.3.6.1.4.1.498.6.10.2.1.1.7 |
mp7001SetRealTimeNumber of seconds from midnight Dec 31, 1969.rw INTEGER .1.3.6.1.4.1.498.6.10.2.1.1.8 |
mp7001AlarmStatusReturns a bit-wise Status of alarms
Octet 1 bit 7 - not used
bit 6 - NTWK LOS
bit 5 - NTWK LOF
bit 4 - NWTK_AIS
bit 3 - future use
bit 2 - NTWK Received YELLOW
bit 1 - NTWK Excessive Zeros - not supported
bit 0 - NTWK Low Average Density - not supported
Octet 2 bit 7 - not used
bit 6 - NTWK BiPolar Violations
bit 5 - NTWK CRC Errors
bit 4 - NTWK Controlled Slips
bit 3 - Unavailable Signal State
bit 2 - Status Change
bit 1 - Timing Loss
bit 0 - Unit Failure
Octet 3 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - future use
Octet 4 bit 7 - not used
bit 6 - ES
bit 5 - BES
bit 4 - SES
bit 3 - UAS
bit 2 - Unsolicited Test
bit 1 - NVRAM checksum corrupted
bit 0 - Power-up Alarmro OCTET STRING .1.3.6.1.4.1.498.6.10.2.1.1.9 |
mp7001SystemTimingGenStatusIndicates if the units configured for primary or secondary system clock are
actually supplying clock and if it is the 8hkz, 4mhz, or both.ro Enumeration .1.3.6.1.4.1.498.6.10.2.1.1.10 |
mp7001StatLastInitializedNumber of seconds from midnight Dec 31, 1969 up until
mp7001ValidIntervals was last initialized to zeroro INTEGER .1.3.6.1.4.1.498.6.10.2.1.1.11 |
mp7001ValidIntervalsThe number of previous intervals for which
valid data was collected. The value will be 96
unless the interface was brought on-line within
the last 24 hours, in which case the value will
be the number of complete 15 minute intervals
the since interface has been online.ro INTEGER .1.3.6.1.4.1.498.6.10.2.1.1.12 |
mp7001Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.3 |
mp7001ConfigTableThe GDC Configuration table. SEQUENCE OF Mp7001ConfigEntry .1.3.6.1.4.1.498.6.10.3.1 |
mp7001ConfigEntryThe GDC Configuration table entry. Mp7001ConfigEntry .1.3.6.1.4.1.498.6.10.3.1.1 |
mp7001ConfigIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.3.1.1.1 |
mp7001NetworkInterfaceTypeSets the transmit range to DSX-1 short or DS-1 longrw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.2 |
mp7001TransmitClockSourceSets the transmit clock source.rw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.3 |
mp7001FallbackClockSourceIdentifies the fallback transmit clock source.rw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.4 |
mp7001PreEqualizationPre-Equalization distancerw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.5 |
mp7001FramingSet the framing for the interface.
Abbreviations are as follows:
eSF - Extended Super Frame
d4 - Super Framerw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.6 |
mp7001LineCodingSets the line coding for the interface.rw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.7 |
mp7001LineBuildoutSets the line build out for the interface
0, -7.5, -15 or -22.5dBrw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.8 |
mp7001FDLModeSets the Facility Data Link Mode.rw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.9 |
mp7001FramingModeSets the framing moderw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.10 |
mp7001LoopbackSets the loopback typerw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.11 |
mp7001AISLoopdownSets AIS unloop time where 4 = inhibit,
5 thru 60 = number of secondsrw INTEGER .1.3.6.1.4.1.498.6.10.3.1.1.12 |
mp7001SignalModeSets signalling moderw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.13 |
mp7001LineBuildoutCtrlSets the line buildout controlrw Enumeration .1.3.6.1.4.1.498.6.10.3.1.1.14 |
mp7001DCCConfigurationTableThe GDC DCC Configuration table. These are Diagnostic Channel
configuration options. SEQUENCE OF Mp7001DCCConfigurationEntry .1.3.6.1.4.1.498.6.10.3.2 |
mp7001DCCConfigurationEntryThe GDC Diagnostic Configuration table entry. Mp7001DCCConfigurationEntry .1.3.6.1.4.1.498.6.10.3.2.1 |
mp7001DCCConfigurationIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.3.2.1.1 |
mp7001TimeSlotTime Slot DCC goes inrw INTEGER .1.3.6.1.4.1.498.6.10.3.2.1.2 |
mp7001BandwidthBandwidth to use:
8 kbps - bit 7 only
56 kbps - bits 0 - 6
64 kbps - all 8 bitsrw Enumeration .1.3.6.1.4.1.498.6.10.3.2.1.3 |
mp7001Diagnostics OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.4 |
mp7001DiagTableThe GDC T1 Diagnostics table. Information in the entries of
this table support diagnostics testing, both active testing
via patterns, and passive testing via loopbacks. SEQUENCE OF Mp7001DiagEntry .1.3.6.1.4.1.498.6.10.4.1 |
mp7001DiagEntryThe GDC T1 Diagnostics table entry. Mp7001DiagEntry .1.3.6.1.4.1.498.6.10.4.1.1 |
mp7001DiagIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.4.1.1.1 |
mp7001TestPatternTest pattern for tests that use the pattern generator.rw Enumeration .1.3.6.1.4.1.498.6.10.4.1.1.2 |
mp7001DiagConfigSelects the test to run. noLoop(1) ends the test.rw Enumeration .1.3.6.1.4.1.498.6.10.4.1.1.3 |
mp7001TestLimitSelects the duration to run a diagnostic test. The value(1)
noLimit signifies that the test should run indefinitely until
explicitly terminated.rw Enumeration .1.3.6.1.4.1.498.6.10.4.1.1.4 |
mp7001TestExecutionStatusThis variable reports the status of a test. notInTest(1) indicates
a test is not running. testInProgress(2) indicates that a test is
currently running. testCompleted(4) indicates that a test has run
and is completed. testCompletedNotInTest(5) indicates that a test has
completed and it is no longer in test.ro Enumeration .1.3.6.1.4.1.498.6.10.4.1.1.5 |
mp7001TestExceptionsIndicates exceptions that have occurred that may affect
interpretation of the test results.
The value of this object is a sum. This sum initially take
the value zero. Then, for each exception, the value
associated with the exception is added to the sum.
The exception values are:
value exception
1 a timed test was preempted so the result
cannot be viewed in relation to the test
duration
2 the results overflowed so the result cannot be
viewed as an absolute value
4 the test was performed while synchronization
could not be performed so the result may not
be accurate.ro INTEGER .1.3.6.1.4.1.498.6.10.4.1.1.6 |
mp7001TestResultsThe results of the last diagnostic test. This can be the
current test running or the last completed test.
Note that the interpretation of these results may be affected
by the value of the mp7001TestExceptions object.ro INTEGER .1.3.6.1.4.1.498.6.10.4.1.1.7 |
mp7001ResetTestResultsResets the diagnostic error count.ro Enumeration .1.3.6.1.4.1.498.6.10.4.1.1.8 |
mp7001DS0DiagDefines a DS0 level diagnostic. Setting this object value to 0
disables a DS0 level diagnostic. Setting this object to a value
from 1 to 32 enables a DS0 level diagnostic on the DS0 indicated.
Enabling a DS0 level diagnostic bysetting this object to a value
from 1 to 32 alters the meaning of the diagnostic test to be
specific to the DS0 specified instead of the whole DS1.
Note that a DS0 level diagnostic and a DS1 level diagnostic
cannot be performed simultaneously.rw INTEGER .1.3.6.1.4.1.498.6.10.4.1.1.9 |
mp7001Performance OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.5 |
mp7001InboundANSIperfTableThe GDC ANSI Performance table. Information in the entries
of this table support the ANSI Scheduled Performance Reports.
Entries supply information for inbound
reports for the last 4 seconds. SEQUENCE OF Mp7001InboundANSIperfEntry .1.3.6.1.4.1.498.6.10.5.1 |
mp7001InboundANSIperfEntryThe GDC ANSI Performance table entry. The information in
this entry presents one of the 4 second periods performance
data in the inbound direction. Mp7001InboundANSIperfEntry .1.3.6.1.4.1.498.6.10.5.1.1 |
mp7001InboundANSIperfIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.5.1.1.1 |
mp7001InboundANSIsecondsIdentifies the reporting interval. This has the value 1 to 4
supporting up to the last 4 seconds of performance data.ro INTEGER .1.3.6.1.4.1.498.6.10.5.1.1.2 |
mp7001InboundANSICRCerrorEventsIdentifies the magnitude of the error events in the interval
which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.3 |
mp7001InboundANSIsevereErrorsIdentifies whether or not any severe errors were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.4 |
mp7001InboundANSIframeErrorsIdentifies whether or not any framing errors were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.5 |
mp7001InboundANSIcodeViolationsIdentifies whether or not any code violations were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.6 |
mp7001InboundANSIcontrolledSlipsIdentifies whether or not any controlled slips were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.7 |
mp7001InboundANSIactivePayloadLoopsIdentifies whether or not any active payload loops were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.1.1.8 |
mp7001OutboundANSIperfTableThe GDC ANSI Performance table. Information in the entries
of this table support the ANSI Scheduled Performance Reports.
Entries supply information for outbound
reports for the last 4 seconds. SEQUENCE OF Mp7001OutboundANSIperfEntry .1.3.6.1.4.1.498.6.10.5.2 |
mp7001OutboundANSIperfEntryThe GDC ANSI Performance table entry. The information in
this entry presents one of the 4 second periods performance
data in the outbound direction. Mp7001OutboundANSIperfEntry .1.3.6.1.4.1.498.6.10.5.2.1 |
mp7001OutboundANSIperfIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.5.2.1.1 |
mp7001OutboundANSIsecondsIdentifies the reporting interval. This has the value 1 to 4
supporting up to the last 4 seconds of performance data.ro INTEGER .1.3.6.1.4.1.498.6.10.5.2.1.2 |
mp7001OutboundANSICRCerrorEventsIdentifies the magnitude of the error events in the interval
which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.3 |
mp7001OutboundANSIsevereErrorsIdentifies whether or not any severe errors were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.4 |
mp7001OutboundANSIframeErrorsIdentifies whether or not any framing errors were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.5 |
mp7001OutboundANSIcodeViolationsIdentifies whether or not any code violations were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.6 |
mp7001OutboundANSIcontrolledSlipsIdentifies whether or not any controlled slips were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.7 |
mp7001OutboundANSIactivePayloadLoopsIdentifies whether or not any active payload loops were detected in
the interval which this entry represents.ro Enumeration .1.3.6.1.4.1.498.6.10.5.2.1.8 |
mp7001CurrentTableThe mp7001 Current table. This table supplements the
entries in the DS1 AT&T performance table of the DS1
MIB defined in RFC1406. SEQUENCE OF Mp7001CurrentEntry .1.3.6.1.4.1.498.6.10.5.3 |
mp7001CurrentEntryAn entry in the mp7001 Current table. Mp7001CurrentEntry .1.3.6.1.4.1.498.6.10.5.3.1 |
mp7001CurrentIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.5.3.1.1 |
mp7001CurrentStatReturns a bitwise snapshot of the current statistics.
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 1: New Interval
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 12 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 13 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 14 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 15 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 16 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 17 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.6.10.5.3.1.2 |
mp7001IntervalTableThe mp7001 Interval table. This table supplements the
entries in the DS1 AT&T performance table of the DS1
MIB defined in RFC1406. SEQUENCE OF Mp7001IntervalEntry .1.3.6.1.4.1.498.6.10.5.4 |
mp7001IntervalEntryAn entry in the DS1 Interval table. Mp7001IntervalEntry .1.3.6.1.4.1.498.6.10.5.4.1 |
mp7001IntervalIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.5.4.1.1 |
mp7001IntervalNumberA number between 1 and 96, where 1 is the most recently completed
15 minute interval and 96 is the least recently completed 15 minutes
interval (assuming that all 96 intervals are valid).ro INTEGER .1.3.6.1.4.1.498.6.10.5.4.1.2 |
mp7001IntervalStatReturns a bitwise snapshot of the interval statistics.
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 2 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 4 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 5 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 6 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 7 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 8 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 10 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 13 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 14 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 15 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 16 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.6.10.5.4.1.3 |
mp7001TotalTableThe DS1 Total table. 24 hour interval.
This table supplements the entries in the DS1
AT&T performance table of the DS1
MIB defined in RFC1406. SEQUENCE OF Mp7001TotalEntry .1.3.6.1.4.1.498.6.10.5.5 |
mp7001TotalEntryAn entry in the DS1 Total table. Mp7001TotalEntry .1.3.6.1.4.1.498.6.10.5.5.1 |
mp7001TotalIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.5.5.1.1 |
mp7001TotalStatReturns a bitwise snapshot of the total statistics.
Octet 1 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 1: New Interval
Octet 2 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 3 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 4 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Errored Seconds
Octet 5 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 6 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Severely Errored Seconds
Octet 8 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 9 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Bursty Errored Seconds
Octet 11 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - 2^15
bit 0 - 2^14
Octet 12 bit 7 - not used
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 13 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Unavailable Seconds
Octet 14 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 15 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Controlled Slip Seconds
Octet 16 bit 7 - not used
bit 6 - future use
bit 5 - future use
bit 4 - future use
bit 3 - future use
bit 2 - future use
bit 1 - future use
bit 0 - 2^7
Octet 17 bit 7 - not used
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 Loss of Frame Countro OCTET STRING .1.3.6.1.4.1.498.6.10.5.5.1.2 |
mp7001AlarmConfig OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.6 |
mp7001NearEndAlarmConfigTableThis table contains entries that configure Near End Alarm reporting. SEQUENCE OF Mp7001NearEndAlarmConfigEntry .1.3.6.1.4.1.498.6.10.6.1 |
mp7001NearEndAlarmConfigEntryAn entry in the MP7001 Alarm Configuration table. Mp7001NearEndAlarmConfigEntry .1.3.6.1.4.1.498.6.10.6.1.1 |
mp7001NearEndAlarmConfigIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.6.1.1.1 |
mp7001NearEndAlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type.
The format of this identifier is an OBJECT IDENTIFIER that has
the following format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y)
where xxx(x) is the administratively assigned family object
identifier (z) is the object identifier for alarms in the family
defined MIB and yyy(y) is the administratively assigned alarm
type identifier for this alarm.ro OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.6.1.1.2 |
mp7001NearEndAlarmCountWindowThis variable sets/reads the alarm window.
This window is used with the alarm threshold to determine
how long the alarm should be active before reporting.
Default: disabled(1)rw Enumeration .1.3.6.1.4.1.498.6.10.6.1.1.3 |
mp7001NearEndAlarmCountThresholdThis function sets/reads the alarm threshold criteria.
This threshold is used along with the the alarm window to
determine the number of instances in a given time frame for
an alarm to occur before the alarm is considered active.
Default: thresGT1(1)rw Enumeration .1.3.6.1.4.1.498.6.10.6.1.1.4 |
mp7001LocalAlarmConfigTableThe mp7001LocalAlarmConfigTable contains entries that configure
alarm reporting to the alarm card. SEQUENCE OF Mp7001LocalAlarmConfigEntry .1.3.6.1.4.1.498.6.10.6.2 |
mp7001LocalAlarmConfigEntryAn entry in the GDC Local Alarm Configuration table. Mp7001LocalAlarmConfigEntry .1.3.6.1.4.1.498.6.10.6.2.1 |
mp7001LocalAlarmConfigIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.6.2.1.1 |
mp7001LOSLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.2 |
mp7001LOFLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.3 |
mp7001AISLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.4 |
mp7001RxYELLOWLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.5 |
mp7001BPVLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.6 |
mp7001CRCLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.7 |
mp7001UnSigStateLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.8 |
mp7001TiminglossLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.9 |
mp7001ESLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.10 |
mp7001BESLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.11 |
mp7001SESLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.12 |
mp7001UASLocalDisables or enables the alarm on the Major buss or Minor
buss.rw Enumeration .1.3.6.1.4.1.498.6.10.6.2.1.13 |
mp7001SysConfig OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.7 |
mp7001SysTimingTableThe GDC System Timing table. SEQUENCE OF Mp7001SysTimingEntry .1.3.6.1.4.1.498.6.10.7.1 |
mp7001SysTimingEntryThe GDC Configuration table entry. Mp7001SysTimingEntry .1.3.6.1.4.1.498.6.10.7.1.1 |
mp7001SysTimingIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.7.1.1.1 |
mp7001SysTimingGenSelects if the unit provides system timing.
none(1) - does not provide Timing Generator
primary(2) - unit is primary Timing Generator for the shelf.
secondary(3) - unit is secondary Timing Generator for the
shelf.
Only 1 unit in the shelf can the primary or secondary
timing generator. All other must be none.rw Enumeration .1.3.6.1.4.1.498.6.10.7.1.1.2 |
mp7001HighwayAssignTableThe GDC Highway/Timeslot Assignment Table. SEQUENCE OF Mp7001HighwayAssignEntry .1.3.6.1.4.1.498.6.10.7.2 |
mp7001HighwayAssignEntryThe GDC T1 Highway Assign table entry. Mp7001HighwayAssignEntry .1.3.6.1.4.1.498.6.10.7.2.1 |
mp7001HighwayAssignIndexInteger value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)ro SCinstance .1.3.6.1.4.1.498.6.10.7.2.1.1 |
mp7001StartTimeSlotStarting time slot of the bundle. If only 1 bundle is
being assigned, or the first of 2 is being assigned,
it must start at 1. The second of 2 must start at the next
available time slot after the first bundle.rw INTEGER .1.3.6.1.4.1.498.6.10.7.2.1.2 |
mp7001NumberOfTimeSlotsNumber of time slots assigned to the bundle.rw INTEGER .1.3.6.1.4.1.498.6.10.7.2.1.3 |
mp7001BundleDestinationDefines the destination of the bundle.rw Enumeration .1.3.6.1.4.1.498.6.10.7.2.1.4 |
mp7001ExecuteAssignCauses the MP7001 to execute configuration of the assigned
highway configuration. This object should be sent in a separate
PDU after acknowlegement of the assign PDU(s) has been received.rw Enumeration .1.3.6.1.4.1.498.6.10.7.2.1.5 |
mp7001Alarms OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8 |
mp7001NoResponseAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.1 |
mp7001DiagRxErrAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.2 |
mp7001PowerUpAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.3 |
mp7001NvRamCorrupt OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.4 |
mp7001UnitFailure OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.5 |
mp7001LossOfSignal OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.6 |
mp7001LossOfFrame OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.7 |
mp7001Ais OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.8 |
mp7001YELLOW OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.9 |
mp7001BipolarViolation OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.10 |
mp7001CRC OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.11 |
mp7001UnSigState OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.12 |
mp7001TimingLoss OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.13 |
mp7001ES OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.14 |
mp7001BES OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.15 |
mp7001SES OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.16 |
mp7001UAS OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.17 |
mp7001ControlSlips OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.18 |
mp7001UnsolicitedTest OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.10.8.19 |