Home/Catalog/GDC7616-MIB

GDC7616-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

118
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

118 total
Object Name
gdc
OBJECT IDENTIFIER
.1.3.6.1.4.1.498
RFC1213-MIB
Unknown
.1.3.6.1.4.1.498
bql2
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12
uas7616
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.4
uas7616MIBVersionThe version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.ro
DisplayString
.1.3.6.1.4.1.498.12.4.1
uas7616WhatAreYouTableThe GDC 7616 What Are You Table.
SEQUENCE OF Uas7616WhatAreYouEntry
.1.3.6.1.4.1.498.12.4.2
uas7616WhatAreYouEntryAn entry in the GDC 7616 What Are You table.
Uas7616WhatAreYouEntry
.1.3.6.1.4.1.498.12.4.2.1
uas7616WhatAreYouIndexThis object is the identifier of the 7616 What Are You table.ro
SCinstance
.1.3.6.1.4.1.498.12.4.2.1.1
uas7616CodeRevThis function returns the firmware code level. Example A- ,B-ro
DisplayString
.1.3.6.1.4.1.498.12.4.2.1.2
uas7616AlarmStatusThe current alarms of the unit without the alarm masks.ro
OCTET STRING
.1.3.6.1.4.1.498.12.4.2.1.3
uas7616SystemTimingGenStatusIndicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both.ro
Enumeration
.1.3.6.1.4.1.498.12.4.2.1.4
uas7616ConfigTableThe GDC 7616 configuration table.
SEQUENCE OF Uas7616ConfigEntry
.1.3.6.1.4.1.498.12.4.3
uas7616ConfigEntryA listing of GDC 2B1Q 7616 options.
Uas7616ConfigEntry
.1.3.6.1.4.1.498.12.4.3.1
uas7616ConfigIndexA unique index for the Configuration Table.ro
SCinstance
.1.3.6.1.4.1.498.12.4.3.1.1
uas7616TXClockSourceObject to select the Transmit Clock Source for the 7616.rw
Enumeration
.1.3.6.1.4.1.498.12.4.3.1.2
uas7616TerminationTypeObject to select the Termination Type for the 7616.rw
Enumeration
.1.3.6.1.4.1.498.12.4.3.1.3
uas7616ChADataRateObject to select the Data Rate on Channel A, Loop n.rw
Enumeration
.1.3.6.1.4.1.498.12.4.3.1.4
uas7616ChBDataRateObject to select the Data Rate on Channel B, Loop n.rw
Enumeration
.1.3.6.1.4.1.498.12.4.3.1.5
uas7616ControlTableThe GDC 7616 Control Table.
SEQUENCE OF Uas7616ControlEntry
.1.3.6.1.4.1.498.12.4.5
uas7616ControlEntryAn entry in the GDC 7616 Control table.
Uas7616ControlEntry
.1.3.6.1.4.1.498.12.4.5.1
uas7616ControlIndexThis object is the identifier of the 7616 Control table.ro
SCinstance
.1.3.6.1.4.1.498.12.4.5.1.1
uas7616SoftResetForces a soft reset on the network element. The reset selection is write only. The normal selection is read only.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.2
uas7616EraseConfigForces an erase of the stored configuration in the network element. The erase selection is write only.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.3
uas7616LEDStatusThe GDC 7616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - loop 1 channel A (00 = No Change 01 = Green Active) 1.4 - (10 = Red Solid 11 = RedFlashing ) 1.3 - loop 1 channel B (00 = No Change 01 = Green Active) 1.2 - (10 = Red Solid 11 = RedFlashing ) 1.1 - loop 2 channel A (00 = No Change 01 = Green Active) 1.0 - (10 = Red Solid 11 = RedFlashing ) 2.7 - not used 2.6 - not used 2.5 - loop 2 channel B (00 = No Change 01 = Green Active) 2.4 - (10 = Red Solid 11 = RedFlashing ) 2.3 - loop 3 channel A (00 = No Change 01 = Green Active) 2.2 - (10 = Red Solid 11 = RedFlashing ) 2.1 - loop 3 channel B (00 = No Change 01 = Green Active) 2.0 - (10 = Red Solid 11 = RedFlashing ) 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - alarm led 3.3 - test mode led 3.2 - in service 3.1 - system timing source 3.0 - management responsero
OCTET STRING
.1.3.6.1.4.1.498.12.4.5.1.4
uas7616InterfaceTypeObject used to configure the transmission interface type.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.5
uas7616SysTimingGenSelects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.6
uas7616ResetIntervalsThis variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.7
uas7616SysUpTimeThis variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.ro
INTEGER
.1.3.6.1.4.1.498.12.4.5.1.8
uas7616SetRealTimeNumber of seconds from midnight Dec 31, 1969.rw
INTEGER
.1.3.6.1.4.1.498.12.4.5.1.9
uas7616ModuleClkSrcThis variable is used to read or set the Module Clock Source. This variable must be system when uas7616SysTimingGen is set to none. Any of the three selections when uas7616SysTimingGen is set to secondary, and internal or recovered when uas7616SysTimingGen is set to primary.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.10
uas7616ResetMajorAlarmThis variable is used to reset alarm per Loop basis.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.11
uas7616ResetMinorAlarmThis variable is used to reset alarm per Loop basis.rw
Enumeration
.1.3.6.1.4.1.498.12.4.5.1.12
uas7616DiagnosticTableThe GDC 7616 diagnostics table.
SEQUENCE OF Uas7616DiagnosticEntry
.1.3.6.1.4.1.498.12.4.6
uas7616DiagnosticEntryA listing of GDC 7616 diagnostic tests
Uas7616DiagnosticEntry
.1.3.6.1.4.1.498.12.4.6.1
uas7616DiagnosticIndexA unique index for the Diagnostic Table.ro
SCinstance
.1.3.6.1.4.1.498.12.4.6.1.1
uas7616DiagnosticChnlIndexA unique channel index for the Channel the test will run on.ro
Enumeration
.1.3.6.1.4.1.498.12.4.6.1.2
uas7616DiagnosticTestSelections digitalLoopback(2), patternGenTest(3), and unitTest(4) start the associated test when written. Reading will show which (if any) test is active. Writing a stopTestwill stop the test if any was in progress.rw
Enumeration
.1.3.6.1.4.1.498.12.4.6.1.3
uas7616DiagnosticResetErrorCountThis function resets the error count on a given loop and channel. Management will always read a norm(1) and can only write a reset(2).rw
Enumeration
.1.3.6.1.4.1.498.12.4.6.1.4
uas7616DiagnosticResultsThis function reads the self test results in bit errors. 2^20ro
INTEGER
.1.3.6.1.4.1.498.12.4.6.1.5
uas7616Current15MinTableThe 7616 15 Min Current table.
SEQUENCE OF Uas7616Current15MinEntry
.1.3.6.1.4.1.498.12.4.8
uas7616Current15MinEntryAn entry in the 7616 Current table.
Uas7616Current15MinEntry
.1.3.6.1.4.1.498.12.4.8.1
uas7616Current15MinIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.8.1.1
uas7616Current15MinStatReturns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 4 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 6 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)ro
OCTET STRING
.1.3.6.1.4.1.498.12.4.8.1.2
uas7616IntervalTableThe 7616 Interval table.
SEQUENCE OF Uas7616IntervalEntry
.1.3.6.1.4.1.498.12.4.9
uas7616IntervalEntryAn entry in the Interval table.
Uas7616IntervalEntry
.1.3.6.1.4.1.498.12.4.9.1
uas7616IntervalIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.9.1.1
uas7616IntervalNumberThe number of Errored Seconds, Unavailable Seconds & Severely Errored Seconds encountered in one of the previous 16, individual 15 minute, intervals.ro
INTEGER
.1.3.6.1.4.1.498.12.4.9.1.2
uas7616IntervalStatReturns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Interval Octet 3 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 6 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 7 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 9 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 10 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 11 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)ro
OCTET STRING
.1.3.6.1.4.1.498.12.4.9.1.3
uas7616Current24HrTableThe Current24Hr table. 4 hour interval.
SEQUENCE OF Uas7616Current24HrEntry
.1.3.6.1.4.1.498.12.4.10
uas7616Current24HrEntryAn entry in the Current24Hr table.
Uas7616Current24HrEntry
.1.3.6.1.4.1.498.12.4.10.1
uas7616Current24HrIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.10.1.1
uas7616Current24HrStatReturns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)ro
OCTET STRING
.1.3.6.1.4.1.498.12.4.10.1.2
uas7616Recent24HrTableThe Recent24Hr table. 4 hour interval.
SEQUENCE OF Uas7616Recent24HrEntry
.1.3.6.1.4.1.498.12.4.11
uas7616Recent24HrEntryAn entry in the Recent24Hr table.
Uas7616Recent24HrEntry
.1.3.6.1.4.1.498.12.4.11.1
uas7616Recent24HrIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.11.1.1
uas7616Recent24HrStatReturns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)ro
OCTET STRING
.1.3.6.1.4.1.498.12.4.11.1.2
uas7616UnavailableTimeRegTableThe 7616 Unavailable Time Register table.
SEQUENCE OF Uas7616UnavailableTimeRegEntry
.1.3.6.1.4.1.498.12.4.12
uas7616UnavailableTimeRegEntryAn entry in the Unavailable Time Register table.
Uas7616UnavailableTimeRegEntry
.1.3.6.1.4.1.498.12.4.12.1
uas7616UnavailableTimeRegIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.12.1.1
uas7616UnavailableTimeRegNumberA number between 1 and 6, where the number is the number of the Unavailable Time Register.ro
INTEGER
.1.3.6.1.4.1.498.12.4.12.1.2
uas7616UnavailableTimeRegStartStart time of one of the Unavailable Time Registers.ro
INTEGER
.1.3.6.1.4.1.498.12.4.12.1.3
uas7616UnavailableTimeRegStopStop time of one of the Unavailable Time Registers.ro
INTEGER
.1.3.6.1.4.1.498.12.4.12.1.4
uas7616IntervalMaintenanceTableThe 7616 Loop Interval Maintenance table.
SEQUENCE OF Uas7616IntervalMaintenanceEntry
.1.3.6.1.4.1.498.12.4.13
uas7616IntervalMaintenanceEntryThe 7616 Interval Maintenance table entry.
Uas7616IntervalMaintenanceEntry
.1.3.6.1.4.1.498.12.4.13.1
uas7616IntervalMaintenanceIndexThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface.ro
SCinstance
.1.3.6.1.4.1.498.12.4.13.1.1
uas7616NumberofValidIntervalsThis variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.ro
INTEGER
.1.3.6.1.4.1.498.12.4.13.1.2
uas7616LocalAlarmConfigTableThe 7616LocalAlarmConfigTable contains entries that configure alarm reporting.
SEQUENCE OF Uas7616LocalAlarmConfigEntry
.1.3.6.1.4.1.498.12.4.14
uas7616LocalAlarmConfigEntryAn entry in the GDC Local Alarm Configuration table.
Uas7616LocalAlarmConfigEntry
.1.3.6.1.4.1.498.12.4.14.1
uas7616LocalAlarmConfigIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.4.14.1.1
uas7616LocalLossOfClockDisables or enables the Loss of Clock alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.2
uas7616LocalUASDisables or enables the UAS alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.3
uas7616LocalSESDisables or enables the SES alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.4
uas7616LocalESDisables or enables the ES alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.5
uas7616LocalOutOfSyncDisables or enables the Out of Sync alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.6
uas7616LocalNoSealingCurrentDisables or enables the No Sealing Current alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.7
uas7616LPMajorDisables or enables the Major alarm on the Major buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.8
uas7616LPMinorDisables or enables the Minor alarm on the Minor buss or Minor buss.rw
Enumeration
.1.3.6.1.4.1.498.12.4.14.1.9
uas7616TSAssignTableThe 7616TSAssignTable contains entries that provide a means to assign a highway and time slot of that highway to the channel of a loop.
SEQUENCE OF Uas7616TSAssignEntry
.1.3.6.1.4.1.498.12.4.15
uas7616TSAssignEntryAn entry in the GDC Circuit Identification table.
Uas7616TSAssignEntry
.1.3.6.1.4.1.498.12.4.15.1
uas7616TSAssignIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.4.15.1.1
uas7616ChannelIndexThe index value which uniquely identifies the channel of the interface to which this entry is applicable.rw
Enumeration
.1.3.6.1.4.1.498.12.4.15.1.2
uas7616HighwayDefines the highway the channel of the loop is assigned to.rw
Enumeration
.1.3.6.1.4.1.498.12.4.15.1.3
uas7616TimeSlotDefines the time slot of the highway the channel of the loop is assigned to. Valid range is 1 to 31. A value of 64 indicates the channel is not assigned to a highway.rw
INTEGER
.1.3.6.1.4.1.498.12.4.15.1.4
uas7616TSCircuitIDName to identify the circuit for the channel of this loop.rw
DisplayString
.1.3.6.1.4.1.498.12.4.15.1.5
uas7616Alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13
uas7616AlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1
uas7616NoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.1
uas7616DiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.2
uas7616PowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.3
uas7616LossOfClockAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.4
uas7616LpOutofSyncAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.5
uas7616LpSealingCurrentNoContinuityAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.6
uas7616LpUnavailableSecondAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.7
uas7616LpSeverelyErroredSecondAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.8
uas7616LpErroredSecondAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.1.9
uas7616AlarmConfigTableThe uas7616AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
SEQUENCE OF Uas7616AlarmConfigEntry
.1.3.6.1.4.1.498.12.13.2
uas7616AlarmConfigEntryAn entry in the GDC Alarm Configuration table.
Uas7616AlarmConfigEntry
.1.3.6.1.4.1.498.12.13.2.1
uas7616AlarmConfigIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.13.2.1.1
uas7616AlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.13.2.1.2
uas7616AlarmCountWindowThis variable sets/reads the UAS, SES or ES alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting.rw
Enumeration
.1.3.6.1.4.1.498.12.13.2.1.3
uas7616AlarmCountThresholdThis function sets/reads the UAS, SES or ES alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active.rw
Enumeration
.1.3.6.1.4.1.498.12.13.2.1.4
uas7616mAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14
uas7616mAlarmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1
uas7616mNoResponseAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.1
uas7616mDiagRxErrAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.2
uas7616mPowerUpAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.3
uas7616mLossOfClockAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.4
uas7616mLpOutofSyncAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.5
uas7616mLpSealingCurrentNoContinuityAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.6
uas7616mLpUnavailableSecondAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.7
uas7616mLpErroredSecondAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.8
uas7616mLPMajorAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.9
uas7616mLPMinorAlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.1.10
uas7616mAlarmConfigTableThe uas7616mAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
SEQUENCE OF Uas7616mAlarmConfigEntry
.1.3.6.1.4.1.498.12.14.2
uas7616mAlarmConfigEntryAn entry in the GDC Alarm Configuration table.
Uas7616mAlarmConfigEntry
.1.3.6.1.4.1.498.12.14.2.1
uas7616mAlarmConfigIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
SCinstance
.1.3.6.1.4.1.498.12.14.2.1.1
uas7616mAlarmConfigIdentifierThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.498.12.14.2.1.2
uas7616mAlarmCountThresholdThis function sets/reads the Major or Minor BER alarm threshold criteria.rw
Enumeration
.1.3.6.1.4.1.498.12.14.2.1.3