EXTREME-TRAP-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for EXTREME-TRAP-MIB.
19
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
19 total| Object Name |
|---|
extremenetworks OBJECT IDENTIFIER .1.3.6.1.4.1.1916 |
IF-MIB NOTIFICATION-TYPE .1.3.6.1.4.1.1916 |
extremeV1Traps OBJECT IDENTIFIER .1.3.6.1.4.1.1916.0 |
extremeOverheatA overheat trap indicates that the on board
tempature sensor has reported a overheat
condition. System will shutdown until unit has
suficiently cooled such that operation may begin
again. A cold start trap will be issued when
the unit has come back on line. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.6 |
extremeFanfailedA fan failed trap indicates one or more of the
cooling fans inside the device has failed. A
fanOK trap will be sent once the fan has attained
normal operation. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.7 |
extremeFanOKA fan has transitioned out of a failure state and
is now operating correctly. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.8 |
extremeInvalidLoginAttemptA user attempted to login to console or by telnet but was
refused access due to incorrect username or password NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.9 |
extremePowerSupplyFailOne or more sources of power to this agent has failed.
Presumably a redundant power-supply has taken over. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.10 |
extremePowerSupplyGoodOne or more previously bad sources of power to this agent
has come back to life without causing an agent restart. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.11 |
extremeRpsAlarmAttached Redundant Power Supply device is indicating
an alarm condition. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.12 |
extremeRpsNoAlarmAttached Redundant Power Supply device is no longer
indicating an alarm condition. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.13 |
extremeSmartTrapSignifies that the value of one of the object identifiers
(or the value of an object below that in the MIB tree)
defined in the extremeSmartTrapRulesTable has changed,
and hence a new entry has been created in the
extremeSmartTrapInstanceTable. Such a trap is sent
at most once every thirty seconds if one or more entry
was created in the last thirty seconds. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.14 |
extremeModuleStateChangedSignifies that the value of the extremeSlotModuleState for
the specified extremeSlotNumber has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.15 |
extremeEsrpStateChangeSignifies Esrp state change NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.17 |
extremeSlbUnitAddedThe server load balancer has activated a group of virtual
servers that it normally would not activate. This may be
due to the failure of another server load balancer. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.18 |
extremeSlbUnitRemovedThe server load balancer has deactivated a group of virtual
servers that it normally has active. This indicates that
something is wrong in the server load balancer; for example,
its ping check may be failing. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.19 |
extremeEdpNeighborAddedThis node discovers a new neighbor through Extreme Discovery
Protocol. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.20 |
extremeEdpNeighborRemovedNo EDP updates are received from this neighbor within
the configured timeout period and this neighbor entry is aged
out by the device. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.21 |
extremeCpuHealthCheckFailedCpu HealthCheck has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.1916.0.22 |