Home/Catalog/ERICSSON-ROUTER-STACKING-ALARM-MIB

ERICSSON-ROUTER-STACKING-ALARM-MIB

AI MIB Summary

ERICSSON-ROUTER-STACKING-ALARM-MIB monitors fault conditions within Ericsson router stacking configurations by exposing specific alarm indicators that signal violations of stacking topology requirements or member link failures. This module enables network management systems to detect and report critical stacking anomalies, such as split-brain scenarios or synchronization losses, to ensure the integrity of the high-availability cluster.

This MIB provides the possibility to report alarms according to the stacking requirements for fault management.
Main OID:
eriRouterStackingAlarmMib.1.3.6.1.4.1.193.218.2.117
23
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

23 total
Object Name
eriRouterStackingAlarmMibThis MIB provides the possibility to report alarms according to the stacking requirements for fault management.
MODULE-IDENTITY
.1.3.6.1.4.1.193.218.2.117
eriRouterStackingAlarmNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.1
eriRouterStackingIdMismatchAlarmThis notification is triggered when a stacking Id mismatch is found between connected chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.1
eriRouterStackingChassisNumberMismatchAlarmThis notification is triggered when a chassis number mismatch is found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.2
eriRouterStackingChassisNotFoundAlarmThis notification is triggered when a configured chassis is not found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.3
eriRouterStackingChassisTypeMismatchAlarmThis notification is triggered when a chassis physically connected to the stack is not of a supported chassis type, or the chassis connected is not same as the configured type.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.4
eriRouterStackingChassisUIDFormatMismatchAlarmThis notification is triggered when a chassis physically connected to the stack does not support the configured UID format.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.5
eriRouterStackingLicenseNotAvailableAlarmThis notification is triggered when a stacking license is missing or unavailable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.193.218.2.117.1.6
eriRouterStackingAlarmObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.2
eriRouterStackingAlarmNotify
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.2.1
eriRouterStackingAlarmEventStackIdThe value of this object contains the stack's identifier.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.193.218.2.117.2.1.1
eriRouterStackingAlarmEventChassisUIDThe value of this object contains a chassis' UID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.193.218.2.117.2.1.2
eriRouterStackingAlarmEventDateAndTimeThe date and time when the event was raised.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.193.218.2.117.2.1.3
eriRouterStackingAlarmEventSeverityThe current severity of the event.ro
ItuPerceivedSeverity (ITU-ALARM-TC-MIB)
.1.3.6.1.4.1.193.218.2.117.2.1.4
eriRouterStackingAlarmEventProbableCauseThe probable cause for this event.ro
IANAItuProbableCause (IANA-ITU-ALARM-TC-MIB)
.1.3.6.1.4.1.193.218.2.117.2.1.5
eriRouterStackingAlarmEventAdditionalTextThe additional text of the event.ro
SnmpAdminString
.1.3.6.1.4.1.193.218.2.117.2.1.6
eriRouterStackingAlarmEventMinorTypeThe minor type of the event.ro
INTEGER
.1.3.6.1.4.1.193.218.2.117.2.1.7
eriRouterStackingAlarmConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.3
eriRouterStackingAlarmCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.3.1
eriRouterStackingAlarmComplianceThe compliance statement for SNMP entities which implement the STACKING ALARM MIB.
Unknown
.1.3.6.1.4.1.193.218.2.117.3.1.1
eriRouterStackingAlarmGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.193.218.2.117.3.2
eriRouterStackingAlarmNotifyObjectGroupThe collection of objects related to STACKING ALARM notifications.
Unknown
.1.3.6.1.4.1.193.218.2.117.3.2.1
eriRouterStackingAlarmNotifyGroupNotification for tracking STACKING ALARM events.
Unknown
.1.3.6.1.4.1.193.218.2.117.3.2.2