ERICSSON-ROUTER-PVC-MIB
AI MIB Summary
The ERICSSON-ROUTER-PVC-MIB enables monitoring and configuration of ATM, Frame Relay, and IEEE 802.1Q permanent virtual circuit parameters, including circuit status, traffic statistics, and QoS attributes, on Ericsson router platforms.
Defines the objects necessary to support the management of ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits (PVC).
Main OID:
eriRouterPvcMib.1.3.6.1.4.1.193.218.2.7
77
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
77 total| Object Name |
|---|
eriRouterPvcMibDefines the objects necessary to support the management of ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits (PVC). MODULE-IDENTITY .1.3.6.1.4.1.193.218.2.7 |
eriRouterPvcMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.193.218.2.7.1 |
eriRouterAtmPvcConfigTableThis table contains the objects which identify and configure ATM PVCs. SEQUENCE OF EriRouterAtmPvcConfigEntry .1.3.6.1.4.1.193.218.2.7.1.1 |
eriRouterAtmPvcConfigEntryA conceptual row in the eriRouterAtmPvcConfigTable. EriRouterAtmPvcConfigEntry .1.3.6.1.4.1.193.218.2.7.1.1.1 |
eriRouterAtmPvcSlotThe chassis slot number EriRouterSlot (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.1.1.1 |
eriRouterAtmPvcPortThe port number EriRouterPort (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.1.1.2 |
eriRouterAtmPvcVpiThe Virtual Path Identifier for the PVC. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.1.1.3 |
eriRouterAtmPvcVciThe Virtual Channel Identifier for the PVC. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.1.1.4 |
eriRouterAtmPvcProfileNameThe profile name to use with the PVC.rw SnmpAdminString .1.3.6.1.4.1.193.218.2.7.1.1.1.5 |
eriRouterAtmPvcEncapsulationThe encapsulation to use with the PVC.rw EriRouterAtmEncapsulation .1.3.6.1.4.1.193.218.2.7.1.1.1.6 |
eriRouterAtmPvcRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.1.1.8 |
eriRouterAtmPvcCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose eriRouterAtmPvcCircuitType has a value 'explicit' may be removed by setting eriRouterAtmPvcRowStatus equal to 'destroy'. A set operation with eriRouterAtmPvcRowStatus equal to 'destroy' on any row with eriRouterAtmPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw EriRouterPvcCircuitType .1.3.6.1.4.1.193.218.2.7.1.1.1.9 |
eriRouterAtmPvcCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB.ro EriRouterCircuitHandle (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.1.1.10 |
eriRouterAtmPvcClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1483(2) or route1483(4), subscribers will re-authenticate after being cleared.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.1.1.11 |
eriRouterFrameRelayPvcConfigTableThis table contains the objects which identify and configure Frame Relay PVCs. SEQUENCE OF EriRouterFrameRelayPvcConfigEntry .1.3.6.1.4.1.193.218.2.7.1.2 |
eriRouterFrameRelayPvcConfigEntryA conceptual row in the eriRouterFrameRelayPvcConfigTable. EriRouterFrameRelayPvcConfigEntry .1.3.6.1.4.1.193.218.2.7.1.2.1 |
eriRouterFrameRelayPvcSlotThe chassis slot number EriRouterSlot (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.2.1.1 |
eriRouterFrameRelayPvcPortThe port number EriRouterPort (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.2.1.2 |
eriRouterFrameRelayPvcChannelThe channel number Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.2.1.3 |
eriRouterFrameRelayPvcDLCIThe Data Link Connection Identifier Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.2.1.4 |
eriRouterFrameRelayPvcProfileNameThe profile name to use with the PVC.rw SnmpAdminString .1.3.6.1.4.1.193.218.2.7.1.2.1.5 |
eriRouterFrameRelayPvcEncapsulationThe encapsulation to use with the PVC.rw EriRouterFrameRelayEncapsulation .1.3.6.1.4.1.193.218.2.7.1.2.1.6 |
eriRouterFrameRelayPvcRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.2.1.8 |
eriRouterFrameRelayPvcCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose eriRouterFrameRelayPvcCircuitType has a value 'explicit' may be removed by setting eriRouterFrameRelayPvcRowStatus equal to 'destroy'. A set operation with eriRouterFrameRelayPvcRowStatus equal to 'destroy' on any row with eriRouterFrameRelayPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw EriRouterPvcCircuitType .1.3.6.1.4.1.193.218.2.7.1.2.1.9 |
eriRouterFrameRelayPvcCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB.ro EriRouterCircuitHandle (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.2.1.10 |
eriRouterFrameRelayPvcClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1490(2) or route1490(4), subscribers will re-authenticate after being cleared.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.2.1.11 |
eriRouterDot1qPvcOnEthConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on Ethernet ports. SEQUENCE OF EriRouterDot1qPvcOnEthConfigEntry .1.3.6.1.4.1.193.218.2.7.1.3 |
eriRouterDot1qPvcOnEthConfigEntryA conceptual row in the eriRouterDot1qPvcOnEthConfigTable. EriRouterDot1qPvcOnEthConfigEntry .1.3.6.1.4.1.193.218.2.7.1.3.1 |
eriRouterDot1qPvcOnEthSlotThe chassis slot number. EriRouterSlot (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.1 |
eriRouterDot1qPvcOnEthPortThe port number. EriRouterPort (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.2 |
eriRouterDot1qPvcOnEthVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value. EriRouterVidOrUntagged (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.3 |
eriRouterDot1qPvcOnEthRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.4 |
eriRouterDot1qPvcOnEthProfileNameThe profile name to use with the PVC.rw SnmpAdminString .1.3.6.1.4.1.193.218.2.7.1.3.1.5 |
eriRouterDot1qPvcOnEthEncapsulationThe encapsulation to use with the PVC.rw EriRouterDot1qEncapsulation .1.3.6.1.4.1.193.218.2.7.1.3.1.6 |
eriRouterDot1qPvcOnEthCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnEthCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnEthRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnEthRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnEthCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw EriRouterPvcCircuitType .1.3.6.1.4.1.193.218.2.7.1.3.1.7 |
eriRouterDot1qPvcOnEthCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB.ro EriRouterCircuitHandle (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.8 |
eriRouterDot1qPvcOnEthClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.3.1.9 |
eriRouterDot1qPvcOnAtmConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits. SEQUENCE OF EriRouterDot1qPvcOnAtmConfigEntry .1.3.6.1.4.1.193.218.2.7.1.4 |
eriRouterDot1qPvcOnAtmConfigEntryA conceptual row in the eriRouterDot1qPvcOnAtmConfigTable. EriRouterDot1qPvcOnAtmConfigEntry .1.3.6.1.4.1.193.218.2.7.1.4.1 |
eriRouterDot1qPvcOnAtmSlotThe chassis slot number. EriRouterSlot (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.1 |
eriRouterDot1qPvcOnAtmPortThe port number. EriRouterPort (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.2 |
eriRouterDot1qPvcOnAtmVpiThe Virtual Path Identifier for the PVC. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.4.1.3 |
eriRouterDot1qPvcOnAtmVciThe Virtual Channel Identifier for the PVC. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.4.1.4 |
eriRouterDot1qPvcOnAtmVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value. EriRouterVidOrUntagged (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.5 |
eriRouterDot1qPvcOnAtmRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.6 |
eriRouterDot1qPvcOnAtmProfileNameThe profile name to use with the PVC.rw SnmpAdminString .1.3.6.1.4.1.193.218.2.7.1.4.1.7 |
eriRouterDot1qPvcOnAtmEncapsulationThe encapsulation to use with the PVC.rw EriRouterDot1qEncapsulation .1.3.6.1.4.1.193.218.2.7.1.4.1.8 |
eriRouterDot1qPvcOnAtmCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnAtmCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnAtmCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw EriRouterPvcCircuitType .1.3.6.1.4.1.193.218.2.7.1.4.1.9 |
eriRouterDot1qPvcOnAtmCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB.ro EriRouterCircuitHandle (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.10 |
eriRouterDot1qPvcOnAtmClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.4.1.11 |
eriRouterDot1qPvcOnFrConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits. SEQUENCE OF EriRouterDot1qPvcOnFrConfigEntry .1.3.6.1.4.1.193.218.2.7.1.5 |
eriRouterDot1qPvcOnFrConfigEntryA conceptual row in the eriRouterDot1qPvcOnFrConfigTable. EriRouterDot1qPvcOnFrConfigEntry .1.3.6.1.4.1.193.218.2.7.1.5.1 |
eriRouterDot1qPvcOnFrSlotThe chassis slot number. EriRouterSlot (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.1 |
eriRouterDot1qPvcOnFrPortThe port number. EriRouterPort (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.2 |
eriRouterDot1qPvcOnFrChannelThe channel number. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.5.1.3 |
eriRouterDot1qPvcOnFrDLCIThe Data Link Connection Identifier. Unsigned32 .1.3.6.1.4.1.193.218.2.7.1.5.1.4 |
eriRouterDot1qPvcOnFrVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value. EriRouterVidOrUntagged (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.5 |
eriRouterDot1qPvcOnFrRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.6 |
eriRouterDot1qPvcOnFrProfileNameThe profile name to use with the PVC.rw SnmpAdminString .1.3.6.1.4.1.193.218.2.7.1.5.1.7 |
eriRouterDot1qPvcOnFrEncapsulationThe encapsulation to use with the PVC.rw EriRouterDot1qEncapsulation .1.3.6.1.4.1.193.218.2.7.1.5.1.8 |
eriRouterDot1qPvcOnFrCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose eriRouterDot1qPvcOnFrCircuitType has a value 'explicit' may be removed by setting eriRouterDot1qPvcOnFrRowStatus equal to 'destroy'. A set operation with eriRouterDot1qPvcOnFrRowStatus equal to 'destroy' on any row with eriRouterDot1qPvcOnFrCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw EriRouterPvcCircuitType .1.3.6.1.4.1.193.218.2.7.1.5.1.9 |
eriRouterDot1qPvcOnFrCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the eriRouterBindTable defined in the ERICSSON-ROUTER-BIND-MIB.ro EriRouterCircuitHandle (ERICSSON-ROUTER-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.10 |
eriRouterDot1qPvcOnFrClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.193.218.2.7.1.5.1.11 |
eriRouterPvcMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.193.218.2.7.2 |
eriRouterPvcCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.193.218.2.7.2.1 |
eriRouterPvcComplianceThe compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB.deprecated Unknown .1.3.6.1.4.1.193.218.2.7.2.1.1 |
eriRouterPvcCompliance2The compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB.deprecated Unknown .1.3.6.1.4.1.193.218.2.7.2.1.2 |
eriRouterPvcCompliance3The compliance statement for SNMP entities which implement the ERICSSON-ROUTER-PVC-MIB. Unknown .1.3.6.1.4.1.193.218.2.7.2.1.3 |
eriRouterPvcGroups OBJECT IDENTIFIER .1.3.6.1.4.1.193.218.2.7.2.2 |
eriRouterAtmPvcGroupthe collection of objects which represent the ATM PVC.deprecated Unknown .1.3.6.1.4.1.193.218.2.7.2.2.1 |
eriRouterFrameRelayPvcGroupthe collection of objects which represent the FrameRelay PVC.deprecated Unknown .1.3.6.1.4.1.193.218.2.7.2.2.2 |
eriRouterAtmPvcGroup2The collection of objects which represent the ATM PVC. Unknown .1.3.6.1.4.1.193.218.2.7.2.2.3 |
eriRouterFrameRelayPvcGroup2The collection of objects which represent the FrameRelay PVC. Unknown .1.3.6.1.4.1.193.218.2.7.2.2.4 |
eriRouterDot1qPvcOnEthGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on Ethernet ports. Unknown .1.3.6.1.4.1.193.218.2.7.2.2.5 |
eriRouterDot1qPvcOnAtmGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on ATM circuits. Unknown .1.3.6.1.4.1.193.218.2.7.2.2.6 |
eriRouterDot1qPvcOnFrGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on Frame Relay circuits. Unknown .1.3.6.1.4.1.193.218.2.7.2.2.7 |
eriRouterPvcMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.193.218.2.7.3 |