DellMDStorageArray
The DellMDStorageArray MIB enables SNMP-based monitoring and management of Dell MD Series storage arrays, exposing critical operational metrics such as drive health status, controller redundancy states, and storage pool utilization. This module facilitates the collection of performance counters and alarm conditions to support capacity planning and fault isolation within the storage infrastructure.
Imported Objects
Objects
20 total| Object Name |
|---|
dell OBJECT IDENTIFIER .1.3.6.1.4.1.674 |
storage OBJECT IDENTIFIER .1.3.6.1.4.1.674.10893 |
hardware OBJECT IDENTIFIER .1.3.6.1.4.1.674.10893.2 |
mdStorageManager OBJECT IDENTIFIER .1.3.6.1.4.1.674.10893.2.30 |
dellMDStorageArrayMIBMD Storage Array MIB MODULE-IDENTITY .1.3.6.1.4.1.674.10893.2.30.0 |
storageArrayCriticalThis trap indicates an event where user-interaction is required immediately. Some example events are component failures or critical errors. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10893.2.30.0.1 |
storageArrayWarningThis trap indicates an event where user-interaction may be required. Example are events that put the array in a non-optimal state. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10893.2.30.0.2 |
storageArrayInformationalThis trap indicates a non-failure event of interest where user interaction is generally not required. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10893.2.30.0.3 |
storageArrayDebugThis trap indicates an interal system debug event of interest. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10893.2.30.0.4 |
infoTableInformation for array traps. SEQUENCE OF InfoEntry .1.3.6.1.4.1.674.10893.2.30.1 |
infoEntryThe data for array traps. InfoEntry .1.3.6.1.4.1.674.10893.2.30.1.1 |
deviceHostIPTypeType of IP Address of the network-attached device or device host. 0 unknown, 1 ipv4, 2 ipv6ro InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.674.10893.2.30.1.1.1 |
deviceHostIPAddrIP Address of the network-attached device or device host.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.674.10893.2.30.1.1.2 |
deviceHostNameThe user label for the host of the device being reported on.ro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.3 |
deviceUserLabelThe user label for the device being reported on.ro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.4 |
deviceErrorCodeThe error code as reported by the device or host.ro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.5 |
eventTimeThe time at which the event happen on the device.ro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.6 |
trapDescriptionA string to indicate the nature of the trapro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.7 |
componentTypeA string to identify the failing component typero DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.8 |
componentLocationA string to identify the location of the failing componentro DisplayString .1.3.6.1.4.1.674.10893.2.30.1.1.9 |
More MIBs from Dell