FluidFS-MIB
FluidFS MIB
Main OID:
fluidFSMIBIdentity.1.3.6.1.4.1.674.11000.2000.200.100
1349
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
1349 total| Object Name |
|---|
dell OBJECT IDENTIFIER .1.3.6.1.4.1.674 |
IMPORTS Unknown .1.3.6.1.4.1.674 |
enterpriseSoftware OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000 |
storageMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000 |
fluidFS OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200 |
fluidFSCluster OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.2 |
fluidFSCluNameThe name of the cluster.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.2.1 |
fluidFSCluNodeNameThe name of the node.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.2.4.1.2 |
fluidFSCluResourceNameThe name of the resource. It must be unique within the cluster.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.2.5.1.2 |
fluidFSCluResourceOwnerNodeThe node in the cluster where the group of the resource is
currently online.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.2.5.1.4 |
fluidFSGenEventDescA string describing the general event.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.10 |
fluidFSFileNameThe file name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.11 |
fluidFSEvents OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20 |
fluidFSEventsAdmin OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.1 |
fluidFSEventAdminGeneralFutureTenantScopeEventInfoTenant scope event. Tenant {{TenantName}} (ID={{TenantId}}): {{generalEventText}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.1 |
fluidFSEventAdminGeneralFutureVolumeScopeEventInfoNAS Volume scope event. NAS Volume {{VolumeName}} (ID={{FSID}}): {{generalEventText}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.11 |
fluidFSEventAdminPauseReplicationThe user {{username}} paused the replication from {{replicationSource}} to {{replicationDestination}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.102 |
fluidFSEventAdminResumeReplicationThe user {{username}} resumed the replication from {{replicationSource}} to {{replicationDestination}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.103 |
fluidFSEventAdminStartedImmediateReplicationThe user {{username}} started immediate replication from {{replicationSource}} to {{replicationDestination}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.104 |
fluidFSEventAdminDetachReplicationThe user {{username}} detached the destination NAS volume {{replicationDestination}} from source NAS volume {{replicationSource}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.105 |
fluidFSEventAdminAttachReplicationThe user {{username}} attached the destination NAS volume {{replicationDestinationVolume}}@{{replicationDestinationCluster}} to NAS volume {{replicationSourceVolume}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.106 |
fluidFSEventAdminAddTrustedClusterThe user {{username}} added a new replication partner named {{trustedCluster}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.110 |
fluidFSEventAdminUpdateTrustedClusterConfThe user {{username}} updated the replication partner configuration for {{trustedCluster}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.111 |
fluidFSEventAdminRemoveTrustedClusterThe user {{username}} removed the cluster {{trustedCluster}} from the list of replication partners. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.112 |
fluidFSEventAdminSpInstalled{{packageName}} bundle installation completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.122 |
fluidFSEventAdminServicePackStartedFirmware DellFluidFS-{{spVersion}} installation started Description: Firmware DellFluidFS-{{spVersion}} installation started Action Items: You should follow the installation process in the CLI / WUI and the event log to verify it successfully completes NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.154 |
fluidFSEventAdminServicePackFailedFirmware DellFluidFS-{{spVersion}} failed to install. Description: Firmware DellFluidFS-{{spVersion}} failed to install, reason: {{spError}}. Action Items: System may be in inconsistent state, please check system validation in CLI / WUI.[[nl]]If system is in unstable state (i.e. some controllers are reported down) then escalate to resolve the situation. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.155 |
fluidFSEventAdminServicePackFinishedSuccessfully upgraded to firmware DellFluidFS-{{spVersion}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.156 |
fluidFSEventAdminGeneralFutureEventInfo{{generalEventText}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.162 |
fluidFSEventAdminGeneralFutureEventMajor{{generalEventText}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.163 |
fluidFSEventAdminGeneralFutureEventCrit{{generalEventText}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.164 |
fluidFSEventAdminGeneralFutureEventWarning{{generalEventText}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.165 |
fluidFSEventAdminCancelReplication{{username}} cancelled the replication from {{replicationSource}} to {{replicationDestination}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.167 |
fluidFSEventAdminDisableReplicationReplication-policy of NAS volumes {{replicationSource}} and {{replicationDestination}} was disabled. Description: The user {{username}} disabled the replication-policy of the destination NAS volume {{replicationDestination}} and the source NAS volume {{replicationSource}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.170 |
fluidFSEventAdminEnableReplicationReplication-policy of NAS volumes {{replicationSourceVolume}} and {{replicationDestinationVolume}} was enabled. Description: The user {{username}} enabled replication: re-attached NAS volume {{replicationDestinationVolume}} on cluster {{replicationDestinationCluster}} to local NAS volume {{replicationSourceVolume}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.171 |
fluidFSEventAdminAdminLoggedInToInterfaceThe user {{username}} logged in to {{ui}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.180 |
fluidFSEventAdminFormatFileSystemMkfsFailedFormat failed during execution of File System Structures Initialization phase. Internal Information: mkfs.sh failed with error code {{ErrCode}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.181 |
fluidFSEventAdminIncrementalFormatFileSystemMkfsFailedIncremental Format failed during execution of File System Structures Initialization phase. Internal Information: mkfs.sh failed with error code {{ErrCode}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.182 |
fluidFSEventAdminControllerAutoAttachStartAuto attach of NAS controller {{controllerId}} in appliance {{applianceId}} has started. Action Items: You should follow the attachment process in the CLI / WUI to verify it successfully completes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.185 |
fluidFSEventAdminControllerAutoDetachStartAuto detach of NAS controller {{controllerId}} in appliance {{applianceId}} has started. Action Items: You should follow the detachment process in the CLI / WUI to verify it successfully completes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.186 |
fluidFSEventAdminApplianceCreateStartCreate of NAS Appliance {{applianceId}} ({{applianceServiceTag}}) has started. Action Items: You should follow the appliance create process in the CLI / WUI to verify it successfully completes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.187 |
fluidFSEventAdminEnableEscalationAccessEscalation access was enabled for {{escalationPeriodInMinutes}} minutes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.188 |
fluidFSEventAdminConfigurationObjectSoftLimitExceededUser {{username}} created {{objectName}} exceeding the maximum recommended count {{recommendedMaxCount}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.189 |
fluidFSEventAdminControllerAttachStartAttach of NAS controller {{controllerId}} has started by {{username}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.190 |
fluidFSEventAdminControllerAttachEndAttach of NAS controller {{controllerId}} has completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.191 |
fluidFSEventAdminControllerDetachStartDetach of NAS controller {{controllerId}} was started by {{username}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.192 |
fluidFSEventAdminControllerDetachEndDetach of NAS controller {{controllerId}} has completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.193 |
fluidFSEventAdminApplianceJoinStartJoin of NAS Appliance {{applianceId}} was started by {{username}}. Action Items: You should follow the appliance join process in the CLI / WUI to verify it successfully completes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.194 |
fluidFSEventAdminApplianceJoinEndJoin of NAS Appliance {{applianceId}} has completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.1.195 |
fluidFSEventsHardware OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.2 |
fluidFSEventHardwareNoPacketLossInSubnetHostNAS Controller {{nodeId}} has no packet loss to host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.1 |
fluidFSEventHardwarePacketLossInSubnetNAS Controller {{nodeId}} had packet loss to {{subnetName}}. Description: NAS Controller {{nodeId}} had {{packetLoss}}% packet loss to IP address {{subnetName}} on host {{hostName}}. Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.4 |
fluidFSEventHardwareNoPacketLossInSubnetNAS Controller {{nodeId}} has no packet loss on {{subnetName}}. Description: NAS Controller {{nodeId}} has no packet loss to IP address {{subnetName}} on host {{hostName}}. Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.6 |
fluidFSEventHardwareNoPacketLossJumboInSubnetHostNAS Controller {{nodeId}} has no packet loss (using jumbo frames) to host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.7 |
fluidFSEventHardwarePacketLossJumboInSubnetNAS Controller {{nodeId}} had jumbo packet loss. Description: NAS Controller {{nodeId}} had {{packetLoss}}% packet loss to IP address {{subnetName}} on host {{hostName}} (using jumbo frames). Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.8 |
fluidFSEventHardwareNoPacketLossJumboInSubnetNAS Controller {{nodeId}} has no jumbo packet loss. Description: NAS Controller {{nodeId}} has no packet loss to IP address {{subnetName}} on host {{hostName}} (using jumbo frames). Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.12 |
fluidFSEventHardwareCantReachSubnetNAS Controller {{nodeId}} cannot reach IP {{subnetName}} Description: NAS Controller {{nodeId}} cannot reach IP address {{subnetName}} on host {{hostName}}. Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.13 |
fluidFSEventHardwareCantReachJumboSubnetNAS Controller {{nodeId}} cannot reach IP using (jumbo frames) Description: NAS Controller {{nodeId}} cannot reach IP address {{subnetName}} on host {{hostName}} (using jumbo frames). Subnet identifier {{network_id}}, prefix {{prefix}}, vlan tag id {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.18 |
fluidFSEventHardwareEthHasErrors{{ethName}} (part of {{bondName}}) on NAS Controller {{nodeId}} has errors. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.35 |
fluidFSEventHardwareEthHasDrops{{ethName}} (part of {{bondName}}) on NAS Controller {{nodeId}} has drops. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.36 |
fluidFSEventHardwareCantReachDefaultGatewayNAS Controller{{nodeId}} cannot reach default gateway {{ip}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.38 |
fluidFSEventHardwareCanReachDefaultGatewayNAS Controller{{nodeId}} can reach default gateway {{ip}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.39 |
fluidFSEventHardwarePacketLossInSubnetHostNAS Controller {{nodeId}} had {{packetLoss}}% packet loss to host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.56 |
fluidFSEventHardwareNoLinkInEthOnControllerEth{{ethName}} which belongs to NAS Controller {{nodeId}} is down. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.57 |
fluidFSEventHardwareEthLinkRestoredOnControllerEth{{ethName}} which belongs to NAS Controller {{nodeId}} is restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.58 |
fluidFSEventHardwarePacketLossJumboInSubnetHostNAS Controller {{nodeId}} had {{packetLoss}}% packet loss (using jumbo frames) to host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.59 |
fluidFSEventHardwareCantReachSubnetHostNAS Controller {{nodeId}} cannot reach host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.60 |
fluidFSEventHardwareCantReachJumboSubnetHostNAS Controller {{nodeId}} cannot reach (using jumbo frames) host {{hostName}} on {{subnetName}} subnet. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.61 |
fluidFSEventHardwareBpsAccessibilityNormalNAS Controller{{nodeId}} BPS reachability is back to normal (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.109 |
fluidFSEventHardwareBpsNormalBPS on NAS Controller{{nodeId}} is back to normal operation. Charge is {{bpsBatteryCharge}}% (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.110 |
fluidFSEventHardwareProcessorCoresCountFailedFailed to validate CPU cores count is equal in NAS Controller {{firstNodeId}} and NAS Controller {{secondNodeId}} (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.120 |
fluidFSEventHardwareProcessorCoresCountOkCPU cores count test successful. Count is equal in NAS Controller {{firstNodeId}} and NAS Controller {{secondNodeId}} (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.121 |
fluidFSEventHardwareMemoryNotOptimalMemory device status in NAS Controller{{nodeId}} is not optimal (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.124 |
fluidFSEventHardwareMemoryErrorMemory device status in NAS Controller{{nodeId}} is critical (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.125 |
fluidFSEventHardwareMemoryBackToNormalMemory device in NAS Controller{{nodeId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.126 |
fluidFSEventHardwareMemoryTempWarnMemory device temperature sensors in NAS Controller{{nodeId}} report warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.127 |
fluidFSEventHardwareMemoryTempNormalMemory device temperature sensors in NAS Controller{{nodeId}} report normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.128 |
fluidFSEventHardwareMemoryTempCriticalMemory device temperature sensors in NAS Controller{{nodeId}} report critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.129 |
fluidFSEventHardwareMemorySizeCountFailedFailed to validate memory size is equal in NAS Controller {{firstNodeId}} and NAS Controller {{secondNodeId}} (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.130 |
fluidFSEventHardwareMemorySizeCountOkMemory size test successful. Size is equal in NAS Controller {{firstNodeId}} and NAS Controller {{secondNodeId}} (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.131 |
fluidFSEventHardwareMemoryInfoNotAvailableMemory device status in NAS Controller{{nodeId}} is not available. Internal error in memory monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.132 |
fluidFSEventHardwareMemoryInfoIsAvailableMemory device status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.133 |
fluidFSEventHardwareControllerStatusNotAvailableNAS Controller{{nodeId}} hardware status is not available. Internal error in controller status analysis (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.135 |
fluidFSEventHardwareControllerStatusAvailableNAS Controller{{nodeId}} hardware status is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.136 |
fluidFSEventHardwareLocalDisksInfoNotAvailableLocal storage status in NAS Controller{{nodeId}} is not available. S.M.A.R.T. info is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.143 |
fluidFSEventHardwareLocalDisksInfoIsAvailableLocal storage status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.144 |
fluidFSEventHardwareApplianceIntrusionWarningChassis cover for NAS Appliance{{applianceId}} is open (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.153 |
fluidFSEventHardwareApplianceIntrusionOkChassis cover for NAS Controller {{applianceId}} was closed (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.154 |
fluidFSEventHardwareAppFanSystemInfoNotAvailableFans set overall status in NAS Appliance {{applianceId}} is not available. Internal error in fans monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.168 |
fluidFSEventHardwareAppFanSystemInfoIsAvailableFans set overall status in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.169 |
fluidFSEventHardwareAppFanErrorFan {{componentName}} in NAS Appliance {{applianceId}} has critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.170 |
fluidFSEventHardwareAppFanWarningFan {{componentName}} in NAS Appliance {{applianceId}} has warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.171 |
fluidFSEventHardwareAppFanBackToNormalFan {{componentName}} in NAS Appliance {{applianceId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.172 |
fluidFSEventHardwareAppFanInfoNotAvailableFan {{componentName}} status in NAS Appliance {{applianceId}} is not available. Internal error in fans monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.173 |
fluidFSEventHardwareAppFanInfoIsAvailableFan {{componentName}} status in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.174 |
fluidFSEventHardwarePowerSupplyInfoNotAvailablePower supply status in NAS Controller{{nodeId}} is not available. Internal error in power supply monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.178 |
fluidFSEventHardwarePowerSupplyInfoIsAvailablePower supply status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.179 |
fluidFSEventHardwarePsuErrorPower supply unit {{componentName}} in NAS Controller{{nodeId}} has failure status, power supply redundancy lost (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.180 |
fluidFSEventHardwarePsuWarningPower supply unit {{componentName}} in NAS Controller{{nodeId}} has warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.181 |
fluidFSEventHardwarePsuBackToNormalPower supply unit {{componentName}} in NAS Controller{{nodeId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.182 |
fluidFSEventHardwarePsuInfoNotAvailablePower supply unit {{componentName}} status in NAS Controller{{nodeId}} is not available. Internal error in power supply monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.183 |
fluidFSEventHardwarePsuInfoIsAvailablePower supply unit {{componentName}} status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.184 |
fluidFSEventHardwareAppPowerSupplyInfoNotAvailablePower supply status in NAS Appliance {{applianceId}} is not available. Internal error in power supply monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.188 |
fluidFSEventHardwareAppPowerSupplyInfoIsAvailablePower supply status in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.189 |
fluidFSEventHardwareAppPsuErrorPower supply unit {{componentName}} in NAS Appliance {{applianceId}} has failure status, power supply redundancy lost (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.190 |
fluidFSEventHardwareAppPsuWarningPower supply unit {{componentName}} in NAS Appliance {{applianceId}} has warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.191 |
fluidFSEventHardwareAppPsuBackToNormalPower supply unit {{componentName}} in NAS Appliance {{applianceId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.192 |
fluidFSEventHardwareAppPsuInfoNotAvailablePower supply unit {{componentName}} status in NAS Appliance {{applianceId}} is not available. Internal error in power supply monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.193 |
fluidFSEventHardwareAppPsuInfoIsAvailablePower supply unit {{componentName}} status in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.194 |
fluidFSEventHardwareAppPsuAmperageErrorCurrent sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.195 |
fluidFSEventHardwareAppPsuAmperageWarningCurrent sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.196 |
fluidFSEventHardwareAppPsuAmperageNormalCurrent sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports normal status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.197 |
fluidFSEventHardwareAppPsuTempErrorTemperature sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.201 |
fluidFSEventHardwareAppPsuTempWarningTemperature sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.202 |
fluidFSEventHardwareAppPsuTempNormalTemperature sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.203 |
fluidFSEventHardwareAppPsuVoltageErrorVoltage sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.207 |
fluidFSEventHardwareAppPsuVoltageWarningVoltage sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.208 |
fluidFSEventHardwareAppPsuVoltageNormalVoltage sensor in power supply unit {{componentName}} in NAS Appliance {{applianceId}} reports normal status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.209 |
fluidFSEventHardwareMotherBoardAmperageErrorNAS Controller{{nodeId}} system board current sensors report critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.213 |
fluidFSEventHardwareMotherBoardAmperageWarningNAS Controller{{nodeId}} system board current sensors report warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.214 |
fluidFSEventHardwareMotherBoardAmperageNormalNAS Controller{{nodeId}} system board current sensors report normal status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.215 |
fluidFSEventHardwareMotherBoardTempErrorNAS Controller{{nodeId}} system board temperature sensors report critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.216 |
fluidFSEventHardwareMotherBoardTempWarningNAS Controller{{nodeId}} system board temperature sensors report warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.217 |
fluidFSEventHardwareMotherBoardTempNormalNAS Controller{{nodeId}} system board temperature sensors report normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.218 |
fluidFSEventHardwareMotherBoardVoltageErrorNAS Controller{{nodeId}} system board voltage sensors report critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.219 |
fluidFSEventHardwareMotherBoardVoltageWarningNAS Controller{{nodeId}} system board voltage sensors report warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.220 |
fluidFSEventHardwareMotherBoardVoltageNormalNAS Controller{{nodeId}} system board voltage sensors report normal status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.221 |
fluidFSEventHardwareMotherBoardInfoNotAvailableController system board status in NAS Controller{{nodeId}} is not available. Internal error in system board monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.222 |
fluidFSEventHardwareMotherBoardInfoIsAvailableController system board status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.223 |
fluidFSEventHardwareNetworksInfoNotAvailableNetwork status in NAS Controller{{nodeId}} is not available. Internal error in network monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.224 |
fluidFSEventHardwareNetworksInfoIsAvailableNetwork status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.225 |
fluidFSEventHardwareNetworkInfoNotAvailable{{networkName}} network status in NAS Controller{{nodeId}} is not available. Internal error in network monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.229 |
fluidFSEventHardwareNetworkInfoIsAvailable{{networkName}} network status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.230 |
fluidFSEventHardwareApplianceStatusNotAvailableNAS Appliance {{applianceId}} hardware status is not available. Internal error in appliance status analysis (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.240 |
fluidFSEventHardwareApplianceStatusAvailableNAS Appliance {{applianceId}} hardware status is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.241 |
fluidFSEventHardwareLocalIPMIBackToNormalNAS Controller{{nodeId}} IPMI is back to normal (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.245 |
fluidFSEventHardwarePeerIPMIBackToNormalNAS Controller{{nodeId}} peer IPMI is reachable again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.246 |
fluidFSEventHardwareLocalIPMIStatusNotAvailableNAS Controller{{nodeId}} local IPMI status is not available. Internal error in IPMI status monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.247 |
fluidFSEventHardwareLocalIPMIStatusAvailableNAS Controller{{nodeId}} local IPMI status is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.248 |
fluidFSEventHardwarePeerIPMIStatusNotAvailableNAS Controller{{nodeId}} peer IPMI status is not available. Internal error in IPMI status monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.249 |
fluidFSEventHardwarePeerIPMIStatusAvailableNAS Controller{{nodeId}} peer IPMI status is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.250 |
fluidFSEventHardwarePsuNotDetectedPower supply unit {{componentName}} in NAS Controller{{nodeId}} is not detected, power supply redundancy lost. Please make sure the unit is attached properly (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.251 |
fluidFSEventHardwarePsuDetectedPower supply unit {{componentName}} in NAS Controller{{nodeId}} is detected (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.252 |
fluidFSEventHardwareAppPsuNotDetectedPower supply unit {{componentName}} in NAS Appliance {{applianceId}} is not detected, power supply redundancy lost. Please make sure the unit is attached properly (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.253 |
fluidFSEventHardwareAppPsuDetectedPower supply unit {{componentName}} in NAS Appliance {{applianceId}} is detected (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.254 |
fluidFSEventHardwareBpsNotAccessibleNAS Controller{{nodeId}} failed to reach its BPS (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.257 |
fluidFSEventHardwareNoLinkInReplicationRelatedEthOnControllerEth{{ethName}} which belongs to NAS Controller{{nodeId}} is down, therefore replication related connectivity may be affected. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.258 |
fluidFSEventHardwarePsuNoInputPower supply unit {{componentName}} in NAS Controller{{nodeId}} has no input. Please make sure the unit cable is attached properly (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.259 |
fluidFSEventHardwarePsuInputDetectedPower supply unit {{componentName}} in NAS Controller{{nodeId}} input detected (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.260 |
fluidFSEventHardwareAppPsuNoInputPower supply unit {{componentName}} in NAS Appliance {{applianceId}} has no input. Please make sure the unit cable is attached properly (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.261 |
fluidFSEventHardwareAppPsuInputDetectedPower supply unit {{componentName}} in NAS Appliance {{applianceId}} input detected (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.262 |
fluidFSEventHardwarePeerIPMIReachabilityNAS Controller{{nodeId}} cannot reach peer IPMI (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.264 |
fluidFSEventHardwareLocalIPMIReachabilityNAS Controller{{nodeId}} IPMI is not working (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.265 |
fluidFSEventHardwareChassisIntrusionAlertChassis cover for NAS Controller{{nodeId}} is open (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.267 |
fluidFSEventHardwareChassisIntrusionBackToNormalChassis cover for NAS Controller{{nodeId}} was closed (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.268 |
fluidFSEventHardwareBpsCalibrationCycleNotAvailableBattery Calibration Cycle status in NAS Controller{{nodeId}} is not available. Internal error in Battery monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.269 |
fluidFSEventHardwareBpsCalibrationCycleIsAvailableBattery Calibration Cycle status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.270 |
fluidFSEventHardwareBpsCalibrationCycleInProgressBattery Calibration Cycle is in progress. Description: A Battery Calibration Cycle in NAS Controller{{nodeId}} is in progress. The Battery Pack will go through charge and discharge cycles, therefore battery error events during this process are normal. This process may take up to 7 days from first notification to complete. (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.271 |
fluidFSEventHardwareBpsForcedCalibrationCyclePendingForced BPS Calibration pending, performance impact expected. Description: Calibration Cycle will be forced in 30 days from first notification. Could not perform normal battery calibration cycle in NAS Controller{{nodeId}} since peer controller battery is not in an optimal condition. If peer battery is not repaired before the Calibration Cycle is forced, then during portions of the Calibration Cycle the file system will move to journaling mode, which may cause a performance impact (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.272 |
fluidFSEventHardwareBpsForcedCalibrationCycleNotNeededThe Forced Battery Calibration Cycle in NAS Controller{{nodeId}} is no longer required (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.273 |
fluidFSEventHardwareBpsCalibrationCycleIdleThe Battery Calibration Cycle in NAS Controller{{nodeId}} is idle (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.274 |
fluidFSEventHardwareBpsCalibrationLowBatteryBPS on NAS Controller{{nodeId}} is not operating properly. This is expected as the battery is under calibration cycle. Charge is {{bpsBatteryCharge}}% (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.275 |
fluidFSEventHardwareStandardFrameDisconnected{{ethName}} on NAS Controller{{firstNodeId}} cannot access {{targetEthName}} on NAS Controller{{secondNodeId}} (service tag: {{contextBasedServiceTag}}). Check that these interfaces are connected to the same switch, and are properly tagged. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.276 |
fluidFSEventHardwareStandardFrameConnected{{ethName}} on NAS Controller{{firstNodeId}} can access {{targetEthName}} on NAS Controller{{secondNodeId}} (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.277 |
fluidFSEventHardwareLargeFrameLDisconnected{{ethName}} on NAS Controller{{firstNodeId}} cannot access {{targetEthName}} on NAS Controller{{secondNodeId}} using large frames (service tag: {{contextBasedServiceTag}}). Check that jumbo-frames are enabled for these interfaces in the switch. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.278 |
fluidFSEventHardwareLargeFrameConnected{{ethName}} on NAS Controller {{firstNodeId}} can access {{targetEthName}} on NAS Controller {{secondNodeId}} using large frames (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.279 |
fluidFSEventHardwareBpsLowBatteryBPS charge on NAS Controller{{nodeId}} is too low ({{bpsBatteryCharge}}%). BPS is not operating properly (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.282 |
fluidFSEventHardwareExtServerJumboFramePacketLossNAS Controller{{nodeId}} had {{packetLoss}}% packet loss to {{extSrvType}} {{ip}}. Please make sure the {{extSrvType}} allows jumbo frames. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.283 |
fluidFSEventHardwareCantReachExtServeJumboFrameNAS Controller{{nodeId}} cannot reach {{extSrvType}} {{ip}}. Please make sure the {{extSrvType}} allows jumbo frames. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.284 |
fluidFSEventHardwareCantReachStaticRouteNAS Controller{{nodeId}} cannot reach the gateway {{ip}} to network {{destinationNetwork}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.285 |
fluidFSEventHardwareCanReachStaticRouteNAS Controller{{nodeId}} can reach the gateway {{ip}} to network {{destinationNetwork}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.286 |
fluidFSEventHardwareClusterCantSeeAllFormattedLunsFluidFS cannot access any formatted LUN. Please make sure the backend storage is on and appropriately connected to FluidFS. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.287 |
fluidFSEventHardwareClusterSeesAllFormattedLunsFluidFS connection to all the formatted LUNs is fully restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.288 |
fluidFSEventHardwareNodeCantSeeFormattedLunsMajorNAS Controller{{nodeId}} cannot reach all the formatted LUNs. The system may not be serving. Please make sure that this Controller is properly connected to a storage. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.289 |
fluidFSEventHardwareNodeCantSeeFormattedLunsWarningNAS Controller{{nodeId}} cannot reach all the formatted LUNs. The performance may be degraded. Please make sure that this Controller is properly connected to a storage. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.290 |
fluidFSEventHardwareNodeSeesFormattedLunsNAS Controller{{nodeId}} restored connection to all the formatted LUNs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.291 |
fluidFSEventHardwareClusterCantSeeFormattedLunLUN {{lunId}} is not reachable from FluidFS. Please make sure the LUN exists and is properly mapped from the backend storage. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.292 |
fluidFSEventHardwareClusterSeesFormattedLunLUN {{lunId}} is now fully reachable from FluidFS. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.293 |
fluidFSEventHardwareNodeCantSeeLunMajorFluidFS Controller{{nodeId}} can not reach formatted LUN {{lunId}}. The system may not be serving. Please check that this LUN has appropriate permissions to be seen by this FluidFS Controller. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.294 |
fluidFSEventHardwareNodeCantSeeLunWarningFluidFS Controller{{nodeId}} can not reach formatted LUN {{lunId}}. The performance may be degraded. Please check that this LUN has appropriate permissions to be seen by this FluidFS Controller. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.295 |
fluidFSEventHardwareMeshDisconnectednode{{fromNode}}.{{fromEth}} cannot reach node{{toNode}}.{{toEth}} in vlan {{vlanTag}} Description: {{fromEth}} on NAS Controller{{fromNode}} cannot access {{toEth}} on NAS Controller{{toNode}} with vlan tag {{vlanTag}}. Action Items: Check that these interfaces are connected to the same switch, and are properly tagged. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.296 |
fluidFSEventHardwareMeshConnectednode{{fromNode}}.{{fromEth}} can reach node{{toNode}}.{{toEth}} in vlan {{vlanTag}} Description: {{fromEth}} on NAS Controller{{fromNode}} can access {{toEth}} on NAS Controller{{toNode}} with vlan tag {{vlanTag}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.297 |
fluidFSEventHardwareTapeDeviceNotAccessibleFromNodeTape device {{tapeName}} is not accessible from NAS Controller{{nodeId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.298 |
fluidFSEventHardwareTapeDeviceNotAccessibleFromAllNodesTape device {{tapeName}} is not accessible from all NAS Controllers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.299 |
fluidFSEventHardwareTapeDeviceAccessibleFromNodeTape device {{tapeName}} is accessible from NAS Controller{{nodeId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.300 |
fluidFSEventHardwareDifferentFcHbaSpeedOnControllerFibre Channel port speeds in NAS Controller{{nodeId}} are not identical. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.301 |
fluidFSEventHardwareBpsAccessibilityNotAvailableBPS reachability in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.302 |
fluidFSEventHardwareBpsAccessibilityIsAvailableBPS reachability in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.303 |
fluidFSEventHardwareBpsInfoNotAvailableBPS status info in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.304 |
fluidFSEventHardwareBpsInfoIsAvailableBPS status info in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.305 |
fluidFSEventHardwareProcessorNotOptimalProcessor {{cpuName}} status in NAS Controller{{nodeId}} is not optimal (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.306 |
fluidFSEventHardwareProcessorErrorProcessor {{cpuName}} status in NAS Controller{{nodeId}} is critical (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.307 |
fluidFSEventHardwareProcessorBackToNormalProcessor {{cpuName}} in NAS Controller{{nodeId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.308 |
fluidFSEventHardwareProcessorTempNotAvailableProcessor {{cpuName}} temprature sensor info in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.309 |
fluidFSEventHardwareProcessorTempIsAvailableProcessor {{cpuName}} temprature sensor info in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.310 |
fluidFSEventHardwareProcessorTempWarnProcessor {{cpuName}} temperature sensor in NAS Controller{{nodeId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.311 |
fluidFSEventHardwareProcessorTempNormalProcessor {{cpuName}} temperature sensors in NAS Controller{{nodeId}} report normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.312 |
fluidFSEventHardwareProcessorTempCriticalProcessor {{cpuName}} temperature sensors in NAS Controller{{nodeId}} report critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.313 |
fluidFSEventHardwareProcessorVoltageNotAvailableProcessor {{cpuName}} voltage sensor info in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.314 |
fluidFSEventHardwareProcessorVoltageIsAvailableProcessor {{cpuName}} voltage sensor info in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.315 |
fluidFSEventHardwareProcessorVoltageWarnProcessor {{cpuName}} voltage sensors in NAS Controller{{nodeId}} report warning status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.316 |
fluidFSEventHardwareProcessorVoltageNormalProcessor {{cpuName}} voltage sensors in NAS Controller{{nodeId}} report normal status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.317 |
fluidFSEventHardwareProcessorVoltageCriticalProcessor {{cpuName}} voltage sensors in NAS Controller{{nodeId}} report critical status (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.318 |
fluidFSEventHardwareProcessorInfoNotAvailableProcessor {{cpuName}} status in NAS Controller{{nodeId}} is not available. Internal error in processor monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.319 |
fluidFSEventHardwareProcessorInfoIsAvailableProcessor {{cpuName}} status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.320 |
fluidFSEventHardwareProcessorDisabledProcessor {{cpuName}} in NAS Controller{{nodeId}} is disabled (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.321 |
fluidFSEventHardwareProcessorEnabledProcessor {{cpuName}} in NAS Controller{{nodeId}} is enabled again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.322 |
fluidFSEventHardwareMemoryTempNotAvailableMemory device temperature sensors info in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.323 |
fluidFSEventHardwareMemoryTempIsAvailableMemory device temperature sensors info in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.324 |
fluidFSEventHardwareBpsErrorBPS on Controller{{nodeId}} (service tag: {{contextBasedServiceTag}}) is not operating properly - battery reports failed state (charge: {{bpsBatteryCharge}}%). Description: BPS on NAS Controller{{nodeId}} (service tag: {{contextBasedServiceTag}}) is not operating properly - battery reports failed state (charge: {{bpsBatteryCharge}}%). This could be the result of a recent calibration process - if you receive this event again after a few days for this specific controller, please contact Support. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.325 |
fluidFSEventHardwareLocalDiskWearingOutLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} is wearing out. Consider disk replacement. Overall reads/writes: {{diskOverallReads}} / {{diskOverallWrites}} MB. (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.326 |
fluidFSEventHardwareLocalDiskLotOfBadSectorsLocal disk {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} has a lot of bad sectors. Consider disk replacement. Bad sectors count: {{badSectorsCount}} (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.327 |
fluidFSEventHardwareLocalDiskBadSectorsCountLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} bad sectors count: {{badSectorsCount}} (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.328 |
fluidFSEventHardwareLocalDiskLotOfFailedWritesLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} has a lot of failed writes. Consider disk replacement. Failed writes count: {{failedWritesCount}} (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.329 |
fluidFSEventHardwareLocalDiskFailedWritesCountLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} failed writes count: {{failedWritesCount}} (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.330 |
fluidFSEventHardwareLocalDiskBadS.M.A.R.T. self test is failed for local storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}}. Disk may need a replacement. (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.331 |
fluidFSEventHardwareLocalDiskBackToNormalLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) in NAS Controller{{nodeId}} returned to normal operation (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.332 |
fluidFSEventHardwareLocalDiskModelNotSupportedLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) is not supported in NAS Controller{{nodeId}}. Disk monitoring may not work properly. Suppoerted modles are: {{supportedModels}}. (service tag: {{contextBasedServiceTag}}) NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.333 |
fluidFSEventHardwareLocalDiskInfoNotAvailableLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) status in NAS Controller{{nodeId}} is not available. Internal error in local storage monitoring (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.334 |
fluidFSEventHardwareLocalDiskInfoIsAvailableLocal storage disk drive {{diskName}} (Model: {{diskModel}}; Serial: {{diskSerial}}) status in NAS Controller{{nodeId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.335 |
fluidFSEventHardwareApplianceIntrusionNotAvailableIntrusion info for NAS Appliance{{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.336 |
fluidFSEventHardwareApplianceIntrusionIsAvailableIntrusion info for NAS Appliance{{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.337 |
fluidFSEventHardwareAppPsuAmperageNotAvailableCurrent sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.338 |
fluidFSEventHardwareAppPsuAmperageIsAvailableCurrent sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.339 |
fluidFSEventHardwareAppPsuTempNotAvailableTemperature sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.340 |
fluidFSEventHardwareAppPsuTempIsAvailableTemperature sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.341 |
fluidFSEventHardwareAppPsuVoltageNotAvailableVoltage sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.342 |
fluidFSEventHardwareAppPsuVoltageIsAvailableVoltage sensor info in power supply unit {{componentName}} in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.343 |
fluidFSEventHardwareAppTopControllerTempNotAvailableTemperature sensor info in top controller in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.344 |
fluidFSEventHardwareAppTopControllerTempIsAvailableTemperature sensor info in top controller in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.345 |
fluidFSEventHardwareAppTopControllerTempNormalTemperature sensor in top controller in NAS Appliance {{applianceId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.346 |
fluidFSEventHardwareAppTopControllerTempWarningTemperature sensor in top controller in NAS Appliance {{applianceId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.347 |
fluidFSEventHardwareAppTopControllerTempErrorTemperature sensor in top controller in NAS Appliance {{applianceId}} reports critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.348 |
fluidFSEventHardwareAppBottomControllerTempNotAvailableTemperature sensor info in bottom controller in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.349 |
fluidFSEventHardwareAppBottomControllerTempIsAvailableTemperature sensor info in bottom controller in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.350 |
fluidFSEventHardwareAppBottomControllerTempNormalTemperature sensor in bottom controller in NAS Appliance {{applianceId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.351 |
fluidFSEventHardwareAppBottomControllerTempWarningTemperature sensor in bottom controller in NAS Appliance {{applianceId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.352 |
fluidFSEventHardwareAppBottomControllerTempErrorTemperature sensor in bottom controller in NAS Appliance {{applianceId}} reports critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.353 |
fluidFSEventHardwareAppLeftRaiserCardTempNotAvailableTemperature sensor info in left raiser card in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.354 |
fluidFSEventHardwareAppLeftRaiserCardTempIsAvailableTemperature sensor info in left raiser card in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.355 |
fluidFSEventHardwareAppLeftRaiserCardTempNormalTemperature sensor in left raiser card in NAS Appliance {{applianceId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.356 |
fluidFSEventHardwareAppLeftRaiserCardTempWarningTemperature sensor in left raiser card in NAS Appliance {{applianceId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.357 |
fluidFSEventHardwareAppLeftRaiserCardTempErrorTemperature sensor in left raiser card in NAS Appliance {{applianceId}} reports critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.358 |
fluidFSEventHardwareAppRightRaiserCardTempNotAvailableTemperature sensor info in right raiser card in NAS Appliance {{applianceId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.359 |
fluidFSEventHardwareAppRightRaiserCardTempIsAvailableTemperature sensor info in right raiser card in NAS Appliance {{applianceId}} is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.360 |
fluidFSEventHardwareAppRightRaiserCardTempNormalTemperature sensor in right raiser card in NAS Appliance {{applianceId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.361 |
fluidFSEventHardwareAppRightRaiserCardTempWarningTemperature sensor in right raiser card in NAS Appliance {{applianceId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.362 |
fluidFSEventHardwareAppRightRaiserCardTempErrorTemperature sensor in right raiser card in NAS Appliance {{applianceId}} reports critical status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.363 |
fluidFSEventHardwareMotherBoardAmperageNotAvailableNAS Controller{{nodeId}} system board current sensors info is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.364 |
fluidFSEventHardwareMotherBoardAmperageIsAvailableNAS Controller{{nodeId}} system board current sensors info is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.365 |
fluidFSEventHardwareMotherBoardTempNotAvailableNAS Controller{{nodeId}} system board temprature sensors info is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.366 |
fluidFSEventHardwareMotherBoardTempIsAvailableNAS Controller{{nodeId}} system board temprature sensors info is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.367 |
fluidFSEventHardwareMotherBoardVoltageNotAvailableNAS Controller{{nodeId}} system board voltage sensors info is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.368 |
fluidFSEventHardwareMotherBoardVoltageIsAvailableNAS Controller{{nodeId}} system board voltage sensors info is available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.369 |
fluidFSEventHardwareNetworkInterfaceDown{{networkName}} network interface {{ethName}} in NAS Controller{{nodeId}} is down. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.370 |
fluidFSEventHardwareNetworkInterfaceBackUp{{networkName}} network interface {{ethName}} in NAS Controller{{nodeId}} is back up. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.371 |
fluidFSEventHardwareNetworkInterfaceUnknown{{networkName}} network interface {{ethName}} in NAS Controller{{nodeId}} has unknown status. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.372 |
fluidFSEventHardwareFibreChannelPortDownFibre Channel port {{ethName}} in NAS Controller{{nodeId}} is down. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.373 |
fluidFSEventHardwareFibreChannelPortUpFibre Channel port {{ethName}} in NAS Controller{{nodeId}} is back up. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.374 |
fluidFSEventHardwareFibreChannelPortUnknownFibre Channel port {{ethName}} in NAS Controller{{nodeId}} has unknown status. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.375 |
fluidFSEventHardwareSameFcHbaSpeedOnControllerFibre Channel port speeds in NAS Controller{{nodeId}} are identical again. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.376 |
fluidFSEventHardwareSameEthSpeedOnNetworkNodeEth speeds on {{networkName}} network in NAS Controller{{nodeId}} are identical again. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.377 |
fluidFSEventHardwareAllIfsAreDownAll {{subnetName}} network interfaces on NAS Controller{{nodeId}} are down. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.378 |
fluidFSEventHardwareEthSpeedOnSubnetNodeNotEqualEth speeds on {{subnetName}} network in NAS Controller{{nodeId}} are not identical. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.379 |
fluidFSEventHardwareBpsTempNotAvailableBPS temperature sensor info in NAS Controller{{nodeId}} is not available (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.380 |
fluidFSEventHardwareBpsTempIsAvailableBPS temperature sensor info in NAS Controller{{nodeId}} is not available again (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.381 |
fluidFSEventHardwareBpsTempNormalTemperature sensor in BPS in NAS Controller{{nodeId}} reports normal status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.382 |
fluidFSEventHardwareBpsTempWarningTemperature sensor in BPS in NAS Controller{{nodeId}} reports warning status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.383 |
fluidFSEventHardwareBpsTempErrorTemperature sensor in BPS in NAS Controller{{nodeId}} reports error status (Ambient temperature: {{temperature}} degrees Celsius) (service tag: {{contextBasedServiceTag}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.384 |
fluidFSEventHardwarePSUfirmwareUpgradeFailFirmware upgarade for {{id}} failed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.385 |
fluidFSEventHardwarePSUfirmwareUpgradeSuccessFirmware upgrade for {{id}} finished successfuly NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.386 |
fluidFSEventHardwareUnsupportedNicUnsupported card installed on Controller{{nodeId}}. Description: An unsupported PCI card was detected in slot {{pciSlot}} on NAS Controller{{nodeId}}: {{pciCard}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.2.387 |
fluidFSEventsNdmp OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.3 |
fluidFSEventNdmpNdmpError{{Detail}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.6 |
fluidFSEventNdmpNdmpWarn{{Detail}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.7 |
fluidFSEventNdmpNdmpInfo{{Detail}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.8 |
fluidFSEventNdmpAuthenticationFailureFailed to authenticate: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.9 |
fluidFSEventNdmpBackupStartedThe backup session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} started. Description: The backup session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} started. The source path is {{Path}} and it is executed on controller {{ExecutedOnNode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.10 |
fluidFSEventNdmpBackupFinishedThe backup session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} finished. Description: The backup session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} finished. The source path is {{Path}} and it is executed on controller {{ExecutedOnNode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.11 |
fluidFSEventNdmpRestoreStartedThe restore session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} started. Description: The restore session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} started. The target path is {{Path}} and it is executed on controller {{ExecutedOnNode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.12 |
fluidFSEventNdmpRestoreFinishedThe restore session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} finished. Description: The restore session by ID {{SessionId}} initiated by DMA {{InitiatorDMAServer}} on {{StartTimestamp}} finished. The target path is {{Path}} and it is executed on controller {{ExecutedOnNode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.13 |
fluidFSEventNdmpSessionFailedThe session by ID {{SessionId}} failed: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.14 |
fluidFSEventNdmpSessionTerminatedThe session by ID {{SessionId}} was terminated: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.15 |
fluidFSEventNdmpConfigurationValidationErrorFailed to validate configuration: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.16 |
fluidFSEventNdmpIOErrorIO error: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.17 |
fluidFSEventNdmpNetworkErrorNetwork error: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.18 |
fluidFSEventNdmpSnapshotErrorSnapshot error: {{Detail}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.3.19 |
fluidFSEventsQuota OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.4 |
fluidFSEventQuotaSystemFreeSpaceThresholdExceededLow system available space. Description: System available space is less than {{systemThreshold}}. Action Items: Add more storage to your system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.7 |
fluidFSEventQuotaSystemUsedSpaceThresholdExceededSystem usage is higher than {{systemThreshold}}%. Description: System usage is higher than threshold {{systemThreshold}}% of system capacity {{systemCapacity}}. Action Items: Add more storage to your system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.8 |
fluidFSEventQuotaSystemLeakageBufferThresholdExceededInternal storage reservation is running low. Description: Internal storage reservation is running low. The system capacity is {{systemCapacity}}. Please contact Support. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.10 |
fluidFSEventQuotaSystemOutOfFreeSpaceSystem is out of available space. Description: System is out of available space. Action Items: Add more storage to your system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.13 |
fluidFSEventQuotaSystemUsedSpaceOverwhelmedSystem usage reached system capacity of {{systemCapacity}}. Description: System usage reached system capacity of {{systemCapacity}}. Action Items: Add more storage to your system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.14 |
fluidFSEventQuotaSnapshotThresholdExceededSnapshots space exceeded threshold for NAS volume {{virtualVolumeName}}. Description: NAS volume {{virtualVolumeName}} - Snapshots space exceeded the defined snapshots threshold {{snapshotsSpaceThreshold}}% of the total size {{volumeSize}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.16 |
fluidFSEventQuotaSnapshotAvailableSpaceBelowThresholdLow space is available for snapshots in NAS Volume {{virtualVolumeName}}. Description: NAS Volume {{virtualVolumeName}} - Space available for snapshots is less than {{snapshotsSpaceThreshold}}% of the total size {{volumeSize}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.17 |
fluidFSEventQuotaUserQuotaExceededUser soft quota exceeded. User {{userNameName}}, NAS volume {{virtualVolumeName}}. Description: User {{userNameName}} on NAS volume {{virtualVolumeName}} has exceeded its soft limit. Soft limit is {{quotaThreshold}} MB. Action Items: First determine whether this is the outcome of default quota or specific user quota defined for this NAS volume. If there is a fit between the current definition and the required quota enforcement, contact the user and warn him/her that future writes might be denied due to quota violation. If there is a special user requirement, and this is the outcome of a default quota definition, you might consider defining specific user quota for this user. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.18 |
fluidFSEventQuotaGroupQuotaExceededGroup soft quota exceeded. Group {{groupNameName}}, NAS volume {{virtualVolumeName}}. Description: Group {{groupNameName}} on NAS volume {{virtualVolumeName}} has exceeded its soft limit. Soft limit is {{quotaThreshold}} MB. Action Items: First determine whether this is the outcome of default quota or specific group quota defined for this NAS volume. If there is a fit between the current definition and the required quota enforcement, contact the group manager and warn him/her that future writes might be denied due to quota violation. If there is a special group requirement, and this is the outcome of a default quota definition, you might consider defining specific group quota for this group. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.19 |
fluidFSEventQuotaVolumeFreeSpaceThresholdExceededAvailable space on NAS volume {{virtualVolumeName}} is running low. Description: NAS volume {{virtualVolumeName}} - Volume available space is less than {{volumeSpaceThreshold}}. Please note that writes to the NAS volume's clones will fail if its base Volume reaches full capacity. Action Items: See if the space shortage is caused by system space shortage or the volume is almost full. If the volume is thick or the shortage is at the volume level, you should consider removing old snapshots, cleanup the volume or increase the volume size. If the volume is thin and it is far from being full, consider removing snapshots and files in other thin volumes that are using unreserved space, purchase more storage and expand LUNs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.20 |
fluidFSEventQuotaVolumeUsedSpaceThresholdExceededNAS volume {{virtualVolumeName}} exceeded used space threshold. Description: NAS volume {{virtualVolumeName}} - Used space exceeded {{volumeSpaceThreshold}}% of the total size {{volumeSize}}. Please note that writes to the NAS volume's clones will fail if its base volume reaches full capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.21 |
fluidFSEventQuotaVolumeOutOfFreeSpaceNAS volume {{virtualVolumeName}} is out of available space. Description: NAS volume {{virtualVolumeName}} - Volume is out of available space. Please note that writes to the NAS volume and its clones will fail. Action Items: See if the space shortage is caused by system space shortage or the volume is full. If the volume is thick or the shortage is at the volume level, you should consider removing old snapshots, cleanup the volume or increase the volume size. If the volume is thin and it is far from being full, consider removing snapshots and files in other thin volumes that are using unreserved space, purchase more storage and expand LUNs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.22 |
fluidFSEventQuotaVolumeUsedSpaceOverwhelmedNAS volume {{virtualVolumeName}} used space reached the volume size (no space). Description: NAS volume {{virtualVolumeName}} - Used space reached the volume size {{volumeSize}}. Please note that writes to the NAS volume and its clones will fail. Action Items: See if the space shortage is caused by system space shortage or the volume is full. If the volume is thick or the shortage is at the volume level, you should consider removing old snapshots, cleanup the volume or increase the volume size. If the volume is thin and it is far from being full, consider removing snapshots and files in other thin volumes that are using unreserved space, purchase more storage and expand LUNs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.23 |
fluidFSEventQuotaDirectoryQuotaExceededDirectory Quota '{{quotaDirPath}}' in volume {{virtualVolumeName}} exceeded the soft limit Description: Directory Quota '{{quotaDirPath}}' in volume {{virtualVolumeName}} exceeded the soft limit of {{quotaThreshold}} MB. Action Items: Advise the users to clear some space from the directory or consider extending the quota limit. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.4.24 |
fluidFSEventsReplication OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.5 |
fluidFSEventReplicationDisconnectionReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The connection between source and destination systems was lost. The replication will continue automatically when the connection is restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.14 |
fluidFSEventReplicationInternalErrorReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: There was an internal error (err: {{errorCode}}), please contact Support. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.15 |
fluidFSEventReplicationSourceFSIsDownReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file system of source NAS volume is down. The replication will continue automatically when the file-system is started. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.16 |
fluidFSEventReplicationSourceFSIsNotOptimalReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file-system of the source NAS volume is not optimal. The replication will continue automatically when the file-system recovers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.17 |
fluidFSEventReplicationDestinationFSIsNotOptimalReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file-system of the destination NAS volume is not optimal. The replication will continue automatically when the file-system recovers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.18 |
fluidFSEventReplicationDestinationFSIsDownReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file system of destination NAS volume is down. The replication will continue automatically when the file-system is started. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.19 |
fluidFSEventReplicationConfigurationErrorReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The source and destination systems resources are not balanced. Please consider to add new applience to the destination system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.20 |
fluidFSEventReplicationMngConVipChangedCluster VIP {{oldMngConVip}} was changed to {{newMngConVip}}. Please update partnership systems with this change. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.26 |
fluidFSEventReplicationMngConVipChangedDestinationManage console VIP {{oldMngConVip}} was changed to {{newMngConVip}}. Please, update partnership systems with this change. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.49 |
fluidFSEventReplicationDestinationVolumeIsDetachedReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The destination NAS volume disconnected from the source NAS volume. Please perform the disconnect action also from the source NAS volume, and if you would like, reconnect the NAS volumes again to allow replication. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.55 |
fluidFSEventReplicationDestinationClusterIsBusyReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: Temporarily the destination cluster is not available to serve the required replication. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.56 |
fluidFSEventReplicationIncompatibleVersionsReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The system version of source NAS volume is higher than the system version of the destination system. Please upgrade the destination system to same version as source system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.57 |
fluidFSEventReplicationNotEnoughSpaceInDestinationReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: There is not enough space in the destination NAS volume. Please increase the destination NAS volume size. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.58 |
fluidFSEventReplicationSourceVolumeBusyWithReclaimingReplication between {{sourceVolumeName}}@{{sourceCluster}} and {{destinationVolume}}@{{destinationCluster}} experienced a temporary failure. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} experienced a temporary failure because of the following reason: The source NAS volume is busy freeing space. The replication will continue automatically when space is available. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.59 |
fluidFSEventReplicationDestinationVolumeBusyWithReclaimingReplication between {{sourceVolumeName}}@{{sourceCluster}} and {{destinationVolume}}@{{destinationCluster}} experienced a temporary failure. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} experienced a temporary failure because of the following reason: The destination NAS volume is busy freeing space. The replication will continue automatically when space is available. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.60 |
fluidFSEventReplicationSourceFSIsBusyReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file-system of the source NAS volume is busy with replication of other NAS volumes. The replication will continue automatically when the file-system releases part of the resources. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.61 |
fluidFSEventReplicationDestinationFSIsBusyReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The file-system of the destination NAS volume is busy with replication of other NAS volumes. The replication will continue automatically when the file-system releases part of the resources. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.62 |
fluidFSEventReplicationJumboFramesBlockedReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: Jumbo frames are blocked over the network. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.63 |
fluidFSEventReplicationRecoveredReplicationReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} successfully recovered from the problem and finished. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.64 |
fluidFSEventReplicationDestinationVolumeShrinkReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} succeeded. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} succeeded but resizing of the destination volume failed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.65 |
fluidFSEventReplicationDestinationVolumeIsDisabledReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The replication policy status on the destination volume is currently promoted. Please perform the promote action also from the source NAS volume, and demote to allow replication. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.66 |
fluidFSEventReplicationDestinationVolumeDedupParamsOptimization policy configuration is not updated. Description: As part of replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} the optimization policy configuration has failed to update. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.67 |
fluidFSEventReplicationRollbackSnapCloneBaseReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: rollback snapshot failed due to clone snapshot base. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.68 |
fluidFSEventReplicationReplicationFinishedReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} which start at {{startTime}} has transferred {{totalTransferredSize}} MB of data and finished successfully at {{endTime}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.69 |
fluidFSEventReplicationDisconnectionDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The connection between source and destination systems was lost. The replication will continue automatically when the connection is restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.70 |
fluidFSEventReplicationInternalErrorDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: There was an internal error (err: {{errorCode}}), please contact the support team NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.71 |
fluidFSEventReplicationSourceFSIsDownDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file system of source NAS volume is down. The replication will continue automatically when the file-system is started. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.72 |
fluidFSEventReplicationSourceFSIsNotOptimalDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file-system of the source NAS volume is not optimal. The replication will continue automatically when the file-system recovers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.73 |
fluidFSEventReplicationDestinationFSIsNotOptimalDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file-system of the destination NAS volume is not optimal. The replication will continue automatically when the file-system recovers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.74 |
fluidFSEventReplicationDestinationFSIsDownDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file system of destination NAS volume is down. The replication will continue automatically when the file-system is started. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.75 |
fluidFSEventReplicationConfigurationErrorDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The source and destination systems resources are not balanced. Please consider to add new applience to the destination system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.76 |
fluidFSEventReplicationDestinationVolumeIsDetachedDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The destination NAS volume disconnected from the source NAS volume, please perform the disconnect action also from the source NAS volume and if you would like reconnect the NAS volumes again. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.77 |
fluidFSEventReplicationDestinationClusterIsBusyDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: Temporarily the destination cluster is not available to serve the required replication. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.78 |
fluidFSEventReplicationIncompatibleVersionsDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The system version of source NAS volume is higher than the system version of the destination system. Please upgrade the destination system to same version as source system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.79 |
fluidFSEventReplicationNotEnoughSpaceInDestinationDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: There is not enough space in the destination NAS volume, Please increase the destination NAS volume size. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.80 |
fluidFSEventReplicationSourceVolumeBusyWithReclaimingDestinationReplication between {{sourceVolume}}@{{sourceCluster}} and {{destinationVolumeName}}@{{destinationCluster}} experienced a temporary failure Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} experienced a temporary failure because of the following reason: The source NAS volume is busy freeing space. The replication will continue automatically when space is available. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.81 |
fluidFSEventReplicationDestinationVolumeBusyWithReclaimingDestinationReplication between {{sourceVolume}}@{{sourceCluster}} and {{destinationVolumeName}}@{{destinationCluster}} experienced a temporary failure Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} experienced a temporary failure because of the following reason: The destination NAS volume is busy freeing space. The replication will continue automatically when space is available. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.82 |
fluidFSEventReplicationSourceFSIsBusyDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file-system of the source NAS volume is busy with replication of other NAS volumes. The replication will continue automatically when the file-system releases part of the resources . NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.83 |
fluidFSEventReplicationDestinationFSIsBusyDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The file-system of the destination NAS volume does not have enough resources to proceed with replication of other NAS volumes. The replication will continue automatically when the file-system releases part of the resources. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.84 |
fluidFSEventReplicationJumboFramesBlockedDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: Jumbo frames are blocked over the network. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.85 |
fluidFSEventReplicationRecoveredReplicationDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} successfully recovered from the problem and finished. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.86 |
fluidFSEventReplicationDestinationVolumeShrinkDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} succeeded Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} succeeded but resizing of the desination volume failed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.87 |
fluidFSEventReplicationDestinationVolumeIsDisabledDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The replication policy status on the destination volume is currently promoted, please perform the promote action also from the source NAS volume, and demote allow replication. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.88 |
fluidFSEventReplicationDestinationVolumeDedupParamsDestinationOptimization policy configuration is not updated Description: As part of replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} the optimization policy configuration has failed to update. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.89 |
fluidFSEventReplicationRollbackSnapCloneBaseDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: rollback snapshot failed due to clone snapshot base. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.90 |
fluidFSEventReplicationReplicationFinishedDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} which start at {{startTime}} has transferred {{totalTransferredSize}} MB of data and finished successfully at {{endTime}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.91 |
fluidFSEventReplicationNotEnoughSpaceInDestinationRehydSrcVolSizeReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: There is not enough space in the destination NAS volume. Please increase the destination NAS volume size to be at least {{rehydratedVolumeSize}} MBs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.92 |
fluidFSEventReplicationReplicationFinishedInDomainReplication {{sourceVolumeName}}, {{destinationVolume}}@{{destinationCluster}} finished in domain {{domainId}} s-{{snapshotId}}. Description: Replication {{sourceVolumeName}}, {{destinationVolume}}@{{destinationCluster}} finished in domain {{domainId}} s-{{snapshotId}}. {{domainReplicationStats}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.93 |
fluidFSEventReplicationDestinationVolumeIsReplicatingReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} failed because of the following reason: The destination NAS volume is in the middle of replicating to another NAS volume. Please temporarily disable the outgoing replications from the destination NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.94 |
fluidFSEventReplicationDestinationVolumeIsReplicatingDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed. Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} failed because of the following reason: The destination NAS volume is in the middle of replicating to another NAS volume. Please temporarily disable the outgoing replications from the destination NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.95 |
fluidFSEventReplicationReplicationFinishedWithCompressionReplication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolumeName}}@{{sourceCluster}} and NAS volume {{destinationVolume}}@{{destinationCluster}} which start at {{startTime}} has transferred {{totalTransferredSize}} MB of data with {{savingsPercent}}% savings due to data reduction and finished successfully at {{endTime}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.96 |
fluidFSEventReplicationReplicationFinishedWithCompressionDestinationReplication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} finished. Description: Replication between NAS volume {{sourceVolume}}@{{sourceCluster}} and NAS volume {{destinationVolumeName}}@{{destinationCluster}} which start at {{startTime}} has transferred {{totalTransferredSize}} MB of data with {{savingsPercent}}% savings due to data reduction and finished successfully at {{endTime}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.5.97 |
fluidFSEventsSnapshot OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.7 |
fluidFSEventSnapshotFailedCreateSnapshotThe snapshot scheduler failed to create {{snapshotName}} snapshot in volume {{volumeName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.1 |
fluidFSEventSnapshotFailedDeleteSnapshotThe snapshot scheduler failed to delete snapshots in volume {{volumeName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.2 |
fluidFSEventSnapshotScheduleDeleteSnapshotBySpaceThe snapshot named {{snapshotName}} on {{volumeName}} NAS volume was scheduled for deletion by snapshots space auto-deletion mechanism. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.3 |
fluidFSEventSnapshotFailedToInitVMSnapshotsCreationFailed initializing the VM snapshot(s) creation Description: Failed to initiate VM snapshot(s) creation on VMWare server(s), thus {{snapshotName}} snapshot of {{FSIDName}} NAS volume will not be consistent from VMWare perspective Action Items: Please check network availability and current load on related VMWare server(s) Internal Information: One (or more) VMWare servers may be unavailable or responds with errors to FluidFS requests NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.8 |
fluidFSEventSnapshotFailedToPerformVMSnapshotsCreationFailed to create VM snapshot(s) on VMWare server(s) Description: Failed to create VM snapshot(s), thus {{snapshotName}} snapshot of {{FSIDName}} NAS volume will not be consistent from VMWare perspective Action Items: Please check network availability and current load on related VMWare server(s) Internal Information: One (or more) VMWare servers may be unavailable or responds with errors to FluidFS requests NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.9 |
fluidFSEventSnapshotFailedToPerformVMSnapshotsCleanupFailed removing the VM snapshot(s), created by FluidFS Description: Failed to perform a cleanup of VM snapshot(s), previously created by FluidFS on VMWare server(s) during {{snapshotName}} snapshot of {{FSIDName}} NAS volume creation Action Items: Please check network availability and current load on related VMWare server(s). Try to delete the redundant VM snapshot(s) manually in the vSphere user interface Internal Information: One (or more) VMWare servers may be unavailable or responds with errors to FluidFS requests NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.10 |
fluidFSEventSnapshotSnapshotIsNotVMConsistentThe {{snapshotName}} snapshot is not consistent from VMWare perspective Description: NAS volume {{FSIDName}} had been restored to the {{snapshotName}} snapshot recovery point, which is not consistent from VMWare perspective Action Items: In case {{FSIDName}} NAS volume indeed serves as VMWare Datastore, please try to restore the volume to a consistent snapshot recovery point NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.11 |
fluidFSEventSnapshotSnapshotDeltaFailedSnapshot delta process on volume {{FSIDName}} failed Description: NAS volume {{FSIDName}} did not finish properly and therefore aborted Action Items: Please restart the process NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.12 |
fluidFSEventSnapshotSnapshotDeltaSuccededSnapshot delta process on volume {{FSIDName}} succeded Description: NAS volume {{FSIDName}} has finished properly and file {{outputFileName}} was created in path {{outputPath}} on volume {{outputFSIDName}} Action Items: file {{outputFileName}} was created in path {{outputPath}} on volume {{outputFSIDName}} and is available now for reading NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.13 |
fluidFSEventSnapshotSnapshotDeltaStartedSnapshot delta process on volume {{FSIDName}} started Description: NAS volume {{FSIDName}} has started with output file {{outputFileName}} in path {{outputPath}} on volume {{outputFSIDName}} Action Items: file {{outputFileName}} will be created in path {{outputPath}} on volume {{outputFSIDName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.7.14 |
fluidFSEventsHealth OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.9 |
fluidFSEventHealthNodeFailedNAS controller {{nodeName}} is unavailable. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.4 |
fluidFSEventHealthNodeOKNAS controller {{nodeName}} is available. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.5 |
fluidFSEventHealthLocalPartitionIsFullThe used space of local file system partition {{partitionName}} on NAS controller {{nodeName}} is high ({{percentOfUsedSpace}}%). Please contact support. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.6 |
fluidFSEventHealthHighUseOfSwapThe usage of swap memory on NAS controller {{nodeName}} is high ({{percentOfUsedSwap}}%). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.7 |
fluidFSEventHealthHighUseOfMemoryThe memory usage on NAS controller {{nodeName}} is high. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.8 |
fluidFSEventHealthHighUseOfFileDescriptorsFile descriptors usage on NAS controller {{nodeName}} is high ({{percentOfUsedFileDescriptors}}%). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.9 |
fluidFSEventHealthPairPowerProblemThe system switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} BPS is not functioning properly and its peer controller {{peerNodeId}} has health problems as well. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.10 |
fluidFSEventHealthPairPowerProblemRecoveredThe system switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} verified the power system reliability and switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.11 |
fluidFSEventHealthSafeShutdownBeginsThe power button of NAS controller {{thisNodeId}} was pressed. Description: The power button of NAS controller {{thisNodeId}} was pressed. The NAS controller's cache is being flushed and will orderly shut down in approximately 5 minutes. Please allow it to finish. Action Items: If this process takes longer than expected, don't try to workaround by manually shutting down the NAS controller. Please contact Support. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.12 |
fluidFSEventHealthSafeShutdownEndsNAS controller {{thisNodeId}} cache was flushed and it is shutting down. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.13 |
fluidFSEventHealthPairTemperatureProblemThe system switched Write-Through mode on (journaling). Description: The system switched Write-Through mode on (journaling) because both NAS controllers' temperature appears high (or cannot be verified), on the controller pair with IDS {{thisNodeId}} and {{peerNodeId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.14 |
fluidFSEventHealthPairTemperatureProblemRecoveredThe system switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} verified the temperature system reliability and switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.15 |
fluidFSEventHealthClientsOnFailbackThere are clients ({{numberOfClients}}) that are waiting for manual failback. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.16 |
fluidFSEventHealthCacheLossOfUserFilesLatest user writes might have been lost. Description: The system identified that some of the latest user writes might have been lost. This might have been caused by a reboot of two NAS controllers in the same NAS appliance simultaneously. The system will start an automatic recovery procedure and in few minutes you should receive a completion event. During that time you will have partial or no service, SMB clients will be disconnected and NFS clients will be forced to remount. After the system is fully functional, please check your applications integrity and repeat the latest writes if needed. Action Items: In case repeating the latest writes is not possible or you still experience any difficulties, consider recovering the data from the latest snapshots or from backup. Internal Information: Domain {{domainId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.21 |
fluidFSEventHealthCacheLossOfMetadataFile System process failed to recover. Description: The system identified that at least one of its File System processes has restarted and failed to recover it. The system will provide limited service. Please contact Support for further assistance. Action Items: Search product Knowledge Base for further information. Internal Information: Domain {{domainId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.22 |
fluidFSEventHealthCacheLossRecoveredFile system recovery successfully finished. Description: File system recovery successfully finished. Action Items: Data written in the day prior to the event might be compromised and should be verified. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.23 |
fluidFSEventHealthStoreAccessProblemLost communication to storage from NAS controller {{nodeId}}. Description: The system identified a communication problem between NAS controller {{nodeId}} and the storage controllers which may affect system performance. Action Items: The system constantly monitors the validity of communication between NAS controllers and Storage controller. This event is issued once the system identifies a communication issue. If the system was recently deployed or any of its components were recently moved, verify that all connections and configurations are according to the recommendations. If the system was functioning optimally for a while and this is a new event it is most likely due to a physical problem (like a bad/loose cable) or a change in network configuration which affects the components communication. Verify that all the network cables are correctly connected to the relevant NAS controller. Verify that all the iSCSI switches are up and running. If any change was introduced to the environment (new physical switch, new switch configuration), try to revert this change in order to understand the cause of the problem. Verify that the iSCSI switch is configured according to the recommendation. If the problem is persistent after verifying all the above, it is recommended to power cycle the problematic NAS controller using the UI. Internal Information: Domain {{domainId}} setId {{setId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.24 |
fluidFSEventHealthLunVerificationFailureNAS controller {{nodeId}} encountered a problem accessing a NAS storage pool. Action Items: Please contact Support. Internal Information: Domain {{domainId}} LUN {{lunId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.25 |
fluidFSEventHealthFileSystemMajorAccessibilityProblemClients may encounter a long period of partial data access. Description: The file system identified that clients may have partial data access in the last {{timeout}} minutes. Action Items: The NAS file system constantly verifies that it is accessible for read/write operations. This event is issued once it identifies that some operations took more time than expected or failed completely in the last {{timeout}} minutes. This could be caused by an intermittent issue of a HW failure like failed disk or disconnected network port. Verify that no RAID is being rebuilt and you do not have a recently failed drive. Verify that the cluster is connected according to the recommended cabling method and switch configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.27 |
fluidFSEventHealthFileSystemAccessibilityRevivalFile system back to optimal state. Description: The File System has overcome its accessibility problem and returned back to full functionality. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.28 |
fluidFSEventHealthFSMultipleRmapChecksumErrorMultiple erroneous file system blocks were identified and fixed. Action Items: If the problem recurs, verify system hardware health. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.47 |
fluidFSEventHealthFSSystemUnrecoverableRmapChecksumErrorUnrecoverable erroneous block was identified. Description: Unrecoverable erroneous block was identified. The file system is partially serving. Action Items: Contact Support. Internal Information: File {{dsid}} mapping {{fileMapping}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.48 |
fluidFSEventHealthFSMultipleUserMetaDataMissingMultiple directory entries were identified as missing. Action Items: Recover them from backup. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.50 |
fluidFSEventHealthFSLowOnLunSpaceHigh NAS pool capacity. Performance might be affected. Description: NAS pool capacity usage has reached high watermark which will affect performance. Action Items: Expand the NAS pool capacity, or free some space. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.53 |
fluidFSEventHealthBadClientLoadBalancingBad {{protocol}} clients distribution: ({{connectionsVector}}). Description: Bad {{protocol}} clients distribution: ({{connectionsVector}}). Each pair in this set represents NAS controller ID and number of connections separated by a colon. Use the mass rebalance feature available via the clients connections screen. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.65 |
fluidFSEventHealthCifsLockingInconsistancyInconsistent locks interrupted SMB service. Description: SMB service is interrupted due to inconsistencies in locking mechanism, starting recovery process. Internal Information: Domain {{domainId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.66 |
fluidFSEventHealthCifsLockingInconsistancyRecoveredInconsistent locks recovered. Description: SMB locking inconsistencies recovery was successfully finished. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.67 |
fluidFSEventHealthFSReclaimerOverloadHigh load in snapshots space reclaiming process. Description: The file system has been recently engaged in reclaiming the space of deleted snapshots or NAS volumes. This could be the result of the deletion of a NAS volume and/or multiple snapshots. Action Items: If this event recurs on a daily basis, the file system performance can be improved; Reducing the frequency of snapshot scheduling will make more resources available for clients activity. Internal Information: Domain {{domainId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.72 |
fluidFSEventHealthPairStoreSetProblemSystem switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} has lost connection to storage subsystem and its peer NAS controller {{peerNodeId}} has health problems as well. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.75 |
fluidFSEventHealthPairStoreSetProblemRecoveredSystem switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} verified connection to storage subsystem and switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.76 |
fluidFSEventHealthPairPowerSuppliesProblemThe system switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} has lost full power supplies redundancy and its peer NAS controller {{peerNodeId}} has health problems as well. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.77 |
fluidFSEventHealthPairPowerSuppliesRecoveredThe system switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} full power supplies redundancy was restored and switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.78 |
fluidFSEventHealthPairFansProblemThe system switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} fans are not working properly and its peer NAS controller {{peerNodeId}} has health problems as well. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.85 |
fluidFSEventHealthPairFansRecoveredThe system switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} fans are working properly. Switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.86 |
fluidFSEventHealthProtocolsStateInconsistancyInconsistent state interrupted SMB/NFSv4 service. Description: SMB/NFSv4 services are interrupted due to inconsistencies in locking mechanism, starting recovery process. Internal Information: Domain {{domainId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.87 |
fluidFSEventHealthProtocolsStateInconsistancyRecoveredInconsistent locks recovered. Description: SMB/NFSv4 locking inconsistencies recovery was successfully finished. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.88 |
fluidFSEventHealthFSDedupSpaceMarginReachedOptimization paused on volume {{virtualVolume}} - insufficient space. Description: Volume {{virtualVolume}} doesn't have the required free {{dedupSpaceMarginMb}} MB needed for optimization. Action Items: Make sure volume {{virtualVolume}} has at least {{dedupSpaceMarginMb}} MB free. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.91 |
fluidFSEventHealthStoreAccessRestoredRestored communication to storage from NAS controller {{nodeId}}. Description: The system identified that a communication problem between NAS controller {{nodeId}} and the storage controllers was resolved. Internal Information: Domain {{domainId}} setId {{setId}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.92 |
fluidFSEventHealthDuplicateIpDuplicate IP address {{ipAddr}} in use on the node {{nodeId}}. Description: On node {{nodeId}} an ip address {{ipAddr}} in use on this system is being used by another system with mac address {{macAddr}}. Action Items: Either change the address {{ipAddr}} on node {{nodeId}}, or on the other device. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.102 |
fluidFSEventHealthUnmapIsNotSupportedOnLunsUnmap is not supported by some of the LUNs Description: The following LUNs doesn't support the unmap functionallity: {{LunsList}}. Action Items: Please consider to upgrade the listed LUNs to the newest version. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.103 |
fluidFSEventHealthPairHWProblemThe system switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} hardware is not working properly and its peer NAS controller {{peerNodeId}} has health problems as well. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.110 |
fluidFSEventHealthPairHWRecoveredThe system switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} hardware is working properly. Switched Write-Through mode off (mirroring). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.111 |
fluidFSEventHealthUnresponsiveVmwareServerOnAllNodesVMWare service is unavailable on all NAS-Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.112 |
fluidFSEventHealthUnresponsiveVmwareServerOnNodesVMWare service is unavailable on all NAS-Controllers {{nodeIds}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.113 |
fluidFSEventHealthResponsiveVmwareServerOnAllNodesVMWare service is available on all NAS-Controlles NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.114 |
fluidFSEventHealthCouldNotAllocateProtectedMemoryProblem with allocating protected memory Description: Memory detector could not allocate the protected memory Action Items: Please contact support NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.115 |
fluidFSEventHealthInvalidSizeOfProtectedMemoryProblem with allocating protected memory Description: The model's predefined size of protected memory is not equal to allocated Action Items: Please contact support NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.116 |
fluidFSEventHealthCouldNotAllocateUnProtectedMemoryProblem with allocating unprotected memory Description: Preallocation script could not allocate the unprotected memory Action Items: Please contact support NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.117 |
fluidFSEventHealthUnresponsiveIscsiPortalsOnAllNodesiSCSI portals are unavailable on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.118 |
fluidFSEventHealthUnresponsiveIscsiPortalsOnNodesiSCSI portals are unavailable on NAS Controllers {{nodeIds}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.119 |
fluidFSEventHealthResponsiveIscsiPortalsOnAllNodesiSCSI portals are available on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.120 |
fluidFSEventHealthUnavailableNtpServiceOnAllNodesNTP service is unavailable on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.121 |
fluidFSEventHealthAvailableNtpServiceOnAllNodesNTP service become available on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.122 |
fluidFSEventHealthUnavailableNtpServiceOnNodesNTP service is unavailable on NAS Controllers {{nodeIds}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.123 |
fluidFSEventHealthUnavailableAntivirusOnAllNodesAntivirus is unavailable on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.124 |
fluidFSEventHealthAvailableAntivirusOnAllNodesAntivirus become available on all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.125 |
fluidFSEventHealthUnavailableAntivirusOnNodesAntivirus is unavailable on NAS Controllers {{nodeIds}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.126 |
fluidFSEventHealthUnavailableAuditingServicesOnAllNodesAuditing subscribers became unavailable for all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.127 |
fluidFSEventHealthAvailableAuditingServicesOnAllNodesAuditing subscribers became available for all NAS Controllers NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.128 |
fluidFSEventHealthUnavailableAuditingServicesOnNodesAuditing subscribers became unavailable for NAS Controller/s: {{nodeIds}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.129 |
fluidFSEventHealthPairCacheArmingProblemSystem switched Write-Through mode on (journaling). Description: NAS controller {{thisNodeId}} has problems with arming the protected memory, as well as it's peer. Switched Write-Through mode on (journaling). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.130 |
fluidFSEventHealthPairCacheArmingProblemRecoveredSystem switched Write-Through mode off (mirroring). Description: NAS controller {{thisNodeId}} succeeded arming the protected memory, and switched Write-Through mode off (mirroring) . NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.131 |
fluidFSEventHealthCouldNotArmProtectedMemoryRegionProblem with arming of protected memory regions Description: Memory detector could not arm protected memory region Action Items: Please contact support NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.132 |
fluidFSEventHealthFSUserMetaDataMissingDirectory entry was identified as missing; Entry {{dirEntry}} in {{parentDirDsidPath}}. Action Items: Recover it from backup. Internal Information: File {{dsid}} volume {{FSIDName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.133 |
fluidFSEventHealthUnresponsiveLdapServersOnAllNodesLDAP servers, used by {{TenantName}}, are not responding. Description: All LDAP servers ({{serverNames}}), used by {{TenantName}}, are not responding on all NAS Controllers. For each server please check: its server logs for any event that caused it not to respond to requests; that it responds to ping requests from clients on the same subnetwork; that it responds to LDAP requests from clients on the same subnetwork. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.134 |
fluidFSEventHealthUnresponsiveLdapServersOnSomeNodesAll LDAP servers ({{serverNames}}), used by {{TenantName}}, are unresponsive on some NAS Controllers: {{nodeIds}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.135 |
fluidFSEventHealthResponsiveLdapServerOnAllNodesFound responsive LDAP server(s) among ({{serverNames}}), used by {{TenantName}}, on all NAS Controllers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.136 |
fluidFSEventHealthUnresponsiveNisServersOnAllNodesNIS servers, used by {{TenantName}}, are not responding. Description: All NIS servers ({{serverNames}}), used by {{TenantName}}, are not responding on all NAS Controllers. For each server please check: its server logs for any event that caused it not to respond to requests; that it responds to ping requests from clients on the same subnetwork; that it responds to NIS requests from clients on the same subnetwork. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.137 |
fluidFSEventHealthResponsiveNisServerOnAllNodesFound responsive NIS server(s) among ({{serverNames}}), used by {{TenantName}}, on all NAS Controllers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.138 |
fluidFSEventHealthUnresponsiveNisServersOnSomeNodesAll NIS servers ({{serverNames}}), used by {{TenantName}}, are unresponsive on some NAS Controllers: {{nodeIds}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.139 |
fluidFSEventHealthUnresponsiveDnsServersOnAllNodesDNS servers, used by {{TenantName}}, are not responding. Description: All DNS servers ({{serverIps}}), used by {{TenantName}}, are not responding on all NAS Controllers. For each server please check: its server logs for any event that caused it not to respond to requests; that it responds to ping requests from clients on the same subnetwork; that it responds to DNS requests from clients on the same subnetwork. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.140 |
fluidFSEventHealthResponsiveDnsServerOnAllNodesFound responsive DNS server(s) among ({{serverIps}}), used by {{TenantName}}, on all NAS Controllers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.141 |
fluidFSEventHealthUnresponsiveDnsServersOnSomeNodesAll DNS servers ({{serverIps}}), used by {{TenantName}}, are unresponsive on some NAS Controllers: {{nodeIds}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.142 |
fluidFSEventHealthUnresponsiveAdServerActive Directory, used by {{TenantName}}, is not responsive. Description: Active Directory domain {{domainName}}, used by {{TenantName}}, is not reachable. For each domain controller please check: its logs for any event that caused it not to respond to requests; that it responds to ping requests from clients on the same subnetwork; that it responds to AD requests from clients on the same subnetwork. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.143 |
fluidFSEventHealthResponsiveAdServerActive Directory domain {{domainName}}, used by {{TenantName}}, is reachable. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.144 |
fluidFSEventHealthSlowResponseSlow response time from {{serverKind}} to {{TenantName}}. Description: Response time from {{serverKind}} servers ({{serverList}}) of {{responseTime}} seconds exceeds {{criticalResponseTime}} seconds on {{TenantName}}. Action Items: Check availability of all {{serverKind}} servers. This error is usually the outcome of a communication error between the NAS and the external server. It could be caused by a network issue, external server overload or a software malfunction in one of environment components. Internal Information: {{internalInfo}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.145 |
fluidFSEventHealthAdCriticalClockSkewAD (used by {{TenantName}}) and NAS controller {{nodeId}} clocks aren't synchronized Description: Clock of NAS controller {{nodeId}} and AD clock, used by {{TenantName}} (domain {{DomainControllerName}}), are not synchronized (skew of {{adClockSkew}} seconds exceeds critical threshold of {{maxAdClockSkew}} seconds). Kerberos authentication may fail. Fix system clock/Fix AD clock. Enter the time configuration screen and get the configured NTP host. If no NTP is configured, it is recommended to configure one by either using the organization's NTP or the same IP/name used for joining the NAS to the AD. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.146 |
fluidFSEventHealthCIFSAttachedACLCorruptionFailed to read a file ACL's. Description: ACL of file {{dsidPath}} can not be read. Access will be denied to all users. Action Items: Please reset the file ACL NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.147 |
fluidFSEventHealthFSUserUnrecoverableRmapChecksumErrorUnrecoverable erroneous block in user file. Description: Unrecoverable erroneous block was identified in {{dsidPath}} and it is inaccessible. Action Items: Move this file/directory to a different name, and recover it from backup. Internal Information: Mapping {{fileMapping}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.149 |
fluidFSEventHealthFSVolumeUnrecoverableRmapChecksumErrorNAS Volume {{FSIDName}} is partially serving. Description: Unrecoverable erroneous block was identified in volume {{FSIDName}}. This volume is partially serving. Action Items: Run the file system diagnostics and contact Support. Internal Information: File {{dsid}} mapping {{fileMapping}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.150 |
fluidFSEventHealthFSRehydrationSpaceMarginReachedRehydration paused on volume {{FSIDName}} - insufficient space. Description: Volume {{FSIDName}} doesn't have the required free {{dedupSpaceMarginMb}} MB needed for rehydration. Action Items: Make sure volume {{FSIDName}} has at least {{dedupSpaceMarginMb}} MB free. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.151 |
fluidFSEventHealthFSLowOnLunSpaceDedupPostponedHigh NAS pool space usage. Data Reduction paused on cluster. Description: Cluster does not have the required NAS pool free space needed for Data Reduction Action Items: Please perform one of the following actions to increase NAS pool free space : expand your NAS pool; Delete old Snapshots; Delete redundant NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.154 |
fluidFSEventHealthFSLowOnLunSpaceDedupResumedData Reduction resumed on cluster. Description: NAS pool free space increased. Data reduction is resumed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.155 |
fluidFSEventHealthFSLowOnLunSpaceFSNotAccessibleHigh NAS pool space usage. File system access is limited Description: High NAS pool space usage. File system is accessible only using NFS3. Action Items: Please perform one of the following actions to increase NAS pool free space : expand your NAS pool; Delete old Snapshots; Delete redundant NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.156 |
fluidFSEventHealthFSLowOnLunSpaceFSAccessibleFile system access is back to normal. Description: NAS pool free space increased. File system can be accessed by all protocols NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.157 |
fluidFSEventHealthLocalTimeDesynchronizedToNtpLocal time on node {{nodeId}} is desynchronized by {{timeDiffSec}} seconds. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.9.158 |
fluidFSEventsAntivirus OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.10 |
fluidFSEventAntivirusAntivirusHostUpAntivirus host {{host}}:{{port}} accessibility is restored. Description: Antivirus host {{host}}:{{port}} accessibility is restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.16 |
fluidFSEventAntivirusAntivirusHostDownAntivirus host {{host}}:{{port}} is not accessible. Description: Antivirus host {{host}}:{{port}} is not accessible. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.17 |
fluidFSEventAntivirusAntivirusLicenseErrorAntivirus host {{host}}:{{port}} returns license error. Description: Antivirus host {{host}}:{{port}} returns license error. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.18 |
fluidFSEventAntivirusAntivirusAllDownNo antivirus hosts are accessible. Description: No antivirus hosts are accessible. Virus scanning is not possible. SMB Shares with AV scan configured will not be accessible. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.19 |
fluidFSEventAntivirusAntivirusServersNotConfiguredAntiVirus servers are not configured. Description: SMB share {{shareName}} is configured to use antivirus checking but no AV servers are configured yet. Access to the files inside the share is denied. Action Items: AntiVirus servers must be configured to provide AntiVirus facility NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.27 |
fluidFSEventAntivirusAntivirusScanWasTooLong2Antivirus scan for file {{FSIDName}}/{{dsidPath}} took too long Description: Scanning for viruses for file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}} took too long: {{scanningDuration}} seconds (must be less than {{scanningDurationThreshold}}), scanning facility '{{scanningFacility}}'. Action Items: Please check network availability and current load on problematic AntiVirus facility. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.31 |
fluidFSEventAntivirusAccessDeniedVirus was found in file {{FSIDName}}/{{dsidPath}} but quarantine is not applicable. Description: Virus ({{virusDescription}}) was found in file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. Quarantine action is not possible for this file, access to file is denied. Internal Information: Reason why quarantine action is not possible: {{accessDeniedReason}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.32 |
fluidFSEventAntivirusAccessDeniedDueInternalErrorAn error occurred while scanning the file {{FSIDName}}/{{dsidPath}} for viruses. Description: An error occurred during AV scan of the file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. Access to file is denied. Internal Information: Error details: {{accessDeniedReason}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.33 |
fluidFSEventAntivirusUnexpectedAvResponseError occurred while scanning for viruses. Description: AV server returned unexpected error during the scan for file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. Access is denied. Internal Information: ICAP protocol issue: unexpected ICAP status code {{icapStatus}} returned by facility {{server}}:{{port}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.34 |
fluidFSEventAntivirusQuarantineActionFailedVirus was found in file {{FSIDName}}/{{dsidPath}} but quarantine action has failed. Description: Virus ({{virusDescription}}) was found in file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. Quarantine action failed for this file, access to file is denied. Internal Information: Quarantine action error details: {{accessDeniedReason}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.35 |
fluidFSEventAntivirusInfectedFileQuarantined2Virus was found in file {{FSIDName}}/{{filePath}}, quarantine action is applied. Description: Virus ({{virusDescription}}) was found in file {{filePath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. File is moved to quarantine (new path is {{dsidPath}}). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.36 |
fluidFSEventAntivirusInfectedFileRepairedInfected file {{FSIDName}}/{{dsidPath}} was repaired. Description: Virus ({{virusDescription}}) was found in file {{dsidPath}} on NAS volume {{FSIDName}} accessed via SMB share {{shareName}}. The file was repaired automatically. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.37 |
fluidFSEventAntivirusAccessDeniedLargeFileNotScannedAccess denied: file {{FSIDName}}/{{dsidPath}} is too large for AV verification. Description: File {{dsidPath}} (which is {{fileSizeMb}} MB) on NAS volume {{FSIDName}} accessed via SMB share {{shareName}} cannot be scanned for viruses because it exceeds the maximum scan size ({{largeFileSizeLimitMb}} Mb). This share is configured to block access to un-scanned files. Action Items: Increase the maximum scan size for AV scanning or change the policy to allow un-scanned files for access. Please note, Anti-virus scan of large files may delay the initial open request. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.38 |
fluidFSEventAntivirusLargeFileNotScannedAccess allowed: file {{FSIDName}}/{{dsidPath}} was opened without AV verification. Description: File {{dsidPath}} (which is {{fileSizeMb}} MB) on NAS volume {{FSIDName}} accessed via SMB share {{shareName}} was not scanned for viruses because it exceeds the maximum scan size ({{largeFileSizeLimitMb}} MB). Action Items: Increase the maximum file size for AV scan or change the policy to deny un-scanned files for access. Please note, Anti-virus scan of large files may delay the initial open request. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.10.39 |
fluidFSEventsClientAccess OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.11 |
fluidFSEventClientAccessMountFailureInternalErrorNFS mount failure. Internal mount error {{mountPath}}. Description: NFS mount failure: Internal mount error for the client {{clientIpAddr}} while mounting path {{mountPath}}. Internal Information: NFS error code: {{nfsErrorCode}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.6 |
fluidFSEventClientAccessResetAdminPasswordFromConsoleAdministrator password was reset from the console. Description: Administrator password was reset from the console. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.51 |
fluidFSEventClientAccessSMBMemThreshold1Due to SMB high resource usage disabling Large MTU. Description: Due to SMB high resource usage disabling Large MTU on NAS controller {{nasControllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.54 |
fluidFSEventClientAccessSMBMemThreshold2Due to SMB high resource usage new connections not allowed. Description: Due to SMB high resource usage new connections are not allowed on NAS controller {{nasControllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.55 |
fluidFSEventClientAccessLockDBOutOfResourcesFile open or lock denied due to lack of internal resources. Description: NAS controller {{nodeId}} is low on resources and cannot serve SMB and NFSv4 file open and lock requests. Disconnect existing connections to free resources. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.58 |
fluidFSEventClientAccessSessionDBOutOfResourcesNFSv4 session was denied. Too many sessions currently in use Description: No resources available for new NFSv4 sessions as too many sessions are currently in use. NAS controller {{nodeId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.59 |
fluidFSEventClientAccessUsersProxyNoServiceNFS/SMB partial service Description: Access to {{serverKind}} directory service is limited or service is temporary unavailable Action Items: This scenario usually happens after directory changes (UNIX database re-configuration, Active Directory join, etc). The problem can occur due poor performance of newly configured directory; please wait some time until new directory will be fully initialized. In case of unexpected or persistent problem please check the operability of directory and network connectivity to directory service. Also problems with '{{service}}' internal service can cause this issue - please check for problematic services. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.70 |
fluidFSEventClientAccessSecChangeErrorBypassOnSecurity change errors bypassed Description: Errors due to chmod/chown/chgrp on volumes with windows security style now bypassed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.71 |
fluidFSEventClientAccessSecChangeErrorBypassOffSecurity change errors returned Description: Errors due to chmod/chown/chgrp on volumes with windows security style now returned NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.72 |
fluidFSEventClientAccessFluidFsNotifyEventsDroppedDue2InternalIssuesFile Access Notifications were dropped. Description: {{droppedNotificationsCounter}} File Access Notifications were dropped due to internal issues NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.80 |
fluidFSEventClientAccessFluidFsNotifyEventsDroppedDue2ServerIssuesFile Access Notifications were dropped. Description: {{droppedNotificationsCounter}} File Access Notifications were dropped due to auditing server issues NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.81 |
fluidFSEventClientAccessFluidFsNotifyEncryptionFailureFile Access Notification encryption failed Description: Failed initializing encrypted connection to the auditing server. encryption credentials configuration may be invalid NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.82 |
fluidFSEventClientAccessMountFromInsecurePortNFS mount failure. Wrong port was used for secure export {{nfsExport}}. Description: NFS mount failure: Client {{clientIpAddr}} attempted to mount the secure export {{nfsExport}} on NAS Volume {{nasContainerIdIntegerName}} but used port {{nfsClientPort}} instead of a well-known port (under 1024) on the client side. Action Items: Secure exports require that the client accessing them will perform the mount using a well-known port (under 1024). This is done as a security measure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.89 |
fluidFSEventClientAccessMountExportDoesntExistNFS mount failure. The path {{mountPath}} is not exported by {{TenantName}}. Description: NFS mount failure: Client {{clientIpAddr}} attempted to mount the path ({{mountPath}}) from {{TenantName}} which is not exported to NFS clients. Action Items: This failure is commonly caused by spelling mistakes done on the client machine or when accessing the wrong server. List all available exports on the NAS and verify everything is as expected, all the needed exports exist and nothing has been changed unintentionally. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.90 |
fluidFSEventClientAccessMountPathDoesntExistNFS mount failure. Non existent mount path {{mountPath}}. Description: NFS mount failure: Client {{clientIpAddr}} tried to mount nonexistent mount path {{mountPath}} on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.91 |
fluidFSEventClientAccessMountFailurePermissionDeniedNFS mount failure. Access denied during mount {{mountPath}}. Description: NFS mount failure: Access denied for the client {{clientIpAddr}} while mounting path {{mountPath}} on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.92 |
fluidFSEventClientAccessMountFailedDueExportOptionsNFS mount failure. Access attempt to limited export {{nfsExport}} Description: NFS mount failure: Client {{clientIpAddr}} is not allowed to access export {{nfsExport}} on NAS Volume {{nasContainerIdIntegerName}}, with defined export options: {{nfsExportOptions}}. Action Items: This error is caused by a client which accesses a limited export. The export was defined with clients limitations (network or netgroup or IP) that did not include the accessing client. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.93 |
fluidFSEventClientAccessMountFailedDueNetgroupFailureNFS mount failure. Netgroups could not be attained {{nfsExport}}. Description: NFS mount failure: Client {{clientIpAddr}} failed to mount export {{nfsExport}} on NAS Volume {{nasContainerIdIntegerName}} since the required netgroup information could not be attained. Export options: {{nfsExportOptions}}. Action Items: Check availability of NIS/LDAP server. This error is usually the outcome of a communication error between the NAS and the NIS/LDAP server. It could be caused by a network issue, directory server overload or a software malfunction in one of environment components. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.94 |
fluidFSEventClientAccessClientClockSkewClient authentication failed on {{TenantName}} due to client clock skew. Description: Kerberos authentication failed because of the client clock skew between client {{clientIpAddr}} and NAS controller {{nasControllerId}} of {{TenantName}}. Action Items: Fix client clock. Your client clock must be within 5 minutes range from the Kerberos server (i.e. AD) clock. Configure the used AD as an NTP server for this client to avoid clock skews errors. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.95 |
fluidFSEventClientAccessSharePathNotFoundClient connect failure. Share {{cifsShare}} points to invalid directory. Description: SMB client connection failure: Client {{clientIpAddr}} accessed a nonexistent share {{cifsShare}} which refers to an inexistent directory {{nasContainerPath}} in NAS Volume {{nasContainerIdIntegerName}}. Action Items: List all available shares on the NAS and identify the problematic share. It should have an indication that it is not accessible. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.96 |
fluidFSEventClientAccessIncorrectUserPasswordSMB client login to {{TenantName}} failed. Wrong password for user {{userName}}. Description: SMB client login failure: Client {{clientIpAddr}} with user name '{{userName}}' supplied the wrong password. NAS Controller {{nasControllerId}} of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.97 |
fluidFSEventClientAccessLoginFailureSMB client login to {{TenantName}} failed. Authorization failed for user {{userName}}. Description: Authorization for user '{{userName}}' failed, client {{clientIpAddr}}, NAS controller {{nasControllerId}} of {{TenantName}}. Internal Information: {{internalInfo}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.98 |
fluidFSEventClientAccessShareDoesntExistSMB client connection failure. Unavailable share {{cifsShare}} on {{TenantName}}. Description: SMB client connection failure: Client {{clientIpAddr}} attempted to connect to an unavailable share {{cifsShare}} of {{TenantName}}. Action Items: This failure is commonly caused by spelling mistakes done on the client machine or by a user trying to access the home share of a different user. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.99 |
fluidFSEventClientAccessNfsAccessDeniedNFS user {{nfsUserName}} access to a file denied. Insufficient permissions. Description: NFS access denied: user {{nfsUserName}} does not have sufficient permissions for the file {{dsidPath}} on NAS Volume {{nasContainerIdIntegerName}}. Desired/granted access mask: {{desiredNfsAccessMaskHrf}} / {{grantedNfsAccessMaskHrf}}. Internal Information: {{internalInfo}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.100 |
fluidFSEventClientAccessNfsModificationOfRoExportNFS access denied. Attempt to modify a read-only export {{nfsExport}}. Description: NFS Access Denied: User {{nfsUserName}} accessing from {{clientIpAddr}} tried to perform modifications on a read-only export: {{nfsExport}}, NAS Volume {{nasContainerIdIntegerName}}. Action Items: Verify that the relevant export definition of read-only was done intentionally. Contact the user who is responsible for this access or for application access to understand the reason for using read-only export with write operations. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.101 |
fluidFSEventClientAccessNfsAccessFromInsecurePortToSecureExportNFS access denied. Secured port must be used; export {{nfsExport}}. Description: NFS Access Denied: User {{nfsUserName}} tried to access from {{clientIpAddr}} to a secure export {{nfsExport}}, NAS Volume {{nasContainerIdIntegerName}} using a non secure port {{nfsClientPort}}. Action Items: Secure exports require that the client accessing them will use a well-known port (under 1024). This is done as a security measure. Identify the relevant export and the checkbox that marks it as secure/requires secure port. If there is no need for a secure export (e.g. the network is not public) make the export insecure by unchecking the secure export option and try again. If the export must remain secure, please refer to the NFS client documentation in order to change the currently used NFS client port to a well-known port (under 1024). NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.102 |
fluidFSEventClientAccessModificationOfRoVolumeAccess denied. Attempt to modify a read-only NAS volume {{nasContainerIdIntegerName}}. Description: Access denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} tried to modify the file {{dsidPath}} with operation '{{nfsOp}}' on a read-only NAS volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.103 |
fluidFSEventClientAccessModifyAccessToSnapshotAccess denied. Attempt to modify a snapshot; NAS volume {{nasContainerIdIntegerName}}. Description: Access denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} tried to modify the file {{dsidPath}} on NAS volume {{nasContainerIdIntegerName}} that is located in a snapshot. Action Items: Snapshot is an exact representation of the NAS volume data at the time of the snapshot creation. For that reason, and by definition, snapshot data can't be modified. Contact the user and instruct him to limit any modifications to the current work area in the NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.104 |
fluidFSEventClientAccessNfsOpNotAllowedDueVolumeStyleNFS access denied. Operation not permitted on {{volumeStyle}} volume {{nasContainerIdIntegerName}}. Description: NFS access denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} tried to '{{nfsOp}}' on a {{volumeStyle}} NAS volume {{nasContainerIdIntegerName}}, file {{dsidPath}}. [[nl]] Choosing a volume security style dictates which protocol will be used to set permissions on files in this volume. This also sets certain limitations on operations which are not allowed for this security style: [[nl]]1. Setting an ACL for a file in a NAS volume defined with UNIX Security style. [[nl]]2. Setting mode for a file in a NAS volume defined with NTFS Security style. [[nl]]3. Changing the read-only flag for a file in a NAS volume defined with UNIX Security style. [[nl]]4. Setting SID/GSID ownership on UNIX Security style [[nl]]5. Setting UID/GID ownership on NTFS Security style. [[nl]]A user might try to perform one of the above actions and get an 'Access denied' error without understanding why. Action Items: The NAS Volume security style should be chosen according to the main intended usage. If a user needs to perform a security related activity which is forbidden, consider splitting the data into two separate NAS Volumes based on the access pattern. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.105 |
fluidFSEventClientAccessNotAnOwnerNFS access denied. User {{nfsUserName}} not owner of file. Description: NFS Access Denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} can't perform owner restricted operation {{nfsOp}} on file {{dsidPath}}, NAS Volume {{nasContainerIdIntegerName}}, file owner {{userOwnerName}} : {{groupOwnerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.106 |
fluidFSEventClientAccessGiveUidOwnershipAwayDeniedNFS access denied. Root privileges needed to give ownership. Description: NFS Access Denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} can't give ownership away by operation {{nfsOp}} on file {{dsidPath}} to {{userOwnerName}} because root privileges are required for that, NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.107 |
fluidFSEventClientAccessGiveGidOwnershipAwayDeniedNFS access denied. Root privileges needed to give ownership. Description: NFS Access Denied: User {{nfsUserName}} accessing from client {{clientIpAddr}} can't give ownership away by operation {{nfsOp}} on file {{dsidPath}} to {{groupOwnerName}} because root privileges are required for that, NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.108 |
fluidFSEventClientAccessOwnerOfDifferentTypesNFS access denied. File and group owner are inconsistent. Description: NFS Access Denied: both file owner and group owner must be from the same identity type (NTFS vs UNIX), attempt to set different identity types was detected. Client {{clientIpAddr}} User: {{nfsUserName}}, file {{dsidPath}} on NAS Volume {{nasContainerIdIntegerName}}, setting ownership: {{userOwnerName}} ({{userIdentityType}}) : {{groupOwnerName}} ({{groupIdentityType}}). Action Items: It is impossible to change file owner id to UID if the original file ownership is SID/GSID. If the user wants to change the ownership of the file to UNIX ownership, he must set UID and GID at same time. For example: user chown michael:group and not chown michael. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.109 |
fluidFSEventClientAccessCifsOpNotAllowedDueVolumeStyleSMB access denied. Operation not permitted on {{volumeStyle}} volume. Description: Access Denied: User {{nfsUserName}} tried to '{{nfsOp}}' on a {{volumeStyle}} NAS Volume {{nasContainerIdIntegerName}}, file {{dsidPath}}. [[nl]]Choosing a volume security style dictates which protocol will be used to set permissions on files in this volume. This also sets certain limitations on operations which are not allowed for this security style: [[nl]]1. Setting an ACL for a file in a NAS volume defined with UNIX Security style. [[nl]]2. Setting mode for a file in a NAS volume defined with NTFS Security style. [[nl]]3. Changing the read-only flag for a file in a NAS volume defined with UNIX Security style. [[nl]]4. Setting SID/GSID ownership on UNIX Security style [[nl]]5. Setting UID/GID ownership on NTFS Security style. [[nl]]A user might try to perform one of the above actions and get an 'Access denied' error without understanding why. Action Items: The NAS Volume security style should be chosen according to the main intended usage. If a user needs to perform a security related activity which is forbidden, consider splitting the data into two separate NAS Volumes based on the access pattern. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.110 |
fluidFSEventClientAccessConnectionFailurePermissionDeniedShare {{cifsShare}} ACL's denied access to user {{userName}}. Description: Connection for user '{{userName}}' to share {{cifsShare}} denied due to share ACL permissions, client {{clientIpAddr}}, NAS Controller {{nasControllerId}}, NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.111 |
fluidFSEventClientAccessGeneralAccessDeniedAccess denied. Insufficient permissions, user {{userName}}. Description: Access denied on '{{cifsOp}}' operation. Desired access mask: {{desiredCifsAccessMaskName}}, missing bits: {{missedCifsAccessBitsName}}, client: {{clientIpAddr}}, user: {{userName}}, file '{{dsidPath}}' on NAS Volume {{nasContainerIdIntegerName}}. Internal Information: {{internalInfo}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.112 |
fluidFSEventClientAccessNfs4WritePseudoFSWrite Access to pseudo-fs of {{TenantName}}, user {{userName}}. Description: Write Access denied to user {{userName}}. Attempted modification of NFS4 Pseudo File System of {{TenantName}}). Client IP: {{clientIpAddr}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.113 |
fluidFSEventClientAccessAccessDeniedOpenModeConflictAccess Denied. Open mode conflict; user {{userName}}. Description: Access Denied on '{{operation}}' operation due open mode conflict. Desired access mask: {{desiredCifsAccessMaskName}}, open mode mask: {{openModeAccessBitsName}}, client: {{clientIpAddr}}, user: {{userName}}, file '{{dsidPath}}' on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.114 |
fluidFSEventClientAccessAccessDeniedShareModeConflictAccess Denied. Conflict with share mode; NAS Volume {{nasContainerIdIntegerName}}. Description: Access Denied: User {{userName}} accessing from client {{clientIpAddr}} tried to open file {{dsidPath}} on NAS Volume {{nasContainerIdIntegerName}}, which is opened with conflicting share mode by another user. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.115 |
fluidFSEventClientAccessDeleteOnCloseIsSetAccess denied. File marked for deletion; File {{dsidPath}}. Description: Access denied: the file is marked for deletion. Client: {{clientIpAddr}}, user: {{userName}}, file {{dsidPath}} on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.116 |
fluidFSEventClientAccessUserPasswordExpiredSMB client login to {{TenantName}} failed. Password expired for user {{userName}}. Description: SMB client login failure: Password expired for client {{clientIpAddr}} user name '{{userName}}'. NAS Controller {{nasControllerId}} of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.117 |
fluidFSEventClientAccessNoSuchUserSMB client login to {{TenantName}} failed. The user {{userName}} could not be found. Description: SMB client login failure: The login username '{{userName}}' could not be found for client {{clientIpAddr}}. NAS Controller {{nasControllerId}} of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.118 |
fluidFSEventClientAccessCifsAccessDeniedDueShareLevelPerms2Share-level permissions denied access; share {{cifsShare}}. Description: SMB access denied on '{{cifsOp}}' operation: share-level permission applied for the share {{cifsShare}} prohibits such actions. Desired access mask: {{desiredCifsAccessMaskName}}, client: {{clientIpAddr}}, user: {{userName}}, file '{{nasContainerPath}}' on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.119 |
fluidFSEventClientAccessCifsDotSnapshotsAccessDeniedDueToRestrictionSnapshot Access denied due to restriction Description: SMB snapshot access to share {{cifsShare}} was denied due to '.snapshots' restriction. client: {{clientIpAddr}}, user: {{userName}}, file '{{nasContainerPath}}' on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.120 |
fluidFSEventClientAccessNfsDotSnapshotsAccessDeniedDueToRestrictionSnapshot Access denied due to restriction Description: NFS snapshot access to file: {{nasContainerIdIntegerName}}/{{dsidPath}} for user {{nfsUserName}} was denied due to '.snapshots' restriction. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.121 |
fluidFSEventClientAccessCifsUserHasNoPrivileges2SMB access denied. User {{cifsUser2Name}} has insufficient privileges. Description: SMB access denied: accessing user does not have required privileges {{cifsPrivileges}} to perform '{{cifsOp}}', client: {{clientIpAddr}}, user: {{cifsUser2Name}}, file '{{nasContainerPath}}' on NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.122 |
fluidFSEventClientAccessCifsUserHasNoPrivileges3SMB access denied. User {{cifsUser2Name}} has insufficient privileges Description: SMB access denied: accessing user does not have required privileges {{cifsPrivileges}} to perform '{{cifsOp}}', client: {{clientIpAddr}}, user: {{cifsUser2Name}}, file '{{dsidPath}}' on NAS Volume {{nasContainerIdIntegerName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.123 |
fluidFSEventClientAccessNestedNetgroupNotFoundMissing netgroup '{{netgroupName}}' could not be found by {{TenantName}}. Description: Nested netgroup '{{netgroupName}}' of parent netgroup '{{parentNetgroupName}}' was not found while resolving recursive definitions of export access list during NFS mount operation on {{TenantName}}. Missing netgroup was ignored. Action Items: Please check the content of the NIS/LDAP external repository and fix the definition of broken netgroup. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.124 |
fluidFSEventClientAccessNetgroupRecursionIsTooDeepNetgroup '{{netgroupName}}' has too many levels of nesting on {{TenantName}}. Description: Circular netgroup definitions alert: netgroup has too many levels of nesting. Netgroup '{{netgroupName}}' exceeded the limit of {{netgroupThreshold}} levels of nesting on {{TenantName}}. Action Items: Consider reviewing your NIS/LDAP external repository for circular netgroup definitions. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.125 |
fluidFSEventClientAccessSMBMemThreshold3Due to SMB high memory access denied on open file operation Description: SMB access denied on open file operation for user: {{cifsUser2Name}}, file '{{nasContainerPath}}' on NAS Volume {{nasContainerIdIntegerName}} due to SMB high memory consumption on NAS controller {{nasControllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.126 |
fluidFSEventClientAccessSMBMemThreshold4Due to SMB high resource usage new sessions not allowed. Description: Due to SMB high resource usage new sessions are not allowed on NAS controller {{nasControllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.127 |
fluidFSEventClientAccessRpcSecGssAuthFailureNFS RPCSECGSS user authentication failure for user {{userName}} on {{TenantName}}. Description: NFS RPCSECGSS authentication for user '{{userName}}' failed, client {{clientIpAddr}}, NAS controller {{nasControllerId}} of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.128 |
fluidFSEventClientAccessSMBMaxOpenFilesThresholdDue to SMB too many open files denied open file operation. Description: SMB access denied on open file operation due to SMB too many open files on NAS controller {{nasControllerId}}. Allowed number of open files per node is {{maxOpenFilesPerNode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.129 |
fluidFSEventClientAccessExtensionIsDeniedOnShareSMB access denied. Extension {{fileExtension}} is denied on share {{cifsShare}}. Description: SMB access denied: Extension based access is configured on share {{cifsShare}} on NAS volume {{nasContainerIdIntegerName}}, and extension {{fileExtension}} of file {{nasContainerPath}} is denied. User {{cifsUser2Name}} is not a member of the users groups to be excluded from filtering. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.130 |
fluidFSEventClientAccessAutoHomeDirCreationErrorError on creation home directory for user {{cifsUser2Name}}. Description: Auto home directory creation failed for user {{cifsUser2Name}} on NAS volume {{nasContainerIdIntegerName}} with path {{nasContainerPath}}. NT error code {{cifsErrorCode}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.131 |
fluidFSEventClientAccessMountDeniedOnVipNFS mount Denied. Path denied {{mountPath}} on subnet {{clusterVIP}} Description: NFS client {{clientIpAddr}} was trying to mount NFS export with path {{mountPath}} via cluster VIP {{clusterVIP}} but access from this subnet is not allowed by this NFS export. Access was denied. Client was accessing the export in blind mode that can be considered as security issue. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.132 |
fluidFSEventClientAccessCifsTreeConnectDeniedOnVipAccess from disallowed subnet to share {{cifsShare}} was denied Description: Connection for user '{{userName}}' to share {{cifsShare}} denied because access from this subnet is not allowed by SMB share settings, client {{clientIpAddr}}, NAS Controller {{nasControllerId}}, NAS Volume {{nasContainerIdIntegerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.133 |
fluidFSEventClientAccessNoRootForOperationNFS access denied. Root privileges on export needed for {{operation}}. Description: NFS Access Denied: Client {{clientIpAddr}} can't execute operation {{operation}} with volume {{nasContainerIdIntegerName}} because root privileges are required for the client in the relevant NFS export. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.134 |
fluidFSEventClientAccessFtpLoginFailedFTP user log-in to {{TenantName}} failed Description: FTP access to {{TenantName}} from {{clientIpAddr}} is denied for user {{userName}}. Action Items: When the client attempts FTP connection but provides bad account details, this event is generated. Possible reasons: wrong password, bad username, disabled anonymous access, account is disabled, password is expired and needs to be changed. The user should verify account details. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.135 |
fluidFSEventClientAccessFtpLoginAccountProblemFTP user log-in to {{TenantName}} failed due to problematic account Description: FTP client {{clientIpAddr}} user {{userName}} log-in to {{TenantName}} failed due to problematic account Action Items: When the client makes FTP connection but provided account has problems, this event is generated. Possible reasons: account is locked, account is expired, logon with this account is disabled. System administrator might provide support to the user to fix the account problem. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.136 |
fluidFSEventClientAccessFtpLoginInternalProblemFTP user log-in to {{TenantName}} failed due to an internal problem Description: FTP client {{clientIpAddr}} user {{userName}} log-in to {{TenantName}} failed due to internal problem Internal Information: {{internalInfo}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.137 |
fluidFSEventClientAccessFtpLoginSucceededFTP user logged into {{TenantName}} Description: FTP client {{clientIpAddr}} user {{userName}} logged into {{TenantName}} Action Items: When the client makes FTP connection and successfully logs in, this event is generated NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.138 |
fluidFSEventClientAccessFtpAnonymousLoggedInFTP Anonymous user logged into {{TenantName}} Description: FTP Anonymous user logged into {{TenantName}} with email {{userEmail}} from {{clientIpAddr}}. Action Items: We register an event for every anonymous user logins. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.139 |
fluidFSEventClientAccessFtpTlsHandshakeVerMismatchFTP user log-in to {{TenantName}} failed due to wrong TLS version Description: FTP client {{clientIpAddr}} log-in to {{TenantName}} failed due to TLS protocol version mismatch Action Items: Please make sure FTP client software supports encryption method version TLS 1.{{tlsVersion}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.140 |
fluidFSEventClientAccessMaxFtpConnectionsReachedReached Maximum FTP connections on NAS controller {{nasControllerId}} of {{TenantName}}. Maximum connection allowed per controller is {{maxConnections}} Action Items: This failure is common when there are too many FTP connections to the same fsd. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.141 |
fluidFSEventClientAccessFtpMissingBaseLandingDirFTP user log-in to {{TenantName}} failed due to missing landing path Description: FTP client {{clientIpAddr}} user {{userName}} log-in to {{TenantName}} failed due to missing landing directory '{{baseLandingPath}}' on volume {{nasContainerIdIntegerName}}}. Action Items: When the client makes FTP connection and successfully logs in but landing directory does not exist, this event is generated. Please create the landing directory. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.142 |
fluidFSEventClientAccessFtpMissingHomeLandingDirFTP user log-in to {{TenantName}} failed due to missing home landing path Description: FTP client {{clientIpAddr}} user {{userName}} log-in to {{TenantName}} failed due to missing home directory '{{suffixLandingPath}}' within base landing directory '{{baseLandingPath}}' on volume {{nasContainerIdIntegerName}} Action Items: When the client makes FTP connection and successfully logs in but home landing directory does not exist, this event is generated. FTP does not create home folders automatically. Please create them manually. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.143 |
fluidFSEventClientAccessHdfsMaxConnectionsReachedReached maximum HDFS connections Description: Reached Maximum HDFS connections. Action Items: This failure is common when there are too many HDFS connections to the same fsd. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.144 |
fluidFSEventClientAccessHdfsUserNotFoundHDFS user name was not found in any of the repositories of {{TenantName}} Description: HDFS access from {{clientIpAddr}} provided the user name {{userName}}, but a corresponding user was not found in any of the repositories of {{TenantName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.145 |
fluidFSEventClientAccessHdfsDotSnapshotsAccessDeniedDueToRestrictionSnapshot Access denied by {{TenantName}} due to restriction Description: Snapshot access to the HDFS landing directory of NAS Volume {{nasContainerIdIntegerName}} of {{TenantName}} was denied due to '.snapshots' restriction. client: {{clientIpAddr}}, user: {{userName}}, path: '{{baseLandingPath}}'. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.146 |
fluidFSEventClientAccessGpoExecutionTimeoutFailureGPO Policy was not applied on {{TenantName}}. Took too much time. Description: Policy {{policyGuid}} {{policyName}} was not applied on {{TenantName}}. Took to much time. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.147 |
fluidFSEventClientAccessGpoOtherFailureGPO Policy was not applied on {{TenantName}} due to system error. Description: Policy {{policyGuid}} {{policyName}} was not applied on {{TenantName}} due to system error. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.148 |
fluidFSEventClientAccessGpoSuccessGPO Policy was applied successfully on {{TenantName}}. Description: Policy {{policyGuid}} {{policyName}} was applied successfully on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.149 |
fluidFSEventClientAccessGpoFileSecurityPolicyFailureGPO Policy on target on {{TenantName}} was not applied due to system error Description: Policy {{policyGuid}} {{policyName}} on target {{policyTargetPath}} was not applied due to system error on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.150 |
fluidFSEventClientAccessGpoFileSecurityPolicyDoNotReplaceFailureGPO Do Not Replace was not applied on {{TenantName}} due to system error. Description: Do not replace logic was not applied in Policy {{policyGuid}} {{policyName}} on target {{policyTargetPath}} due to system error on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.151 |
fluidFSEventClientAccessGpoInfFileReadFailureGPO Policy .inf file read failure on {{TenantName}}. Description: {{TenantName}} failed to read the .inf file {{filePath}} of the Policy {{policyGuid}} {{policyName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.152 |
fluidFSEventClientAccessCapLdapQueryFailureCentral Access Policy LDAP query failure on {{TenantName}}. Description: LDAP query for Central Access Policy objects {{searchedObjects}} failed on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.153 |
fluidFSEventClientAccessCapCentralAccessRuleParsingFailureCentral Access Policy rule parsing failure on {{TenantName}}. Description: Parsing of the Central Access Policy rule {{ruleDN}} of the policy {{policyDN}} failed on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.154 |
fluidFSEventClientAccessCapCentralAccessPolicyParsingFailureCentral Access policy parsing failure on {{TenantName}}. Description: Parsing of the Central Access policy {{policyDN}} failed on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.11.155 |
fluidFSEventsLicensing OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.13 |
fluidFSEventLicensingEulaNotApprovedByUserEnd-user license agreement (EULA) was not accepted by user. Description: FluidFS version {{FluidFsVersion}} has a new end user license agreement. You must accept this agreement in order to use the system. Action Items: To accept the end user agreement go to User Interface System menu. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.13.14 |
fluidFSEventsExaminer OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.14 |
fluidFSEventExaminerSystemCorruptionFluidFS Health Scan found an inconsistency in the system. Description: FluidFS Health Scan found an inconsistency in the system. Please contact Support. Internal Information: FluidFS Health Scan has found an error in {{category}} on level {{level}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.14.1 |
fluidFSEventExaminerExaminingCycleFinishedFluidFS Health Scan finished a scanning cycle. Description: FluidFS Health Scan finished a scanning cycle of the entire system NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.14.3 |
fluidFSEventsComponent OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.15 |
fluidFSEventComponentExampleCreateSuccessExample {{Name}} was created by {{userName}}. Result: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.3 |
fluidFSEventComponentExampleCreateFailedFailed to create Example {{Name}} by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.4 |
fluidFSEventComponentExampleCreateWarningExample {{Name}} was created by {{userName}}, but with a warning: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.5 |
fluidFSEventComponentExampleModifySuccessExample {{Name}} was modified by {{userName}}. Result: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.6 |
fluidFSEventComponentExampleModifyFailedFailed to modify Example {{Name}} by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.7 |
fluidFSEventComponentExampleModifyWarningExample {{Name}} was modified by {{userName}}, but with a warning: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.8 |
fluidFSEventComponentExampleDeleteSuccessExample {{Name}} was deleted by {{userName}}. Result: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.9 |
fluidFSEventComponentExampleDeleteFailedFailed to delete {{Name}} by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.10 |
fluidFSEventComponentExampleDeleteWarningExample {{Name}} was deleted by {{userName}}, but with a warning: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.11 |
fluidFSEventComponentTimeModifySuccessTime configuration was modified by {{userName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.12 |
fluidFSEventComponentTimeModifyFailedFailed to modify time configuration by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.13 |
fluidFSEventComponentRouteRulesCreateSuccessRoute to {{destinationNetworkID}}/{{destinationPrefix}} with gateway IP {{routeGateway}} was successfully created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.14 |
fluidFSEventComponentSnmpModifySuccessSNMP configuration was modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.15 |
fluidFSEventComponentSnmpModifyFailedFailed to modify SNMP by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.16 |
fluidFSEventComponentRouteRulesModifySuccessRoute to {{destinationNetworkID}}/{{destinationPrefix}} with gateway IP {{routeGateway}} was successfully modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.30 |
fluidFSEventComponentMailConfModifySuccessMail configuration was modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.31 |
fluidFSEventComponentSystemServiceModeChangedSuccessThe System Service Mode is changed to {{systemServiceState}}. Description: The System Service Mode is changed to {{systemServiceState}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.32 |
fluidFSEventComponentSystemServiceModeChangedFailedFailed to change System Service Mode. Description: The System Service Mode failed to be changed to {{systemServiceState}}: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.35 |
fluidFSEventComponentNasAppliancesCreateSuccessNAS Appliance {{applianceId}} ({{applianceServiceTag}}) was successfully created by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.36 |
fluidFSEventComponentNasAppliancesCreateFailedNAS Appliance {{applianceId}} ({{applianceServiceTag}}) could not be created by user {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.37 |
fluidFSEventComponentNasAppliancesModifySuccessNAS Appliance {{applianceId}} ({{applianceServiceTag}}) was successfully modified by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.38 |
fluidFSEventComponentNasAppliancesModifyFailedNAS Appliance {{applianceId}} ({{applianceServiceTag}}) could not be modified by user {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.39 |
fluidFSEventComponentNasAppliancesDeleteSuccessNAS Appliance {{applianceId}} ({{applianceServiceTag}}) was successfully deleted by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.40 |
fluidFSEventComponentNasAppliancesDeleteFailedNAS Appliance {{applianceId}} ({{applianceServiceTag}}) could not be deleted by user {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.41 |
fluidFSEventComponentRestoreClusterCompletedSuccessfullyThe configuration of the cluster was restored successfully by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.42 |
fluidFSEventComponentRestoreClusterFinishedWithErrorsRestore of cluster configuration finished with errors. Description: The configuration of the cluster was restored by user {{userName}} with errors: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.43 |
fluidFSEventComponentRestoreSystemCompletedSuccessfullyThe configuration of the system was restored successfully by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.44 |
fluidFSEventComponentRestoreSystemFinishedWithErrorsRestore of system configuration finished with errors. Description: The configuration of the system was restored by user {{userName}} with errors: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.45 |
fluidFSEventComponentRestoreSystemFromFilesCompletedSuccessfullyThe configuration of the system was restored from files successfully by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.48 |
fluidFSEventComponentRestoreSystemFromFilesFinishedWithErrorsRestore of system configuration finished with errors. Description: The configuration of the system was restored from files by user {{userName}} with errors: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.49 |
fluidFSEventComponentStorageSubsystemCreateSuccessNAS pool was successfully created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.62 |
fluidFSEventComponentStorageSubsystemCreateFailedNAS pool could not be created by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.63 |
fluidFSEventComponentStorageSubsystemModifySuccessNAS pool was successfully expanded by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.64 |
fluidFSEventComponentStorageSubsystemModifyFailedNAS pool could not be expanded by {{userName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.65 |
fluidFSEventComponentAuthenticateAdministratorFailureUser {{Domain}}\{{Name}} failed login to FluidFS {{UserInterfaceType}} from {{UserInterfaceClient}} client. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.72 |
fluidFSEventComponentServicePackRunSuccessEvent{{userName}} successfully upgraded with service pack file {{servicePackFileName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.73 |
fluidFSEventComponentServicePackRunFailedEvent{{userName}} failed upgrade with service pack file {{servicePackFileName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.74 |
fluidFSEventComponentEulaApproveSuccessEvent{{userName}} approved the EULA. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.75 |
fluidFSEventComponentAuthenticateAdministratorSuccessUser {{Domain}}\{{Name}} logged in to FluidFS {{UserInterfaceType}} from {{UserInterfaceClient}} client. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.76 |
fluidFSEventComponentSetCurrentTimeActionEvent{{userName}} changed the current time. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.77 |
fluidFSEventComponentDataReductionConfigurationModifySuccessThe user {{userName}} updated the configuration of Data Reduction schedule policy. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.79 |
fluidFSEventComponentClientNetworkInterfaceModifySuccessClient network interface was successfully modified to MTU {{clientNetworkInterfaceMtu}} and bonding mode {{clientNetworkInterfaceBondMode}} by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.93 |
fluidFSEventComponentEqlFabricCreateSuccessEQL fabric created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.94 |
fluidFSEventComponentEqlFabricCreateWarningEQL fabric created by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.95 |
fluidFSEventComponentEqlFabricModifySuccessEQL fabric modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.96 |
fluidFSEventComponentEqlFabricModifyWarningEQL fabric modified by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.97 |
fluidFSEventComponentEqlFabricDeleteSuccessEQL fabric deleted by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.98 |
fluidFSEventComponentEqlFabricRoutesCreateSuccessEQL fabric route {{networkId}} created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.99 |
fluidFSEventComponentEqlFabricRoutesModifySuccessEQL fabric route {{networkId}} modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.100 |
fluidFSEventComponentEqlFabricRoutesDeleteSuccessEQL fabric route {{networkId}} deleted by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.101 |
fluidFSEventComponentFabricIscsiV4CreateSuccessiSCSI IPv4 fabric {{Name}} created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.102 |
fluidFSEventComponentFabricIscsiV4CreateWarningiSCSI IPv4 fabric {{Name}} created by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.103 |
fluidFSEventComponentFabricIscsiV4ModifySuccessiSCSI IPv4 fabric {{Name}} modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.104 |
fluidFSEventComponentFabricIscsiV4ModifyWarningiSCSI IPv4 fabric {{Name}} modified by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.105 |
fluidFSEventComponentFabricIscsiV4DeleteSuccessiSCSI IPv4 fabric {{Name}} deleted by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.106 |
fluidFSEventComponentStorageEqlGroupModifySuccessEQL storage group modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.107 |
fluidFSEventComponentStorageIscsiPortalsModifySuccessiSCSI storage portals modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.108 |
fluidFSEventComponentStorageIscsiPortalsModifyFailureFailure to modify iSCSI storage portals by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.109 |
fluidFSEventComponentNasApplianceBlinkSuccessUser {{userName}} set the appliance ID {{applianceId}} blink state for the 1st controller to {{blink1}} and the 2nd controller to {{blink2}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.122 |
fluidFSEventComponentRebootNasControllerSuccessUser {{userName}} rebooted NAS controller {{controllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.123 |
fluidFSEventComponentMoveClientActionSuccessClient or router with {{ClientIp}} IP, which referred to {{AccessIp}} IP, was moved to controller{{NodeId}} by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.124 |
fluidFSEventComponentPinClientActionSuccessClient or router with {{ClientIp}} IP, which referred to {{AccessIp}} IP was restricted to the required controller (pin state is {{PinState}}) by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.125 |
fluidFSEventComponentClientLoadBalancingMassFailbackSuccess{{userName}} had performed failback of all the clients to their preferred controller. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.126 |
fluidFSEventComponentClientLoadBalancingMassRebalancingSuccess{{userName}} had performed a rebalance of all the clients between the controllers. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.127 |
fluidFSEventComponentNDMPConfigurationModifySuccessNDMP configuration was modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.128 |
fluidFSEventComponentAntiVirusHostsModifySuccessThe user {{userName}} updated the antivirus hosts. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.134 |
fluidFSEventComponentClusterIdModifySuccessThe user {{userName}} updated the cluster identifier. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.136 |
fluidFSEventComponentClusterNameModifySuccessThe user {{userName}} renamed the cluster to {{ClusterName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.137 |
fluidFSEventComponentBackupConfigurationObjectsToFileSuccessThe user {{userName}} backed up the cluster configuration to file. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.138 |
fluidFSEventComponentDestroyClusterSuccessThe user {{userName}} destroyed the cluster. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.140 |
fluidFSEventComponentEMRecipientsModifySuccessThe user {{userName}} updated the Enterprise Manager recipients. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.141 |
fluidFSEventComponentFabricFcCreateSuccessThe user {{userName}} created {{FabricName}} Fibre Channel fabric. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.142 |
fluidFSEventComponentFabricFcModifySuccessThe user {{userName}} updated {{FabricName}} Fibre Channel fabric. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.143 |
fluidFSEventComponentFabricFcDeleteSuccessThe user {{userName}} deleted {{FabricName}} Fibre Channel fabric. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.144 |
fluidFSEventComponentFTPConfigurationModifySuccessThe user {{userName}} updated the FTP configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.147 |
fluidFSEventComponentHealthScanConfigurationModifySuccessThe user {{userName}} updated the file system health scan configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.148 |
fluidFSEventComponentLanguageModifySuccessThe user {{userName}} updated the language of the cluster. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.150 |
fluidFSEventComponentLogoffActiveNdmpSessionSuccessThe user {{userName}} killed {{NDMPSessionId}} NDMP session on NAS controller{{controllerId}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.152 |
fluidFSEventComponentNasPoolConfigurationModifySuccessThe user {{userName}} updated the NAS pool thresholds. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.154 |
fluidFSEventComponentSupportAccessModifySuccessThe user {{userName}} updated the support access settings. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.155 |
fluidFSEventComponentSystemConfigurationStateModifySuccessThe user {{userName}} updated the system configuration state. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.156 |
fluidFSEventComponentTriggerFabricDiscoverySuccessThe user {{userName}} triggered LUNs discovery. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.158 |
fluidFSEventComponentTrustedSystemCreateSuccessThe user {{userName}} created partnership with {{PartnerIp}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.159 |
fluidFSEventComponentTrustedSystemModifySuccessThe user {{userName}} updated partnership with {{PartnerIp}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.160 |
fluidFSEventComponentTrustedSystemDeleteSuccessThe user {{userName}} deleted partnership with {{PartnerIp}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.161 |
fluidFSEventComponentUIConfigurationModifySuccessThe user {{userName}} updated the UI settings. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.162 |
fluidFSEventComponentRunFileSystemDiagnosticSuccessThe user {{userName}} ran core file system diagnostic. Description: The user {{userName}} ran core file system diagnostic. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.170 |
fluidFSEventComponentRunGeneralSystemDiagnosticSuccessThe user {{userName}} ran general system diagnostic. Description: The user {{userName}} ran general system diagnostic. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.171 |
fluidFSEventComponentRunNetworkDiagnosticSuccessThe user {{userName}} ran networking diagnostic. Description: The user {{userName}} ran networking diagnostic.[[nl]]Diagnostic arguments:[[nl]]ClientIP - {{RunNetworkDiagnosticClientIP}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.172 |
fluidFSEventComponentRunPerformanceDiagnosticSuccessThe user {{userName}} ran performance diagnostic. Description: The user {{userName}} ran performance diagnostic.[[nl]]Diagnostic arguments:[[nl]]FSID - {{RunPerformanceDiagnosticFSID}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.174 |
fluidFSEventComponentRunFileSystemDiagnosticActionFailureFile System diagnostic failed. Description: File System diagnostic, which was run by user {{userName}} failed.[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.178 |
fluidFSEventComponentRunGeneralSystemDiagnosticActionFailureGeneral System diagnostic failed. Description: General System diagnostic, which was run by user {{userName}} failed.[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.179 |
fluidFSEventComponentRunNetworkDiagnosticActionFailureNetwork diagnostic failed. Description: Network diagnostic, which was run by user {{userName}} failed.[[nl]]Diagnostic arguments:[[nl]]ClientIP - {{RunNetworkDiagnosticClientIP}}[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.180 |
fluidFSEventComponentRunPerformanceDiagnosticActionFailurePerformance diagnostic failed. Description: Performance diagnostic, which was run by user {{userName}} failed.[[nl]]Diagnostic arguments:[[nl]]FSID - {{RunPerformanceDiagnosticFSID}}[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.182 |
fluidFSEventComponentFileSystemCoreDiagnosticsFailedFailed to generate diagnostics package for 'FileSystemCoreDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.189 |
fluidFSEventComponentFileSystemCoreDiagnosticsFailesOkPackage generation for 'FileSystemCoreDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.190 |
fluidFSEventComponentGeneralSystemDiagnosticsFailedFailed to generate diagnostics package for 'GeneralSystemDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.191 |
fluidFSEventComponentGeneralSystemDiagnosticsOkPackage generation for 'GeneralSystemDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.192 |
fluidFSEventComponentNetworkDiagnosticsFailedFailed to generate diagnostics package for 'NetworkDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.193 |
fluidFSEventComponentNetworkDiagnosticsOkPackage generation for 'NetworkDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.194 |
fluidFSEventComponentPerformanceDiagnosticsFailedFailed to generate diagnostics package for 'PerformanceDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.197 |
fluidFSEventComponentPerformanceDiagnosticsOkPackage generation for 'PerformanceDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.198 |
fluidFSEventComponentExampleCreateStartExample {{Name}} create started by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.201 |
fluidFSEventComponentPostUpgradeActionsEventSystem was successfully upgraded to version {{servicePackVersion}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.203 |
fluidFSEventComponentRouteRulesDeleteSuccessRoute to {{destinationNetworkID}}/{{destinationPrefix}} with gateway IP {{routeGateway}} was successfully deleted by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.204 |
fluidFSEventComponentSecureConsoleAccessModifySuccessThe user {{userName}} had modified the Secure Console Access settings Description: The user {{userName}} had modified the Secure Console Access settings NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.205 |
fluidFSEventComponentSecureConsoleAccessModifyFailure{{userName}} failed to modify the Secure Console Access settings Description: The user {{userName}} had failed to modify the Secure Console Access settings due to the following error: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.206 |
fluidFSEventComponentSecureConsoleAccessModifyWarning{{userName}} failed to modify the Secure Console Access settings Description: The user {{userName}} had failed to modify the Secure Console Access settings due to the following error: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.207 |
fluidFSEventComponentExampleBackgroundCreateSuccessExampleBackground {{Name}} was created . NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.209 |
fluidFSEventComponentFilesystemCreatedStartingDomainMigrationThe NAS appliance is now part of the file-system. Starting resource optimization using domain migration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.211 |
fluidFSEventComponentStartingJoinNASApplianceThe system is starting to join the NAS appliance to the file-system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.212 |
fluidFSEventComponentFilesystemCreatedNoDomainMigrationRequiredThe NAS appliance is now part of the file-system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.213 |
fluidFSEventComponentEventsStoreFilterModifySuccessEvents filter configuration was modified by {{userName}} Description: Events filter configuration was modified by {{userName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.214 |
fluidFSEventComponentEventsStoreFilterModifyFailure{{userName}} had failed to modify the Events filter configuration Description: {{userName}} had failed to modify the Events filter configuration. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.215 |
fluidFSEventComponentPhoneHomeModifySuccess{{userName}} updated phone home settings Description: {{userName}} updated phone home settings NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.216 |
fluidFSEventComponentBMCNetworkConfigurationModifySuccessThe user {{userName}} updated the BMC network configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.219 |
fluidFSEventComponentFSStorageConfigurationModifySuccessThe user {{userName}} updated the file system storage configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.220 |
fluidFSEventComponentUpgradeStandbyNodeSuccessEvent{{userName}} successfully flashed standby node with service pack file {{servicePackFileName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.223 |
fluidFSEventComponentUpgradeStandbyNodeFailedEvent{{userName}} failed to flash standby node with service pack file {{servicePackFileName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.224 |
fluidFSEventComponentPostUpgradeActionsWarningEventUpgraded with warnings: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.225 |
fluidFSEventComponentServicePackValidateSuccessEvent{{userName}} successfully validated service pack file {{servicePackFileName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.226 |
fluidFSEventComponentServicePackValidateFailedEvent{{userName}}: Failed validation of service pack file {{servicePackFileName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.227 |
fluidFSEventComponentCloneVMSuccessThe user {{userName}} successfully created {{numberOfClones}} cloned virtual machines from {{sourceVMName}}. on server {{vmWareServerName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.228 |
fluidFSEventComponentCreateVMWareServerSuccessThe user {{userName}} created VMWare server {{vmWareServerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.229 |
fluidFSEventComponentModifyVMWareServerSuccessThe user {{userName}} modified VMWare server {{vmWareServerName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.230 |
fluidFSEventComponentEnableMetadataRedundancyForNewVolumesMetadata redundancy for new NAS volumes was enabled by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.231 |
fluidFSEventComponentDisableMetadataRedundancyForNewVolumesMetadata redundancy for new NAS volumes was disabled by {{userName}}. Be aware that newly created NAS Volumes will be less resistant to failure NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.232 |
fluidFSEventComponentModifyVMWareSettingsSuccessThe user {{userName}} modified VMWare settings NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.234 |
fluidFSEventComponentRunNdmpDiagnosticSuccessThe user {{userName}} ran NDMP diagnostic. Description: The user {{userName}} ran NDMP diagnostic. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.236 |
fluidFSEventComponentRunNdmpDiagnosticActionFailureNdmp diagnostic failed. Description: Ndmp diagnostic, which was run by user {{userName}} failed.[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.237 |
fluidFSEventComponentNdmpDiagnosticsFailedFailed to generate diagnostics package for 'NdmpDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.238 |
fluidFSEventComponentNdmpDiagnosticsOkPackage generation for 'NdmpDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.239 |
fluidFSEventComponentRediscoverLunsSuccessThe system sucessfully triggered iSCSI targets discovery. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.241 |
fluidFSEventComponentFileAccessNotificationConfigModifySuccessFile Access Notification settings updated Description: File Access Notification settings updated NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.247 |
fluidFSEventComponentFileAccessNotificationPolicyModifySuccessFile Access Notification Policy changed Description: File Access Notification Policy changed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.248 |
fluidFSEventComponentFileAccessNotificationSubscriberModifySuccessFile Access Notifications Subscribers changed Description: File Access Notifications Subscribers changed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.249 |
fluidFSEventComponentTapeDeviceConfigurationCreateSuccessThe user {{userName}} created a new tape device with name {{tapeDeviceName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.250 |
fluidFSEventComponentTapeDeviceConfigurationModifySuccessThe user {{userName}} modified a tape device name to {{tapeDeviceName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.251 |
fluidFSEventComponentTapeDeviceConfigurationDeleteSuccessThe user {{userName}} deleted a tape device with name {{tapeDeviceName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.252 |
fluidFSEventComponentInternalStorageReservationSetSuccessThe user {{userName}} set the internal storage reservation Description: The user {{userName}} set the internal storage reservation. Current configuration: events - {{eventsSpace}} MB NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.253 |
fluidFSEventComponentBwLimiterCreateSuccessThe user {{userName}} created Bw Limiter {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.254 |
fluidFSEventComponentBwLimiterModifySuccessThe user {{userName}} updated the configuration of BW Limiter {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.255 |
fluidFSEventComponentBwLimiterDeleteSuccessThe user {{userName}} deleted BW Limiter {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.256 |
fluidFSEventComponentStorageDevicesRescanSuccessEventThe user {{userName}} performed rescan storage devices. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.258 |
fluidFSEventComponentVAppCloningSuccessThe user {{userName}} has successfully cloned VMware Virtual Appliance NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.264 |
fluidFSEventComponentTenantCreateSuccessThe user {{userName}} created Tenant {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.265 |
fluidFSEventComponentTenantModifySuccessThe user {{userName}} updated the configuration of {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.266 |
fluidFSEventComponentTenantDeleteSuccessThe user {{userName}} deleted Tenant {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.267 |
fluidFSEventComponentVirtualVolumeCreateSuccessThe user {{userName}} created NAS volume {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.268 |
fluidFSEventComponentVirtualVolumeModifySuccessThe user {{userName}} updated the configuration of NAS volume {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.269 |
fluidFSEventComponentVirtualVolumeDeleteSuccessThe user {{userName}} deleted NAS volume {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.270 |
fluidFSEventComponentSnapshotsRestoreSuccessThe user {{userName}} restored snapshot {{SnapshotID}} - {{Name}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.271 |
fluidFSEventComponentSnapshotModifySuccessThe user {{userName}} modified snapshot {{SnapshotID}} on NAS volume {{FSIDName}} to name {{Name}} and expiry {{Expiry}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.272 |
fluidFSEventComponentSnapshotModifyFailureThe user {{userName}} failed to rename snapshot {{SnapshotID}} on NAS volume {{FSIDName}} to name {{Name}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.273 |
fluidFSEventComponentSnapshotDeleteSuccessThe user {{userName}} deleted snapshot {{SnapshotID}} - {{Name}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.274 |
fluidFSEventComponentSnapshotDeleteFailureThe user {{userName}} failed to delete snapshot {{SnapshotID}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.275 |
fluidFSEventComponentSnapshotCreateSuccessThe user {{userName}} created snapshot {{SnapshotID}} - {{Name}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.276 |
fluidFSEventComponentSnapshotCreateFailureThe user {{userName}} failed to create snapshot {{SnapshotID}} - {{Name}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.277 |
fluidFSEventComponentSnapshotMakeManualSuccessThe user {{userName}} set NDMP lock on snapshot {{SnapshotID}} on NAS volume {{FSIDName}} to {{NdmpLock}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.278 |
fluidFSEventComponentDnsModifySuccessDNS configuration of {{TenantName}} was modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.279 |
fluidFSEventComponentDnsModifyWarningDNS configuration of {{TenantName}} was modified by {{userName}}. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.280 |
fluidFSEventComponentSnapshotsRestoreSuccessNameSnapshot {{SnapshotID}} - {{Name}} was restored on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.281 |
fluidFSEventComponentSnapshotsRestoreFailureNameSnapshot {{SnapshotID}} - {{Name}} failed to be restored on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.282 |
fluidFSEventComponentRestoreVirtualVolumeCompletedSuccessfullyThe configuration of the NAS volume {{FSIDName}} was restored successfully by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.283 |
fluidFSEventComponentRestoreVirtualVolumeFinishedWithErrorsRestore NAS container configuration {{FSIDName}} finished with errors. Description: The configuration of the NAS container {{FSIDName}} was restored by user {{userName}} with errors: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.284 |
fluidFSEventComponentRestoreVirtualVolumeFromFilesCompletedSuccessfullyThe configuration of the NAS volume {{FSIDName}} was restored from files successfully by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.285 |
fluidFSEventComponentRestoreVirtualVolumeFromFilesFinishedWithErrorsRestore NAS volume {{FSIDName}} configuration finished with errors. Description: The configuration of the NAS volume {{FSIDName}} was restored from files by user {{userName}} with errors: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.286 |
fluidFSEventComponentAdministratorCreateSuccessThe user {{userName}} created new administrator {{AdminName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.287 |
fluidFSEventComponentAdministratorModifySuccessThe user {{userName}} modified the configuration of administrator {{AdminName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.288 |
fluidFSEventComponentAdministratorDeleteSuccessThe user {{userName}} deleted administrator {{AdminName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.289 |
fluidFSEventComponentCifsShareCreateSuccessThe user {{userName}} created the {{shareName}} SMB share on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.290 |
fluidFSEventComponentCifsShareModifySuccessThe user {{userName}} updated the configuration of {{shareName}} SMB share on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.291 |
fluidFSEventComponentCifsShareDeleteSuccessThe user {{userName}} deleted the {{shareName}} SMB share on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.292 |
fluidFSEventComponentCifsHomeShareModifySuccessThe user {{userName}} updated the configuration of home SMB share on {{FSIDName}} NAS volume of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.293 |
fluidFSEventComponentNfsExportCreateSuccessThe user {{userName}} created the {{NFSExportPath}} NFS export on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.294 |
fluidFSEventComponentNfsExportModifySuccessThe user {{userName}} updated the configuration of {{NFSExportPath}} NFS export on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.295 |
fluidFSEventComponentNfsExportDeleteSuccessThe user {{userName}} deleted {{NFSExportPath}} NFS export on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.296 |
fluidFSEventComponentSnapshotScheduleCreateSuccessThe user {{userName}} created the {{Name}} snapshot schedule on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.297 |
fluidFSEventComponentSnapshotScheduleModifySuccessThe user {{userName}} updated the configuration of {{Name}} snapshot schedule on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.298 |
fluidFSEventComponentSnapshotScheduleDeleteSuccessThe user {{userName}} deleted the {{Name}} snapshot schedule on {{FSIDName}} NAS volume. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.299 |
fluidFSEventComponentReplicationScheduleCreateSuccessThe user {{userName}} created the {{Name}} schedule for replication between {{FSIDName}} and {{remoteVolumeName}}@{{remoteClusterName}} NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.300 |
fluidFSEventComponentReplicationScheduleModifySuccessThe user {{userName}} updated the configuration of {{Name}} schedule for replication between {{FSIDName}} and {{remoteVolumeName}}@{{remoteClusterName}} NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.301 |
fluidFSEventComponentReplicationScheduleDeleteSuccessThe user {{userName}} deleted the {{Name}} schedule for replication between {{FSIDName}} and {{remoteVolumeName}}@{{remoteClusterName}} NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.302 |
fluidFSEventComponentSnapshotDeleteSuccessNoNameThe user {{userName}} deleted snapshot {{SnapshotID}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.303 |
fluidFSEventComponentReplicationActionAttachSuccessThe user {{userName}} has connected {{FSIDName}} volume to {{remoteVolume}} volume of {{remoteSystemName}} system. Description: The user {{userName}} has connected NAS volume to {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.304 |
fluidFSEventComponentReplicationActionDetachSuccessThe user {{userName}} has disconnected {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has disconnected the replication between {{FSIDName}} NAS volume and {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.305 |
fluidFSEventComponentReplicationActionPauseSuccessThe user {{userName}} has disabled replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has disabled the replication between {{FSIDName}} NAS volume and {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.306 |
fluidFSEventComponentReplicationActionResumeSuccessThe user {{userName}} has enabled replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has enabled the replication between {{FSIDName}} NAS volume and {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.307 |
fluidFSEventComponentReplicationActionPromoteSuccessThe user {{userName}} has promoted replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has promoted replication between {{FSIDName}} NAS volume and {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.308 |
fluidFSEventComponentReplicationActionDemoteSuccessThe user {{userName}} has demoted replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has demoted replication between {{FSIDName}} NAS volume and {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.309 |
fluidFSEventComponentReplicationActionStartSuccessThe user {{userName}} has started replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. Description: The user {{userName}} has started replication from {{FSIDName}} NAS volume to {{remoteVolume}} NAS volume of {{remoteSystemName}} system. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.310 |
fluidFSEventComponentCreateBlockStorageSuccessBlockStorage {{storageId}} was successfully created. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.311 |
fluidFSEventComponentModifyBlockStorageSuccessClient subnet {{storageId}} was successfully modified. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.312 |
fluidFSEventComponentDeleteBlockStorageSuccessClient subnet {{storageId}} was successfully deleted. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.313 |
fluidFSEventComponentSubnetsCreateSuccessClient subnet {{networkId}}/{{prefix}} was successfully created by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.314 |
fluidFSEventComponentSubnetsModifySuccessClient subnet {{networkId}}/{{prefix}} was successfully modified by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.315 |
fluidFSEventComponentSubnetsDeleteSuccessClient subnet {{networkId}}/{{prefix}} was successfully deleted by {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.316 |
fluidFSEventComponentActiveDirectoryJoinSuccessThe user {{userName}} has successfully joined {{TenantName}} to Active Directory domain '{{Domain}}'. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.317 |
fluidFSEventComponentActiveDirectoryJoinWarningThe user {{userName}} has joined {{TenantName}} to Active Directory domain '{{Domain}}', but with a warning: {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.318 |
fluidFSEventComponentActiveDirectoryLeaveSuccessThe user {{userName}} has successfully left {{TenantName}} from Active Directory domain. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.319 |
fluidFSEventComponentLocalUsersCreateSuccessThe user {{userName}} has successfully added new Local User '{{localAccountName}}' to {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.320 |
fluidFSEventComponentLocalUsersDeleteSuccessThe user {{userName}} has successfully deleted Local User '{{localAccountName}}' from {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.321 |
fluidFSEventComponentLocalUsersModifySuccessThe user {{userName}} has successfully modified Local User '{{localAccountName}}' in {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.322 |
fluidFSEventComponentLocalGroupsCreateSuccessThe user {{userName}} has successfully added new Local Group '{{localAccountName}}' to {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.323 |
fluidFSEventComponentLocalGroupsDeleteSuccessThe user {{userName}} has successfully deleted Local Group '{{localAccountName}}' from {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.324 |
fluidFSEventComponentLocalGroupsModifySuccessThe user {{userName}} has successfully modified Local Group '{{localAccountName}}' in {{TenantName}} cluster repository. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.325 |
fluidFSEventComponentUserDatabaseModifySuccessThe user {{userName}} has successfully re-configured UNIX external repository of {{TenantName}} to use '{{userDatabaseType}}' accounts database. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.326 |
fluidFSEventComponentMappingPolicyModifySuccessThe user {{userName}} has successfully re-configured users mapping policy of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.327 |
fluidFSEventComponentManualMappingsCreateSuccessThe user {{userName}} has successfully added new manual mapping rule between Windows user '{{windowsUserName}}' and UNIX user '{{unixUserName}}' on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.328 |
fluidFSEventComponentManualMappingsDeleteSuccessThe user {{userName}} has successfully deleted manual mapping rule between Windows user '{{windowsUserName}}' and UNIX user '{{unixUserName}}' on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.329 |
fluidFSEventComponentManualMappingsModifySuccessThe user {{userName}} has successfully modified manual mapping rule between Windows user '{{windowsUserName}}' and UNIX user '{{unixUserName}}' on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.330 |
fluidFSEventComponentQuotaRuleCreateSuccessThe user {{userName}} created quota rule on volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.331 |
fluidFSEventComponentQuotaRuleModifySuccessThe user {{userName}} modified quota rule on volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.332 |
fluidFSEventComponentQuotaRuleDeleteSuccessThe user {{userName}} deleted quota rule on volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.333 |
fluidFSEventComponentCifsProtocolModifySuccessThe user {{userName}} updated the general local users settings of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.334 |
fluidFSEventComponentFileCloningSuccessThe user {{userName}} cloned ({{FSIDName}}){{SourceFilePath}} to ({{FSIDName}}){{DestinationDir}}/{{DestinationFileName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.335 |
fluidFSEventComponentFolderCreateSuccessThe user {{userName}} created {{DestinationParentDir}}/{{DestinationDir}} directory on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.336 |
fluidFSEventComponentNfsProtocolModifySuccessThe user {{userName}} updated the general NFS settings of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.337 |
fluidFSEventComponentVirtualVolumeFolderCreateSuccessThe user {{userName}} created {{VirtualVolumeFolderName}} NAS volumes folder on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.338 |
fluidFSEventComponentVirtualVolumeFolderModifySuccessThe user {{userName}} updated {{VirtualVolumeFolderName}} NAS volumes folder on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.339 |
fluidFSEventComponentVirtualVolumeFolderDeleteSuccessThe user {{userName}} deleted {{VirtualVolumeFolderName}} NAS volumes folder on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.340 |
fluidFSEventComponentRunHdfsDiagnosticSuccessThe user {{userName}} ran HDFS diagnostic. Description: The user {{userName}} ran HDFS diagnostic. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.341 |
fluidFSEventComponentRunHdfsDiagnosticActionFailureHdfs diagnostic failed. Description: Hdfs diagnostic, which was run by user {{userName}} failed.[[nl]]{{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.342 |
fluidFSEventComponentReplicationModifyRetPolicyThe user {{userName}} has modified the replication snapshot retention. Description: The user {{userName}} has modified the replication snapshot retention policy for replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.343 |
fluidFSEventComponentHdfsDiagnosticsFailedFailed to generate diagnostics package for 'HdfsDiagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.344 |
fluidFSEventComponentHdfsDiagnosticsOkPackage generation for 'HdfsDiagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.345 |
fluidFSEventComponentActiveDirectoryPreferredDcSuccessThe user {{userName}} has successfully configured preferred domain controllers of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.346 |
fluidFSEventComponentFileCopySuccessThe user {{userName}} copied {{SourceFSIDName}}\{{SourceFilePath}} to {{DestinationFSIDName}}\{{DestinationFilePath}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.347 |
fluidFSEventComponentFileCopyFailureThe user {{userName}} failed to copy {{SourceFSIDName}}\{{SourceFilePath}} to {{DestinationFSIDName}}\{{DestinationFilePath}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.348 |
fluidFSEventComponentLogoffActiveProtocolSessionGeneralSuccessNAS Administrator '{{administrator}}' closed {{ClientProtocol}} connection(s) on {{TenantName}}. Filter details: {{ClientProtocolDetails}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.349 |
fluidFSEventComponentCloseOpenFileGeneralSuccessNAS Administrator '{{administrator}}' closed file(s) on {{TenantName}}. Filter details: {{ClientProtocolDetails}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.350 |
fluidFSEventComponentFlashClusterSuccessEvent{{userName}} successfully flashed cluster with service pack file {{servicePackFileName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.351 |
fluidFSEventComponentFlashClusterFailedEvent{{userName}} failed to flash cluster with service pack file {{servicePackFileName}}. {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.352 |
fluidFSEventComponentSmbShareSecurityDescriptorModifySuccessThe user {{userName}} modified ACL on the root folder of SMB share {{shareName}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.353 |
fluidFSEventComponentRedirectionFolderAddSuccessThe user {{userName}} added redirection on the folder {{FolderPath}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.354 |
fluidFSEventComponentRedirectionFolderModifySuccessThe user {{userName}} modified redirection on the folder {{DSIDPath}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.355 |
fluidFSEventComponentRedirectionFolderDeleteSuccessThe user {{userName}} deleted redirection on the folder {{DSIDPath}} on NAS volume {{FSIDName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.356 |
fluidFSEventComponentFtpProtocolModifySuccessThe user {{userName}} updated the FTP configuration of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.357 |
fluidFSEventComponentReplicationActionModifyBwLimiterSuccessThe user {{userName}} has modified the BW limiter for replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.358 |
fluidFSEventComponentGpoModifySuccessGPO configuration of {{TenantName}} was modified successfully Description: The user {{userName}} has successfully modified the GPO configuration of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.359 |
fluidFSEventComponentGpoTriggerSuccessGroup policy polling was triggered successfully on {{TenantName}} Description: The user {{userName}} has triggered group policy polling successfully on {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.360 |
fluidFSEventComponentTenantPublicIPsModifySuccessThe user {{userName}} updated the configuration of {{TenantName}} client network Public IPs. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.361 |
fluidFSEventComponentReplicationActionModifyCompressionAndDedupSuccessThe user {{userName}} has modifyed the compression and deduplication mode for replication between {{FSIDName}} and {{remoteVolume}}@{{remoteSystemName}} NAS volumes. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.362 |
fluidFSEventComponentExampleActionSyncSuccessExample action with sync succeeded. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.363 |
fluidFSEventComponentExampleActionSyncFailedFailed to perform example action with sync. Error: {{retcodeString}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.364 |
fluidFSEventComponentAdminSubnetModifySuccessManagement subnet {{networkId}}/{{prefix}} was successfully modified by {{userName}}. State is {{state}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.365 |
fluidFSEventComponentTriggerPhoneHomeSuccessThe user {{userName}} triggered phone home. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.366 |
fluidFSEventComponentInterfaceRolesModifySuccessInterface Roles for NAS Appliance {{applianceId}} were successfully modified by user {{userName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.367 |
fluidFSEventComponentSmbDiagnosticOkPackage generation for 'SMB Diagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.368 |
fluidFSEventComponentSmbDiagnosticFailedFailed to generate diagnostics package for 'SMB Diagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.369 |
fluidFSEventComponentNfsDiagnosticOkPackage generation for 'NFS Diagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.370 |
fluidFSEventComponentNfsDiagnosticFailedFailed to generate diagnostics package for 'NFS Diagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.371 |
fluidFSEventComponentFtpDiagnosticOkPackage generation for 'FTP Diagnostics' completed successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.372 |
fluidFSEventComponentFtpDiagnosticFailedFailed to generate diagnostics package for 'FTP Diagnostics'. {{retcodeString}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.373 |
fluidFSEventComponentActiveDirectorySetKrbCompoundAuthSuccessThe user {{userName}} has successfully configured Kerberos Compound Authentication support for the cluster {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.374 |
fluidFSEventComponentHdfsProtocolModifySuccessThe user {{userName}} updated the HDFS configuration of {{TenantName}}. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.15.375 |
fluidFSEventsSupportShell OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.16 |
fluidFSEventSupportShellSecureConsoleAccessDisabledReservationSecure Console Access on NAS Controller {{node}} cannot be enabled Description: Secure Console Access session on NAS Controller {{node}} had been disconnected from the server side or the system is disabled on the reservation web server NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.4 |
fluidFSEventSupportShellSecureConsoleAccessSshTunnelFailureSecure Console Access failure on NAS Controller {{node}} Description: Secure Console Access session on NAS Controller {{node}} had been disconnected due to SSH tunnel failure NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.5 |
fluidFSEventSupportShellSecureConsoleAccessSessionStartFailedFailed to establish the Secure Console Access session Description: Failed to establish the Secure Console Access session on NAS Controller {{node}} due to error response from the reservation web server NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.6 |
fluidFSEventSupportShellSecureConsoleAccessSessionExpiredSecure Console Access session on NAS Controller {{node}} had expired Description: Secure Console Access session on NAS Controller {{node}} had been disconnected due to TTL expiry NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.7 |
fluidFSEventSupportShellSupportShellLoginUser logged-in into Support Shell Description: User {{userName}} logged-in into support shell in NAS Controller {{node}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.8 |
fluidFSEventSupportShellSupportShellLogoutUser logged-out from Support Shell Description: User {{userName}} logged-out from support shell in NAS Controller {{node}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.9 |
fluidFSEventSupportShellSupportShellCommandInvokationUser executed command in Support Shell Description: User {{userName}} executed command {{command}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.16.10 |
fluidFSEventsAuditing OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.17 |
fluidFSEventAuditingSuccessfulAuditWriteSuccessful Write by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful write operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.23 |
fluidFSEventAuditingSuccessfulAuditReadSuccessful Read by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful read operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.24 |
fluidFSEventAuditingSuccessfulAuditDeleteSuccessful Delete by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful delete operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.25 |
fluidFSEventAuditingSuccessfulAuditReadAttrSuccessful Read Attributes by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful read attributes operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.26 |
fluidFSEventAuditingSuccessfulAuditWriteAttrSuccessful Write Attributes by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful write attributes operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.27 |
fluidFSEventAuditingSuccessfulAuditWriteOwnerSuccessful Change Owner by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful change owner operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.28 |
fluidFSEventAuditingSuccessfulAuditWriteDACLSuccessful Change permissions by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful write to DACL operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.29 |
fluidFSEventAuditingSuccessfulAuditAccessSACLSuccessful System Security Access by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful access to SACL operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.30 |
fluidFSEventAuditingSuccessfulAuditReadCtlSuccessful Read Security Descriptor by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a successful read security descriptor operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.31 |
fluidFSEventAuditingFailedAuditWriteFailed Write by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed write operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.32 |
fluidFSEventAuditingFailedAuditReadFailed Read by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed read operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.33 |
fluidFSEventAuditingFailedAuditDeleteFailed Delete by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed delete operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.34 |
fluidFSEventAuditingFailedAuditReadAttrFailed Read Attributes by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed read attributes operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.35 |
fluidFSEventAuditingFailedAuditWriteAttrFailed Write Attributes by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed write attributes operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.36 |
fluidFSEventAuditingFailedAuditWriteOwnerFailed Change Owner by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed change owner operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.37 |
fluidFSEventAuditingFailedAuditWriteDACLFailed Change permissions by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed write to DACL operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.38 |
fluidFSEventAuditingFailedAuditAccessSACLFailed Access to SACL by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed access to SACL operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.39 |
fluidFSEventAuditingFailedAuditReadCtlFailed Read Security Descriptor by {{uName}} on {{nName}}/{{dPath}} Description: The User {{uName}} performed a failed read security descriptor operation on file {{nName}}/{{dPath}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.40 |
fluidFSEventAuditingFailedAuditDeleteNameFailed Delete by {{uName}} on {{nName}}/{{name}} Description: The User {{uName}} performed a failed delete operation on file {{nName}}/{{name}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.41 |
fluidFSEventAuditingSuccessfulAuditDeleteNameSuccessful Delete by {{uName}} on {{nName}}/{{name}} Description: The User {{uName}} performed a successful delete operation on file {{nName}}/{{name}}. The Desired access mask: {{desiredCifsAccessMaskName}} NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.17.42 |
fluidFSEventsUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.20.18 |
fluidFSEventUpgradeFailedToReadFileInformationFail to read information of file {{servicePackName}} while checking for new service pack. File was removed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.1 |
fluidFSEventUpgradeFailedToGetFileSizeFail to get size of file {{servicePackName}} while checking for new service pack. File was removed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.2 |
fluidFSEventUpgradeInvalidFileFormatOrChecksumFile {{servicePackName}} is not a valid package for upgrade. File was removed NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.3 |
fluidFSEventUpgradeServicePackIsOlderThanCurrentVersionThe service pack {{servicePackName}} was removed because its version is older than current one NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.4 |
fluidFSEventUpgradeServicePackHasOldVersionThe service pack {{servicePackName}} was removed because its version is older than available versions on the current node NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.5 |
fluidFSEventUpgradeServicePackAlreadyExistsThe service pack {{servicePackName}} was removed because file with the same version already exists NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.6 |
fluidFSEventUpgradeMonitoringDataCorruptionFailed to recover the monitored data after upgrade because of corruption NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.7 |
fluidFSEventUpgradeServicePackDownloadedNew service pack {{servicePackName}} downloaded NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.20.18.8 |
fluidFSEventsParams OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21 |
fluidFSEventsParamsAdmin OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.1 |
fluidFSEventsParamsAdminUsernameUser name which performed the operationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.1 |
fluidFSEventsParamsAdminAdministratorSystem administratorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.2 |
fluidFSEventsParamsAdminLocaluserLocal user namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.3 |
fluidFSEventsParamsAdminLocalgroupLocal group namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.4 |
fluidFSEventsParamsAdminTenantIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.5 |
fluidFSEventsParamsAdminVirtualVolumeNAS volumero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.6 |
fluidFSEventsParamsAdminHostAntivirus hostro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.7 |
fluidFSEventsParamsAdminPortAntivirus portro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.8 |
fluidFSEventsParamsAdminShareNameSMB share namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.9 |
fluidFSEventsParamsAdminNodeIdNode idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.10 |
fluidFSEventsParamsAdminPidProcess idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.11 |
fluidFSEventsParamsAdminVirtualInterfaceVirtual interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.12 |
fluidFSEventsParamsAdminClusterNameCluster namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.13 |
fluidFSEventsParamsAdminSnapshotNameSnapshot namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.14 |
fluidFSEventsParamsAdminNewSnapshotNameNew snapshot namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.15 |
fluidFSEventsParamsAdminStaticRoutesStatic routes listro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.16 |
fluidFSEventsParamsAdminNFSExportPathPath of NFS exportro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.17 |
fluidFSEventsParamsAdminQuotaUserNameUser name on which the quota is definedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.18 |
fluidFSEventsParamsAdminQuotaGroupNameGroup name on which the quota is definedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.19 |
fluidFSEventsParamsAdminFileLevelReplicationScheduleScheduling configuration of file level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.20 |
fluidFSEventsParamsAdminReplicationSourceSource volume of block level replication (volume@cluster)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.21 |
fluidFSEventsParamsAdminReplicationDestinationDestination volume of block level replication (volume@cluster)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.22 |
fluidFSEventsParamsAdminReplicationSourceVolumeSource volume of block level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.23 |
fluidFSEventsParamsAdminReplicationDestinationVolumeDestination volume of block level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.24 |
fluidFSEventsParamsAdminReplicationDestinationClusterDestination cluster of block level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.25 |
fluidFSEventsParamsAdminFileLevelReplicationTaskTask name of file level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.26 |
fluidFSEventsParamsAdminTrustedClusterTrusted cluster namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.27 |
fluidFSEventsParamsAdminPackageNamePackage namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.28 |
fluidFSEventsParamsAdminCIFSShareNamesCIFSShareNamesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.29 |
fluidFSEventsParamsAdminSubnetNameSubnet namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.30 |
fluidFSEventsParamsAdminSrcUsernameSource user for user mappingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.31 |
fluidFSEventsParamsAdminDstUsernameDestination user for user mappingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.32 |
fluidFSEventsParamsAdminGuestAccountUsernameProtocols guest accountro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.33 |
fluidFSEventsParamsAdminUsersRepositoryTypeUsers repository type (Windows/Unix...)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.34 |
fluidFSEventsParamsAdminComponentThe API componentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.35 |
fluidFSEventsParamsAdminArgsListThe input argumentsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.36 |
fluidFSEventsParamsAdminNodeIdEvenEven Controller idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.37 |
fluidFSEventsParamsAdminNodeIdOddOdd Controller idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.38 |
fluidFSEventsParamsAdminNewSizeSize being added to the FS (GB)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.39 |
fluidFSEventsParamsAdminLunsListList of LUN id'sro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.40 |
fluidFSEventsParamsAdminSpVersionSP Versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.41 |
fluidFSEventsParamsAdminUnsignedNodeIdNode idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.42 |
fluidFSEventsParamsAdminOldSizeCurrent size of the FS (GB)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.43 |
fluidFSEventsParamsAdminSpErrorSP Error reasonro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.44 |
fluidFSEventsParamsAdminGeneralEventTextA general free text parameter, that can be sent to EQL which does not support it yetro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.45 |
fluidFSEventsParamsAdminNewAtimeValueNew value of atime granularityro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.46 |
fluidFSEventsParamsAdminDiagnosticNameThe diagnostic namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.47 |
fluidFSEventsParamsAdminWWNPort1WWN Port1ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.48 |
fluidFSEventsParamsAdminWWNPort2WWN Port2ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.49 |
fluidFSEventsParamsAdminNumLunsNumber of LUNs added to the FSro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.50 |
fluidFSEventsParamsAdminUiThe interface namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.51 |
fluidFSEventsParamsAdminErrCodeInternal code of errorro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.52 |
fluidFSEventsParamsAdminControllerIdController IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.53 |
fluidFSEventsParamsAdminApplianceIdNAS appliance IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.54 |
fluidFSEventsParamsAdminApplianceServiceTagNAS appliance service tagro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.55 |
fluidFSEventsParamsAdminEscalationPeriodInMinutesEscalation Expiration Period (Minutes)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.56 |
fluidFSEventsParamsAdminObjectNameName of the configuration objectro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.57 |
fluidFSEventsParamsAdminRecommendedMaxCountrecommended maximum amount of the configuration objectro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.58 |
fluidFSEventsParamsAdminFSIDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.1.59 |
fluidFSEventsParamsAdminTenantNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.60 |
fluidFSEventsParamsAdminVolumeNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.1.61 |
fluidFSEventsParamsHardware OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.2 |
fluidFSEventsParamsHardwareNodeNameController namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.1 |
fluidFSEventsParamsHardwareNetworkIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.2 |
fluidFSEventsParamsHardwarePrefixro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.3 |
fluidFSEventsParamsHardwareCpuNameCPU name in the controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.4 |
fluidFSEventsParamsHardwareCpuTemperatureCPU tempraturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.5 |
fluidFSEventsParamsHardwareVlanTagro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.6 |
fluidFSEventsParamsHardwareDestinationNetworkro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.7 |
fluidFSEventsParamsHardwareCpuSpeedCPU speedro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.8 |
fluidFSEventsParamsHardwareAverageSpeedAverage CPU speedro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.9 |
fluidFSEventsParamsHardwareNodeIdController idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.10 |
fluidFSEventsParamsHardwareNetworkNameNetwork namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.11 |
fluidFSEventsParamsHardwarePacketLossPacket loss percentagero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.12 |
fluidFSEventsParamsHardwareEthNameEth namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.13 |
fluidFSEventsParamsHardwareLunIdLUN SCSI IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.14 |
fluidFSEventsParamsHardwareFromNodero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.15 |
fluidFSEventsParamsHardwareToNodero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.16 |
fluidFSEventsParamsHardwareFromEthro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.17 |
fluidFSEventsParamsHardwareToEthro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.18 |
fluidFSEventsParamsHardwareTapeNameTape device namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.19 |
fluidFSEventsParamsHardwareBatteryPercentageBPS battery percentagero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.20 |
fluidFSEventsParamsHardwareBatteryRemainTimeBPS battery remaining timero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.21 |
fluidFSEventsParamsHardwareSubnetNameSubnet namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.22 |
fluidFSEventsParamsHardwareHostNameHost namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.23 |
fluidFSEventsParamsHardwareBatteryLastReplaceBattery Last Replacero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.24 |
fluidFSEventsParamsHardwareDeviceTypeNameDevice Type Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.25 |
fluidFSEventsParamsHardwareDeviceNameDevice Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.26 |
fluidFSEventsParamsHardwareTemperatureTemperaturero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.27 |
fluidFSEventsParamsHardwareMeltingDistanceMelting Distancero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.28 |
fluidFSEventsParamsHardwareDeviceStateDevice Statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.29 |
fluidFSEventsParamsHardwareFirstNodeIdFirst Controller IDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.30 |
fluidFSEventsParamsHardwareSecondNodeIdSecond Controller IDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.31 |
fluidFSEventsParamsHardwareBondNameBond Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.32 |
fluidFSEventsParamsHardwareBandwidthBandwidthro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.33 |
fluidFSEventsParamsHardwareDiskNameLocal disk namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.34 |
fluidFSEventsParamsHardwareMemoryFirstNodeMemory on first controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.35 |
fluidFSEventsParamsHardwareMemorySecondNodeMemory on second controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.36 |
fluidFSEventsParamsHardwareActualMtuActual MTUro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.37 |
fluidFSEventsParamsHardwareOptimalMtuOptimal Mturo INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.38 |
fluidFSEventsParamsHardwareBpsLogInfoBps Log Inforo DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.39 |
fluidFSEventsParamsHardwareBpsAlarmBPS Alarm messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.40 |
fluidFSEventsParamsHardwarePowerSuppliesRedundancyStatuspower supplies redundancy statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.41 |
fluidFSEventsParamsHardwarePowerSuppliesElementStatuspower supplies element statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.42 |
fluidFSEventsParamsHardwarePowerSuppliesElementLocationpower supplies element locationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.43 |
fluidFSEventsParamsHardwarePowerSuppliesElementsCountThe number of power supplies elementsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.44 |
fluidFSEventsParamsHardwareChassisIDAppliance chassis IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.45 |
fluidFSEventsParamsHardwareTemperatureSensorNameTemperature sensor namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.46 |
fluidFSEventsParamsHardwareTemperatureSensorStatusTemperature sensor statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.47 |
fluidFSEventsParamsHardwareTemperatureSensorValueTemperature sensor valuero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.48 |
fluidFSEventsParamsHardwareTemperatureSensorErrorThresholdTemperature sensor error thresholdro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.49 |
fluidFSEventsParamsHardwareTemperatureSensorWarningThresholdTemperature sensor warning thresholdro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.50 |
fluidFSEventsParamsHardwarePowerSupplyNamePower supply namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.51 |
fluidFSEventsParamsHardwarePowerSupplyStatusPower supply statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.52 |
fluidFSEventsParamsHardwareBpsNameBPS namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.53 |
fluidFSEventsParamsHardwareBpsStatusBPS statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.54 |
fluidFSEventsParamsHardwareBpsBatteryRuntimeBPS battery runtimero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.55 |
fluidFSEventsParamsHardwareBpsBatteryChargeBPS battery chargero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.56 |
fluidFSEventsParamsHardwareComponentIndexComponent index in group of componentsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.57 |
fluidFSEventsParamsHardwareChassisIddeprecated - a duplication of above parameter chassisIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.58 |
fluidFSEventsParamsHardwareApplianceServiceTagAppliance service tagro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.59 |
fluidFSEventsParamsHardwareApplianceIdAppliance indexro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.60 |
fluidFSEventsParamsHardwareFcHbaNameFibre channel HBA port namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.61 |
fluidFSEventsParamsHardwareComponentNameComponent name in group of componentsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.62 |
fluidFSEventsParamsHardwareContextBasedServiceTagContrller or appliance service tagro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.63 |
fluidFSEventsParamsHardwareTargetEthNameTarget eth name in mesh connectivity monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.64 |
fluidFSEventsParamsHardwareIpMonitored external server ipro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.65 |
fluidFSEventsParamsHardwareExtSrvTypeMonitored external server ipro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.66 |
fluidFSEventsParamsHardwareDiskModelLocal disk model namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.67 |
fluidFSEventsParamsHardwareDiskSerialLocal disk serial numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.68 |
fluidFSEventsParamsHardwareDiskOverallReadsDisk overall reads in MBro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.69 |
fluidFSEventsParamsHardwareDiskOverallWritesDisk overall writes in MBro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.70 |
fluidFSEventsParamsHardwareBadSectorsCountHDD bad sectors countro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.71 |
fluidFSEventsParamsHardwareFailedWritesCountSSD failed writes countro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.72 |
fluidFSEventsParamsHardwareSupportedModelsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.73 |
fluidFSEventsParamsHardwareIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.74 |
fluidFSEventsParamsHardwarePciSlotSlot numberro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.2.75 |
fluidFSEventsParamsHardwarePciCardFull description of a PCI cardro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.2.76 |
fluidFSEventsParamsNdmp OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.3 |
fluidFSEventsParamsNdmpSessionIdNDMP job session idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.3.1 |
fluidFSEventsParamsNdmpJobTypeNDMP job type (backup/restore)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.2 |
fluidFSEventsParamsNdmpPathTarget pathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.3 |
fluidFSEventsParamsNdmpStartTimestampNDMP session start timestampro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.4 |
fluidFSEventsParamsNdmpInitiatorDMAServerDMA server that initiated the sessionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.5 |
fluidFSEventsParamsNdmpExecutedOnNodeNode that executes the jobro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.3.6 |
fluidFSEventsParamsNdmpNDMPMessageEvent message sent from NDMPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.7 |
fluidFSEventsParamsNdmpDetailEvent message sent from NDMPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.3.8 |
fluidFSEventsParamsQuota OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.4 |
fluidFSEventsParamsQuotaUserNameUser namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.2 |
fluidFSEventsParamsQuotaGroupNameGroup namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.3 |
fluidFSEventsParamsQuotaVolumeSizeVolume sizero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.4 |
fluidFSEventsParamsQuotaVolumeSpaceThresholdVolume space thresholdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.5 |
fluidFSEventsParamsQuotaSnapshotsSpaceThresholdSnapshots space thresholdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.6 |
fluidFSEventsParamsQuotaQuotaThresholdQuota threshold for user or groupro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.7 |
fluidFSEventsParamsQuotaVolumeFreeSpaceVolume free spacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.8 |
fluidFSEventsParamsQuotaSystemCapacityCapacity of the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.9 |
fluidFSEventsParamsQuotaSystemThresholdSystem thresholdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.10 |
fluidFSEventsParamsQuotaQuotaDirPathThe path of the Directory Quotaro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.11 |
fluidFSEventsParamsQuotaVirtualVolumeNAS volume FSIDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.4.12 |
fluidFSEventsParamsQuotaVirtualVolumeNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.13 |
fluidFSEventsParamsQuotaUserNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.14 |
fluidFSEventsParamsQuotaGroupNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.4.15 |
fluidFSEventsParamsReplication OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.5 |
fluidFSEventsParamsReplicationSourceClusterSource clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.2 |
fluidFSEventsParamsReplicationDestinationClusterDestination clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.4 |
fluidFSEventsParamsReplicationErrorCodeError codero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.5.5 |
fluidFSEventsParamsReplicationTaskNameTask name of file level replicationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.6 |
fluidFSEventsParamsReplicationErrorDescError descriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.7 |
fluidFSEventsParamsReplicationOldMngConVipOld manage console VIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.8 |
fluidFSEventsParamsReplicationNewMngConVipNew manage console VIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.9 |
fluidFSEventsParamsReplicationStartTimereplication start timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.10 |
fluidFSEventsParamsReplicationEndTimereplication end timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.11 |
fluidFSEventsParamsReplicationTotalTransferredSizetotal transferred sizero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.12 |
fluidFSEventsParamsReplicationRehydratedVolumeSizerehydrated volume sizero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.13 |
fluidFSEventsParamsReplicationSourceVolumeSource NAS volume FSIDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.5.14 |
fluidFSEventsParamsReplicationDestinationVolumeDestination NAS volumero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.5.15 |
fluidFSEventsParamsReplicationDomainIddomain Idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.16 |
fluidFSEventsParamsReplicationSnapshotIdsnapshot Idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.17 |
fluidFSEventsParamsReplicationDomainReplicationStatsdomain replication statsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.18 |
fluidFSEventsParamsReplicationSavingsPercentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.19 |
fluidFSEventsParamsReplicationSourceVolumeNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.20 |
fluidFSEventsParamsReplicationDestinationVolumeNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.5.21 |
fluidFSEventsParamsSnapshot OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.7 |
fluidFSEventsParamsSnapshotSnapshotNameSnapshot namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.1 |
fluidFSEventsParamsSnapshotVolumeNameVolume namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.2 |
fluidFSEventsParamsSnapshotFSIDNAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.7.3 |
fluidFSEventsParamsSnapshotOutputFileNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.4 |
fluidFSEventsParamsSnapshotOutputFSIDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.7.5 |
fluidFSEventsParamsSnapshotOutputPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.6 |
fluidFSEventsParamsSnapshotFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.7 |
fluidFSEventsParamsSnapshotOutputFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.7.8 |
fluidFSEventsParamsHealth OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.9 |
fluidFSEventsParamsHealthPercentOfUsedSpacePercentage of system used spacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.1 |
fluidFSEventsParamsHealthNodeNameNode namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.2 |
fluidFSEventsParamsHealthServiceService namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.3 |
fluidFSEventsParamsHealthPartitionNameLocal partition namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.4 |
fluidFSEventsParamsHealthPercentOfUsedSwapPercent of used swap memoryro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.5 |
fluidFSEventsParamsHealthNodeIdsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.6 |
fluidFSEventsParamsHealthPercentOfUsedFileDescriptorsPercent of used file descriptorsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.7 |
fluidFSEventsParamsHealthThisNodeIdNode id of the current nodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.8 |
fluidFSEventsParamsHealthPeerNodeIdNode id of the peer nodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.9 |
fluidFSEventsParamsHealthVirtualVolumeNAS volume namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.10 |
fluidFSEventsParamsHealthFSIDNAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.11 |
fluidFSEventsParamsHealthMinFreeSpaceInBytesFree space in bytesro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.12 |
fluidFSEventsParamsHealthModuleNameThe BMR module namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.13 |
fluidFSEventsParamsHealthNumberOfClientsNumber of clientsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.14 |
fluidFSEventsParamsHealthDomainIdId of the domain from which the event was raisedro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.15 |
fluidFSEventsParamsHealthServiceNameThe name of the servicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.16 |
fluidFSEventsParamsHealthSynchronizedServiceNameThe name of the service being synchronizedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.17 |
fluidFSEventsParamsHealthTimeoutThe timeout in minutesro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.18 |
fluidFSEventsParamsHealthStorageIdInternal id of a storagero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.19 |
fluidFSEventsParamsHealthSynchronizedStorageIdInternal id of a storage being synchronizedro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.20 |
fluidFSEventsParamsHealthNodeIdId of a nodero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.21 |
fluidFSEventsParamsHealthSetIdId of a LUNs' setro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.22 |
fluidFSEventsParamsHealthLunIdId of a LUNro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.23 |
fluidFSEventsParamsHealthHealthyNodeIdHealthy NAS controller idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.24 |
fluidFSEventsParamsHealthFaultyNodeIdFaulty NAS controller idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.25 |
fluidFSEventsParamsHealthFmsAdminCmdFMS Admin commandro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.26 |
fluidFSEventsParamsHealthQuorumIPFMS Quorum IPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.27 |
fluidFSEventsParamsHealthFmsStateFMS NAS controller Statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.28 |
fluidFSEventsParamsHealthFsdInstanceFS Daemon instance in the nodero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.29 |
fluidFSEventsParamsHealthErrorDescriptionDescription of the errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.30 |
fluidFSEventsParamsHealthBacktraceDebug backtrace informationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.31 |
fluidFSEventsParamsHealthDsidDSID (internal filesystem ID) of file or directory. Use dsid2name utility to translate dsid to path via command line, also dsid2path translator is designed to do it automatically for eventsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.32 |
fluidFSEventsParamsHealthFileMappingFS mapping from file range to disk range (hex offsets)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.33 |
fluidFSEventsParamsHealthParentDirDsidParent directory file idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.34 |
fluidFSEventsParamsHealthDirEntryDirectory entry pointing to a filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.35 |
fluidFSEventsParamsHealthPacketLossThresholdPercentPercents threashold for interconnect packet lossro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.36 |
fluidFSEventsParamsHealthFsLogicalErrorDescriptionInternal description of logical error found in the FS layoutro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.37 |
fluidFSEventsParamsHealthLowCacheThresholdPercentPercents threashold for low on cachero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.38 |
fluidFSEventsParamsHealthProtocolProtocolro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.39 |
fluidFSEventsParamsHealthConnectionsVectorConnections per nodesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.40 |
fluidFSEventsParamsHealthAdClockSkewSkew between NAS controller and AD clocksro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.41 |
fluidFSEventsParamsHealthMaxAdClockSkewCritical skew between NAS controller and AD clocksro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.42 |
fluidFSEventsParamsHealthServerKindServer kindro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.43 |
fluidFSEventsParamsHealthResponseTimeResponse timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.44 |
fluidFSEventsParamsHealthCriticalResponseTimeCritical response timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.45 |
fluidFSEventsParamsHealthInternalInfoInternal failure info for RnD troubleshooting, for example slow request detailsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.46 |
fluidFSEventsParamsHealthServerIpsList of server IPsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.47 |
fluidFSEventsParamsHealthOldQuorumIPFMS old Quorum IPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.48 |
fluidFSEventsParamsHealthDedupSpaceMarginMbFree space needed for optimization of a volume, in Megabytesro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.49 |
fluidFSEventsParamsHealthOldNumberOfVirtualDomainsOld number of Virtual Domainsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.50 |
fluidFSEventsParamsHealthNewNumberOfVirtualDomainsNew number of Virtual Domainsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.51 |
fluidFSEventsParamsHealthNumberOfDomainsInPreviousDistributionNumber of virtual domains in the file's previous distributionro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.52 |
fluidFSEventsParamsHealthNumberOfDomainsInNewDistributionNumber of virtual domains in the file's new distributionro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.53 |
fluidFSEventsParamsHealthVirtualDomainThe number of the virtual domainro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.54 |
fluidFSEventsParamsHealthCurrentPhysicalDomainThe number of the physical domain that is currently holds the virtual domainro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.55 |
fluidFSEventsParamsHealthNewPhysicalDomainThe number of the physical domain that will hold the virtual domain after the hot migration process endsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.56 |
fluidFSEventsParamsHealthIpAddrIP Addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.57 |
fluidFSEventsParamsHealthMacAddrmac addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.58 |
fluidFSEventsParamsHealthLunsListA list of LUNs, comma separatedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.59 |
fluidFSEventsParamsHealthTenantIdTenant unique identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.60 |
fluidFSEventsParamsHealthServerNamesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.61 |
fluidFSEventsParamsHealthDomainNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.62 |
fluidFSEventsParamsHealthServerListro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.63 |
fluidFSEventsParamsHealthDomainControllerNameActive Directory domain namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.64 |
fluidFSEventsParamsHealthFsidro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.65 |
fluidFSEventsParamsHealthTimeDiffSecro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.9.66 |
fluidFSEventsParamsHealthFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.67 |
fluidFSEventsParamsHealthParentDirDsidPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.68 |
fluidFSEventsParamsHealthTenantNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.69 |
fluidFSEventsParamsHealthDsidPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.9.70 |
fluidFSEventsParamsAntivirus OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.10 |
fluidFSEventsParamsAntivirusShareNamecifs share where scanning occursro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.1 |
fluidFSEventsParamsAntivirusVirusDescriptionbrief virus descriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.2 |
fluidFSEventsParamsAntivirusFilePathpath of the scanned filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.3 |
fluidFSEventsParamsAntivirusQuarantinedPathpath of the quarantined filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.4 |
fluidFSEventsParamsAntivirusInfectedActionaction applied to infected filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.5 |
fluidFSEventsParamsAntivirusAdsNamename of the ADSro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.6 |
fluidFSEventsParamsAntivirusSnapNamename of the snapshot for previous versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.7 |
fluidFSEventsParamsAntivirusHostantivirus host hostname or IP addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.8 |
fluidFSEventsParamsAntivirusScanningFacilityactual antivirus host and port used for scanningro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.10 |
fluidFSEventsParamsAntivirusScanningDurationscanning duration, real number in seconds with enough precisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.11 |
fluidFSEventsParamsAntivirusScanningDurationThresholdcritical scanning duration in seconds used as the threshold for eventro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.10.12 |
fluidFSEventsParamsAntivirusDsidDSID (internal filesystem ID) of file or directory. Use dsid2name utility to translate dsid to path via command line, also dsid2path translator is designed to do it automatically for eventsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.13 |
fluidFSEventsParamsAntivirusFSIDNAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.10.14 |
fluidFSEventsParamsAntivirusAccessDeniedReasonExtended details about reason of returned ACCESS_DENIED errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.15 |
fluidFSEventsParamsAntivirusFileSizeMbSize (in Megabytes) of the file to be scanned for virusesro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.10.16 |
fluidFSEventsParamsAntivirusLargeFileSizeLimitMbLimit of the file size (in Megabytes) of the file to be scanned for viruses. Larger files are not scanned.ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.10.17 |
fluidFSEventsParamsAntivirusIcapStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.18 |
fluidFSEventsParamsAntivirusServerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.19 |
fluidFSEventsParamsAntivirusPortantivirus host portro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.20 |
fluidFSEventsParamsAntivirusFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.21 |
fluidFSEventsParamsAntivirusDsidPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.10.22 |
fluidFSEventsParamsClientAccess OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.11 |
fluidFSEventsParamsClientAccessMaxConnectionsmaximal number of connectionsro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.1 |
fluidFSEventsParamsClientAccessNfsExportNFS export name, as defined on clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.2 |
fluidFSEventsParamsClientAccessMountPathNFS mount path as specified by user for mount commandro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.3 |
fluidFSEventsParamsClientAccessNfsClientPortNFS client port numberro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.4 |
fluidFSEventsParamsClientAccessNfsExportOptionsNFS export options, as defined on clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.5 |
fluidFSEventsParamsClientAccessClientIpAddrClient IP addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.6 |
fluidFSEventsParamsClientAccessNfsUserUser ID as seen from NFS server, either UID or SID. Will be translated to username by 'uidOrSid2name' translator automaticallyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.7 |
fluidFSEventsParamsClientAccessCifsUserUser ID as seen from Samba - TUID. Will be translated to username by 'tuid2name' translator automaticallyro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.8 |
fluidFSEventsParamsClientAccessUserNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.9 |
fluidFSEventsParamsClientAccessCifsShareSMB share name, as defined on clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.10 |
fluidFSEventsParamsClientAccessDsidDSID (internal filesystem ID) of file or directory. Use dsid2name utility to translate dsid to path.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.11 |
fluidFSEventsParamsClientAccessNfsOpNFS operation (NFS verb, command, etc)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.12 |
fluidFSEventsParamsClientAccessVolumeStyleVolume style - NTFS, UNIX or MIXEDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.13 |
fluidFSEventsParamsClientAccessUserOwnerUser owner for a filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.14 |
fluidFSEventsParamsClientAccessGroupOwnerGroup owner for a filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.15 |
fluidFSEventsParamsClientAccessUserIdentityTypeUser type (NTFS or UNIX, i.e. UID or SID)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.16 |
fluidFSEventsParamsClientAccessGroupIdentityType6roup type (NTFS or UNIX, i.e. GID or GSID)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.17 |
fluidFSEventsParamsClientAccessDesiredNfsAccessMask7esired access maskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.18 |
fluidFSEventsParamsClientAccessGrantedNfsAccessMaskGranted (maximal) access maskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.19 |
fluidFSEventsParamsClientAccessDesiredCifsAccessMaskDesired access maskro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.20 |
fluidFSEventsParamsClientAccessGrantedCifsAccessMaskGranted (maximal) access maskro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.21 |
fluidFSEventsParamsClientAccessMissedCifsAccessBitsMissed access bits (mask)ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.22 |
fluidFSEventsParamsClientAccessCifsOpSMB operation (SMB verb, VFS verb, generic command, etc)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.23 |
fluidFSEventsParamsClientAccessCifsPrivilegesSMB User privilegesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.24 |
fluidFSEventsParamsClientAccessCifsGuestAccountSMB guest account as configured on the clusterro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.25 |
fluidFSEventsParamsClientAccessNasContainerIdNAS Volume (volume name)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.26 |
fluidFSEventsParamsClientAccessNasContainerPathPath related to specified NAS Volumero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.27 |
fluidFSEventsParamsClientAccessNasControllerIdNAS controller ID (node ID)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.28 |
fluidFSEventsParamsClientAccessNasContainerIdIntegerNAS Volume ID (volume ID, i.e. FSID uint32 value). Will be translated to volume name by translatorro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.29 |
fluidFSEventsParamsClientAccessLockingUserUser identity who holds the lock on requested file and causing access conflictro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.30 |
fluidFSEventsParamsClientAccessInternalInfoInternal failure info for RnD troubleshooting, for example access decision flow or client disconnection reasonro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.31 |
fluidFSEventsParamsClientAccessNfsErrorCodeNFSERR_x code for troubleshooting purpose (as the part of internal info)ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.32 |
fluidFSEventsParamsClientAccessOpenModeAccessBitsOpen mode access bits(mask) used during file openro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.33 |
fluidFSEventsParamsClientAccessShareLevelPermissionsModeShare-level permission mode applied for current connection, like NONE, READ, CHANGE or FULL-CONTROLro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.34 |
fluidFSEventsParamsClientAccessOperationoperation being executedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.35 |
fluidFSEventsParamsClientAccessUserUser ID (will undergo transformation as required)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.36 |
fluidFSEventsParamsClientAccessCifsUser2User SID as seen by likewise/cifs_serverro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.37 |
fluidFSEventsParamsClientAccessNetgroupNameUNIX external repository netgroup namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.38 |
fluidFSEventsParamsClientAccessParentNetgroupNameUNIX external repository netgroup namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.39 |
fluidFSEventsParamsClientAccessNetgroupThresholdCritical threshold of netgroup metric (like size or nesting level)ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.40 |
fluidFSEventsParamsClientAccessNodeIdNode Id (NAS controller ID)ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.41 |
fluidFSEventsParamsClientAccessMaxOpenFilesPerNodemaximal number of open files per nodero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.42 |
fluidFSEventsParamsClientAccessAdProviderNameName of active directory providerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.43 |
fluidFSEventsParamsClientAccessDomainNameDomain namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.44 |
fluidFSEventsParamsClientAccessFileExtensionFile extensionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.45 |
fluidFSEventsParamsClientAccessCifsErrorCodeCifs code for troubleshooting purpose (as the part of internal info)ro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.46 |
fluidFSEventsParamsClientAccessClusterVIPServer VIP addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.47 |
fluidFSEventsParamsClientAccessServerKindServer kindro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.48 |
fluidFSEventsParamsClientAccessServiceService namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.49 |
fluidFSEventsParamsClientAccessUserEmailro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.50 |
fluidFSEventsParamsClientAccessDroppedNotificationsCountercounts how many events were droppedro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.51 |
fluidFSEventsParamsClientAccessPolicyNamePolicy namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.52 |
fluidFSEventsParamsClientAccessPolicyGuidPolicy guidro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.53 |
fluidFSEventsParamsClientAccessPolicyTargetPathPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.54 |
fluidFSEventsParamsClientAccessTenantIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.55 |
fluidFSEventsParamsClientAccessTlsVersionVersion of TLS protocolro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.11.56 |
fluidFSEventsParamsClientAccessBaseLandingPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.57 |
fluidFSEventsParamsClientAccessSuffixLandingPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.58 |
fluidFSEventsParamsClientAccessFilePathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.59 |
fluidFSEventsParamsClientAccessSearchedObjectsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.60 |
fluidFSEventsParamsClientAccessRuleDNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.61 |
fluidFSEventsParamsClientAccessPolicyDNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.62 |
fluidFSEventsParamsClientAccessNasContainerIdIntegerNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.63 |
fluidFSEventsParamsClientAccessTenantNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.64 |
fluidFSEventsParamsClientAccessNfsUserNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.65 |
fluidFSEventsParamsClientAccessDsidPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.66 |
fluidFSEventsParamsClientAccessDesiredNfsAccessMaskHrfro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.67 |
fluidFSEventsParamsClientAccessGrantedNfsAccessMaskHrfro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.68 |
fluidFSEventsParamsClientAccessUserOwnerNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.69 |
fluidFSEventsParamsClientAccessGroupOwnerNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.70 |
fluidFSEventsParamsClientAccessDesiredCifsAccessMaskNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.71 |
fluidFSEventsParamsClientAccessMissedCifsAccessBitsNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.72 |
fluidFSEventsParamsClientAccessOpenModeAccessBitsNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.73 |
fluidFSEventsParamsClientAccessCifsUser2Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.11.74 |
fluidFSEventsParamsLicensing OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.13 |
fluidFSEventsParamsLicensingFileNameName of the license xml filero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.13.1 |
fluidFSEventsParamsLicensingInstalledFeaturesList of the features which were installed, seperated by commasro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.13.2 |
fluidFSEventsParamsLicensingNumOfDaysNumber of days till expiration of featurero INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.13.3 |
fluidFSEventsParamsLicensingFluidFsVersionFluidFS software versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.13.4 |
fluidFSEventsParamsExaminer OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.14 |
fluidFSEventsParamsExaminerCategoryCorruption categoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.14.1 |
fluidFSEventsParamsExaminerLevelLevel of the errorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.14.2 |
fluidFSEventsParamsComponent OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.15 |
fluidFSEventsParamsComponentUserNameUser namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.1 |
fluidFSEventsParamsComponentObjectIdobjectIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.2 |
fluidFSEventsParamsComponentTimezonetimezonero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.3 |
fluidFSEventsParamsComponentNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.4 |
fluidFSEventsParamsComponentRetcodeStringRetCode stringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.5 |
fluidFSEventsParamsComponentRemoteVolumeRemote Volumero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.6 |
fluidFSEventsParamsComponentSystemServiceStateSystem Service Modero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.7 |
fluidFSEventsParamsComponentAdministratorSystem administratorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.8 |
fluidFSEventsParamsComponentSnapshotIDSnapshot idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.10 |
fluidFSEventsParamsComponentNdmpLockNdmpLockro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.11 |
fluidFSEventsParamsComponentExpiryExpiryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.12 |
fluidFSEventsParamsComponentShareNameName of the SMB sharero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.13 |
fluidFSEventsParamsComponentNFSExportPathPath that is exported by NFS filesystemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.14 |
fluidFSEventsParamsComponentDomainDomainro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.15 |
fluidFSEventsParamsComponentUserInterfaceTypeUser interface typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.16 |
fluidFSEventsParamsComponentUserInterfaceClientUser interface clientro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.17 |
fluidFSEventsParamsComponentRemoteSystemNameSystem (cluster) namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.18 |
fluidFSEventsParamsComponentApplianceServiceTagNAS appliance service tagro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.19 |
fluidFSEventsParamsComponentServicePackFileNameService pack file namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.20 |
fluidFSEventsParamsComponentNetworkIdNetwork IP addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.21 |
fluidFSEventsParamsComponentNetmaskNetwork netmaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.22 |
fluidFSEventsParamsComponentSubnetAccessSubnet Access typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.23 |
fluidFSEventsParamsComponentRouteNameRoute Rules unique namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.24 |
fluidFSEventsParamsComponentRouteGatewayRoute Rules Gateway IPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.25 |
fluidFSEventsParamsComponentClientNetworkInterfaceMtuMTUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.26 |
fluidFSEventsParamsComponentClientNetworkInterfaceBondModeBonding modero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.27 |
fluidFSEventsParamsComponentLocalAccountNameLocal user/group namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.28 |
fluidFSEventsParamsComponentUserDatabaseTypeType of external UNIX accounts repository: NIS, LDAP or None.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.29 |
fluidFSEventsParamsComponentWindowsUserUser name from Windows repositoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.30 |
fluidFSEventsParamsComponentUnixUserUser name from UNIX repositoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.31 |
fluidFSEventsParamsComponentBlink1Blink first controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.32 |
fluidFSEventsParamsComponentBlink2Blink second controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.33 |
fluidFSEventsParamsComponentControllerIdThe controller IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.34 |
fluidFSEventsParamsComponentClientIpClient Ipro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.35 |
fluidFSEventsParamsComponentAccessIpAccess Ipro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.36 |
fluidFSEventsParamsComponentNodeIdNode Idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.37 |
fluidFSEventsParamsComponentNetworkInterfaceNetwork Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.38 |
fluidFSEventsParamsComponentPinStatePin or Unpin client to specific controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.39 |
fluidFSEventsParamsComponentApplianceIdAppliance Idro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.40 |
fluidFSEventsParamsComponentClusterNameCluster Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.41 |
fluidFSEventsParamsComponentLicensedFeatureLicensed Featurero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.42 |
fluidFSEventsParamsComponentFabricNameFabric Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.43 |
fluidFSEventsParamsComponentSourceFilePathSource File Pathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.44 |
fluidFSEventsParamsComponentDestinationDirDestination Directoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.45 |
fluidFSEventsParamsComponentDestinationFileNameDestination File Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.46 |
fluidFSEventsParamsComponentDestinationParentDirDestination Parent Directoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.47 |
fluidFSEventsParamsComponentNDMPSessionIdNDMP Session IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.48 |
fluidFSEventsParamsComponentClientComputerNameClient Computer Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.49 |
fluidFSEventsParamsComponentClientUserNameClient User Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.50 |
fluidFSEventsParamsComponentPartnerIpPartner IPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.51 |
fluidFSEventsParamsComponentVirtualVolumeFolderNameVirtual Volume Folder Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.52 |
fluidFSEventsParamsComponentPrefixNetwork prefixro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.53 |
fluidFSEventsParamsComponentRunCifsFileAccessibilityDiagnosticShareNameRunCifsFileAccessibilityDiagnosticShareNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.54 |
fluidFSEventsParamsComponentRunCifsFileAccessibilityDiagnosticClientIPRunCifsFileAccessibilityDiagnosticClientIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.55 |
fluidFSEventsParamsComponentRunCifsFileAccessibilityDiagnosticPathRunCifsFileAccessibilityDiagnosticPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.56 |
fluidFSEventsParamsComponentRunClientConnectivityDiagnosticClientIPRunClientConnectivityDiagnosticClientIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.57 |
fluidFSEventsParamsComponentRunClientConnectivityDiagnosticProtocolRunClientConnectivityDiagnosticProtocolro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.58 |
fluidFSEventsParamsComponentRunNetworkDiagnosticClientIPRunNetworkDiagnosticClientIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.59 |
fluidFSEventsParamsComponentRunNfsFileAccessibilityDiagnosticExportPathRunNfsFileAccessibilityDiagnosticExportPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.60 |
fluidFSEventsParamsComponentRunNfsFileAccessibilityDiagnosticFSIDRunNfsFileAccessibilityDiagnosticFSIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.61 |
fluidFSEventsParamsComponentRunNfsFileAccessibilityDiagnosticClientIPRunNfsFileAccessibilityDiagnosticClientIPro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.62 |
fluidFSEventsParamsComponentRunNfsFileAccessibilityDiagnosticPathRunNfsFileAccessibilityDiagnosticPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.63 |
fluidFSEventsParamsComponentRunPerformanceDiagnosticFSIDRunPerformanceDiagnosticFSIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.64 |
fluidFSEventsParamsComponentFilePathFile pathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.65 |
fluidFSEventsParamsComponentDestinationFilePathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.68 |
fluidFSEventsParamsComponentClientProtocolNFS/SMB protocolro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.69 |
fluidFSEventsParamsComponentClientProtocolDetailsSession or opened file detailsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.70 |
fluidFSEventsParamsComponentSourceVMNameSource VM Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.71 |
fluidFSEventsParamsComponentVmWareServerNameVMWare Server Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.72 |
fluidFSEventsParamsComponentNumberOfClonesNumber Of Clonesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.73 |
fluidFSEventsParamsComponentServicePackVersionVersion of a service packro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.74 |
fluidFSEventsParamsComponentDestinationNetworkIDRoute Rules route ip addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.75 |
fluidFSEventsParamsComponentDestinationPrefixRoute Rules route ip prefixro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.76 |
fluidFSEventsParamsComponentFolderPathFolder pathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.77 |
fluidFSEventsParamsComponentDSIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.78 |
fluidFSEventsParamsComponentTapeDeviceNameConfigured name of tape devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.79 |
fluidFSEventsParamsComponentEventsSpacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.80 |
fluidFSEventsParamsComponentGpoTimeoutro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.81 |
fluidFSEventsParamsComponentTenantIdTenant unique identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.82 |
fluidFSEventsParamsComponentFSIDNAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.15.83 |
fluidFSEventsParamsComponentUIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.84 |
fluidFSEventsParamsComponentRemoteClusterIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.85 |
fluidFSEventsParamsComponentRemoteFSIDro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.15.86 |
fluidFSEventsParamsComponentStorageIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.87 |
fluidFSEventsParamsComponentSourceFSIDSource NAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.15.88 |
fluidFSEventsParamsComponentDestinationFSIDDestination NAS volume idro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.15.89 |
fluidFSEventsParamsComponentStatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.90 |
fluidFSEventsParamsComponentFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.91 |
fluidFSEventsParamsComponentTenantNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.92 |
fluidFSEventsParamsComponentAdminNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.93 |
fluidFSEventsParamsComponentRemoteClusterNameName of the partner systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.94 |
fluidFSEventsParamsComponentRemoteVolumeNameName of the remote NAS volumero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.95 |
fluidFSEventsParamsComponentWindowsUserNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.96 |
fluidFSEventsParamsComponentUnixUserNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.97 |
fluidFSEventsParamsComponentSourceFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.98 |
fluidFSEventsParamsComponentDestinationFSIDNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.99 |
fluidFSEventsParamsComponentDSIDPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.15.100 |
fluidFSEventsParamsSupportShell OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.16 |
fluidFSEventsParamsSupportShellNodeNode namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.16.1 |
fluidFSEventsParamsSupportShellCommandCommand executed in support shellro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.16.2 |
fluidFSEventsParamsSupportShellUserNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.16.3 |
fluidFSEventsParamsAuditing OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.17 |
fluidFSEventsParamsAuditingUUser ID as seen from Samba - TUID. Will be translated to username by 'tuid2name' translator automaticallyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.1 |
fluidFSEventsParamsAuditingDDSID (internal filesystem ID) of file or directory. Use dsid2name utility to translate dsid to path.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.2 |
fluidFSEventsParamsAuditingNNAS Volume ID (volume ID, i.e. FSID uint32 value). Will be translated to volume name by translatorro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.17.3 |
fluidFSEventsParamsAuditingDesiredCifsAccessMaskDesired access maskro INTEGER .1.3.6.1.4.1.674.11000.2000.200.21.17.4 |
fluidFSEventsParamsAuditingNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.5 |
fluidFSEventsParamsAuditingUNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.6 |
fluidFSEventsParamsAuditingNNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.7 |
fluidFSEventsParamsAuditingDPathro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.8 |
fluidFSEventsParamsAuditingDesiredCifsAccessMaskNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.17.9 |
fluidFSEventsParamsUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.21.18 |
fluidFSEventsParamsUpgradeServicePackNameFile name of the Service Packro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.21.18.1 |
fluidFSEventsGeneralParams OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.22 |
sysNameGeneral system namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.200.22.1 |
fluidFSGeneralEvents OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.200.23 |
fluidFSCluOKThis trap will be sent any time the condition of the cluster
becomes ok. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.1 |
fluidFSCluDegradedThis trap will be sent any time the condition of the cluster
becomes degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.2 |
fluidFSCluFailedThis trap will be sent any time the condition of the cluster
becomes failed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.3 |
fluidFSCluNodeOKThis trap will be sent any time the condition of a node in
the cluster becomes ok. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.4 |
fluidFSCluNodeDegradedThis trap will be sent any time the condition of a node in
the cluster becomes degraded.
User Action: Make a note of the cluster node name then
check the node for the cause of the degraded condition. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.5 |
fluidFSCluNodeFailedThis trap will be sent any time the condition of a node in
the cluster becomes failed.
User Action: Make a note of the cluster node name
then check the node for the cause of the failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.6 |
fluidFSCluResourceOKThis trap will be sent any time the condition of a cluster
resource becomes ok. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.7 |
fluidFSCluResourceDegradedThis trap will be sent any time the condition of a cluster
resource becomes degraded.
User Action: Make a note of the cluster resource name then
check the resource for the cause of the degraded condition. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.8 |
fluidFSCluResourceFailedThis trap will be sent any time the condition of a cluster
resource becomes failed.
User Action: Make a note of the cluster resource name
then check the resource for the cause of the failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.9 |
fluidFSGenNormalEventThis trap will be sent for normal events. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.14 |
fluidFSGenMinorEventThis trap will be sent for minor events. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.15 |
fluidFSGenMajorEventThis trap will be sent for major events. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.16 |
fluidFSGenCriticalEventThis trap will be sent for critical events. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.17 |
fluidFSAntiVirusEventThe antivirus software on or connected to system
detected a virus. NOTIFICATION-TYPE .1.3.6.1.4.1.674.11000.2000.200.23.18 |
fluidFSMIBIdentityFluidFS MIB MODULE-IDENTITY .1.3.6.1.4.1.674.11000.2000.200.100 |