IDRAC-MIB-SMIv2
AI MIB Summary
The IDRAC-MIB-SMIv2 module enables SNMP-based out-of-band monitoring of Dell iDRAC hardware by exposing system telemetry metrics such as temperature, fan speed, power supply status, and memory utilization, while facilitating event notification through defined SNMP traps.
This MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports.
Main OID:
outOfBandGroup.1.3.6.1.4.1.674.10892.5
779
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
779 total| Object Name |
|---|
outOfBandGroupThis MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports. MODULE-IDENTITY .1.3.6.1.4.1.674.10892.5 |
informationGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.1 |
racInfoGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.1.1 |
racNameThis attribute defines the product name of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.1 |
racShortNameThis attribute defines the short product name of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.2 |
racDescriptionThis attribute defines the product description of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.3 |
racManufacturerThis attribute defines the product manufacturer of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.4 |
racVersionThis attribute defines the product version of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.5 |
racURLThis attribute defines the out-of-band UI URL of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.6 |
racTypeThis attribute defines the type of a remote access card.ro RacTypeEnum .1.3.6.1.4.1.674.10892.5.1.1.7 |
racFirmwareVersionThis attribute defines the firmware version of a remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.1.1.8 |
chassisInfoGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.1.2 |
chassisServiceTagThis attribute defines the service tag of the modular chassis. The value is zero length if not a modular system.ro StringType .1.3.6.1.4.1.674.10892.5.1.2.1 |
chassisNameModularThis attribute defines the chassis name of the modular chassis. The value is zero length if not a modular system.ro StringType .1.3.6.1.4.1.674.10892.5.1.2.2 |
chassisModelModularThis attribute defines the model of the modular chassis. The value is zero length if not a modular system.ro StringType .1.3.6.1.4.1.674.10892.5.1.2.3 |
systemInfoGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.1.3 |
systemFQDNThis attribute defines the fully qualified domain name of the system. For example, hostname.domainname.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.1 |
systemServiceTagThis attribute defines the service tag of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.2 |
systemExpressServiceCodeThis attribute defines the express service code of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.3 |
systemAssetTagThis attribute defines the asset tag of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.4 |
systemBladeSlotNumberThis attribute defines the slot number of the system in the modular chassis.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.5 |
systemOSNameThis attribute defines the name of the operating system that the host is running.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.6 |
systemFormFactorThis attribute defines the form factor of the system.ro SystemFormFactorEnum .1.3.6.1.4.1.674.10892.5.1.3.7 |
systemDataCenterNameThis attribute defines the Data Center locator of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.8 |
systemAisleNameThis attribute defines the Aisle locator of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.9 |
systemRackNameThis attribute defines the Rack locator of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.10 |
systemRackSlotThis attribute defines the Rack Slot locator of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.11 |
systemModelNameThis attribute defines the model name of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.12 |
systemSystemIDThis attribute defines the system ID of the system.ro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.1.3.13 |
systemOSVersionThis attribute defines the version of the operating system that the host is running.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.14 |
systemRoomNameThis attribute defines the Room locator of the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.15 |
systemChassisSystemHeightThis attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component. (If not applicable, a 'no such name' error is returned.)ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.1.3.16 |
systemBladeGeometryThis attribute defines the geometry for a modular system. (If not applicable, a 'no such name' error is returned.)ro BladeGeometryEnum .1.3.6.1.4.1.674.10892.5.1.3.17 |
systemNodeIDThis attribute defines the node ID of the system. The node ID provides a unique identifier for the system.ro StringType .1.3.6.1.4.1.674.10892.5.1.3.18 |
statusGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.2 |
globalSystemStatusThis attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.2.1 |
systemLCDStatusThis attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.2.2 |
globalStorageStatusThis attribute defines the overall storage status being monitored by the remote access card.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.2.3 |
systemPowerStateThis attribute defines the power state of the system.ro PowerStateStatusEnum .1.3.6.1.4.1.674.10892.5.2.4 |
systemPowerUpTimeThis attribute defines the power-up time of the system in seconds.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.2.5 |
alertGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3 |
alertVariablesGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.1 |
alertMessageIDMessage ID of the event.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.1 |
alertMessageMessage describing the alert.ro StringType .1.3.6.1.4.1.674.10892.5.3.1.2 |
alertCurrentStatusCurrent status of object causing the alert, if applicable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.3.1.3 |
alertSystemServiceTagService tag of the system.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.4 |
alertSystemFQDNFully qualified domain name of the system.ro StringType .1.3.6.1.4.1.674.10892.5.3.1.5 |
alertFQDDFully qualified device descriptor of the device.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.6 |
alertDeviceDisplayNameDisplay name of the device/FQDD.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.7 |
alertMessageArgumentsConcatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes.ro StringType .1.3.6.1.4.1.674.10892.5.3.1.8 |
alertChassisServiceTagFor modular systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length).ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.9 |
alertChassisNameFor modular systems, the chassis name of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length).ro OCTET STRING .1.3.6.1.4.1.674.10892.5.3.1.10 |
alertRacFQDNFully qualified domain name of the remote access card.ro StringType .1.3.6.1.4.1.674.10892.5.3.1.11 |
alertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2 |
systemAlertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2.1 |
alertNetworkFailureNetwork failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2089 |
alertNetworkWarningNetwork warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2090 |
alertNetworkInformationNetwork information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2091 |
alertFanFailureFan failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2153 |
alertFanWarningFan warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2154 |
alertFanInformationFan information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2155 |
alertTemperatureProbeFailureTemperature sensor has detected a failure value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2161 |
alertTemperatureProbeWarningTemperature sensor has detected a warning value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2162 |
alertTemperatureProbeNormalTemperature sensor value is within range. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2163 |
alertVoltageProbeFailureVoltage sensor has detected a failure value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2169 |
alertVoltageProbeWarningVoltage sensor has detected a warning value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2170 |
alertVoltageProbeNormalVoltage sensor reading is within range. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2171 |
alertAmperageProbeFailureCurrent sensor has detected a failure value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2177 |
alertAmperageProbeWarningCurrent sensor has detected a warning value. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2178 |
alertAmperageProbeNormalCurrent sensor reading is within range. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2179 |
alertPowerSupplyFailurePower supply has detected a failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2185 |
alertPowerSupplyWarningPower supply has detected a warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2186 |
alertPowerSupplyNormalPower supply has returned to normal. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2187 |
alertIntegratedDualSDModuleFailureIntegrated Dual SD Module failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2209 |
alertIntegratedDualSDModuleWarningIntegrated Dual SD Module warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2210 |
alertIntegratedDualSDModuleInformationIntegrated Dual SD Module information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2211 |
alertBatteryFailureBattery has failed or battery is absent. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2225 |
alertBatteryWarningBattery is low. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2226 |
alertBatteryNormalBattery state has returned to normal; or battery presence had been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2227 |
alertAutomaticSystemRecoveryAutomatic system recovery (ASR) was performed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2233 |
alertProcessorDeviceStatusFailureProcessor device status has detected a failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2241 |
alertProcessorDeviceStatusWarningProcessor device status has detected a warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2242 |
alertProcessorDeviceStatusNormalProcessor device status has returned to normal. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2243 |
alertLinkStatusFailureLink status failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2249 |
alertLinkStatusWarningLink status warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2250 |
alertLinkStatusInformationLink status information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2251 |
alertMemoryDeviceFailureMemory device status is critical. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2265 |
alertMemoryDeviceWarningMemory device status is noncritical. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2266 |
alertMemoryDeviceInformationMemory device informational event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2267 |
alertPowerUsageFailureThe system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2273 |
alertPowerUsageWarningSystem performance degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2274 |
alertPowerUsageInformationSystem performance restored. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2275 |
alertPhysicalDiskFailurePhysical disk failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2297 |
alertPhysicalDiskWarningPhysical disk warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2298 |
alertPhysicalDiskInformationPhysical disk information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2299 |
alertHardwareConfigurationFailureHardware configuration failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2329 |
alertHardwareConfigurationWarningHardware configuration warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2330 |
alertHardwareConfigurationInformationHardware configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2331 |
alertSoftwareConfigurationFailureSoftware configuration failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2337 |
alertSoftwareConfigurationWarningSoftware configuration warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2338 |
alertSoftwareConfigurationInformationSoftware configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2339 |
alertSystemEventLogFailureSystem Event Log failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2377 |
alertSystemEventLogWarningSystem Event Log warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2378 |
alertSystemEventLogInformationSystem Event Log information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2379 |
alertSecurityFailureSecurity failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2385 |
alertSecurityWarningSecurity warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2386 |
alertSecurityInformationSecurity information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2387 |
alertCableFailureCable failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2393 |
alertOSFailureA critical stop occurred during OS load; or a runtime critical stop occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2409 |
alertOSInformationAn OS graceful stop occurred; or an OS graceful shut-down occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2411 |
alertPCIDeviceFailureAn error was detected for a PCI device. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2417 |
alertPCIDeviceWarningA warning event was detected for a PCI device. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2418 |
alertPCIDeviceInformationAn informational event was detected for a PCI device. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2419 |
alertBiosPostFailureSystem BIOS detected a failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2425 |
alertProcessorDeviceAbsentProcessor device is absent. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2457 |
alertPowerSupplyAbsentPower supply is absent. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2465 |
alertRedundancyLostRedundancy is lost. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2473 |
alertRedundancyDegradedRedundancy is degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2474 |
alertRedundancyInformationRedundancy information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2475 |
alertIntegratedDualSDModuleAbsentIntegrated Dual SD Module is absent. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2481 |
alertIntegratedDualSDModuleRedundancyLostIntegrated Dual SD Module redundancy is lost. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2489 |
alertIntegratedDualSDModuleRedundancyDegradedIntegrated Dual SD Module redundancy is degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2490 |
alertIntegratedDualSDModuleRedundancyInformationIntegrated Dual SD Module redundancy information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2491 |
alertvFlashMediaDeviceFailurevFlash Media device failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2505 |
alertvFlashMediaDeviceWarningvFlash Media device warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2506 |
alertvFlashMediaDeviceInformationvFlash Media device information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2507 |
alertvFlashMediaDeviceAbsentvFlash Media device is absent. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2515 |
alertTemperatureStatisticsFailureTemperature has been above the warning or critical threshold level for a long enough period of time to be considered in a critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2521 |
alertTemperatureStatisticsWarningTemperature has been above the warning or critical threshold level for a long enough period of time to be considered in a warning state. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2522 |
alertRACInformationRAC information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2531 |
alertFiberChannelFailureFiber Channel failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2537 |
alertFiberChannelWarningFiber Channel warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2538 |
alertFiberChannelInformationFiber Channel information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2539 |
alertCMCFailureChassis Management Controller detected an error. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2545 |
alertCMCWarningChassis Management Controller detected a warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2546 |
alertIOVirtualizationFailureIO Virtualization failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2553 |
alertSystemPerformanceWarningSystem Performance warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.1.0.2650 |
storageAlertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2.2 |
alertStorageManagementFailureStorage Management has detected a device independent error condition. There is no global status change associated with this trap. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4177 |
alertStorageManagementWarningStorage Management has detected a device independent warning condition. There is no global status change associated with this trap. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4178 |
alertStorageManagementInformationStorage Management Information. There is no global status change associated with this trap. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4179 |
alertStorageFanFailureFan failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4201 |
alertStorageFanWarningFan warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4202 |
alertStorageFanInformationFan information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4203 |
alertStorageTemperatureProbeFailureTemperature probe failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4209 |
alertStorageTemperatureProbeWarningTemperature probe warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4210 |
alertStorageTemperatureProbeInformationTemperature probe information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4211 |
alertStoragePowerSupplyFailurePower supply failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4233 |
alertStoragePowerSupplyWarningPower supply warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4234 |
alertStoragePowerSupplyInformationPower supply information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4235 |
alertStorageBatteryFailureBattery failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4273 |
alertStorageBatteryWarningBattery warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4274 |
alertStorageBatteryInformationBattery information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4275 |
alertStorageControllerFailureController failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4329 |
alertStorageControllerWarningController warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4330 |
alertStorageControllerInformationController information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4331 |
alertStorageEnclosureFailureEnclosure failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4337 |
alertStorageEnclosureWarningEnclosure warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4338 |
alertStorageEnclosureInformationEnclosure information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4339 |
alertStoragePhysicalDiskFailurePhysical disk failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4345 |
alertStoragePhysicalDiskWarningPhysical disk warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4346 |
alertStoragePhysicalDiskInformationPhysical disk information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4347 |
alertStorageVirtualDiskFailureVirtual disk failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4353 |
alertStorageVirtualDiskWarningVirtual disk warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4354 |
alertStorageVirtualDiskInformationVirtual disk information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4355 |
alertStorageSecurityFailureStorage Security failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4433 |
alertStorageSecurityWarningStorage Security warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4434 |
alertStorageSecurityInformationStorage Security information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.2.0.4435 |
updatesAlertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2.3 |
alertUpdateJobInformationUpdate job information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.3.0.6211 |
alertSoftwareChangeUpdateWarningSoftware change update warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.3.0.6314 |
auditAlertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2.4 |
alertPowerSupplyAuditFailurePower Supply audit failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8329 |
alertPowerSupplyAuditWarningPower Supply audit warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8330 |
alertPowerUsageAuditFailurePower usage audit failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8417 |
alertPowerUsageAuditWarningPower usage audit warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8418 |
alertPowerUsageAuditInformationPower usage audit information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8419 |
alertUserTrackingWarningUser Tracking warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8490 |
alertiDRACIPAddressChangeiDRAC IP address has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8499 |
alertLicenseFailureLicense failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8513 |
alertLicenseWarningLicense warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8514 |
alertLicenseInformationLicense information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8515 |
alertPCIDeviceAuditWarningPCI device audit warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8562 |
alertSystemPowerStateChangeInformationHost is going through a power state change (powering on or powering off). NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8579 |
alertDebugWarningDebug authorization failed. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8594 |
alertDebugInformationDebug authorized. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8595 |
alertCMCAuditFailureChassis Management Controller audit failure or critical event. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8689 |
alertCMCAuditWarningChassis Management Controller audit warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8690 |
alertCMCAuditInformationChassis Management Controller audit information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.4.0.8691 |
configurationAlertTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.3.2.5 |
alertJobControlConfigurationInformationJob Control configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10267 |
alertTestTrapEventThe iDRAC generated a test trap event in response to a user request. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10395 |
alertSWCConfigurationFailureSoftware configuration failure. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10529 |
alertSWCConfigurationWarningSoftware configuration warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10530 |
alertIPAddressConfigurationInformationIP Address configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10547 |
alertSecurityConfigurationWarningSecurity configuration warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10578 |
alertPCIDeviceConfigurationInformationPCI device configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10611 |
alertAutoDiscoveryInformationAuto discovery information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10635 |
alertNetworkConfigurationWarningNetwork configuration warning. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10770 |
alertNetworkConfigurationInformationNetwork configuration information. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10892.5.3.2.5.0.10771 |
systemDetailsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4 |
mIBVersionGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.1 |
mIBMajorVersionNumber0001.0001 This attribute defines the major version number for the version of this MIB supported by the iDRAC.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1.1 |
mIBMinorVersionNumber0001.0002 This attribute defines the minor version number for the version of this MIB supported by the iDRAC.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1.2 |
mIBMaintenanceVersionNumber0001.0003 This attribute defines the maintenance version number for the version of this MIB supported by the iDRAC.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1.3 |
systemStateGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.200 |
systemStateTable0200.0010 This object defines the System State Table. SEQUENCE OF SystemStateTableEntry .1.3.6.1.4.1.674.10892.5.4.200.10 |
systemStateTableEntry0200.0010.0001 This object defines the System State Table Entry. SystemStateTableEntry .1.3.6.1.4.1.674.10892.5.4.200.10.1 |
systemStatechassisIndex0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.200.10.1.1 |
systemStateGlobalSystemStatus0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.2 |
systemStateChassisState0200.0010.0001.0003 This attribute defines the state settings of this system chassis.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.200.10.1.3 |
systemStateChassisStatus0200.0010.0001.0004 This attribute defines the status of this system chassis.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.4 |
systemStatePowerUnitStateDetails0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a power unit. The first byte returned represents the state settings of the first power unit, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.5 |
systemStatePowerUnitStatusRedundancy0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system.ro StatusRedundancyEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.6 |
systemStatePowerUnitStatusDetails0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the redundancy status of a power unit. The first byte returned represents the redundancy status of the first power unit, etc. The bytes have the same definition type as StatusRedundancyEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.7 |
systemStatePowerSupplyStateDetails0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a power supply. The first byte returned represents the state settings of the first power supply, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.8 |
systemStatePowerSupplyStatusCombined0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.9 |
systemStatePowerSupplyStatusDetails0200.0010.0001.0010 This attribute lists the status of each power supply of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a power supply. The first byte returned represents the status of the first power supply, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.10 |
systemStateVoltageStateDetails0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a voltage probe. The first byte returned represents the state settings of the first voltage probe, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.11 |
systemStateVoltageStatusCombined0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.12 |
systemStateVoltageStatusDetails0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a voltage probe. The first byte returned represents the status of the first voltage probe, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.13 |
systemStateAmperageStateDetails0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of an amperage probe. The first byte returned represents the state settings of the first amperage probe, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.14 |
systemStateAmperageStatusCombined0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.15 |
systemStateAmperageStatusDetails0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an amperage probe. The first byte returned represents the status of the first amperage probe, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.16 |
systemStateCoolingUnitStateDetails0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a cooling unit. The first byte returned represents the state settings of the first cooling unit, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.17 |
systemStateCoolingUnitStatusRedundancy0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system.ro StatusRedundancyEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.18 |
systemStateCoolingUnitStatusDetails0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the redundancy status of a cooling unit. The first byte returned represents the redundancy status of the first cooling unit, etc. The bytes have the same definition type as StatusRedundancyEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.19 |
systemStateCoolingDeviceStateDetails0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a cooling device. The first byte returned represents the state settings of the first cooling device, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.20 |
systemStateCoolingDeviceStatusCombined0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.21 |
systemStateCoolingDeviceStatusDetails0200.0010.0001.0022 This attribute lists the status of each cooling device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling device. The first byte returned represents the status of the first cooling device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.22 |
systemStateTemperatureStateDetails0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a temperature probe. The first byte returned represents the state settings of the first temperature probe, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.23 |
systemStateTemperatureStatusCombined0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.24 |
systemStateTemperatureStatusDetails0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a temperature probe. The first byte returned represents the status of the first temperature probe, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.25 |
systemStateMemoryDeviceStateDetails0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a memory device. The first byte returned represents the state settings of the first memory device, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.26 |
systemStateMemoryDeviceStatusCombined0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.27 |
systemStateMemoryDeviceStatusDetails0200.0010.0001.0028 This attribute lists the status of each memory device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a memory device. The first byte returned represents the status of the first memory device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.28 |
systemStateChassisIntrusionStateDetails0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis. The results are returned as a binary octet string where each byte of the octet string represents the state settings of an intrusion detection device. The first byte returned represents the state settings of the first intrusion detection device, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.29 |
systemStateChassisIntrusionStatusCombined0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.30 |
systemStateChassisIntrusionStatusDetails0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an intrusion detection device. The first byte returned represents the status of the first intrusion detection device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.31 |
systemStatePowerUnitStatusCombined0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.42 |
systemStatePowerUnitStatusList0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.43 |
systemStateCoolingUnitStatusCombined0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.44 |
systemStateCoolingUnitStatusList0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.45 |
systemStateProcessorDeviceStatusCombined0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.50 |
systemStateProcessorDeviceStatusList0200.0010.0001.0051 This attribute lists the status of each processor device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device. The first byte returned represents the status of the first processor device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.51 |
systemStateBatteryStatusCombined0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.52 |
systemStateBatteryStatusList0200.0010.0001.0053 This attribute lists the status of each battery of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.53 |
systemStateSDCardUnitStatusCombined0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.54 |
systemStateSDCardUnitStatusList0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card unit. The first byte returned represents the status of the first SD Card unit, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.55 |
systemStateSDCardDeviceStatusCombined0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.56 |
systemStateSDCardDeviceStatusList0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.57 |
systemStateIDSDMCardUnitStatusCombined0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.58 |
systemStateIDSDMCardUnitStatusList0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an IDSDM Card unit. The first byte returned represents the status of the first IDSDM Card unit, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.59 |
systemStateIDSDMCardDeviceStatusCombined0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.60 |
systemStateIDSDMCardDeviceStatusList0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an IDSDM Card device. The first byte returned represents the status of the first IDSDM Card device, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.61 |
systemStateTemperatureStatisticsStateDetails0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a temperature statistics object. The first byte returned represents the state settings of the first temperature statistics object, etc. The bytes have the same definition type as StateSettingsFlags.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.62 |
systemStateTemperatureStatisticsStatusCombined0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.200.10.1.63 |
systemStateTemperatureStatisticsStatusDetails0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a temperature statistics object. The first byte returned represents the status of the first temperature statistics object, etc. The bytes have the same definition type as ObjectStatusEnum.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.200.10.1.64 |
chassisInformationGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.300 |
numEventLogEntries0300.0001.0000 This attribute provides the number of entries currently in the eventLogTable.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.300.1 |
numLCLogEntries0300.0002.0000 This attribute provides the number of entries currently in the lcLogTable. Note: This attribute can only be accessed via SNMPv3 queries.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.300.2 |
chassisInformationTable0300.0010 This object defines the Chassis Information Table. SEQUENCE OF ChassisInformationTableEntry .1.3.6.1.4.1.674.10892.5.4.300.10 |
chassisInformationTableEntry0300.0010.0001 This object defines the Chassis Information Table Entry. ChassisInformationTableEntry .1.3.6.1.4.1.674.10892.5.4.300.10.1 |
chassisIndexChassisInformation0300.0010.0001.0001 This attribute defines the index (one based) of the system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.1 |
chassisStateCapabilities0300.0010.0001.0002 This attribute defines the state capabilities of the system chassis.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.2 |
chassisStateSettings0300.0010.0001.0003 This attribute defines the state settings of the system chassis.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.3 |
chassisStatus0300.0010.0001.0004 This attribute defines the status of the system chassis.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.10.1.4 |
chassisparentIndexReference0300.0010.0001.0005 This attribute defines the index (one based) to the parent system of this system chassis, if any.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.5 |
chassisType0300.0010.0001.0006 This attribute defines the system type of the system chassis.ro ChassisTypeEnum .1.3.6.1.4.1.674.10892.5.4.300.10.1.6 |
chassisName0300.0010.0001.0007 This attribute defines the user-assigned name of the system chassis.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.7 |
chassisManufacturerName0300.0010.0001.0008 This attribute defines the name of the manufacturer of the system chassis.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.8 |
chassisModelTypeName0300.0010.0001.0009 This attribute defines the system model type of the system chassis.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.9 |
chassisAssetTagName0300.0010.0001.0010 This attribute defines the asset tag name of the system chassis.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.10.1.10 |
chassisServiceTagName0300.0010.0001.0011 This attribute defines the service tag name of the system chassis.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.10.1.11 |
chassisID0300.0010.0001.0012 This attribute defines the system ID. If the value is 254 (0xFE), the attribute systemIDExtension provides the system ID.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.12 |
chassisIDExtension0300.0010.0001.0013 This attribute defines the system ID extension.ro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.13 |
chassisSystemClass0300.0010.0001.0014 This attribute defines the system class.ro ChassisSystemClassEnum .1.3.6.1.4.1.674.10892.5.4.300.10.1.14 |
chassisSystemName0300.0010.0001.0015 This attribute defines the host name of the system chassis.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.15 |
chassisLEDControlCapabilitiesUnique0300.0010.0001.0024 This attribute defines the capabilities of the LED control hardware in the system chassis.ro LEDControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.24 |
chassisLEDControlSettingsUnique0300.0010.0001.0025 This attribute defines the reading and setting of the LED control hardware in the system chassis.ro LEDControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.25 |
chassisIdentifyFlashControlCapabilities0300.0010.0001.0028 This attribute defines if the system allows setting of the system front panel LED to flash.ro ChassisIdentifyControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.28 |
chassisIdentifyFlashControlSettings0300.0010.0001.0029 This attribute setting causes the system front panel LED to flash.ro ChassisIdentifyControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.29 |
chassisLockPresent0300.0010.0001.0030 If true, a system lock is present on the system chassis.ro BooleanType .1.3.6.1.4.1.674.10892.5.4.300.10.1.30 |
chassishostControlCapabilitiesUnique0300.0010.0001.0031 This attribute defines the capabilities of the host control function.ro HostControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.31 |
chassishostControlSettingsUnique0300.0010.0001.0032 This attribute defines the settings of the host control function.ro HostControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.32 |
chassiswatchDogControlCapabilitiesUnique0300.0010.0001.0033 This attribute defines the capabilities of the watchdog control function.ro WatchDogControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.33 |
chassiswatchDogControlSettingsUnique0300.0010.0001.0034 This attribute defines the settings of the watchdog control function.ro WatchControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.34 |
chassiswatchDogControlExpiryTimeCapabilitiesUnique0300.0010.0001.0035 This attribute defines the capabilities of the watchdog control expiry timer function.ro WatchDogTimerCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.35 |
chassiswatchDogControlExpiryTime0300.0010.0001.0036 This attribute defines the current watchdog timer value in seconds.ro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.36 |
chassisPowerButtonControlCapabilitiesUnique0300.0010.0001.0038 This attribute defines the capabilities of the power button control hardware in the system chassis.ro PowerButtonControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.38 |
chassisPowerButtonControlSettingsUnique0300.0010.0001.0039 This attribute defines the reading and setting of the power button control hardware in the system chassis.ro PowerButtonControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.39 |
chassisNMIButtonControlCapabilitiesUnique0300.0010.0001.0044 This attribute defines the capabilities of the NMI button control hardware in the system chassis.ro NMIButtonControlCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.44 |
chassisNMIButtonControlSettingsUnique0300.0010.0001.0045 This attribute defines the reading and setting of the NMI button control hardware in the system chassis.ro NMIButtonControlSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.45 |
chassisSystemProperties0300.0010.0001.0046 This attribute defines the properties of the system chassis.ro SystemPropertiesFlags .1.3.6.1.4.1.674.10892.5.4.300.10.1.46 |
chassisSystemRevisionNumber0300.0010.0001.0047 This attribute defines the revision number of the system where zero indicates the original version of the system chassis. The revision number is not available on all systems.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.300.10.1.47 |
chassisSystemRevisionName0300.0010.0001.0048 This attribute defines the revision name of the system, if applicable.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.48 |
chassisExpressServiceCodeName0300.0010.0001.0049 This attribute defines the Express Service Code of the system chassis.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.10.1.49 |
eventLogTable0300.0040 This object defines the Event (ESM) Log Table. SEQUENCE OF EventLogTableEntry .1.3.6.1.4.1.674.10892.5.4.300.40 |
eventLogTableEntry0300.0040.0001 This object defines the Event (ESM) Log Table Entry. EventLogTableEntry .1.3.6.1.4.1.674.10892.5.4.300.40.1 |
eventLogchassisIndex0300.0040.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.40.1.1 |
eventLogRecordIndex0300.0040.0001.0002 This attribute defines the index (one based) of the event log record.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.300.40.1.2 |
eventLogStateCapabilitiesUnique0300.0040.0001.0003 This attribute defines the state capabilities of the object that is writing the event log.ro StateCapabilitiesLogUniqueFlags .1.3.6.1.4.1.674.10892.5.4.300.40.1.3 |
eventLogStateSettingsUnique0300.0040.0001.0004 This attribute defines the state settings of the object that is writing the event log.ro StateSettingsLogUniqueFlags .1.3.6.1.4.1.674.10892.5.4.300.40.1.4 |
eventLogRecord0300.0040.0001.0005 This attribute defines the data of the event log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.40.1.5 |
eventLogFormat0300.0040.0001.0006 This attribute defines the format of the event log record.ro LogFormatType .1.3.6.1.4.1.674.10892.5.4.300.40.1.6 |
eventLogSeverityStatus0300.0040.0001.0007 This attribute defines the severity of the event log record.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.40.1.7 |
eventLogDateName0300.0040.0001.0008 This attribute defines the date and time of the event log record.ro DateName .1.3.6.1.4.1.674.10892.5.4.300.40.1.8 |
systemBIOSTable0300.0050 This object defines the System BIOS Table. SEQUENCE OF SystemBIOSTableEntry .1.3.6.1.4.1.674.10892.5.4.300.50 |
systemBIOSTableEntry0300.0050.0001 This object defines the System BIOS Table Entry. SystemBIOSTableEntry .1.3.6.1.4.1.674.10892.5.4.300.50.1 |
systemBIOSchassisIndex0300.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.50.1.1 |
systemBIOSIndex0300.0050.0001.0002 This attribute defines the index (one based) of the system BIOS.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.50.1.2 |
systemBIOSStateCapabilities0300.0050.0001.0003 This attribute defines the state capabilities of the system BIOS.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.50.1.3 |
systemBIOSStateSettings0300.0050.0001.0004 This attribute defines the state settings of the system BIOS.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.50.1.4 |
systemBIOSStatus0300.0050.0001.0005 This attribute defines the status of the system BIOS.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.50.1.5 |
systemBIOSReleaseDateName0300.0050.0001.0007 This attribute defines the release date name of the system BIOS.ro DateName .1.3.6.1.4.1.674.10892.5.4.300.50.1.7 |
systemBIOSVersionName0300.0050.0001.0008 This attribute defines the version name of the system BIOS.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.50.1.8 |
systemBIOSManufacturerName0300.0050.0001.0011 This attribute defines the name of the manufacturer of the system BIOS.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.50.1.11 |
firmwareTable0300.0060 This object defines the Firmware Table. SEQUENCE OF FirmwareTableEntry .1.3.6.1.4.1.674.10892.5.4.300.60 |
firmwareTableEntry0300.0060.0001 This object defines the Firmware Table Entry. FirmwareTableEntry .1.3.6.1.4.1.674.10892.5.4.300.60.1 |
firmwarechassisIndex0300.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.60.1.1 |
firmwareIndex0300.0060.0001.0002 This attribute defines the index (one based) of the firmware.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.60.1.2 |
firmwareStateCapabilities0300.0060.0001.0003 This attribute defines the state capabilities of the firmware.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.60.1.3 |
firmwareStateSettings0300.0060.0001.0004 This attribute defines the state settings of the firmware.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.60.1.4 |
firmwareStatus0300.0060.0001.0005 This attribute defines the status of the firmware.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.60.1.5 |
firmwareSize0300.0060.0001.0006 This attribute defines the image size of the firmware in KBytes. Zero indicates size is unknown.ro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.300.60.1.6 |
firmwareType0300.0060.0001.0007 This attribute defines the type of firmware.ro FirmwareType .1.3.6.1.4.1.674.10892.5.4.300.60.1.7 |
firmwareTypeName0300.0060.0001.0008 This attribute defines the type name of the firmware.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.60.1.8 |
firmwareUpdateCapabilities0300.0060.0001.0009 This attribute defines the bitmap of supported methods for firmware update.ro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.300.60.1.9 |
firmwareVersionName0300.0060.0001.0011 This attribute defines the version of the firmware.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.60.1.11 |
intrusionTable0300.0070 This object defines the Intrusion Table. SEQUENCE OF IntrusionTableEntry .1.3.6.1.4.1.674.10892.5.4.300.70 |
intrusionTableEntry0300.0070.0001 This object defines the Intrusion Table Entry. IntrusionTableEntry .1.3.6.1.4.1.674.10892.5.4.300.70.1 |
intrusionchassisIndex0300.0070.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.70.1.1 |
intrusionIndex0300.0070.0001.0002 This attribute defines the index (one based) of the intrusion sensor.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.70.1.2 |
intrusionStateCapabilities0300.0070.0001.0003 This attribute defines the state capabilities of the intrusion sensor.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.300.70.1.3 |
intrusionStateSettings0300.0070.0001.0004 This attribute defines the state settings of the intrusion sensor.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.300.70.1.4 |
intrusionStatus0300.0070.0001.0005 This attribute defines the status of the intrusion sensor.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.70.1.5 |
intrusionReading0300.0070.0001.0006 This attribute defines the reading of the intrusion sensor.ro IntrusionReadingEnum .1.3.6.1.4.1.674.10892.5.4.300.70.1.6 |
intrusionType0300.0070.0001.0007 This attribute defines the type of the intrusion sensor.ro IntrusionTypeEnum .1.3.6.1.4.1.674.10892.5.4.300.70.1.7 |
intrusionLocationName0300.0070.0001.0008 This attribute defines the location of the intrusion sensor.ro String64 .1.3.6.1.4.1.674.10892.5.4.300.70.1.8 |
lcLogTable0300.0090 This object defines the Lifecycle (LC) Log Table. Lifecycle (LC) Log table records are ordered from oldest to newest. Note: This table can only be accessed via SNMPv3 queries. SEQUENCE OF LcLogTableEntry .1.3.6.1.4.1.674.10892.5.4.300.90 |
lcLogTableEntry0300.0090.0001 This object defines the Lifcycle (LC) Log Table Entry. LcLogTableEntry .1.3.6.1.4.1.674.10892.5.4.300.90.1 |
lcLogChassisIndex0300.0090.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.300.90.1.1 |
lcLogRecordIndex0300.0090.0001.0002 This attribute defines the index (one based) of the LC log record.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.300.90.1.2 |
lcLogSequenceNumber0300.0090.0001.0003 This attribute defines the LC Log sequence number of the event associated with the LC log record.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.300.90.1.3 |
lcLogCategory0300.0090.0001.0004 This attribute defines the category of the event associated with the LC log record.ro LcLogCategoryEnum .1.3.6.1.4.1.674.10892.5.4.300.90.1.4 |
lcLogSeverityStatus0300.0090.0001.0005 This attribute defines the severity of the event associated with the LC log record.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.300.90.1.5 |
lcLogDateName0300.0090.0001.0006 This attribute defines the date and time of the event associated with the LC log record.ro DateName .1.3.6.1.4.1.674.10892.5.4.300.90.1.6 |
lcLogFQDD0300.0090.0001.0007 Fully qualified device descriptor (FQDD) of the device associated with the event associated with the LC log record.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.300.90.1.7 |
lcLogMessageID0300.0090.0001.0008 This attribute defines the Message ID of the event associated with the LC log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.90.1.8 |
lcLogMessage0300.0090.0001.0009 This attribute defines the message of the event associated with the LC log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.90.1.9 |
lcLogDetailedDescription0300.0090.0001.0010 This attribute defines the detailed description of the event associated with the LC log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.90.1.10 |
lcLogRecommededAction0300.0090.0001.0011 This attribute defines an optional recommended action associated with the event associated with the LC log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.90.1.11 |
lcLogComment0300.0090.0001.0012 This attribute defines an optional user comment associated with the event associated with the LC log record.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.300.90.1.12 |
powerGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.600 |
powerUnitTable0600.0010 This object defines the Power Unit Table. SEQUENCE OF PowerUnitTableEntry .1.3.6.1.4.1.674.10892.5.4.600.10 |
powerUnitTableEntry0600.0010.0001 This object defines the Power Unit Table Entry. PowerUnitTableEntry .1.3.6.1.4.1.674.10892.5.4.600.10.1 |
powerUnitchassisIndex0600.0010.0001.0001 This attribute defines the index (one based) of the system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.10.1.1 |
powerUnitIndex0600.0010.0001.0002 This attribute defines the index (one based) of the power unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.10.1.2 |
powerUnitStateCapabilities0600.0010.0001.0003 This attribute defines the state capabilities of the power unit.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.10.1.3 |
powerUnitStateSettings0600.0010.0001.0004 This attribute defines the state settings of the power unit.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.600.10.1.4 |
powerUnitRedundancyStatus0600.0010.0001.0005 This attribute defines the redundancy status of the power unit.ro StatusRedundancyEnum .1.3.6.1.4.1.674.10892.5.4.600.10.1.5 |
powerSupplyCountForRedundancy0600.0010.0001.0006 This attribute defines the total number of power supplies required for this power unit to have full redundancy.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.10.1.6 |
powerUnitName0600.0010.0001.0007 This attribute defines the name of the power unit.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.10.1.7 |
powerUnitStatus0600.0010.0001.0008 This attribute defines the status of the power unit.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.600.10.1.8 |
powerSupplyTable0600.0012 This object defines the Power Supply Table. SEQUENCE OF PowerSupplyTableEntry .1.3.6.1.4.1.674.10892.5.4.600.12 |
powerSupplyTableEntry0600.0012.0001 This object defines the Power Supply Table Entry. PowerSupplyTableEntry .1.3.6.1.4.1.674.10892.5.4.600.12.1 |
powerSupplychassisIndex0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.1 |
powerSupplyIndex0600.0012.0001.0002 This attribute defines the index (one based) of the power supply.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.2 |
powerSupplyStateCapabilitiesUnique0600.0012.0001.0003 This attribute defines the state capabilities of the power supply.ro PowerSupplyStateCapabilitiesUniqueFlags .1.3.6.1.4.1.674.10892.5.4.600.12.1.3 |
powerSupplyStateSettingsUnique0600.0012.0001.0004 This attribute defines the state settings of the power supply.ro PowerSupplyStateSettingsUniqueFlags .1.3.6.1.4.1.674.10892.5.4.600.12.1.4 |
powerSupplyStatus0600.0012.0001.0005 This attribute defines the status of the power supply.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.600.12.1.5 |
powerSupplyOutputWatts0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts).ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.6 |
powerSupplyType0600.0012.0001.0007 This attribute defines the type of the power supply.ro PowerSupplyTypeEnum .1.3.6.1.4.1.674.10892.5.4.600.12.1.7 |
powerSupplyLocationName0600.0012.0001.0008 This attribute defines the location of the power supply.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.12.1.8 |
powerSupplyMaximumInputVoltage0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts).ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.9 |
powerSupplypowerUnitIndexReference0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.10 |
powerSupplySensorState0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUnique.ro PowerSupplySensorStateFlags .1.3.6.1.4.1.674.10892.5.4.600.12.1.11 |
powerSupplyConfigurationErrorType0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor. When the configurationError bit is on in the value for the attribute powerSupplySensorState, a value is returned for this attribute; otherwise, a value is not returned for this attribute.ro PowerSupplyConfigurationErrorTypeEnum .1.3.6.1.4.1.674.10892.5.4.600.12.1.12 |
powerSupplyPowerMonitorCapable0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption.ro BooleanType .1.3.6.1.4.1.674.10892.5.4.600.12.1.13 |
powerSupplyRatedInputWattage0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts).ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.14 |
powerSupplyFQDD0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.600.12.1.15 |
powerSupplyCurrentInputVoltage0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts).ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.12.1.16 |
voltageProbeTable0600.0020 This object defines the Voltage Probe Table. SEQUENCE OF VoltageProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.600.20 |
voltageProbeTableEntry0600.0020.001 This object defines the Voltage Probe Table Entry. VoltageProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.600.20.1 |
voltageProbechassisIndex0600.0020.0001.0001 This attribute defines the index (one based) of the system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.1 |
voltageProbeIndex0600.0020.0001.0002 This attribute defines the index (one based) of the voltage probe.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.2 |
voltageProbeStateCapabilities0600.0020.0001.0003 This attribute defines the state capabilities of the voltage probe.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.20.1.3 |
voltageProbeStateSettings0600.0020.0001.0004 This attribute defines the state settings of the voltage probe.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.600.20.1.4 |
voltageProbeStatus0600.0020.0001.0005 This attribute defines the probe status of the voltage probe.ro StatusProbeEnum .1.3.6.1.4.1.674.10892.5.4.600.20.1.5 |
voltageProbeReading0600.0020.0001.0006 This attribute defines the reading for a voltage probe of type other than voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, the value returned for this attribute is the voltage that the probe is reading in millivolts. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.6 |
voltageProbeType0600.0020.0001.0007 This attribute defines the type of the voltage probe.ro VoltageTypeEnum .1.3.6.1.4.1.674.10892.5.4.600.20.1.7 |
voltageProbeLocationName0600.0020.0001.0008 This attribute defines the location name of the voltage probe.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.20.1.8 |
voltageProbeUpperNonRecoverableThreshold0600.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.9 |
voltageProbeUpperCriticalThreshold0600.0020.0001.0010 This attribute defines the upper critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.10 |
voltageProbeUpperNonCriticalThreshold0600.0020.0001.0011 This attribute defines the upper noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.11 |
voltageProbeLowerNonCriticalThreshold0600.0020.0001.0012 This attribute defines the lower noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.12 |
voltageProbeLowerCriticalThreshold0600.0020.0001.0013 This attribute defines the lower critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.13 |
voltageProbeLowerNonRecoverableThreshold0600.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.20.1.14 |
voltageProbeProbeCapabilities0600.0020.0001.0015 This attribute defines the probe capabilities of the voltage probe.ro ProbeCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.20.1.15 |
voltageProbeDiscreteReading0600.0020.0001.0016 This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.ro VoltageDiscreteReadingEnum .1.3.6.1.4.1.674.10892.5.4.600.20.1.16 |
amperageProbeTable0600.0030 This object defines the Amperage Probe Table. SEQUENCE OF AmperageProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.600.30 |
amperageProbeTableEntry0600.0030.0001 This object defines the Amperage Probe Table Entry. AmperageProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.600.30.1 |
amperageProbechassisIndex0600.0030.0001.0001 This attribute defines the index (one based) of the system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.1 |
amperageProbeIndex0600.0030.0001.0002 This attribute defines the index (one based) of the amperage probe.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.2 |
amperageProbeStateCapabilities0600.0030.0001.0003 This attribute defines the state capabilities of the amperage probe.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.30.1.3 |
amperageProbeStateSettings0600.0030.0001.0004 This attribute defines the state settings of the amperage probe.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.600.30.1.4 |
amperageProbeStatus0600.0030.0001.0005 This attribute defines the probe status of the amperage probe.ro StatusProbeEnum .1.3.6.1.4.1.674.10892.5.4.600.30.1.5 |
amperageProbeReading0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amps. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the power usage that the probe is reading in Watts. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperageProbeTypeIsPowerSupplyAmps, amperageProbeTypeIsPowerSupplyWatts, amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.6 |
amperageProbeType0600.0030.0001.0007 This attribute defines the type of the amperage probe.ro AmperageProbeTypeEnum .1.3.6.1.4.1.674.10892.5.4.600.30.1.7 |
amperageProbeLocationName0600.0030.0001.0008 This attribute defines the location of the amperage probe.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.30.1.8 |
amperageProbeUpperNonRecoverableThreshold0600.0030.0001.0009 This attribute defines the upper nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.9 |
amperageProbeUpperCriticalThreshold0600.0030.0001.0010 This attribute defines the upper critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.10 |
amperageProbeUpperNonCriticalThreshold0600.0030.0001.0011 This attribute defines the upper noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.11 |
amperageProbeLowerNonCriticalThreshold0600.0030.0001.0012 This attribute defines the lower noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.12 |
amperageProbeLowerCriticalThreshold0600.0030.0001.0013 This attribute defines the lower critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.13 |
amperageProbeLowerNonRecoverableThreshold0600.0030.0001.0014 This attribute defines the lower nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.600.30.1.14 |
amperageProbeProbeCapabilities0600.0030.0001.0015 This attribute defines the probe capabilities of the amperage probe.ro ProbeCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.30.1.15 |
amperageProbeDiscreteReading0600.0030.0001.0016 This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.ro AmperageDiscreteReadingEnum .1.3.6.1.4.1.674.10892.5.4.600.30.1.16 |
systemBatteryTable0600.0050 This object defines the System Battery Table. SEQUENCE OF SystemBatteryTableEntry .1.3.6.1.4.1.674.10892.5.4.600.50 |
systemBatteryTableEntry0600.0050.0001 This object defines the System Battery Table Entry. SystemBatteryTableEntry .1.3.6.1.4.1.674.10892.5.4.600.50.1 |
systemBatteryChassisIndex0600.0050.0001.0001 This attribute defines the index (one based) of the system chassis that contains the battery.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.50.1.1 |
systemBatteryIndex0600.0050.0001.0002 This attribute defines the index (one based) of the battery.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.50.1.2 |
systemBatteryStateCapabilities0600.0050.0001.0003 This attribute defines the state capabilities of the battery.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.50.1.3 |
systemBatteryStateSettings0600.0050.0001.0004 This attribute defines the state settings of the battery.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.600.50.1.4 |
systemBatteryStatus0600.0050.0001.0005 This attribute defines the status of the battery.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.600.50.1.5 |
systemBatteryReading0600.0050.0001.0006 This attribute defines the reading of the battery.ro SystemBatteryReadingFlags .1.3.6.1.4.1.674.10892.5.4.600.50.1.6 |
systemBatteryLocationName0600.0050.0001.0007 This attribute defines the location of the battery.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.50.1.7 |
powerUsageTable0600.0060 This object defines the Power Usage Table. SEQUENCE OF PowerUsageTableEntry .1.3.6.1.4.1.674.10892.5.4.600.60 |
powerUsageTableEntry0600.0060.0001 This object defines the Power Usage Table Entry. PowerUsageTableEntry .1.3.6.1.4.1.674.10892.5.4.600.60.1 |
powerUsageChassisIndex0600.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.1 |
powerUsageIndex0600.0060.0001.0002 This attribute defines the index (one based) of the power usage information.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.2 |
powerUsageStateCapabilities0600.0060.0001.0003 This attribute defines the state capabilities of the power usage information.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.60.1.3 |
powerUsageStateSettings0600.0060.0001.0004 This attribute defines the state settings of the power usage information.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.600.60.1.4 |
powerUsageStatus0600.0060.0001.0005 This attribute defines the status of the power usage information.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.600.60.1.5 |
powerUsageEntityName0600.0060.0001.0006 This attribute defines the name of the entity associated with this power usage information.ro String64 .1.3.6.1.4.1.674.10892.5.4.600.60.1.6 |
powerUsageCumulativeWattage0600.0060.0001.0007 This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.7 |
powerUsageCumulativeWattageStartDateName0600.0060.0001.0008 This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute.ro DateName .1.3.6.1.4.1.674.10892.5.4.600.60.1.8 |
powerUsagePeakWatts0600.0060.0001.0009 This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.9 |
powerUsagePeakWattsStartDateName0600.0060.0001.0010 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute.ro DateName .1.3.6.1.4.1.674.10892.5.4.600.60.1.10 |
powerUsagePeakWattsReadingDateName0600.0060.0001.0011 This attribute defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured.ro DateName .1.3.6.1.4.1.674.10892.5.4.600.60.1.11 |
powerUsagePeakAmps0600.0060.0001.0012 This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.12 |
powerUsagePeakAmpsStartDateName0600.0060.0001.0013 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute.ro DateName .1.3.6.1.4.1.674.10892.5.4.600.60.1.13 |
powerUsagePeakAmpsReadingDateName0600.0060.0001.0014 This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured.ro DateName .1.3.6.1.4.1.674.10892.5.4.600.60.1.14 |
powerUsageIdlePower0600.0060.0001.0015 This attribute defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.15 |
powerUsageMaxPotentialPower0600.0060.0001.0016 This attribute defines the system maximum potential power (in Watts). This is the maximum power the system can consume based on the current hardware configuration.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.16 |
powerUsagePowerCapCapabilities0600.0060.0001.0017 This attribute defines the system power cap capabilities.ro PowerCapCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.600.60.1.17 |
powerUsagePowerCapSetting0600.0060.0001.0018 This attribute defines the system power cap setting.ro PowerCapSettingEnum .1.3.6.1.4.1.674.10892.5.4.600.60.1.18 |
powerUsagePowerCapValue0600.0060.0001.0019 This attribute defines the system power cap value (in Watts).ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.19 |
powerUsageInstantaneousHeadroom0600.0060.0001.0020 This attribute defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.20 |
powerUsagePeakHeadroom0600.0060.0001.0021 This attribute defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak power draw.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.600.60.1.21 |
thermalGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.700 |
coolingUnitTable0700.0010 This object defines the Cooling Unit Table. SEQUENCE OF CoolingUnitTableEntry .1.3.6.1.4.1.674.10892.5.4.700.10 |
coolingUnitTableEntry0700.0010.0001 This object defines the Cooling Unit Table Entry. CoolingUnitTableEntry .1.3.6.1.4.1.674.10892.5.4.700.10.1 |
coolingUnitchassisIndex0700.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.10.1.1 |
coolingUnitIndex0700.0010.0001.0002 This attribute defines the index (one based) of the cooling unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.10.1.2 |
coolingUnitStateCapabilties0700.0010.0001.0003 This attribute defines the state capabilities of the cooling unit.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.700.10.1.3 |
coolingUnitStateSettings0700.0010.0001.0004 This attribute defines the state settings of the cooling unit.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.700.10.1.4 |
coolingUnitRedundancyStatus0700.0010.0001.0005 This attribute defines the redundancy status of the cooling unit.ro StatusRedundancyEnum .1.3.6.1.4.1.674.10892.5.4.700.10.1.5 |
coolingDeviceCountForRedundancy0700.0010.0001.0006 This attribute defines the total number of cooling devices required for this cooling unit to have full redundancy.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.10.1.6 |
coolingUnitName0700.0010.0001.0007 This attribute defines the name of the cooling unit.ro String64 .1.3.6.1.4.1.674.10892.5.4.700.10.1.7 |
coolingUnitStatus0700.0010.0001.0008 This attribute defines the status of the cooling unit.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.700.10.1.8 |
coolingDeviceTable0700.0012 This object defines the Cooling Device Table. SEQUENCE OF CoolingDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.700.12 |
coolingDeviceTableEntry0700.0012.0001 This object defines the Cooling Device Table Entry. CoolingDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.700.12.1 |
coolingDevicechassisIndex0700.0012.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.1 |
coolingDeviceIndex0700.0012.0001.0002 This attribute defines the index (one based) of the cooling device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.2 |
coolingDeviceStateCapabilities0700.0012.0001.0003 This attribute defines the state capabilities of the cooling device.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.700.12.1.3 |
coolingDeviceStateSettings0700.0012.0001.0004 This attribute defines the state settings of the cooling device.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.700.12.1.4 |
coolingDeviceStatus0700.0012.0001.0005 This attribute defines the probe status of the cooling device.ro StatusProbeEnum .1.3.6.1.4.1.674.10892.5.4.700.12.1.5 |
coolingDeviceReading0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.6 |
coolingDeviceType0700.0012.0001.0007 This attribute defines the type of the cooling device.ro CoolingDeviceTypeEnum .1.3.6.1.4.1.674.10892.5.4.700.12.1.7 |
coolingDeviceLocationName0700.0012.0001.0008 This attribute defines the location name of the cooling device.ro String64 .1.3.6.1.4.1.674.10892.5.4.700.12.1.8 |
coolingDeviceUpperNonRecoverableThreshold0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.9 |
coolingDeviceUpperCriticalThreshold0700.0012.0001.0010 This attribute defines the upper critical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.10 |
coolingDeviceUpperNonCriticalThreshold0700.0012.0001.0011 This attribute defines the upper noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.11 |
coolingDeviceLowerNonCriticalThreshold0700.0012.0001.0012 This attribute defines the lower noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.12 |
coolingDeviceLowerCriticalThreshold0700.0012.0001.0013 This attribute defines the lower critical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.13 |
coolingDeviceLowerNonRecoverableThreshold0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.14 |
coolingDevicecoolingUnitIndexReference0700.0012.0001.0015 This attribute defines the index to the associated cooling unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.12.1.15 |
coolingDeviceSubType0700.0012.0001.0016 This attribute defines the subtype of the cooling device.ro CoolingDeviceSubTypeEnum .1.3.6.1.4.1.674.10892.5.4.700.12.1.16 |
coolingDeviceProbeCapabilities0700.0012.0001.0017 This attribute defines the probe capabilities of the cooling device.ro ProbeCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.700.12.1.17 |
coolingDeviceDiscreteReading0700.0012.0001.0018 This attribute defines the reading for a cooling device of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the discrete reading for the cooling device.ro CoolingDeviceDiscreteReadingEnum .1.3.6.1.4.1.674.10892.5.4.700.12.1.18 |
coolingDeviceFQDD0700.0012.0001.0019 Fully qualified device descriptor (FQDD) of the cooling device.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.700.12.1.19 |
temperatureProbeTable0700.0020 This object defines the Temperature Probe Table. SEQUENCE OF TemperatureProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.700.20 |
temperatureProbeTableEntry0700.0020.0001 This object defines the Temperature Probe Table Entry. TemperatureProbeTableEntry .1.3.6.1.4.1.674.10892.5.4.700.20.1 |
temperatureProbechassisIndex0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.1 |
temperatureProbeIndex0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.2 |
temperatureProbeStateCapabilities0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.700.20.1.3 |
temperatureProbeStateSettings0700.0020.0001.0004 This attribute defines the state settings of the temperature probe.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.700.20.1.4 |
temperatureProbeStatus0700.0020.0001.0005 This attribute defines the probe status of the temperature probe.ro StatusProbeEnum .1.3.6.1.4.1.674.10892.5.4.700.20.1.5 |
temperatureProbeReading0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.6 |
temperatureProbeType0700.0020.0001.0007 This attribute defines the type of the temperature probe.ro TemperatureProbeTypeEnum .1.3.6.1.4.1.674.10892.5.4.700.20.1.7 |
temperatureProbeLocationName0700.0020.0001.0008 This attribute defines the location name of the temperature probe.ro String64 .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 |
temperatureProbeUpperNonRecoverableThreshold0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.9 |
temperatureProbeUpperCriticalThreshold0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.10 |
temperatureProbeUpperNonCriticalThreshold0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.11 |
temperatureProbeLowerNonCriticalThreshold0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.12 |
temperatureProbeLowerCriticalThreshold0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.13 |
temperatureProbeLowerNonRecoverableThreshold0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.700.20.1.14 |
temperatureProbeProbeCapabilities0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe.ro ProbeCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.700.20.1.15 |
temperatureProbeDiscreteReading0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.ro TemperatureDiscreteReadingEnum .1.3.6.1.4.1.674.10892.5.4.700.20.1.16 |
deviceGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.1100 |
processorDeviceTable1100.0030 This object defines the Processor Device Table. SEQUENCE OF ProcessorDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.30 |
processorDeviceTableEntry1100.0030.0001 This object defines the Processor Device Table Entry. ProcessorDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.30.1 |
processorDevicechassisIndex1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 |
processorDeviceIndex1100.0030.0001.0002 This attribute defines the index (one based) of the processor device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 |
processorDeviceStateCapabilities1100.0030.0001.0003 This attribute defines the state capabilities of the processor device.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 |
processorDeviceStateSettings1100.0030.0001.0004 This attribute defines the state settings of the processor device.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 |
processorDeviceStatus1100.0030.0001.0005 This attribute defines the status of the processor device.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 |
processorDeviceType1100.0030.0001.0007 This attribute defines the type of the processor device.ro ProcessorDeviceType .1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 |
processorDeviceManufacturerName1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 |
processorDeviceStatusState1100.0030.0001.0009 This attribute defines the status state of the processor device.ro ProcessorDeviceStatusState .1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 |
processorDeviceFamily1100.0030.0001.0010 This attribute defines the family of the processor device.ro ProcessorDeviceFamily .1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 |
processorDeviceMaximumSpeed1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz. Zero indicates the maximum speed is unknown.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 |
processorDeviceCurrentSpeed1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz. Zero indicates the current speed is unknown.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 |
processorDeviceExternalClockSpeed1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz. Zero indicates the external clock speed is unknown.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 |
processorDeviceVoltage1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts. Zero indicates the voltage is unknown.ro Signed32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 |
processorDeviceVersionName1100.0030.0001.0016 This attribute defines the version of the processor device. On some systems, this value contains the brand and stepping information; on other systems, this value contains the model and stepping information.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 |
processorDeviceCoreCount1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 |
processorDeviceCoreEnabledCount1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 |
processorDeviceThreadCount1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 |
processorDeviceCharacteristics1100.0030.0001.0020 This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set, the processor charactistics are unknown and bits 2-15 cannot be used to determine if the functions associated with the bits are supported. Bit Position Meaning if Set -------- -------------- Bit 0 Reserved Bit 1 Unknown Bit 2 64-bit capable Bit 3-15 Reservedro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 |
processorDeviceExtendedCapabilities1100.0030.0001.0021 This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position Meaning if Set -------- -------------- Bit 0 Virtualization Technology (VT) supported Bit 2 eXecute Disable (XD) supported Bit 3 Hyper-Threading (HT) supported Bit 4 Turbo Mode supportedro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 |
processorDeviceExtendedSettings1100.0030.0001.0022 This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position Meaning if Set -------- -------------- Bit 0 Virtualization Technology (VT) enabled Bit 2 eXecute Disable (XD) enabled Bit 3 Hyper-Threading (HT) enabled Bit 4 Turbo Mode enabledro Unsigned16BitRange .1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 |
processorDeviceBrandName1100.0030.0001.0023 This attribute defines the brand of the processor device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 |
processorDeviceFQDD1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 |
processorDeviceStatusTable1100.0032 This object defines the Processor Device Status Table. SEQUENCE OF ProcessorDeviceStatusTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.32 |
processorDeviceStatusTableEntry1100.0032.0001 This object defines the Processor Device Status Table Entry. ProcessorDeviceStatusTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.32.1 |
processorDeviceStatusChassisIndex1100.0032.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.32.1.1 |
processorDeviceStatusIndex1100.0032.0001.0002 This attribute defines the index (one based) of the processor device status probe.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.32.1.2 |
processorDeviceStatusStateCapabilities1100.0032.0001.0003 This attribute defines the state capabilities of the processor device status probe.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1100.32.1.3 |
processorDeviceStatusStateSettings1100.0032.0001.0004 This attribute defines the state settings of the processor device status probe.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.1100.32.1.4 |
processorDeviceStatusStatus1100.0032.0001.0005 This attribute defines the status of the processor device status probe. This status will be joined into the processorDeviceStatus attribute.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.32.1.5 |
processorDeviceStatusReading1100.0032.0001.0006 This attribute defines the reading of the processor device status probe.ro ProcessorDeviceStatusReadingFlags .1.3.6.1.4.1.674.10892.5.4.1100.32.1.6 |
processorDeviceStatusLocationName1100.0032.0001.0007 This attribute defines the location name of the processor device status probe.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.32.1.7 |
memoryDeviceTable1100.0050 This object defines the Memory Device Table. SEQUENCE OF MemoryDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.50 |
memoryDeviceTableEntry1100.0050.0001 This object defines the Memory Device Table Entry. MemoryDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.50.1 |
memoryDevicechassisIndex1100.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.50.1.1 |
memoryDeviceIndex1100.0050.0001.0002 This attribute defines the index (one based) of the memory device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.50.1.2 |
memoryDeviceStateCapabilities1100.0050.0001.0003 This attribute defines the state capabilities of the memory device.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1100.50.1.3 |
memoryDeviceStateSettings1100.0050.0001.0004 This attribute defines the state settings of the memory device.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.1100.50.1.4 |
memoryDeviceStatus1100.0050.0001.0005 This attribute defines the status of the memory device.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.50.1.5 |
memoryDeviceType1100.0050.0001.0007 This attribute defines the type of the memory device.ro MemoryDeviceTypeEnum .1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 |
memoryDeviceLocationName1100.0050.0001.0008 This attribute defines the location of the memory device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.50.1.8 |
memoryDeviceBankLocationName1100.0050.0001.0010 This attribute defines the location of the bank for the memory device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.50.1.10 |
memoryDeviceSize1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 |
memoryDeviceSpeed1100.0050.0001.0015 This attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.50.1.15 |
memoryDeviceManufacturerName1100.0050.0001.0021 This attribute defines the manufacturer of the memory device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.50.1.21 |
memoryDevicePartNumberName1100.0050.0001.0022 This attribute defines the manufacturer's part number for the memory device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.50.1.22 |
memoryDeviceSerialNumberName1100.0050.0001.0023 This attribute defines the serial number of the memory device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.50.1.23 |
memoryDeviceFQDD1100.0050.0001.0026 Fully qualified device descriptor (FQDD) of the memory device.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.1100.50.1.26 |
memoryDeviceCurrentOperatingSpeed1100.0050.0001.0027 This attribute defines the current operating speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.50.1.27 |
pCIDeviceTable1100.0080 This object defines the PCI Device Table. SEQUENCE OF PCIDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.80 |
pCIDeviceTableEntry1100.0080.0001 This object defines the PCI Device Table Entry. PCIDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.80.1 |
pCIDevicechassisIndex1100.0080.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.80.1.1 |
pCIDeviceIndex1100.0080.0001.0002 This attribute defines the index (one based) of the PCI device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.80.1.2 |
pCIDeviceStateCapabilities1100.0080.0001.0003 This attribute defines the state capabilities of the PCI device.ro StateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1100.80.1.3 |
pCIDeviceStateSettings1100.0080.0001.0004 This attribute defines the state settings of the PCI device.ro StateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.1100.80.1.4 |
pCIDeviceStatus1100.0080.0001.0005 This attribute defines the status of the PCI device.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.80.1.5 |
pCIDeviceDataBusWidth1100.0080.0001.0007 This attribute defines the width of the data bus of the PCI device. This attribute contains an enumeration value. The possible values and their meanings are defined below. Value Meaning ---------- -------------- 0x00000001 Other 0x00000002 Unknown 0x00000003 8 bit 0x00000004 16 bit 0x00000005 32 bit 0x00000006 64 bit 0x00000007 128 bit 0x00000008 1x or x1 0x00000009 2x or x2 0x0000000A 4x or x4 0x0000000B 8x or x8 0x0000000C 12x or x12 0x0000000D 16x or x16 0x0000000E 32x or x32ro Unsigned32BitRange .1.3.6.1.4.1.674.10892.5.4.1100.80.1.7 |
pCIDeviceManufacturerName1100.0080.0001.0008 This attribute defines the name of the manufacturer of the PCI device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.80.1.8 |
pCIDeviceDescriptionName1100.0080.0001.0009 This attribute defines the description of the PCI device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.80.1.9 |
pCIDeviceFQDD1100.0080.0001.0012 Fully qualified device descriptor (FQDD) of the PCI device.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.1100.80.1.12 |
networkDeviceTable1100.0090 This object defines the Network Device Table. SEQUENCE OF NetworkDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.90 |
networkDeviceTableEntry1100.0090.0001 This object defines the Network Device Table Entry. NetworkDeviceTableEntry .1.3.6.1.4.1.674.10892.5.4.1100.90.1 |
networkDeviceChassisIndex1100.0090.0001.0001 This attribute defines the index (one based) of the system chassis that contains the network device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.90.1.1 |
networkDeviceIndex1100.0090.0001.0002 This attribute defines the index (one based) of the network device.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1100.90.1.2 |
networkDeviceStatus1100.0090.0001.0003 This attribute defines the status of the network device.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.90.1.3 |
networkDeviceConnectionStatus1100.0090.0001.0004 This attribute defines the connection status of the network device.ro NetworkDeviceConnectionStatusEnum .1.3.6.1.4.1.674.10892.5.4.1100.90.1.4 |
networkDeviceProductName1100.0090.0001.0006 This attribute defines the product name of the network device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.90.1.6 |
networkDeviceVendorName1100.0090.0001.0007 This attribute defines the name of the vendor of the network device.ro String64 .1.3.6.1.4.1.674.10892.5.4.1100.90.1.7 |
networkDeviceCurrentMACAddress1100.0090.0001.0015 This attribute defines the current MAC address of the network device.ro MACAddress .1.3.6.1.4.1.674.10892.5.4.1100.90.1.15 |
networkDevicePermanentMACAddress1100.0090.0001.0016 This attribute defines the permanent MAC address of the network device.ro MACAddress .1.3.6.1.4.1.674.10892.5.4.1100.90.1.16 |
networkDevicePCIBusNumber1100.0090.0001.0017 This attribute defines the PCI bus number of the network device.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1100.90.1.17 |
networkDevicePCIDeviceNumber1100.0090.0001.0018 This attribute defines the PCI device number of the network device.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1100.90.1.18 |
networkDevicePCIFunctionNumber1100.0090.0001.0019 This attribute defines the PCI function number of the network device.ro Unsigned8BitRange .1.3.6.1.4.1.674.10892.5.4.1100.90.1.19 |
networkDeviceTOECapabilityFlags1100.0090.0001.0023 This attribute defines the TCP/IP Offload Engine (TOE) capability flags of the network device.ro NetworkDeviceTOECapabilityFlags .1.3.6.1.4.1.674.10892.5.4.1100.90.1.23 |
networkDeviceiSCSICapabilityFlags1100.0090.0001.0027 This attribute defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device.ro NetworkDeviceiSCSICapabilityFlags .1.3.6.1.4.1.674.10892.5.4.1100.90.1.27 |
networkDeviceiSCSIEnabled1100.0090.0001.0028 This attribute defines if iSCSI is enabled for the network device.ro BooleanType .1.3.6.1.4.1.674.10892.5.4.1100.90.1.28 |
networkDeviceCapabilities1100.0090.0001.0029 This attribute defines the capabilities of the network device. If this value is notSupported(0), the networkDeviceTOECapabilityFlags, networkDeviceiSCSICapabilityFlags and networkDeviceiSCSIEnabled attributes should be used to determine the network device capabilities. If the supported(1) bit is on, this attribute should be used to determine the network device capabilities, and the attributes mentioned above should not be used. NOTE: For a network device on Converged Network Adapter (CNA), this attribute provides capability information for the CNA and not for the network device. For more information read vendor documentation.ro NetworkDeviceCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1100.90.1.29 |
networkDeviceFQDD1100.0090.0001.0030 Fully qualified device descriptor (FQDD) of the network device.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 |
slotGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.1200 |
systemSlotTable1200.0010 This object defines the System Slot Table. SEQUENCE OF SystemSlotTableEntry .1.3.6.1.4.1.674.10892.5.4.1200.10 |
systemSlotTableEntry1200.0010.0001 This object defines the System Slot Table Entry. SystemSlotTableEntry .1.3.6.1.4.1.674.10892.5.4.1200.10.1 |
systemSlotchassisIndex1200.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1200.10.1.1 |
systemSlotIndex1200.0010.0001.0002 This attribute defines the index (one based) of the system slot.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.1200.10.1.2 |
systemSlotStateCapabilitiesUnique1200.0010.0001.0003 This attribute defines the state capabilities of the system slot.ro SystemSlotStateCapabilitiesFlags .1.3.6.1.4.1.674.10892.5.4.1200.10.1.3 |
systemSlotStateSettingsUnique1200.0010.0001.0004 This attribute defines the state settings of the system slot.ro SystemSlotStateSettingsFlags .1.3.6.1.4.1.674.10892.5.4.1200.10.1.4 |
systemSlotStatus1200.0010.0001.0005 This attribute defines the status of the system slot.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.1200.10.1.5 |
systemSlotCurrentUsage1200.0010.0001.0006 This attribute defines the current usage of the system slot.ro SystemSlotUsageEnum .1.3.6.1.4.1.674.10892.5.4.1200.10.1.6 |
systemSlotType1200.0010.0001.0007 This attribute defines the type of the system slot.ro SystemSlotTypeEnum .1.3.6.1.4.1.674.10892.5.4.1200.10.1.7 |
systemSlotSlotExternalSlotName1200.0010.0001.0008 This attribute defines the name of the external connector name of the system slot.ro String64 .1.3.6.1.4.1.674.10892.5.4.1200.10.1.8 |
systemSlotCategory1200.0010.0001.0011 This attribute defines the category of the system slot.ro SystemSlotCategoryEnum .1.3.6.1.4.1.674.10892.5.4.1200.10.1.11 |
fruGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.4.2000 |
fruTable2000.0010 This object defines the Field Replaceable Unit table. SEQUENCE OF FruTableEntry .1.3.6.1.4.1.674.10892.5.4.2000.10 |
fruTableEntry2000.0010.0001 This object defines the Field Replaceable Unit table entry. FruTableEntry .1.3.6.1.4.1.674.10892.5.4.2000.10.1 |
fruChassisIndex2000.0010.0001.0001 This attribute defines the index (one based) of the system chassis containing the field replaceable unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.2000.10.1.1 |
fruIndex2000.0010.0001.0002 This attribute defines the index (one based) of the field replaceable unit.ro ObjectRange .1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 |
fruInformationStatus2000.0010.0001.0003 This attribute defines the status of the field replaceable unit information.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 |
fruManufacturerName2000.0010.0001.0006 This attribute defines the manufacturer of the field replaceable unit.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.2000.10.1.6 |
fruSerialNumberName2000.0010.0001.0007 This attribute defines the serial number of the field replaceable unit.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.2000.10.1.7 |
fruPartNumberName2000.0010.0001.0008 This attribute defines the part number of the field replaceable unit.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.2000.10.1.8 |
fruRevisionName2000.0010.0001.0009 This attribute defines the revision of the field replaceable unit.ro OCTET STRING .1.3.6.1.4.1.674.10892.5.4.2000.10.1.9 |
fruFQDD2000.0010.0001.0012 Fully qualified device descriptor (FQDD) of the field replaceable unit.ro FQDDString .1.3.6.1.4.1.674.10892.5.4.2000.10.1.12 |
storageDetailsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.5 |
software OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.5.1 |
storageManagement OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.5.1.20 |
physicalDevices OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.5.1.20.130 |
controllerTableA table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF ControllerTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.1 |
controllerTableEntryAn entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table. ControllerTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1 |
controllerNumberInstance number of this controller entry.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 |
controllerNameThe controller's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2 |
controllerRebuildRateThe rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 |
controllerFWVersionThe controller's current firmware version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 |
controllerCacheSizeInMBThe controller's current amount of cache memory in megabytes.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9 |
controllerRollUpStatusSeverity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critical 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 |
controllerComponentStatusThe status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverablero ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 |
controllerDriverVersionCurrently installed driver version for this controller on the host.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 |
controllerPCISlotThe PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers,ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 |
controllerReconstructRateThe reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID level of a virtual disk residing on the disk group.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48 |
controllerPatrolReadRateThe patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49 |
controllerBGIRateThe background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50 |
controllerCheckConsistencyRateThe check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.51 |
controllerPatrolReadModeIdentifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this controller. 3: Disabled. 4: Automatic. 5: Manual.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52 |
controllerPatrolReadStateThis property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is not running. 3: Patrol read is running.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53 |
controllerPersistentHotSpareIndicates whether hot spare drives would be restored on insertion into the same slot.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59 |
controllerSpinDownUnconfiguredDrivesIndicates whether un-configured drives would be put in power save mode by the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 |
controllerSpinDownHotSpareDrivesIndicates whether hot spare drives would be put in power save mode by the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61 |
controllerSpinDownTimeIntervalThe duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62 |
controllerPreservedCacheIndicates whether preserved cache or pinned cache is present on the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69 |
controllerCheckConsistencyModeThe current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal check consistency operation. 4: Check consistency operation will stop on encountering an error.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70 |
controllerCopyBackModeThe current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as spares could revert back to spare status. 4: Data from physical disk participating in a virtual disk could be automatically copied to the assigned hot spare in case former has a predictive failure event. 5: Copyback mode is disabled.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 |
controllerSecurityStatusThe controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encryption mode. 3: Controller is operating in the Local Key Management (LKM) encryption mode.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72 |
controllerEncryptionKeyPresentIndicates whether encryption key is assigned for the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.73 |
controllerEncryptionCapabilityThe type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management,ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74 |
controllerLoadBalanceSettingThe ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possible values: 1: Not one of the following. 2: Not supported. 3: Automatic load balancing is active. 4: Load balancing is inactive.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75 |
controllerMaxCapSpeedThe maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbpsro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 |
controllerSASAddressThe SAS address of the controller.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.77 |
controllerFQDDThe controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78 |
controllerDisplayNameThe controller's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 |
controllerT10PICapabilityIndicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 |
controllerRAID10UnevenSpansSupportedIndicates whether uneven spans for RAID 10 virtual disk is supported on the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81 |
controllerEnhancedAutoImportForeignConfigModeIndicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4: Enabled.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82 |
controllerBootModeSupportedIndicates whether headless boot mode settings are supported on the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83 |
controllerBootModeIndicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3: Continue Boot On Error. User interaction only required for critical messages. 4: Headless Mode Continue On Error. User interaction is not required. Controller boot may halt on Error. 5: Headless Safe Mode. Controller shall boot to safe mode on critical errors.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84 |
enclosureTableA table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enclosure(s) attached to the system.. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF EnclosureTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.3 |
enclosureTableEntryAn entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. EnclosureTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1 |
enclosureNumberInstance number of this enclossre/backplane.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.1 |
enclosureNameThe enclosure/backplane's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 |
enclosureStateThe current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The enclosure has encountered a hardware problem or is not responding. 4: The enclosure is no longer connected to the controller or there exists a problem communicating to the enclosure. 5: The enclosure is unstable.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 |
enclosureServiceTagEnclosure identification used when consulting customer support.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8 |
enclosureAssetTagThe asset tag information for the enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 |
enclosureConnectedPortThe port on the controller to which the storage enclosure is connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19 |
enclosureRollUpStatusSeverity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical. 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 |
enclosureComponentStatusThe status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.24 |
enclosureFirmwareVersionThe firmware information for the enclosure/backplane.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.26 |
enclosureSASAddressThe SAS address of the enclosure/backplane.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30 |
enclosureDriveCountThe number of disks present in the enclosure/backplane.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 |
enclosureTotalSlotsThe total physical drive slots in a storage enclosure or server backplane.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32 |
enclosureFanCountThe number of fans present in the storage enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40 |
enclosurePSUCountThe number of Power Supply Units (PSU) present in the storage enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 |
enclosureEMMCountThe number of Enclosure Management Modules (EMM) present in the storage enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 |
enclosureTempProbeCountThe number of temperature sensing devices present in the storage enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43 |
enclosureRedundantPathIndicates whether the controller has multiply paths to reach the storage enclosure.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44 |
enclosurePositionThe possition of the storage enclosure within a daisy chain.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45 |
enclosureBackplaneBayIDThe unique bay ID of the backplane.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46 |
enclosureFQDDThe enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47 |
enclosureDisplayNameThe enclosure/backplane's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 |
enclosureTypeThe protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backplane). 3: Supports SAS/SATA. 4: Supports PCIe. 5: Both SAS/SATA and PCIe.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49 |
physicalDiskTableA table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF PhysicalDiskTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.4 |
physicalDiskTableEntryAn entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. PhysicalDiskTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1 |
physicalDiskNumberInstance number of this physical disk entry.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 |
physicalDiskNameThe physical disk's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 |
physicalDiskManufacturerThe name of the physical disk's manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 |
physicalDiskStateThe current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID configuration has been assigned. 3: A RAID configuration has been assigned to the physical disk. 4: The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: The physical disk is not available to the RAID controller. 6: The physical disk is currently blocked by controller. 7: The physical disk is not operational. 8: The physical disk is not a RAID capable disk 9: The physical disk has been removed. 10:The physical disk media has been placed in read only mode.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 |
physicalDiskProductIDThe model number of the physical disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 |
physicalDiskSerialNoThe physical disk's unique identification number from the manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 |
physicalDiskRevisionThe firmware version of the physical disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 |
physicalDiskCapacityInMBThe size of the physical disk in megabytes.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 |
physicalDiskUsedSpaceInMBThe amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 |
physicalDiskFreeSpaceInMBThe amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19 |
physicalDiskBusTypeThe bus type of the physical disk. Possible values: 1: The bus type could not be determined. 2: Small Computer System Interface (SCSI). 3: Serial Attached SCSI (SAS). 4: Serial Advanced Technology Attachment (SATA). 5: Fibre channel. 6: PCIe.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21 |
physicalDiskSpareStateThe status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global hot spare.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 |
physicalDiskComponentStatusThe status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverablero ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 |
physicalDiskPartNumberThe part number of the disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27 |
physicalDiskSASAddressThe SAS address of the physical disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 |
physicalDiskNegotiatedSpeedThe data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices).ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29 |
physicalDiskCapableSpeedThe maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices).ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.30 |
physicalDiskSmartAlertIndicationIndicates whether the physical disk has received a predictive failure alert.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 |
physicalDiskManufactureDayThe day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 |
physicalDiskManufactureWeekThe week (1 thru 53) in which the physical disk was manufactured.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33 |
physicalDiskManufactureYearThe four digit year in which the physical disk was manufactured.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34 |
physicalDiskMediaTypeThe media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD).ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35 |
physicalDiskPowerStateThe power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in the spun down state. 4: The physical disk is changing from spun down state to spun up state or vice versa. 5: The Solid State Device (SSD) is powered on.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42 |
physicalDiskRemainingRatedWriteEnduranceThis property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if the value is not available or not applicable (in the case of HDD media type) the value will be 255.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 |
physicalDiskOperationalStateThe state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundant virtual disk is currently being rebuilt onto the physical disk. 3: Data on the disk is being erased. 4: Data is being copied from a hot spare disk to the physical disk or vice versa.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.50 |
physicalDiskProgressThe progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoingro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.51 |
physicalDiskSecurityStatusThe security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryption 3: The physical disk is encrypted. 4: The physical disk is locked by a key. 5: The physical disk is locked by a foreign key.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 |
physicalDiskFormFactorThe form factor of the physical disk. Possible values: 1: The form factor could not be determined. 2: 1.8 inch. 3: 2.5 inch. 4: 3.5 inch.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 |
physicalDiskFQDDThe physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 |
physicalDiskDisplayNameThe physical disk's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 |
physicalDiskT10PICapabilityIndicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.57 |
physicalDiskBlockSizeInBytesThe block size (in bytes) of the physical disk. This is not applicable for NVMe devices. 1: 512. 2: 4096ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58 |
physicalDiskProtocolVersionApplicable for NVMe devices only. The NVMe protocol version supported by the device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 |
physicalDiskPCIeNegotiatedLinkWidthApplicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.60 |
physicalDiskPCIeCapableLinkWidthApplicable for NVMe devices only. The PCIe link widths the device is capable of supporting.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.61 |
enclosureFanTableA table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF EnclosureFanTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.7 |
enclosureFanTableEntryAn entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. EnclosureFanTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1 |
enclosureFanNumberInstance number of this fan.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.1 |
enclosureFanNameThe fan's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2 |
enclosureFanStateThe current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a hardware problem or is not responding. 4: The fan is no longer connected to the enclosure or there exists a problem communicating to it. 5: The fan is unstable.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4 |
enclosureFanSpeedIndicates the current relative speed of the fan.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 |
enclosureFanComponentStatusThe status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 |
enclosureFanFQDDThe fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20 |
enclosureFanDisplayNameThe fan's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21 |
enclosurePowerSupplyTableA table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF EnclosurePowerSupplyTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.9 |
enclosurePowerSupplyTableEntryAn entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. EnclosurePowerSupplyTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1 |
enclosurePowerSupplyNumberInstance number of this power supply unit.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 |
enclosurePowerSupplyNameThe power supply unit's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 |
enclosurePowerSupplyStateThe current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: The power supply unit has encountered a hardware problem or is not responding. 4: The power supply unit is no longer connected to the enclosure or there exists a problem communicating to it. 5: The power supply unit is unstable.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 |
enclosurePowerSupplyPartNumberThe part number of the power supply unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7 |
enclosurePowerSupplyComponentStatusThe status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9 |
enclosurePowerSupplyFQDDThe power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 |
enclosurePowerSupplyDisplayNameThe power supply unit's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16 |
enclosureTemperatureProbeTableA table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF EnclosureTemperatureProbeTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.11 |
enclosureTemperatureProbeTableEntryAn entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. EnclosureTemperatureProbeTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1 |
enclosureTemperatureProbeNumberInstance number of this temperature probe.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1 |
enclosureTemperatureProbeNameThe temperature probe's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2 |
enclosureTemperatureProbeStateThe current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: The temperature probe has encountered a hardware problem or is not responding. 4: The temperature probe is no longer connected to the enclosure or there exists a problem communicating to it. 5: The temperature probe is unstable.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 |
enclosureTemperatureProbeMinWarningValueThe minimum temperature that will force the probe into a warning state.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7 |
enclosureTemperatureProbeMinCriticalValueThe minimum temperature that will force the probe into a error state.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 |
enclosureTemperatureProbeMaxWarningValueThe maximum temperature that will force the probe into a warning state.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9 |
enclosureTemperatureProbeMaxCriticalValueThe maximum temperature that will force the probe into a warning state.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 |
enclosureTemperatureProbeCurValueThe maximum temperature that will force the probe into a warning state.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11 |
enclosureTemperatureProbeComponentStatusThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.13 |
enclosureTemperatureProbeFQDDThe temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 |
enclosureTemperatureProbeDisplayNameThe temperature probe's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.16 |
enclosureManagementModuleTableA table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management modules discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF EnclosureManagementModuleTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.13 |
enclosureManagementModuleTableEntryAn entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. EnclosureManagementModuleTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1 |
enclosureManagementModuleNumberInstance number of this enclosure management module.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 |
enclosureManagementModuleNameThe enclosure management module's name as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2 |
enclosureManagementModuleStateThe current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is operating normally. 3: The enclosure management module has encountered a hardware problem or is not responding. 4: The enclosure management module is no longer connected to the enclosure or there exists a problem communicating to it. 5: The enclosure management module is unstable.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 |
enclosureManagementModulePartNumberThe part number of the enclosure management module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 |
enclosureManagementModuleFWVersionFirmware version of the enclosure management module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8 |
enclosureManagementModuleComponentStatusThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 |
enclosureManagementModuleFQDDThe enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.15 |
enclosureManagementModuleDisplayNameThe enclosure management module's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 |
batteryTableA table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF BatteryTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.15 |
batteryTableEntryAn entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. BatteryTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1 |
batteryNumberInstance number of this battery entry.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 |
batteryStateCurrent state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 |
batteryComponentStatusThe status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverablero ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.6 |
batteryPredictedCapacityThis entry is obsolete. Use the batteryComponentStatus or batteryState instead.roobsolete Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 |
batteryFQDDThe battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 |
batteryDisplayNameThe battery's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 |
logicalDevices OBJECT IDENTIFIER .1.3.6.1.4.1.674.10892.5.5.1.20.140 |
virtualDiskTableA table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. SEQUENCE OF VirtualDiskTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.140.1 |
virtualDiskTableEntryAn entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. VirtualDiskTableEntry .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1 |
virtualDiskNumberInstance number of this virtual disk entry.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 |
virtualDiskNameThe virtual disk's label as entered by the user.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 |
virtualDiskStateThe current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4 |
virtualDiskSizeInMBThe size of the virtual disk in megabytes.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6 |
virtualDiskWritePolicyThe write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10 |
virtualDiskReadPolicyThe read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11 |
virtualDiskLayoutThe virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13 |
virtualDiskStripeSizeThe stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32 kB, 10: 64 kB, 11: 128 kB, 12: 256 kB, 13: 512 kB, 14: 1 MB, 15: 2 MB, 16: 4 MB, 17: 8 MB, 18: 16 MBro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14 |
virtualDiskComponentStatusThe status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable.ro ObjectStatusEnum .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 |
virtualDiskBadBlocksDetectedIndicates whether the virtual disk has bad blocks.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23 |
virtualDiskSecuredIndicates whether the virtual disk is secured or not.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.24 |
virtualDiskIsCacheCadeIndicates whether the virtual disk is being used as a secondary cache by the controller.ro BooleanType .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 |
virtualDiskDiskCachePolicyThe cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26 |
virtualDiskOperationalStateThe state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 |
virtualDiskProgressThe progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoingro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.31 |
virtualDiskAvailableProtocolsList of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32 |
virtualDiskMediaTypeList of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33 |
virtualDiskRemainingRedundancyThe number of physical disks which can be lost before the virtual disk loses its redundancy.ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34 |
virtualDiskFQDDThe virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.ro FQDDString .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 |
virtualDiskDisplayNameThe virtual disk's friendly FQDD as represented in Storage Management.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36 |
virtualDiskT10PIStatusIndicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Enabled. 3: Disabled.ro Enumeration .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37 |
virtualDiskBlockSizeInBytesThe block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096ro INTEGER .1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.38 |