DNOS-BOXSERVICES-PRIVATE-MIB
AI MIB Summary
The DNOS-BOXSERVICES-PRIVATE-MIB provides vendor-specific monitoring for Broadcom-based devices running Dell Networking OS (DNOS), exposing internal metrics and status indicators for the underlying box services feature set. This private module enables granular visibility into proprietary hardware subsystems and service processes not covered by standard SNMP MIBs, facilitating deep-dive troubleshooting of internal service states and resource utilization.
The Broadcom Private MIB for DNOS Box Services Feature.
Main OID:
fastPathBoxServices.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43
57
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
57 total| Object Name |
|---|
fastPathBoxServicesThe Broadcom Private MIB for DNOS Box Services Feature. MODULE-IDENTITY .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43 |
fastPathBoxServicesTraps OBJECT IDENTIFIER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0 |
boxsFanStateChangeTrap is sent when fan state change happens. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.1 |
boxsPowSupplyStateChangeTrap is sent when power supply state change happens. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.2 |
boxsTemperatureChangeTrap is sent when temperature is changing and crossing any of the thresholds NOTIFICATION-TYPE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.3 |
boxsThermalShutdownTrap is sent when thermal shutdown is initiated. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.4 |
boxsTemperatureStateChangeTrap is sent when the system temperature crosses a threshold.
To avoid rapid flapping between states, a hysteresis may
be applied. NOTIFICATION-TYPE .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.5 |
boxServicesGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1 |
boxServicesNormalTempRangeMinLower boundary of normal temperature range.rw Integer32 (-100..100) .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.1 |
boxServicesNormalTempRangeMaxUpper boundary of normal temperature range.rw Integer32 (-100..100) .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.2 |
boxServicesTemperatureTrapEnableEnable or disable temperature change event trap, raised when temperature crosses boundaries of normal rangerw Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.3 |
boxServicesPSMStateTrapEnableEnable or disable Power Supply Module state change trap.rw Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.4 |
boxServicesFanStateTrapEnableEnable or disable Fan state change trap.rw Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.5 |
boxServicesFansTableFan SEQUENCE OF BoxServicesFansEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6 |
boxServicesFansEntryBox Services Fan Entry BoxServicesFansEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1 |
boxServicesFansIndexUnique index of fan table entryro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.1 |
boxServicesFanItemTypeThe type of fanro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.2 |
boxServicesFanItemStateThe status of fan. nopower(4) - This state means the fan is present but no AC is connected.ro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.3 |
boxServicesFanSpeedThe speed of fanro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.4 |
boxServicesFanDutyLevelThe duty level of fan, in percentsro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.5 |
boxServicesPowSuppliesTablePower supply SEQUENCE OF BoxServicesPowSuppliesEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7 |
boxServicesPowSuppliesEntryBox Services Power Supply Entry BoxServicesPowSuppliesEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1 |
boxServicesPowSupplyIndexUnique index of power supply table entryro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.1 |
boxServicesPowSupplyItemTypeThe type of power supplyro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.2 |
boxServicesPowSupplyItemStateThe status of power supply. nopower(4) - This state means the power supply is present but no AC is connected.
incompatible(5) - This state is possible on boards capable of pluggable Power suppliesro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.3 |
boxServicesTempSensorsTableTemperature sensor SEQUENCE OF BoxServicesTempSensorsEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8 |
boxServicesTempSensorsEntryBox Services Temperature Sensor Entry BoxServicesTempSensorsEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1 |
boxServicesUnitIndexUnit index for an entry in the Box Services Temperature Sensor Tablero Unsigned32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.1 |
boxServicesTempSensorIndexUnique index of temperature sensor table entryro Unsigned32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.2 |
boxServicesTempSensorTypeThe type of temperature sensorro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.3 |
boxServicesTempSensorStateThe state of temperature sensorroobsolete Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.4 |
boxServicesTempSensorTemperatureThe temperature value reported by sensorro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5 |
boxsUnitPwrUsageHistoryTableA table providing configuration and status of Power Usage History feature SEQUENCE OF BoxsUnitPwrUsageHistoryEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9 |
boxsUnitPwrUsageHistoryEntryPower Usage History Table for a Unit. BoxsUnitPwrUsageHistoryEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1 |
boxsPwrUsageHistoryUnitIndexThis is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
A non-zero value indicates the unitIndex for the corresponding unit
entry in the Power Usage History Table. INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1 |
boxsPwrUsageHistoryUnitSampleIndexThis is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
A non-zero value indicates the sampleIndex for the corresponding sample
entry in the Power Usage History Table. INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2 |
boxsPwrUsageHistoryUnitSampleTimeTime at which the Sample was collected.ro DisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3 |
boxsPwrUsageHistoryUnitPowerConsumptionPower Consumption (mWatts) at the time of collecting the given sample.ro INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4 |
boxsPwrUsageHistoryStackPowerConsumptionPower Consumption (mWatts) per Stack at the time of collecting the given sample.ro INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5 |
boxsPwrUsageHistoryUnitSampleIntervalInterval at which power consumption data needs to be collected.rw INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.10 |
boxsPwrUsageHistoryUnitMaxSamplesMaximum number of samples to keep.rw INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.11 |
boxServicesThermalShutdownSensorThe number of the sensor which initiated thermal shutdown.ro Unsigned32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.13 |
boxServicesThermalShutdownTemperatureThe temperature of the sensor which initiated thermal shutdown.ro Unsigned32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.14 |
boxServicesTempUnitTableTemperature status table SEQUENCE OF BoxServicesTempUnitEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15 |
boxServicesTempUnitEntryBox Services Temperature Unit Entry BoxServicesTempUnitEntry .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1 |
boxServicesTempUnitIndexUnit index for an entry in the Box Services Temperature Unit Table Unsigned32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.1 |
boxServicesTempUnitStateThe temperature state of the unitro BoxsTemperatureStatus .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.2 |
boxServicesTempUnitTemperatureThe highest temperature currently reported by any sensor on the unitro Integer32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.3 |
boxServicesNotificationsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2 |
boxsItemStateChangeEventThis event describes states of the fan or power supply.
insertion - hot-pluggable fan or power supply was inserted
removal - hot-pluggable fan or power supply was removed
becomeoperational - fan or power supply became operational after failure state
failure - fan or power supply failure happened, i.e. it is not able to perform its functions
losepower - a power supply was operational, but the power to it has been disconnected or has failedro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.1 |
boxsTemperatureChangeEventThis event describes change of the temperature.
To avoid flipping on boundary conditions, it is allowed to send the trap
taking into account some margin around thresholds.
abovethreshold - temperature increased and crossed upper threshold value
belowthreshold - temperature decreased and crossed lower threshold value
withinnormalrange - temperature returned to normal range (between threshold)ro Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.2 |
boxsTemperatureStatusCurrentEventThis event describes the current status of a switch.ro BoxsTemperatureStatus .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.3 |
boxsTemperatureStatusPreviousEventThis event describes the previous status of a switch.ro BoxsTemperatureStatus .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.4 |
boxsLocatorLedConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4 |
boxsLocatorLedUnitSpesifies unit number where Locator LED should blink on.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported.rw INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.1 |
boxsLocatorLedTimeIndicates time period in seconds for Locator LED blinking.
The range is from 20 to 3600 seconds.
The dafault value is 20 seconds.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported.rw INTEGER .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.2 |
boxsLocatorLedEnableStarts the Locator LED blinking.
If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported.rw Enumeration .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.3 |