Home/Catalog/DELLRAC-MIB

DELLRAC-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for DELLRAC-MIB.

51
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

51 total
Object Name
dell
OBJECT IDENTIFIER
.1.3.6.1.4.1.674
server3
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892
drsOutofBandGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2
alertDrscTestTrapEventThe RAC generated a test trap event in response to a user request.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1001
alertDrscAuthErrorThe RAC Authentication Failures during a time period have Exceeded a Threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1002
alertDrscLostESMThe RAC cannot communicate with the baseboard management controller (ESM).
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1003
alertDrscFoundESMThe RAC is communicating normally with the baseboard management controller (ESM).
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1004
alertDrscPowerOffThe RAC has detected a System power state change to powered-off.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1005
alertDrscPowerOnThe RAC has detected a system power state change to powered-on.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1006
alertDrscWatchdogExpiredThe RAC has detected that the system watchdog has expired indicating a system hang.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1007
alertDrscBattLowThe RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1008
alertDrscTempNormalThe RAC Temperature probe has retured to a normal value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1009
alertDrscTempWarningThe RAC Temperature probe has detected a Warning value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1010
alertDrscTempCriticalThe RAC Temperature probe has detected a failure (or critical) value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1011
alertDrscVoltNormalThe RAC voltage has returned to a normal value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1012
alertDrscVoltWarningThe RAC voltage probe has detected a warning value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1013
alertDrscVoltCriticalThe RAC voltage probe has detected a failure (or critical) value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1014
alertDrscSELWarningThe RAC has detected a new event in the System Event Log with Severity: Warning.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1015
alertDrscSELCriticalThe RAC has detected a new event in the System Event Log with Severity: Critical.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1016
alertDrscSEL80percentFullThe RAC has detected that the System Event Log is 80% full.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1017
alertDrscSEL90percentFullThe RAC has detected that the System Event Log is 90% full.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1018
alertDrscSEL100percentFullThe RAC has detected that the System Event Log is 100% full.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1019
alertDrscSELNormalThe RAC has detected a new event in the System Event Log with Severity: Normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.674.10892.2.0.1020
drsInformationGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.1
drsProductInfoGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.1.1
drsProductName0001.0001.0001 This attribute defines the product name of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.1
drsProductShortName0001.0001.0002 This attribute defines the short product name of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.2
drsProductDescription0001.0001.0003 This attribute defines the product description of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.3
drsProductManufacturer0001.0001.0004 This attribute defines the product manufacturer of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.4
drsProductVersion0001.0001.0005 This attribute defines the product version of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.5
drsChassisServiceTag0001.0001.0006 This attribute defines the service tag of the DELL chassis.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.6
drsProductURL0001.0001.0007 This attribute defines the out-of-band UI URL of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.7
drsProductChassisAssetTag0001.0001.0008 This attribute defines the Asset Tag of the DELL chassis.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.8
drsProductChassisLocation0001.0001.0009 This attribute defines the location of the DELL chassis.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.9
drsProductChassisName0001.0001.0010 This attribute defines the name of the DELL chassis.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.10
drsSystemServiceTag0001.0001.0011 This attribute defines the service tag of a DELL system.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.11
drsProductSystemAssetTag0001.0001.0012 This attribute defines the asset tag of a DELL system.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.12
drsProductSystemSlot0001.0001.0013 This attribute defines the slot number of a DELL system.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.1.13
drsProductType0001.0001.0014 This attribute defines the type of a remote access card.ro
DellRacType
.1.3.6.1.4.1.674.10892.2.1.1.14
drsFirmwareGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.1.2
drsFirmwareVersion0001.0002.0001 This attribute defines the firmware version of a remote access card.ro
DellString
.1.3.6.1.4.1.674.10892.2.1.2.1
drsStatusGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.2
drsGlobalSystemStatus0002.0001 This attribute defines the overall DELL chassis status being monitored by the remote access card.ro
DellStatus
.1.3.6.1.4.1.674.10892.2.2.1
drsAlertGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.5000
drsAlertVariables
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.5000.10
drsAlertSystem5000.0010.0001 Name of the system generating the alert.ro
OCTET STRING
.1.3.6.1.4.1.674.10892.2.5000.10.1
drsAlertTableIndexOID5000.0010.0002 0.0ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10892.2.5000.10.2
drsAlertMessage5000.0010.0003 Message describing the alert.ro
OCTET STRING
.1.3.6.1.4.1.674.10892.2.5000.10.3
drsAlertCurrentStatus5000.0010.0004 Current status of object causing the alert.ro
DellStatus
.1.3.6.1.4.1.674.10892.2.5000.10.4
drsAlertPreviousStatus5000.0010.0005 Previous status of object causing the alert.ro
DellStatus
.1.3.6.1.4.1.674.10892.2.5000.10.5
drsAlertData5000.0010.0006 Alert data.ro
OCTET STRING
.1.3.6.1.4.1.674.10892.2.5000.10.6