Home/Catalog/DELL-STORAGE-SC-MIB

DELL-STORAGE-SC-MIB

AI MIB Summary

The DELL-STORAGE-SC-MIB facilitates SNMP-based monitoring of Dell Storage Center hardware, exposing critical performance and status metrics including array health, disk drive states, controller redundancy, and port statistics. This module enables centralized management of storage subsystems by providing standardized access to operational data such as temperature, fan speeds, and I/O throughput counters for proactive infrastructure maintenance.

The MIB is for monitoring the status of Storage Center products from Dell Storage.
Main OID:
storageCenterModule.1.3.6.1.4.1.674.11000.2000.500.1.1
299
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

299 total
Object Name
dellEnterprise
OBJECT IDENTIFIER
.1.3.6.1.4.1.674
dellEnterpriseBranch
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.11000
dellStorageSubBranch
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.11000.2000
compellentEnterprise
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.11000.2000.500
storageCenter
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.11000.2000.500.1
storageCenterModule
MODULE-IDENTITY
.1.3.6.1.4.1.674.11000.2000.500.1.1
storageCenterObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.11000.2000.500.1.2
productIDDisplayNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.1
productIDDescriptionro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.2
productIDVendorro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.3
productIDVersionro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.4
productIDSerialNumberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.5
productIDGlobalStatusro
Enumeration
.1.3.6.1.4.1.674.11000.2000.500.1.2.6
productIDBuildNumberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.7
productIDURLro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.8
scAlertDefro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.9
scIndexro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.10
scTestStringro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.11
scMiscAlertStringro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.12
scCtlrTable
SEQUENCE OF ScCtlrEntry --points to def of ctlr entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.13
scCtlrEntry
ScCtlrEntry --is instance of controller entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1
scCtlrIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.1
scCtlrNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.2
scCtlrStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.3
scCtlrNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.4
scCtlrIpAddrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.5
scCtlrForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.6
scCtlrModelro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.7
scCtlrServiceTagro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.8
scCtlrAssetTagro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.9
scCtlrIPv6Eth0IPro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.10
scCtlrIPv6Eth0IPPrefixro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.11
scCtlrLeaderro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.12
scDiskTable
SEQUENCE OF ScDiskEntry --points to def of disk entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.14
scDiskEntry
ScDiskEntry --is instance of disk entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1
scDiskIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.1
scDiskNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.2
scDiskStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.3
scDiskNamePositionro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.4
scDiskHealthyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.5
scDiskStatusMsgro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.6
scDiskApiIndexro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.7
scDiskForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.8
scDiskSizero
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.9
scDiskIoPortTypero
Enumeration
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.10
scDiskEnclosurero
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.11
scEnclTable
SEQUENCE OF ScEnclEntry --points to def of enclosure entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.15
scEnclEntry
ScEnclEntry --is instance of enclosure entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1
scEnclIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.1
scEnclNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.2
scEnclStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.3
scEnclNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.4
scEnclStatusDescrro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.5
scEnclTypero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.6
scEnclModelro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.7
scEnclForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.8
scEnclServiceTagro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.9
scEnclAssetTagro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.10
scEnclApiIndexro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.11
scCtlrFanTable
SEQUENCE OF ScCtlrFanEntry
.1.3.6.1.4.1.674.11000.2000.500.1.2.16
scCtlrFanEntry
ScCtlrFanEntry --points to def of entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1
scCtlrFanIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.1
scCtlrFanNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.2
scCtlrFanStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.3
scCtlrFanNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.4
scCtlrFanCurrentRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.5
scCtlrFanNormMaxRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.6
scCtlrFanNormMinRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.7
scCtlrFanWarnLwrRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.8
scCtlrFanWarnUprRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.9
scCtlrFanCritLwrRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.10
scCtlrFanCritUprRpmro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.11
scCtlrFanForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.12
scCtlrFanApiIndexro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.13
scCtlrPowerTable
SEQUENCE OF ScCtlrPowerEntry
.1.3.6.1.4.1.674.11000.2000.500.1.2.17
scCtlrPowerEntry
ScCtlrPowerEntry --points to def of entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1
scCtlrPowerIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.1
scCtlrPowerNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.2
scCtlrPowerStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.3
scCtlrPowerNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.4
scCtlrPowerForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.5
scCtlrVoltageTable
SEQUENCE OF ScCtlrVoltageEntry
.1.3.6.1.4.1.674.11000.2000.500.1.2.18
scCtlrVoltageEntry
ScCtlrVoltageEntry --points to def of entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1
scCtlrVoltageIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.1
scCtlrVoltageNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.2
scCtlrVoltageStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.3
scCtlrVoltageNamero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.4
scCtlrVoltageCurrentVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.5
scCtlrVoltageNormMaxVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.6
scCtlrVoltageNormMinVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.7
scCtlrVoltageWarnLwrVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.8
scCtlrVoltageWarnUprVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.9
scCtlrVoltageCritLwrVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.10
scCtlrVoltageCritUprVro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.11
scCtlrVoltageForceTraprw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.12
scCtlrTempTable
SEQUENCE OF ScCtlrTempEntry
.1.3.6.1.4.1.674.11000.2000.500.1.2.19
scCtlrTempEntry
ScCtlrTempEntry --points to def of entry
.1.3.6.1.4.1.674.11000.2000.500.1.2.19.1
scCtlrTempIndex
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.1
scCtlrTempNbrro
Unsigned32
.1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.2
scCtlrTempStatusro
ScStatus
.1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.3
Showing 100 of 299 OID objects

DELL-STORAGE-SC-MIB Technical Reference Overview

The DELL-STORAGE-SC-MIB SNMP MIB module published by Dell defines 299 managed OID objects, including 219 scalar/column metrics, 22 SNMP tables, and 24 trap/notification events anchored at base OID .1.3.6.1.4.1.674.11000.2000.500.1.1. Key tabular structures include scAlertTable, scCacheTable, scCtlrFanTable, scCtlrPowerTable, scCtlrTable, scCtlrTempTable. Monitored SNMP traps/notifications include scCacheStatusChange, scCtlrCompStatusChange, scCtlrStatusChange, scDiskFolderStatusChange, scDiskStatusChange, scEnclCompStatusChange.

Key OID Definitions in DELL-STORAGE-SC-MIB

storageCenterModuleMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.1

The MIB is for monitoring the status of Storage Center products from Dell Storage.

scAlertTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.46

Alert Table

scCacheTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.28

Ctlr Cache Table

scCtlrFanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.16

Controller Fan Sensor Table

scCtlrPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.17

Controller Power Supply Table

scCtlrTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.13

Controller Table

scCtlrTempTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.19

Temperature Sensor Table

scCtlrVoltageTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.18

Voltage Sensor Table

scDiskConfigTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.45

Disk Configuration Table

scDiskFolderSUTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.32

Disk Folder Storage Usage Table

scDiskFolderTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.25

Disk Folder Table

scDiskTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.14

Disk Table

scEnclAlarmTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.24

Audible Alarm Table

scEnclFanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.20

enclosure Fan Sensor Table

scEnclIoModTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.22

I/O Module Table

scEnclPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.21

enclosure Power Supply Table

scEnclTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.15

Enclosure Table

scEnclTempTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.23

Temperature Sensor Table

scObjCntTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.31

Object Count Table

scScTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.29

Storage Center Table

scServerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.27

Server Table

scUPSTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.30

Monitored UPS Table

scVolumeTableSEQUENCEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.2.26

Volume Table

scCacheStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.210

Cache status change.

More MIBs from Dell