DELL-STORAGE-SC-MIB
The DELL-STORAGE-SC-MIB facilitates SNMP-based monitoring of Dell Storage Center hardware, exposing critical performance and status metrics including array health, disk drive states, controller redundancy, and port statistics. This module enables centralized management of storage subsystems by providing standardized access to operational data such as temperature, fan speeds, and I/O throughput counters for proactive infrastructure maintenance.
Imported Objects
Objects
299 total| Object Name |
|---|
dellEnterprise OBJECT IDENTIFIER .1.3.6.1.4.1.674 |
dellEnterpriseBranch OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000 |
dellStorageSubBranch OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000 |
compellentEnterprise OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.500 |
storageCenter OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.500.1 |
storageCenterModule MODULE-IDENTITY .1.3.6.1.4.1.674.11000.2000.500.1.1 |
storageCenterObjects OBJECT IDENTIFIER .1.3.6.1.4.1.674.11000.2000.500.1.2 |
productIDDisplayNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.1 |
productIDDescriptionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.2 |
productIDVendorro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.3 |
productIDVersionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.4 |
productIDSerialNumberro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.5 |
productIDGlobalStatusro Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.6 |
productIDBuildNumberro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.7 |
productIDURLro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.8 |
scAlertDefro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.9 |
scIndexro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.10 |
scTestStringro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.11 |
scMiscAlertStringro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.12 |
scCtlrTable SEQUENCE OF ScCtlrEntry --points to def of ctlr entry .1.3.6.1.4.1.674.11000.2000.500.1.2.13 |
scCtlrEntry ScCtlrEntry --is instance of controller entry .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1 |
scCtlrIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.1 |
scCtlrNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.2 |
scCtlrStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.3 |
scCtlrNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.4 |
scCtlrIpAddrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.5 |
scCtlrForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.6 |
scCtlrModelro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.7 |
scCtlrServiceTagro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.8 |
scCtlrAssetTagro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.9 |
scCtlrIPv6Eth0IPro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.10 |
scCtlrIPv6Eth0IPPrefixro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.11 |
scCtlrLeaderro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.12 |
scDiskTable SEQUENCE OF ScDiskEntry --points to def of disk entry .1.3.6.1.4.1.674.11000.2000.500.1.2.14 |
scDiskEntry ScDiskEntry --is instance of disk entry .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1 |
scDiskIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.1 |
scDiskNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.2 |
scDiskStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.3 |
scDiskNamePositionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.4 |
scDiskHealthyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.5 |
scDiskStatusMsgro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.6 |
scDiskApiIndexro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.7 |
scDiskForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.8 |
scDiskSizero Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.9 |
scDiskIoPortTypero Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.10 |
scDiskEnclosurero Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.11 |
scEnclTable SEQUENCE OF ScEnclEntry --points to def of enclosure entry .1.3.6.1.4.1.674.11000.2000.500.1.2.15 |
scEnclEntry ScEnclEntry --is instance of enclosure entry .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1 |
scEnclIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.1 |
scEnclNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.2 |
scEnclStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.3 |
scEnclNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.4 |
scEnclStatusDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.5 |
scEnclTypero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.6 |
scEnclModelro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.7 |
scEnclForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.8 |
scEnclServiceTagro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.9 |
scEnclAssetTagro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.10 |
scEnclApiIndexro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.11 |
scCtlrFanTable SEQUENCE OF ScCtlrFanEntry .1.3.6.1.4.1.674.11000.2000.500.1.2.16 |
scCtlrFanEntry ScCtlrFanEntry --points to def of entry .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1 |
scCtlrFanIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.1 |
scCtlrFanNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.2 |
scCtlrFanStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.3 |
scCtlrFanNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.4 |
scCtlrFanCurrentRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.5 |
scCtlrFanNormMaxRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.6 |
scCtlrFanNormMinRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.7 |
scCtlrFanWarnLwrRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.8 |
scCtlrFanWarnUprRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.9 |
scCtlrFanCritLwrRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.10 |
scCtlrFanCritUprRpmro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.11 |
scCtlrFanForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.12 |
scCtlrFanApiIndexro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.13 |
scCtlrPowerTable SEQUENCE OF ScCtlrPowerEntry .1.3.6.1.4.1.674.11000.2000.500.1.2.17 |
scCtlrPowerEntry ScCtlrPowerEntry --points to def of entry .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1 |
scCtlrPowerIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.1 |
scCtlrPowerNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.2 |
scCtlrPowerStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.3 |
scCtlrPowerNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.4 |
scCtlrPowerForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.5 |
scCtlrVoltageTable SEQUENCE OF ScCtlrVoltageEntry .1.3.6.1.4.1.674.11000.2000.500.1.2.18 |
scCtlrVoltageEntry ScCtlrVoltageEntry --points to def of entry .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1 |
scCtlrVoltageIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.1 |
scCtlrVoltageNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.2 |
scCtlrVoltageStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.3 |
scCtlrVoltageNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.4 |
scCtlrVoltageCurrentVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.5 |
scCtlrVoltageNormMaxVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.6 |
scCtlrVoltageNormMinVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.7 |
scCtlrVoltageWarnLwrVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.8 |
scCtlrVoltageWarnUprVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.9 |
scCtlrVoltageCritLwrVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.10 |
scCtlrVoltageCritUprVro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.11 |
scCtlrVoltageForceTraprw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.12 |
scCtlrTempTable SEQUENCE OF ScCtlrTempEntry .1.3.6.1.4.1.674.11000.2000.500.1.2.19 |
scCtlrTempEntry ScCtlrTempEntry --points to def of entry .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1 |
scCtlrTempIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.1 |
scCtlrTempNbrro Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.2 |
scCtlrTempStatusro ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.3 |
DELL-STORAGE-SC-MIB Technical Reference Overview
The DELL-STORAGE-SC-MIB SNMP MIB module published by Dell defines 299 managed OID objects, including 219 scalar/column metrics, 22 SNMP tables, and 24 trap/notification events anchored at base OID .1.3.6.1.4.1.674.11000.2000.500.1.1. Key tabular structures include scAlertTable, scCacheTable, scCtlrFanTable, scCtlrPowerTable, scCtlrTable, scCtlrTempTable. Monitored SNMP traps/notifications include scCacheStatusChange, scCtlrCompStatusChange, scCtlrStatusChange, scDiskFolderStatusChange, scDiskStatusChange, scEnclCompStatusChange.
Key OID Definitions in DELL-STORAGE-SC-MIB
.1.3.6.1.4.1.674.11000.2000.500.1.1The MIB is for monitoring the status of Storage Center products from Dell Storage.
.1.3.6.1.4.1.674.11000.2000.500.1.2.46Alert Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.28Ctlr Cache Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.16Controller Fan Sensor Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.17Controller Power Supply Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.13Controller Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.19Temperature Sensor Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.18Voltage Sensor Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.45Disk Configuration Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.32Disk Folder Storage Usage Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.25Disk Folder Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.14Disk Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.24Audible Alarm Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.20enclosure Fan Sensor Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.22I/O Module Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.21enclosure Power Supply Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.15Enclosure Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.23Temperature Sensor Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.31Object Count Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.29Storage Center Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.27Server Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.30Monitored UPS Table
.1.3.6.1.4.1.674.11000.2000.500.1.2.26Volume Table
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.210Cache status change.
More MIBs from Dell
Browse all DellMIBs →SNMP MIB module
SNMP MIB module
SNMP MIB module
The IDRAC-MIB-SMIv2 module enables SNMP-based out-of-band monitoring of Dell iDRAC hardware by exposing system telemetry metrics such as temperature, fan speed, power supply status, and memory utilization, while facilitating event notification through defined SNMP traps.
Standard SNMP MIB module defining data structures for IDRAC-MIB.
Standard SNMP MIB module defining data structures for ArrayManager-MIB.