Home/Catalog/DELL-SNMP-UPS-MIB

DELL-SNMP-UPS-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

180
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

180 total
Object Name
dell
OBJECT IDENTIFIER
.1.3.6.1.4.1.674
SNMPv2-TC
Unknown
.1.3.6.1.4.1.674
upsdell
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902
hardware
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2
productID
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.100
productIDDisplayNameName of this product for display purposes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.100.1
productIDDescriptionA short description of this product.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.2
productIDVendorThe name of the product manufacturer.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.3
productIDVersionThe version of this product.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.4
productIDBuildNumberThe software build number of the product populating the MIB.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.5
productIDURLThe URL of the web-based application to manage this device, should the device provide one.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.6
productIDDeviceNetworkNameOperating system specific computer name if product SNMP service is hosted.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.100.7
productStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.110
productStatusGlobalStatusCurrent status of the product. This is a rollup for the entire product including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.110.1
productStatusLastGlobalStatusThe status before the current status which induced an initiative to issue a global status change trap.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.110.2
productStatusTimeStampThe last time that the SNMP table geometries changed and/or attribute data was significantly updated. This is to be used by management applications to trigger a refresh of data acquired from the MIB.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.110.3
productStatusGetTimeOutSuggested time out value in milliseconds for how long the SNMP getter should wait while attempting to poll the product SNMP service.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.110.4
productStatusRefreshRateRate in seconds at which the SNMP service cached data is being updated.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.110.5
productStatusGeneratingTrapFlagIndicates if this SNMP sub-agent is capable of and/or is generating SNMP Traps. This variable can take the following values: 1 True, this service is capable of sending traps and is the originator of SNMP traps generated for the devices represented in this MIB and is currently generating traps. 2 False, this service not capable of sending traps and is not the originator of any SNMP traps generated for the devices represented in this MIB. 3 Disabled, this service is capable of sending traps and is the originator of SNMP traps for the devices represented in this MIB, but traps are currently disabled.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.110.6
physical
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120
physicalIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.1
physicalIdentFamilyNameUPS Family name.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.1.1
physicalIdentSerialNumberUPS Serial number.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.1.2
physicalIdentConverterTypeUPS type.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.1.3
physicalIdentReferenceNumberTechnical Reference of UPS firmware.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.1.4
physicalOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.2
physicalOutputInstantHeadroomThis is the present amount of watt capacity remaining before overload.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.1
physicalOutputPeakHeadroomStatistical value holding the lowest value that Instantaneous Headroom Watts was ever set too since the last time this statistic was reset.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.2
physicalOutputPeakHeadroomTimestampTime and date stamp of the last time the Peak Headroom Watts value was updated.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.120.2.3
physicalOutputPeakConsumptionStatistical value of the maximum RMS Watts the UPS has seen since the last time this statistic was reset.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.4
physicalOutputPeakConsumptionTimestampTime and date stamp of the last time the Peak Consumption Watts value was updated.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.120.2.5
physicalOutputPresentConsumptionDerived by averaging the watt second consumption over the past hour. Use an array of 60 words to store the average watt seconds consumed over the last minute then after you have a full hours worth of data in the 60 word array, average those values to get your Present KWH Consumption meter. Then every minute after that update the oldest value in the array, average again and update the meter. Value is 0 until the minimum 1 hour of data has been accumulated.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.6
physicalOutputCumulativeConsumption64 bit meter value that is derived by reading the Present KWH Consumption meter once per hour and adding it to the last value of this meter. Value accumulates until it is reset from the LCD or via the SHUT protocol or the meter rolls over.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.7
physicalOutputCumulativeConsumptionTimestampTime and date stamp of last time this meter value was reset.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.120.2.8
physicalOutputVAOutput VA.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.2.9
physicalRectifier
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.3
physicalRectifierPosVoltageDC bus positive voltage.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.3.1
physicalRectifierNegVoltageDC bus negative voltage.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.3.2
physicalUPS
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.4
physicalUPSDateTimeReal Time Clock with Date and Time.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.120.4.1
physicalUPSAlarmsStatusList of traps that are in active mode. This list is coded in ASCI format and each trap number is separated by a coma (ex: 1,5,23,77). Only odd traps are listed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.674.10902.2.120.4.2
physicalUPSRuntimeToShutdownNumber of seconds remaining until UPS will receive a ShutdownAfterDelay command. 2147483647 if no countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.4.3
physicalUPSOutpoutSwitchableParameter to enable or not remote UPS commands coming from all communication ports.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.4.4
physicalBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.5
physicalBatteryABMStatusAdvanced Battery Monitoring satus.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.5.1
physicalBatteryTestStatusBattery test satus.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.5.2
physicalBatterySecondsRemainingBattery remaining time calculated by the autonometer.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.5.3
physicalLoadSegment
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.6
physicalLoadSegment1ShutdownAfterDelayNumber of seconds remaining until load segment 1 will switch off. -1 if no shutdown countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.1
physicalLoadSegment1StartupAfterDelayNumber of seconds remaining until load segment 1 will switch on. -1 if no startup countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.2
physicalLoadSegment2ShutdownAfterDelayNumber of seconds remaining until load segment 2 will switch off. -1 if no shutdown countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.3
physicalLoadSegment2StartupAfterDelayNumber of seconds remaining until load segment 2 will switch on. -1 if no startup countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.4
physicalLoadSegment1RuntimeToShutdownNumber of seconds remaining until load segment 1 will receive a ShutdownAfterDelay command. 2147483647 if no countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.5
physicalLoadSegment2RuntimeToShutdownNumber of seconds remaining until load segment 2 will receive a ShutdownAfterDelay command. 2147483647 if no countdown is in effect.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.6.6
physicalEnvironment
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.7
physicalEnvironmentSensorPresentInformations, if there is Environment Measurement Probe connected.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.1
physicalEnvironmentSensorNameUser name of EMP.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.7.2
physicalEnvironmentValues
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.120.7.3
physicalEnvironmentValuesTemperatureUnitTemperature unit setting.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.7.3.1
physicalEnvironmentValuesTemperatureCurrent temperature value in 0.1 degree Celsius.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.2
physicalEnvironmentValuesHumidityCurrent humidity value in 0.1 percents.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.3
physicalEnvironmentValuesTemperatureLowTemperature low threshhold in units of degree Celsius.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.4
physicalEnvironmentValuesTemperatureHighTemperature high threshhold in units of degree Celsius.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.5
physicalEnvironmentValuesTemperatureHysteresisTemperature hysteresis in units of degree Celsius.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.6
physicalEnvironmentValueshHumidityLowHumidity low threshhold in percents.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.7
physicalEnvironmentValuesHumidityHighHumidity high threshhold in percents.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.8
physicalEnvironmentValuesHumidityHysteresisHumidity hysteresis in percents.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.3.9
physicalEnvironmentInputTableThe table containins dry contact inputs information.
SEQUENCE OF PhysicalEnvironmentInputEntry
.1.3.6.1.4.1.674.10902.2.120.7.4
physicalEnvironmentInputEntryThe description of an entry in the table.
PhysicalEnvironmentInputEntry
.1.3.6.1.4.1.674.10902.2.120.7.4.1
physicalEnvironmentInputIndexThe input index, ranging from 1 to 2.ro
INTEGER
.1.3.6.1.4.1.674.10902.2.120.7.4.1.1
physicalEnvironmentInputNameThe input user-friendly name.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.7.4.1.2
physicalEnvironmentInputStateCurrent state of input.ro
Enumeration
.1.3.6.1.4.1.674.10902.2.120.7.4.1.3
physicalEnvironmentInputOpenedStateThe input opened state user-friendly name.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.7.4.1.4
physicalEnvironmentInputClosedStateThe input closed state user-friendly name.ro
DisplayString
.1.3.6.1.4.1.674.10902.2.120.7.4.1.5
logical
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.130
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.674.10902.2.140
trapInverterOverVoltageInverter AC over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.1
trapInverterOverVoltageOkInverter AC over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.2
trapInverterUnderVoltageInverter AC under voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.3
trapInverterUnderVoltageOkInverter AC under voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.4
trapBypassFrequencyOutOfRangeBypass under or over frequency.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.5
trapBypassFrequencyOutOfRangeOkBypass under or over frequency ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.6
trapOnBuckOn Buck / Input Voltage Reducer.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.7
trapReturnFromBuckReturn from Buck.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.8
trapOnBoostOn Boost / Input Voltage Booster.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.9
trapReturnFromBoostReturn from Boost.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.10
trapInputOverVoltageInput AC over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.11
trapInputOverVoltageOkInput AC over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.12
trapInputUnderVoltageInput AC under voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.13
trapInputUnderVoltageOkInput AC under voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.14
trapInputFrequencyOutOfRangeInput under or over frequency.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.15
trapInputFrequencyOutOfRangeOkInput under or over frequency ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.16
trapRemoteEmergencyPowerOffRemote emergency power off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.17
trapReturnFromEmergencyPowerOffReturn from remote emergency power off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.18
trapLevel1OverloadOutput Level 1 overload.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.19
trapLevel1OverloadOkOutput Level 1 overload ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.20
trapLevel2OverloadLevel 2 overload.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.21
trapLevel2OverloadOkLevel 2 overload ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.22
trapLevel3OverloadLevel 3 overload.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.23
trapLevel3OverloadOkLevel 3 overload ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.24
trapPosDCLinkOverVoltagePositive DC link over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.25
trapPosDCLinkOverVoltageOkPositive DC link over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.26
trapPosDCLinkUnderVoltagePositive DC link under voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.27
trapPosDCLinkUnderVoltageOkPositive DC link under voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.28
trapNegDCLinkOverVoltageNegative DC link over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.29
trapNegDCLinkOverVoltageOkNegative DC link over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.30
trapNegDCLinkUnderVoltageNegative DC link under voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.31
trapNegDCLinkUnderVoltageOkNegative DC link under voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.32
trapRectifierFaultRectifier fault.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.33
trapRectifierOkRectifier ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.34
trapInverterFaultInverter fault.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.35
trapInverterOkInverter ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.36
trapChargerFailureCharger failure.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.37
trapChargerOkCharger ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.38
trapEepromFailureEEPROM failure.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.39
trapEepromOkEEPROM off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.40
trapShutdownImminentShutdown imminent.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.41
trapShutdownImminentOverShutdown imminent over.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.42
trapBatteryLowBattery low.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.43
trapBatteryOkBattery ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.44
trapOutputShortCircuitOutput short circuit.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.45
trapOutputReturnFromShortCircuitOutput return from short circuit.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.46
trapUtilityNotPresentUtility not present.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.47
trapUtilityPresentUtility present.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.48
trapBatteryOverVoltageBattery DC over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.49
trapBatteryOverVoltageOkBattery DC over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.50
trapHeatsinkOvertemperatureHeatsink overtemperature.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.51
trapHeatsinkOvertemperatureOkHeatsink overtemperature ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.52
trapBypassNotAvailableBypass not available.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.53
trapBypassNotAvailableOkBypass not available ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.54
trapOnManualBypassOn manual/ maintenance bypass.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.55
trapUPSOnBatteryUPS on battery.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.57
trapUPSReturnFromBatteryUPS return from battery.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.58
trapUPSOnBypassUPS on bypass.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.59
trapUPSReturnFromBypassUPS return from bypass.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.60
trapBatteryTestInProgressBattery manual or automatic test in progress.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.61
trapBatteryTestDoneBattery test done.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.62
trapBatteryNeedReplacementBattery test failed, battery needs to be replaced.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.63
trapBatteryReplacementDoneBattery replacement done.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.64
trapFanFailureFan failure.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.65
trapFanOkFan ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.66
trapSiteWiringFaultSite wiring fault.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.67
trapSiteWiringOkSite wiring ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.68
trapBatteryDisconnectedBatteries disconnected.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.69
trapBatteryConnectedBatteries connected.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.70
trapUPSOffUPS off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.71
trapUPSOnUPS on.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.72
trapDCLinkImbalanceDC link imbalance.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.73
trapDCLinkImbalanceOkDC link imbalance ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.74
trapABMOnABM state on.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.79
trapABMOffABM state off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.80
trapLoadSegment1OffLoad segment 1 off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.81
trapLoadSegment1OnLoad segment 1 on.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.82
trapLoadSegment2OffLoad segment 2 off.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.83
trapLoadSegment2OnLoad segment 2 on.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.84
trapInHighEfficiencyModeIn High Efficiency mode.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.85
trapReturnFromHighEfficiencyModeReturn from High Efficiency mode.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.86
trapRectifierOverloadRectifier input over current.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.87
trapRectifierOverloadOkRectifier current ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.88
trapInverterOverloadInverter output over current.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.89
trapInverterOverloadOkInverter output current ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.90
trapBypassVoltageOutOfRangeBypass AC under or over voltage.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.91
trapBypassVoltageOutOfRangeOkBypass AC under or over voltage ok.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.92
trapServiceBatteryService battery.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.93
trapToBypassCommandUPS received command to switch on bypass.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.94
trapFromBypassCommandUPS received command to switch on inverter.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.95
trapCommunicationLostLost communication with UPS, HID databasis is not updated.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.96
trapCommunicationRestoredCommunication restored with UPS, HID databasis is updated.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.97
trapEnvironComFailureEnvironment Probe communication failure.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.98
trapEnvironComOKEnvironment Probe communication restored.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.99
trapEnvironTemperatureLowTemperature is below low threshold.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.100
trapEnvironTemperatureHighTemperature is above high threshold.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.102
trapEnvironTemperatureOKTemperature is in normal range.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.103
trapEnvironHumidityLowHumidity is below low threshold.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.104
trapEnvironHumidityHighHumidity is above high threshold.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.106
trapEnvironHumidityOKHumidity is in normal range.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.107
trapEnvironInput1ClosedInput #1 is Closed.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.108
trapEnvironInput1OpenInput #1 is Open.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.109
trapEnvironInput2ClosedInput #2 is Closed.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.110
trapEnvironInput2OpenInput #2 is Open.
TRAP-TYPE
.1.3.6.1.4.1.674.10902.2.140.0.111
DELL-SNMP-UPS-MIB - SNMP MIB Reference | MIBs Explorer