CYCLADES-ACS-SYS-MIB
AI MIB Summary
The CYCLADES-ACS-SYS-MIB provides SNMP management access to system-level telemetry for Cyclades ACS/TS (Access Control Server/Terminal Server) hardware, specifically exposing operational status, configuration parameters, and resource utilization metrics for terminal server aggregation and remote access control functions.
This module defines the ACS/TS System Information
Main OID:
cyACSSys.1.3.6.1.4.1.2925.4.1
35
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
35 total| Object Name |
|---|
cyACSSysThis module defines the ACS/TS System Information MODULE-IDENTITY .1.3.6.1.4.1.2925.4.1 |
cyACSpnameThe product's name - ACSxx (xx - the number of the serial ports )ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.1 |
cyACSversionThe firmware's versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.2 |
cyACSPowerIt gives information about Power Supply OBJECT IDENTIFIER .1.3.6.1.4.1.2925.4.1.3 |
cyACSPwNumNumber of the power suppliesro Integer32 .1.3.6.1.4.1.2925.4.1.3.1 |
cyACSPw1State of the first power supplyro Enumeration .1.3.6.1.4.1.2925.4.1.3.2 |
cyACSPw2State of the second power supplyro Enumeration .1.3.6.1.4.1.2925.4.1.3.3 |
cyACSPcmciaPCMCIA card information OBJECT IDENTIFIER .1.3.6.1.4.1.2925.4.1.4 |
cyACSNPcmciaNumber of the cards PCMCIA availablero Integer32 .1.3.6.1.4.1.2925.4.1.4.1 |
cyCardIdentTableCard identification SEQUENCE OF CyCardIdentEntry .1.3.6.1.4.1.2925.4.1.4.2 |
cyCardIdentEntryOne particular association between PCMCIA socket and card identification CyCardIdentEntry .1.3.6.1.4.1.2925.4.1.4.2.1 |
cyCardIdentIndexnumber to identifier the socket Cardro Integer32 .1.3.6.1.4.1.2925.4.1.4.2.1.1 |
cyCardIdentProdProduct identification stringsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.2.1.2 |
cyCardIdentManManufacturer ID codesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.2.1.3 |
cyCardIdentFuncFunction ID codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.2.1.4 |
cyCardIdentPCIPCI IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.2.1.5 |
cyCardConfTableThis table has the socket configuration SEQUENCE OF CyCardConfEntry .1.3.6.1.4.1.2925.4.1.4.3 |
cyCardConfEntryOne particular association between PCMCIA socket and its configuration CyCardConfEntry .1.3.6.1.4.1.2925.4.1.4.3.1 |
cyCardConfIndexnumber to identifier the socket PCMCIAro Integer32 .1.3.6.1.4.1.2925.4.1.4.3.1.1 |
cyCardConfPowerPower Settingsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.2 |
cyCardConfTypeInterface Typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.3 |
cyCardConfInterInterrupt numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.4 |
cyCardConfFuncfunctionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.5 |
cyCardConfCardvCard valuesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.6 |
cyCardConfPort1I/O Port 1ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.7 |
cyCardConfPort2I/O Port 2ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.3.1.8 |
cyCardStatusTableThis table has the current socket status flags SEQUENCE OF CyCardStatusEntry .1.3.6.1.4.1.2925.4.1.4.4 |
cyCardStatusEntryOne particular association between PCMCIA socket and its status CyCardStatusEntry .1.3.6.1.4.1.2925.4.1.4.4.1 |
cyCardStatusIndexnumber to identifier the socket PCMCIAro Integer32 .1.3.6.1.4.1.2925.4.1.4.4.1.1 |
cyCardStatusCardCurrent Card Statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.4.1.2 |
cyCardStatusFuncCurrent Functionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.4.4.1.3 |
cyACSFlashSizeTotal amount of flash memory in Mbytesro Integer32 .1.3.6.1.4.1.2925.4.1.5 |
cyACSRAMSizeTotal amount of RAM in Mbytesro Integer32 .1.3.6.1.4.1.2925.4.1.6 |
cyACSCPUfreqCPU clock in MHzro Integer32 .1.3.6.1.4.1.2925.4.1.7 |
cyACSDevIdThe product's identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2925.4.1.8 |