Home/Catalog/CYCLADES-ACS-PM-MIB

CYCLADES-ACS-PM-MIB

AI MIB Summary

The CYCLADES-ACS-PM-MIB enables SNMP monitoring of Proxy for PM performance metrics and operational states on Cyclades ACS hardware. It facilitates the tracking of proxy session statistics, throughput counters, and resource utilization specific to the Proxy for PM service.

This module defines objects of the Proxy for PM
Main OID:
cyPM.1.3.6.1.4.1.2925.4.5
29
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

29 total
Object Name
cyPMThis module defines objects of the Proxy for PM
MODULE-IDENTITY
.1.3.6.1.4.1.2925.4.5
cyNumberOfPMThe total number of PM's connected on the unitro
Integer32
.1.3.6.1.4.1.2925.4.5.1
cyPMTableAllows to read information about each connected PM
SEQUENCE OF CyPMEntry
.1.3.6.1.4.1.2925.4.5.2
cyPMEntryInformation about the connected PM
CyPMEntry
.1.3.6.1.4.1.2925.4.5.2.1
cyPMSerialPortNumberThe number of the serial port when the PM is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.2925.4.5.2.1.1
cyPMNumberOutletsNumber of outlets.ro
Integer32
.1.3.6.1.4.1.2925.4.5.2.1.2
cyPMNumberUnitsTotal number of PM unists that are accessed by this serial port.ro
Integer32
.1.3.6.1.4.1.2925.4.5.2.1.3
cyPMCurrentCurrent reading for the PM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2925.4.5.2.1.4
cyPMVersionThe software version of the PM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2925.4.5.2.1.5
cyPMTemperatureThe PM temperature.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2925.4.5.2.1.6
cyPMCommandA character string for the user to send commands to PM. He can use it to does the save command. Or to list the outlets that need to be turned off, or turned on , or cycled or locked or unlocked as a group. The command is the first word and is followed by a space and the outlet list (otulets commands). Valid commands are 'on', 'off', 'cycle', 'lock', 'unlock', 'save'.rw
DisplayString
.1.3.6.1.4.1.2925.4.5.2.1.7
cyPMUnitTableAllow operations on specific PM unit connected
SEQUENCE OF CyPMUnitEntry
.1.3.6.1.4.1.2925.4.5.3
cyPMUnitEntryAllow operations on outlet
CyPMUnitEntry
.1.3.6.1.4.1.2925.4.5.3.1
cyPMUnitNumberThe number of the PM unit in the daisy-chained mode.
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.2925.4.5.3.1.1
cyPMUnitVersionThe software version of this PM unit.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2925.4.5.3.1.2
cyPMUnitOutletsNumber of outlets of this PM unit.ro
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.3
cyPMUnitFirstOutletNumber of the first outlet of this PM unit.ro
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.4
cyPMUnitCurrentCurrent of this PM unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)ro
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.5
cyPMUnitMaxCurrentMaximum current of this PM unit in AMP. The value of this object is the maximum current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the maximum current is 0.5 AMP.)ro
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.6
cyPMUnitTemperatureTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).ro
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.7
cyPMUnitMaxTemperatureMaximum temperature value of this PM unit in Celsius degrees. The value of this object is the maximum temperature in degrees C * 10. You need to translate the readed value(Ex. : value is 240, the maximum temperature is 24 Celsius). If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).rw
Integer32
.1.3.6.1.4.1.2925.4.5.3.1.8
cyOutletTableAllow operations on outlet
SEQUENCE OF CyOutletEntry
.1.3.6.1.4.1.2925.4.5.4
cyOutletEntryAllow operations on outlet
CyOutletEntry
.1.3.6.1.4.1.2925.4.5.4.1
cyOutletNumberThe outlet number on the PM. Zero is ALL outlets.
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.2925.4.5.4.1.1
cyOutletNameThe name given to a particular outlet Maximum size is 8 characters.rw
DisplayString
.1.3.6.1.4.1.2925.4.5.4.1.2
cyOutletServerAlias of the Server connected to this outlet .ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2925.4.5.4.1.3
cyOutletPowerGetting this object will return the power state of the outlet. Valid return states are UNKNOW, OFF and ON. Setting this object will change the power state of the outlet.rw
Enumeration
.1.3.6.1.4.1.2925.4.5.4.1.4
cyOutletLockGetting this object will return the lock state of the outlet. Setting this object will change the lock state of the outlet.rw
Enumeration
.1.3.6.1.4.1.2925.4.5.4.1.5
cyOutletPUIntervalThe power unit interval of this outlet in seconds. The value of this object is the actual interval in seconds * 10. You need to translate the readed value (Ex. : value is 5, the interval is 0.5 seconds.)rw
Integer32
.1.3.6.1.4.1.2925.4.5.4.1.6
CYCLADES-ACS-PM-MIB - SNMP MIB Reference | MIBs Explorer