CM-PROTECTION-MIB
Imported Objects
Objects
49 total| Object Name |
|---|
cmProtectionMIBThis module defines the Protection MIB definitions used by
the F3 (FSP150CM/CC) product lines.
Copyright (C) ADVA Optical Networking. MODULE-IDENTITY .1.3.6.1.4.1.2544.1.12.7 |
cmProtObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.7.1 |
cmFacProtGroupTableA list of entries corresponding to the Facility Protection Groups.
Entries can be created/deleted in this table by management
application action. SEQUENCE OF CmFacProtGroupEntry .1.3.6.1.4.1.2544.1.12.7.1.1 |
cmFacProtGroupEntryAn entry containing information applicable to a particular
Protection Group. CmFacProtGroupEntry .1.3.6.1.4.1.2544.1.12.7.1.1.1 |
cmFacProtGroupIndexUnique index value associated with the Facility Protection Group.ro Integer32 .1.3.6.1.4.1.2544.1.12.7.1.1.1.1 |
cmFacProtGroupUserLabelUser Label associated with the Facility Protection Group.rw DisplayString .1.3.6.1.4.1.2544.1.12.7.1.1.1.2 |
cmFacProtGroupSwitchModeFacility Protection Group's Protection Switch Mode.rw CmProtSwitchMode .1.3.6.1.4.1.2544.1.12.7.1.1.1.3 |
cmFacProtGroupRevertiveWhether the Facility Protection is revertive or not.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.4 |
cmFacProtGroupWaitToRestoreTime in minutes to wait before reverting to Working facility
in case of cmFacProtGroupRevertive set to revertive.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.rw Integer32 (1..60|0) .1.3.6.1.4.1.2544.1.12.7.1.1.1.5 |
cmFacProtGroupDirectionSupported Protection Group Switch direction.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.rw CmProtSwitchDirection .1.3.6.1.4.1.2544.1.12.7.1.1.1.6 |
cmFacProtGroupWorkPortFacility Protection Group exists between 2 facilities (ports).
This object represents the WORKING facility Port.rw VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.7 |
cmFacProtGroupProtPortThis object
represents the PROTECT facility Network Element Port when
cmFacProtGroupSwitchMode is oneplusone. In the case of
dualactiverx, this represents the second active port.rw VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.8 |
cmFacProtGroupStatusThis object represents the PROTECTION group status.ro CmProtGroupStatus .1.3.6.1.4.1.2544.1.12.7.1.1.1.9 |
cmFacProtGroupActionUser initiated protection switch action.rw CmProtSwitchAction .1.3.6.1.4.1.2544.1.12.7.1.1.1.10 |
cmFacProtGroupStorageTypeThe type of storage configured for this entry.rw StorageType (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.11 |
cmFacProtGroupRowStatusThe status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of cmFacProtGroupRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
cmFacProtGroupRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The cmFacProtGroupRowStatus object may be modified if
the associated instance of this object is equal to active(1).rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.12 |
cmFacProtGroupMacAddressThis object allows retrieval of the Mac Address of the PROTECTION group.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.1.1.13 |
cmFacProtUnitTableA list of entries corresponding to the Facility Protection
Units. SEQUENCE OF CmFacProtUnitEntry .1.3.6.1.4.1.2544.1.12.7.1.2 |
cmFacProtUnitEntryAn entry containing information applicable to a particular
Protection Unit. CmFacProtUnitEntry .1.3.6.1.4.1.2544.1.12.7.1.2.1 |
cmFacProtUnitIndexUnique index value associated with the Facility Protection Unit.ro Integer32 .1.3.6.1.4.1.2544.1.12.7.1.2.1.1 |
cmFacProtUnitTypeFacility Protection Unit's Type, i.e. whether working or protect.ro CmProtUnitType .1.3.6.1.4.1.2544.1.12.7.1.2.1.2 |
cmFacProtUnitStateFacility Protection Unit's State, i.e. whether active or standby.ro CmProtUnitState .1.3.6.1.4.1.2544.1.12.7.1.2.1.3 |
cmFacProtUnitPortFacility Protection Unit's points to a facility (port).
This object represents the facility Network Element port.ro VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.2.1.4 |
cmMSPGroupTableA list of entries corresponding to the Multiplex Section Protection Groups.
Entries can be created/deleted in this table by management
application action. SEQUENCE OF CmMSPGroupEntry .1.3.6.1.4.1.2544.1.12.7.1.3 |
cmMSPGroupEntryAn entry containing information applicable to a particular
Protection Group. CmMSPGroupEntry .1.3.6.1.4.1.2544.1.12.7.1.3.1 |
cmMSPGroupIndexUnique index value associated with the Multiplex Section Protection Group.ro Integer32 .1.3.6.1.4.1.2544.1.12.7.1.3.1.1 |
cmMSPGroupUserLabelUser Label associated with the Multiplex Section Protection Group.rw DisplayString .1.3.6.1.4.1.2544.1.12.7.1.3.1.2 |
cmMSPGroupSwitchModeMultiplex Section Protection Group's Protection Switch Mode.rw CmProtSwitchMode .1.3.6.1.4.1.2544.1.12.7.1.3.1.3 |
cmMSPGroupRevertiveWhether the Multiplex Section Protection is revertive or not.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.4 |
cmMSPGroupWaitToRestoreTime in minutes to wait before reverting to Working facility
in case of cmMSPGroupRevertive set to revertive.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.rw Integer32 (1..60|0) .1.3.6.1.4.1.2544.1.12.7.1.3.1.5 |
cmMSPGroupB2DEGTriggerB2DEG is trigger of MSP or not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.6 |
cmMSPGroupDirectionSupported Protection Group Switch direction.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.rw CmProtSwitchDirection .1.3.6.1.4.1.2544.1.12.7.1.3.1.7 |
cmMSPGroupWorkPortMultiplex Section Protection Group exists between 2 facilities (ports).
This object represents the WORKING facility Port.rw VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.8 |
cmMSPGroupProtPortThis object
represents the PROTECT facility Network Element Port when
cmMSPGroupSwitchMode is oneplusone. In the case of
dualactiverx, this represents the second active port.rw VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.9 |
cmMSPGroupStatusThis object represents the PROTECTION group status.ro CmProtGroupStatus .1.3.6.1.4.1.2544.1.12.7.1.3.1.10 |
cmMSPGroupActionUser initiated protection switch action.rw CmProtSwitchAction .1.3.6.1.4.1.2544.1.12.7.1.3.1.11 |
cmMSPGroupStorageTypeThe type of storage configured for this entry.rw StorageType (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.12 |
cmMSPGroupRowStatusThe status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of cmMSPGroupRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
cmMSPGroupRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The cmMSPGroupRowStatus object may be modified if
the associated instance of this object is equal to active(1).rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.13 |
cmMSPGroupMacAddressThis object allows retrieval of the Mac Address of the PROTECTION group.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.3.1.14 |
cmMSPUnitTableA list of entries corresponding to the Multiplex Section Protection
Units. SEQUENCE OF CmMSPUnitEntry .1.3.6.1.4.1.2544.1.12.7.1.4 |
cmMSPUnitEntryAn entry containing information applicable to a particular
Protection Unit. CmMSPUnitEntry .1.3.6.1.4.1.2544.1.12.7.1.4.1 |
cmMSPUnitIndexUnique index value associated with the Multiplex Section Protection Unit.ro Integer32 .1.3.6.1.4.1.2544.1.12.7.1.4.1.1 |
cmMSPUnitTypeMultiplex Section Protection Unit's Type, i.e. whether working or protect.ro CmProtUnitType .1.3.6.1.4.1.2544.1.12.7.1.4.1.2 |
cmMSPUnitStateMultiplex Section Protection Unit's State, i.e. whether active or standby.ro CmProtUnitState .1.3.6.1.4.1.2544.1.12.7.1.4.1.3 |
cmMSPUnitPortFacility Protection Unit's points to a facility (port).
This object represents the facility Network Element port.ro VariablePointer (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.7.1.4.1.4 |
cmProtNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.7.2 |
cmProtConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.7.3 |
cmProtCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.7.3.1 |
cmProtGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.7.3.2 |
More MIBs from ADVA AG Optical Networking
Browse all ADVA AG Optical NetworkingMIBs →SNMP MIB module
The ADVA-FSPR7-MIB module enables SNMP-based monitoring and management of ADVA FSP 7000 optical transport network elements, specifically tracking optical channel performance, signal quality metrics, and interface status. It facilitates the collection of critical telemetry data such as optical power levels, bit error rates, and alarm states for the ADVA FSPR7 series equipment.
The ADVA-FSPR7-PM-MIB enables SNMP-based performance monitoring of ADVA FSPR 7000 optical transport network equipment, specifically tracking traffic statistics, error counters, and signal quality metrics for SDH/SONET and OTN interfaces.
The CM-FACILITY-MIB module enables SNMP-based monitoring of facility-level environmental and power infrastructure metrics, such as temperature, humidity, and power supply status, specifically for ADVA Optical Networking's F3 (FSP150CM/CC) product lines.
The CM-PERFORMANCE-MIB enables ADVA Optical Networking FSP150CM/CC platforms to expose optical performance monitoring counters, including signal power, bit error rates, and latency metrics, via the Simple Network Management Protocol. These definitions facilitate the collection of physical layer statistics required for fault detection and service level agreement verification in F3 product line deployments.
SNMP MIB module