CIENA-WS-XCVR-PLUGGABLE-MIB
The CIENA-WS-XCVR-PLUGGABLE-MIB enables NETCONF-based management of Ciena WaveLogic pluggable optical transceiver modules, exposing operational state and diagnostic metrics such as optical power levels, temperature, bias current, and alarm thresholds. This module augments the base Ciena WaveLogic transceiver data model to provide granular visibility into the physical layer health and performance of pluggable optics deployed on Ciena switching and routing platforms.
Imported Objects
Objects
83 total| Object Name |
|---|
cienaWsXcvrPluggableMIBThis YANG module defines Ciena's XCVR common pluggable specific data for the NETCONF protocol. It will augment the ciena-ws-xcvr module. MODULE-IDENTITY .1.3.6.1.4.1.1271.3.4.17 |
cienaWsXcvrPluggableObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1271.3.4.17.1 |
cienaWsXcvrPluggableConformance OBJECT IDENTIFIER .1.3.6.1.4.1.1271.3.4.17.2 |
cienaWsXcvrPluggableGroups OBJECT IDENTIFIER .1.3.6.1.4.1.1271.3.4.17.2.1 |
cienaWsXcvrPluggableGroupConformance Group Unknown .1.3.6.1.4.1.1271.3.4.17.2.1.1 |
cienaWsXcvrPluggableCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.1271.3.4.17.2.2 |
cienaWsXcvrPluggableComplianceCompliance Unknown .1.3.6.1.4.1.1271.3.4.17.2.2.1 |
cwsXcvrAugXcvrPluggableVendorIdTableNone SEQUENCE OF CwsXcvrAugXcvrPluggableVendorIdEntry .1.3.6.1.4.1.1271.3.4.17.3 |
cwsXcvrAugXcvrPluggableVendorIdEntryEntry for cwsXcvrAugXcvrPluggableVendorIdTable. CwsXcvrAugXcvrPluggableVendorIdEntry .1.3.6.1.4.1.1271.3.4.17.3.1 |
cwsXcvrPluggableVendorIdRevisionComplianceRevision Compliance flags, as defined in documentation for Common Management Interface, SFF-8636, table 6-3.ro Enumeration .1.3.6.1.4.1.1271.3.4.17.3.1.1 |
cwsXcvrPluggableVendorOuiTableFree side device vendor IEEE company ID. Defined in Common Management Interface, SFF-8636, table 6-15. 3 bytes of data. SEQUENCE OF CwsXcvrPluggableVendorOuiEntry .1.3.6.1.4.1.1271.3.4.17.4 |
cwsXcvrPluggableVendorOuiEntryEntry for cwsXcvrPluggableVendorOuiTable. CwsXcvrPluggableVendorOuiEntry .1.3.6.1.4.1.1271.3.4.17.4.1 |
cwsXcvrPluggableVendorOuiTableSnmpKeyUnique key for cwsXcvrPluggableVendorOui Integer32 .1.3.6.1.4.1.1271.3.4.17.4.1.1 |
cwsXcvrPluggableVendorOuiFree side device vendor IEEE company ID. Defined in Common Management Interface, SFF-8636, table 6-15. 3 bytes of data.ro Unsigned32 .1.3.6.1.4.1.1271.3.4.17.4.1.2 |
cwsXcvrAugXcvrPluggableDeviceIdTableNone SEQUENCE OF CwsXcvrAugXcvrPluggableDeviceIdEntry .1.3.6.1.4.1.1271.3.4.17.5 |
cwsXcvrAugXcvrPluggableDeviceIdEntryEntry for cwsXcvrAugXcvrPluggableDeviceIdTable. CwsXcvrAugXcvrPluggableDeviceIdEntry .1.3.6.1.4.1.1271.3.4.17.5.1 |
cwsXcvrPluggableDeviceIdIdentifierHuman readable description of Vendor's identifier byte value. Reference SFF-8024, table 4-1ro Enumeration .1.3.6.1.4.1.1271.3.4.17.5.1.1 |
cwsXcvrPluggableDeviceIdIdentifierRawVendor's identifier raw byte value. In the format of a HEX string. Reference SFF-8024, table 4-1ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.5.1.2 |
cwsXcvrPluggableDeviceIdExtendedIdentifierRawVendor's extended identifier raw byte value. In the format of a HEX string. Reference SFF-8436, table 4-1ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.5.1.3 |
cwsXcvrPluggableDeviceIdPowerConsumptionThe class of Power Consumption portion of the extended identifier byte, bit 7 to 6. Reference SFF-8436, section 7.6.2.2ro Enumeration .1.3.6.1.4.1.1271.3.4.17.5.1.4 |
cwsXcvrPluggableDeviceIdCleiCLEI code. If bit4 in extended identifier is set to 1, show the CLEI code. If bit4 in extended identifier is set to 0, 'No CLEI code' will be shown. Reference SFF-8436, section 7.6.2.2 and section 7.6.4ro StringMaxl16 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.5.1.5 |
cwsXcvrPluggableDeviceIdConnectorTypeRawVendor's connector type raw byte value. In the format of a HEX string. Reference SFF-8024, table 4-3ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.5.1.6 |
cwsXcvrAugXcvrPluggableVendorTransmitterTableNone SEQUENCE OF CwsXcvrAugXcvrPluggableVendorTransmitterEntry .1.3.6.1.4.1.1271.3.4.17.6 |
cwsXcvrAugXcvrPluggableVendorTransmitterEntryEntry for cwsXcvrAugXcvrPluggableVendorTransmitterTable. CwsXcvrAugXcvrPluggableVendorTransmitterEntry .1.3.6.1.4.1.1271.3.4.17.6.1 |
cwsXcvrPluggableVendorTransmitterWavelengthWave length value, in nanometers.ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.6.1.1 |
cwsXcvrPluggableVendorTransmitterWavelengthRawRaw byte value of Wavelength, before any multiplier operation is done. In the format of a HEX string.ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.6.1.2 |
cwsXcvrPluggableVendorTransmitterEncodingDescriptionHuman readable description of Device encoding mechanism. Some values may differ depending on if it is 8472 or 8x36. Reference SFF-8024, TABLE 4-2.ro Enumeration .1.3.6.1.4.1.1271.3.4.17.6.1.3 |
cwsXcvrPluggableVendorTransmitterEncodingRawRaw byte value of Device encoding mechanism. Some values may differ depending on if it is 8472 or 8x36. In the format of a HEX string. Reference SFF-8024, TABLE 4-2.ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.6.1.4 |
cwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringTableNone SEQUENCE OF CwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringEntry .1.3.6.1.4.1.1271.3.4.17.7 |
cwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringEntryEntry for cwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringTable. CwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringEntry .1.3.6.1.4.1.1271.3.4.17.7.1 |
cwsXcvrPluggableVendorDiagnosticMonitoringDiagnosticMonitoringTypeRawDisplay the raw byte value of Diagnostic Monitoring Type, in the format of a HEX string. Reference SFF 8472 section 8.8 and table 9.5 for detail.ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.7.1.1 |
cwsXcvrPluggableVendorDiagnosticMonitoringDiagnosticMonitoringImplementedIf Digital diagnostic monitoring is implemented, determined by bit 6 of diagnostic monitoring type. Reference SFF 8472 section 8.8 and table 9.5 for detail.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.7.1.2 |
cwsXcvrPluggableTransceiverCodeTableNone SEQUENCE OF CwsXcvrPluggableTransceiverCodeEntry .1.3.6.1.4.1.1271.3.4.17.8 |
cwsXcvrPluggableTransceiverCodeEntryEntry for cwsXcvrPluggableTransceiverCodeTable. CwsXcvrPluggableTransceiverCodeEntry .1.3.6.1.4.1.1271.3.4.17.8.1 |
cwsXcvrPluggableTransceiverCodeTableSnmpKeyUnique key for cwsXcvrPluggableTransceiverCode Integer32 .1.3.6.1.4.1.1271.3.4.17.8.1.1 |
cwsXcvrPluggableTransceiverCodeSpecificationCompliance10 GbE ethernet, 40 GbE ethernet, and 100 GbE extended specification compliance of the transceiver. In the form of a YANG bit field. Note, the bit field in this node is not mapped with the SFF tables. Reference SFF-8436 table 33 for specification compliance of 10 GbE and 40 GbE Ethernet. Reference SFF-8024, TABLE 4-4 for extended specification compliance of 100 GbE.rw Bits .1.3.6.1.4.1.1271.3.4.17.8.1.2 |
cwsXcvrPluggableTransceiverCodeTransceiverCodeRawSpecification Compliance/Transceiver Code raw byte value. In the format of a HEX string. Reference SFF-8436 table 33 for specification compliancero StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.8.1.3 |
cwsXcvrPluggableDeviceTechnologyTableNone SEQUENCE OF CwsXcvrPluggableDeviceTechnologyEntry .1.3.6.1.4.1.1271.3.4.17.9 |
cwsXcvrPluggableDeviceTechnologyEntryEntry for cwsXcvrPluggableDeviceTechnologyTable. CwsXcvrPluggableDeviceTechnologyEntry .1.3.6.1.4.1.1271.3.4.17.9.1 |
cwsXcvrPluggableDeviceTechnologyTableSnmpKeyUnique key for cwsXcvrPluggableDeviceTechnology Integer32 .1.3.6.1.4.1.1271.3.4.17.9.1.1 |
cwsXcvrPluggableDeviceTechnologyDeviceTechnologyRawDisplay the raw byte value of Device Technology, in the format of a HEX string. Reference SFF 8636 table 6-19.ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.9.1.2 |
cwsXcvrPluggableDeviceTechnologyTransmitterTunableDevice Technology Transmitter tuneable value. Reference SFF 8636 table 6-19, bit 0.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.9.1.3 |
cwsXcvrPluggableDeviceTechnologyMaxCaseTemperatureMaximum Case Temperature. In degrees C.ro Unsigned32 .1.3.6.1.4.1.1271.3.4.17.9.1.4 |
cwsXcvrPluggableOptionsTableNone SEQUENCE OF CwsXcvrPluggableOptionsEntry .1.3.6.1.4.1.1271.3.4.17.10 |
cwsXcvrPluggableOptionsEntryEntry for cwsXcvrPluggableOptionsTable. CwsXcvrPluggableOptionsEntry .1.3.6.1.4.1.1271.3.4.17.10.1 |
cwsXcvrPluggableOptionsTableSnmpKeyUnique key for cwsXcvrPluggableOptions Integer32 .1.3.6.1.4.1.1271.3.4.17.10.1.1 |
cwsXcvrPluggableOptionsOptionsRawRaw byte value of 'options' field. In the format of a HEX string. Reference SFF 8636 table 6-22.ro StringMaxl32 (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.10.1.2 |
cwsXcvrPluggableOptionsTxinpeqautoadaptcapableA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.3 |
cwsXcvrPluggableOptionsTxinpeqfixedprogramsettingA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.4 |
cwsXcvrPluggableOptionsRxoutemfixedprogramsettingA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.5 |
cwsXcvrPluggableOptionsRxoutamfixedprogramsettingA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.6 |
cwsXcvrPluggableOptionsTxCdrLossOfLockFlagA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.7 |
cwsXcvrPluggableOptionsRxCdrLossOfLockFlagA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.8 |
cwsXcvrPluggableOptionsUserEepromPage02hProvidedA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.9 |
cwsXcvrPluggableOptionsAstPage01hProvidedA bit flag in 'options', reference SFF 8636 table 6-22.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.10.1.10 |
cwsXcvrPluggableSupplyVoltageTableNone SEQUENCE OF CwsXcvrPluggableSupplyVoltageEntry .1.3.6.1.4.1.1271.3.4.17.11 |
cwsXcvrPluggableSupplyVoltageEntryEntry for cwsXcvrPluggableSupplyVoltageTable. CwsXcvrPluggableSupplyVoltageEntry .1.3.6.1.4.1.1271.3.4.17.11.1 |
cwsXcvrPluggableSupplyVoltageTableSnmpKeyUnique key for cwsXcvrPluggableSupplyVoltage Integer32 .1.3.6.1.4.1.1271.3.4.17.11.1.1 |
cwsXcvrPluggableSupplyVoltageActualSupply voltage, actual supply voltage in volts (V). Range must be between 0 and 6.55V.ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.11.1.2 |
cwsXcvrPluggableStatusTableNone SEQUENCE OF CwsXcvrPluggableStatusEntry .1.3.6.1.4.1.1271.3.4.17.12 |
cwsXcvrPluggableStatusEntryEntry for cwsXcvrPluggableStatusTable. CwsXcvrPluggableStatusEntry .1.3.6.1.4.1.1271.3.4.17.12.1 |
cwsXcvrPluggableStatusTableSnmpKeyUnique key for cwsXcvrPluggableStatus Integer32 .1.3.6.1.4.1.1271.3.4.17.12.1.1 |
cwsXcvrStatusHighAlarmStatusSupply voltage high alarm status, boolean, true if alarm is raised, false if alarm is not raised.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.12.1.2 |
cwsXcvrStatusLowAlarmStatusSupply voltage low alarm status, boolean, true if alarm is raised, false if alarm is not raised.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.12.1.3 |
cwsXcvrStatusHighWarningStatusSupply voltage high warning status, boolean, true if warning is raised, false if warning is not raised.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.12.1.4 |
cwsXcvrStatusLowWarningStatusSupply voltage low warning status, boolean, true if warning is raised, false if warning is not raised.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.12.1.5 |
cwsXcvrPluggableThresholdTableNone SEQUENCE OF CwsXcvrPluggableThresholdEntry .1.3.6.1.4.1.1271.3.4.17.13 |
cwsXcvrPluggableThresholdEntryEntry for cwsXcvrPluggableThresholdTable. CwsXcvrPluggableThresholdEntry .1.3.6.1.4.1.1271.3.4.17.13.1 |
cwsXcvrPluggableThresholdTableSnmpKeyUnique key for cwsXcvrPluggableThreshold Integer32 .1.3.6.1.4.1.1271.3.4.17.13.1.1 |
cwsXcvrThresholdHighAlarmThresholdSupply voltage high alarm threshold, in volts (V).ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.13.1.2 |
cwsXcvrThresholdLowAlarmThresholdSupply oltage low alarm threshold, in volts (V).ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.13.1.3 |
cwsXcvrThresholdHighWarningThresholdSupply voltage high warning threshold, in volts (V).ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.13.1.4 |
cwsXcvrThresholdLowWarningThresholdSupply voltage low warning threshold, in volts (V).ro Decimal2Dig (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.13.1.5 |
cwsXcvrAugXcvrPluggableChannelDiagnosticsTableNone SEQUENCE OF CwsXcvrAugXcvrPluggableChannelDiagnosticsEntry .1.3.6.1.4.1.1271.3.4.17.14 |
cwsXcvrAugXcvrPluggableChannelDiagnosticsEntryEntry for cwsXcvrAugXcvrPluggableChannelDiagnosticsTable. CwsXcvrAugXcvrPluggableChannelDiagnosticsEntry .1.3.6.1.4.1.1271.3.4.17.14.1 |
cwsXcvrPluggableChannelDiagnosticsTransmitterFaultIf the xcvr channel transmitter has detected a fault.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.14.1.1 |
cwsXcvrPluggableChannelDiagnosticsTxAdaptiveEqFaultIf the xcvr channel Tx Adaptive EQ Fault has detected a fault. Only applicable for QSFP28. For QSFP+, default value of FALSE will be returned.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.1271.3.4.17.14.1.2 |
cwsXcvrPluggableSerdesConfigTableNone SEQUENCE OF CwsXcvrPluggableSerdesConfigEntry .1.3.6.1.4.1.1271.3.4.17.15 |
cwsXcvrPluggableSerdesConfigEntryEntry for cwsXcvrPluggableSerdesConfigTable. CwsXcvrPluggableSerdesConfigEntry .1.3.6.1.4.1.1271.3.4.17.15.1 |
cwsXcvrPluggableSerdesConfigTableSnmpKeyUnique key for cwsXcvrPluggableSerdesConfig Integer32 .1.3.6.1.4.1.1271.3.4.17.15.1.1 |
cwsXcvrSerdesConfigSerdesTxEqNonerw XcvrSerdesTxEq (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.15.1.2 |
cwsXcvrSerdesConfigSerdesRxAmplitudeNonerw XcvrSerdesRxAmplitude (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.15.1.3 |
cwsXcvrSerdesConfigSerdesRxEmphasisNonerw XcvrSerdesRxEmphasis (CIENA-WS-TYPEDEFS-MIB) .1.3.6.1.4.1.1271.3.4.17.15.1.4 |
CIENA-WS-XCVR-PLUGGABLE-MIB Technical Reference Overview
The CIENA-WS-XCVR-PLUGGABLE-MIB SNMP MIB module published by Ciena defines 83 managed OID objects, including 52 scalar/column metrics, 13 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.1271.3.4.17. Key tabular structures include cwsXcvrAugXcvrPluggableChannelDiagnosticsTable, cwsXcvrAugXcvrPluggableDeviceIdTable, cwsXcvrAugXcvrPluggableVendorDiagnosticMonitoringTable, cwsXcvrAugXcvrPluggableVendorIdTable, cwsXcvrAugXcvrPluggableVendorTransmitterTable, cwsXcvrPluggableDeviceTechnologyTable.
Key OID Definitions in CIENA-WS-XCVR-PLUGGABLE-MIB
.1.3.6.1.4.1.1271.3.4.17.14None
.1.3.6.1.4.1.1271.3.4.17.5None
.1.3.6.1.4.1.1271.3.4.17.7None
.1.3.6.1.4.1.1271.3.4.17.3None
.1.3.6.1.4.1.1271.3.4.17.6None
.1.3.6.1.4.1.1271.3.4.17.9None
.1.3.6.1.4.1.1271.3.4.17.10None
.1.3.6.1.4.1.1271.3.4.17.15None
.1.3.6.1.4.1.1271.3.4.17.12None
.1.3.6.1.4.1.1271.3.4.17.11None
.1.3.6.1.4.1.1271.3.4.17.13None
.1.3.6.1.4.1.1271.3.4.17.8None
More MIBs from Ciena
Browse all CienaMIBs →The CIENA-CES-PM MIB module enables monitoring of performance statistics and error counters for Carrier Ethernet Service (CES) circuits on Ciena transport equipment. It provides access to specific PM metrics such as cell loss, delay, and jitter measurements required for Service Level Agreement (SLA) compliance verification.
The CIENA-CES-MPLS-MIB enables management of Multiprotocol Label Switching (MPLS) features and associated performance counters on Ciena LEOS-based Carrier Ethernet Services (CES) platforms. It provides visibility into MPLS session states, label bindings, and traffic statistics for provisioning and fault isolation within Ciena's transport network infrastructure.
The CIENA-WS-PM-MIB module enables SNMP-based retrieval of performance monitoring counters and statistics for Ciena Waveserver optical transport equipment. It specifically tracks operational metrics such as optical power levels, bit error rates, and interface utilization to facilitate network health assessment and fault isolation.
The CIENA-CES-CHASSIS-MIB enables monitoring and configuration of physical chassis attributes, including hardware inventory, slot status, and power supply states, on Ciena Carrier Ethernet Service (CES) platforms via SNMP. It facilitates the generation of chassis-specific traps to alert network operations on hardware failures, module insertions, or environmental threshold violations.
The CIENA-CES-DATAPLANE-MIB provides SNMP-based monitoring and management of the data plane interfaces, traffic statistics, and operational status for the Ciena CN5410 Carrier Ethernet Service platform. It enables administrators to track real-time packet throughput, error counters, and interface states to ensure the integrity of Carrier Ethernet services.
The CIENA-CES-CFM-MIB enables the configuration and monitoring of Connectivity Fault Management (CFM) operations on Ciena Carrier Ethernet Services (CES) platforms, specifically tracking maintenance association (MA) states, continuity check (CCM) message counters, and fault notification events for Layer 2 Ethernet service integrity.