CIENA-CES-CONFIG-MGMT-MIB
The CIENA-CES-CONFIG-MGMT-MIB enables management and monitoring of Carrier Ethernet Service (CES) configuration parameters and associated event notifications on Ciena transport equipment. It facilitates the retrieval of service provisioning states and the reception of alarms regarding CES session integrity and configuration changes.
Imported Objects
Objects
16 total| Object Name |
|---|
cienaCesConfigMgmtMIBThis module defines device configuration information and associated notifications. MODULE-IDENTITY .1.3.6.1.4.1.1271.2.1.36 |
IMPORTSThis module defines device configuration information and associated notifications. Unknown .1.3.6.1.4.1.1271.2.1.36 |
cienaCesConfigMgmtMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.36.1 |
cienaCesConfigMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.36.1.1 |
cienaCesConfigMgmtConfigLastSavedThe date and time of the most recent running configuration save.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.36.1.1.1 |
cienaCesConfigMgmtConfigLastChangedThe date and time of the most recent running configuration change.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.36.1.1.2 |
cienaCesConfigMgmtConfigLastContextThe last context that modified the configuration state.ro CienaCesConfigMgmtContext .1.3.6.1.4.1.1271.2.1.36.1.1.3 |
cienaCesConfigMgmtConfigLastUserThe last user that modified the configuration state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.36.1.1.4 |
cienaCesConfigMgmtConfigLastOriginThe last origin that modified the configuration state such as
an IP address or terminal.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.36.1.1.5 |
cienaCesConfigMgmtMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.36.2 |
cienaCesConfigMgmtMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.36.2.1 |
cienaCesConfigMgmtMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.36.2.2 |
cienaCesConfigMgmtMIBNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.2.36 |
cienaCesConfigMgmtMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.2.36.0 |
cienaCesConfigMgmtConfigSavedNotificationThis notification is sent when the configuration is saved. NOTIFICATION-TYPE .1.3.6.1.4.1.1271.2.2.36.0.1 |
cienaCesConfigMgmtConfigChangeNotificationThis notification is sent when the configuration on the device changes.
A hysteresis mechanism is evaluated before sending in an effort to limit the
number of events generated. This mechanism will send out one notification
when an accumulation rate threshold is crossed. If the context/user/origin
of a configuration change does not match the currently tracked
context/user/origin, then this notification will automatically be sent.
The hysteresis algorithm will then be evaluated based on the new
context/user/origin. NOTIFICATION-TYPE .1.3.6.1.4.1.1271.2.2.36.0.2 |
CIENA-CES-CONFIG-MGMT-MIB Technical Reference Overview
The CIENA-CES-CONFIG-MGMT-MIB SNMP MIB module published by Ciena defines 16 managed OID objects, including 6 scalar/column metrics, 0 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.1271.2.1.36. Monitored SNMP traps/notifications include cienaCesConfigMgmtConfigSavedNotification, cienaCesConfigMgmtConfigChangeNotification.
Key OID Definitions in CIENA-CES-CONFIG-MGMT-MIB
.1.3.6.1.4.1.1271.2.2.36.0.1This notification is sent when the configuration is saved.
.1.3.6.1.4.1.1271.2.2.36.0.2This notification is sent when the configuration on the device changes. A hysteresis mechanism is evaluated before sending in an effort to limit the number of events generated. This mechanism will send out one notification when an accumulation rate threshold is crossed. If the context/user/origin of a configuration change does not match the currently tracked context/user/origin, then this notification will automatically be sent. The hysteresis algorithm will then be evaluated based on the new context/user/origin.
.1.3.6.1.4.1.1271.2.1.36This module defines device configuration information and associated notifications.
.1.3.6.1.4.1.1271.2.1.36.1.1.1The date and time of the most recent running configuration save.
.1.3.6.1.4.1.1271.2.1.36.1.1.2The date and time of the most recent running configuration change.
.1.3.6.1.4.1.1271.2.1.36.1.1.3The last context that modified the configuration state.
.1.3.6.1.4.1.1271.2.1.36.1.1.4The last user that modified the configuration state.
.1.3.6.1.4.1.1271.2.1.36.1.1.5The last origin that modified the configuration state such as an IP address or terminal.
More MIBs from Ciena
Browse all CienaMIBs →The CIENA-CES-PM MIB module enables monitoring of performance statistics and error counters for Carrier Ethernet Service (CES) circuits on Ciena transport equipment. It provides access to specific PM metrics such as cell loss, delay, and jitter measurements required for Service Level Agreement (SLA) compliance verification.
The CIENA-CES-MPLS-MIB enables management of Multiprotocol Label Switching (MPLS) features and associated performance counters on Ciena LEOS-based Carrier Ethernet Services (CES) platforms. It provides visibility into MPLS session states, label bindings, and traffic statistics for provisioning and fault isolation within Ciena's transport network infrastructure.
The CIENA-WS-PM-MIB module enables SNMP-based retrieval of performance monitoring counters and statistics for Ciena Waveserver optical transport equipment. It specifically tracks operational metrics such as optical power levels, bit error rates, and interface utilization to facilitate network health assessment and fault isolation.
The CIENA-CES-CHASSIS-MIB enables monitoring and configuration of physical chassis attributes, including hardware inventory, slot status, and power supply states, on Ciena Carrier Ethernet Service (CES) platforms via SNMP. It facilitates the generation of chassis-specific traps to alert network operations on hardware failures, module insertions, or environmental threshold violations.
The CIENA-CES-DATAPLANE-MIB provides SNMP-based monitoring and management of the data plane interfaces, traffic statistics, and operational status for the Ciena CN5410 Carrier Ethernet Service platform. It enables administrators to track real-time packet throughput, error counters, and interface states to ensure the integrity of Carrier Ethernet services.
The CIENA-CES-CFM-MIB enables the configuration and monitoring of Connectivity Fault Management (CFM) operations on Ciena Carrier Ethernet Services (CES) platforms, specifically tracking maintenance association (MA) states, continuity check (CCM) message counters, and fault notification events for Layer 2 Ethernet service integrity.