CADANT-CMTS-NOTIFICATION-MIB

AI MIB Summary

The CADANT-CMTS-NOTIFICATION-MIB defines SNMP trap notification types for monitoring critical events and fault conditions on C4 Cable Modem Termination Systems (CMTS) hardware. These notifications enable network management systems to receive real-time asynchronous alerts regarding CMTS operational status, interface failures, and system anomalies.

This MIB defines object which are NOTIFICATION-TYPE and used to define the SNMP Traps generated from C4 CMTS.
Main OID:
cadNotificationMib.1.3.6.1.4.1.4998.1.1.6.1
17
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

17 total
Object Name
cadNotificationMibThis MIB defines object which are NOTIFICATION-TYPE and used to define the SNMP Traps generated from C4 CMTS.
MODULE-IDENTITY
.1.3.6.1.4.1.4998.1.1.6.1
IMPORTSThis MIB defines object which are NOTIFICATION-TYPE and used to define the SNMP Traps generated from C4 CMTS.
Unknown
.1.3.6.1.4.1.4998.1.1.6.1
cadTrapMibObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.4998.1.1.6.1.1
cadTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4998.1.1.6.1.1.0
aaaServerUnreachableTrapAn event to report that the AAA (RADIUS or TACACS+) server is not responding
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.1
aaaServerGroupUnreachableTrapAn event to report that all the hosts in the AAA (RADIUS or TACACS+) server group are not responding
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.2
aaaServerAuthFailTrapAn event to report that AAA (RADIUS or TACACS+) server rejected the authentication request
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.3
secuLocalAuthFailTrapAn event to report that local password authentication failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.4
secuLineAuthFailTrapAn event to report that line password authentication failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.5
rip2AuthFailTrapAn event to report rip2 authentication failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.6
cadIpdrNoPrimaryCollectorAn event to report IPDR Streaming is enabled but there is no primary collector connected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.7
cadIpdrStreamingDisabledAn event to report IPDR Streaming function has been turned off.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.8
cadIpdrReportCycleMissedAn event to report CMTS was not able to start the scheduled IPDR report cycle session on time. This may be due to system or network load or the lack of primary collector connection.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.9
cadLinkUpThis is to expand standard linkUp trap to include ifDescr. A linkUp trap signifies that the SNMP entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links left the down state and transitioned into some other state (but not into the notPresent state). This other state is indicated by the included value of ifOperStatus.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4998.1.1.6.1.1.0.10
cadTrapsInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.4998.1.1.6.1.1.1
securityInfoThe detail security failure informationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4998.1.1.6.1.1.1.1
ipdrInfoThe detail IPDR failure informationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4998.1.1.6.1.1.1.2