The CADANT-CMTS-NOTIFICATION-MIB defines SNMP trap notification types for monitoring critical events and fault conditions on C4 Cable Modem Termination Systems (CMTS) hardware. These notifications enable network management systems to receive real-time asynchronous alerts regarding CMTS operational status, interface failures, and system anomalies.
This MIB defines object which are NOTIFICATION-TYPE and used to define the SNMP Traps generated from C4 CMTS.
Main OID:
cadNotificationMib.1.3.6.1.4.1.4998.1.1.6.1
17
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
17 total| Object Name |
|---|
cadNotificationMibThis MIB defines object which are NOTIFICATION-TYPE and used to define
the SNMP Traps generated from C4 CMTS. MODULE-IDENTITY .1.3.6.1.4.1.4998.1.1.6.1 |
IMPORTSThis MIB defines object which are NOTIFICATION-TYPE and used to define
the SNMP Traps generated from C4 CMTS. Unknown .1.3.6.1.4.1.4998.1.1.6.1 |
cadTrapMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4998.1.1.6.1.1 |
cadTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4998.1.1.6.1.1.0 |
aaaServerUnreachableTrapAn event to report that the AAA (RADIUS or TACACS+) server is not responding NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.1 |
aaaServerGroupUnreachableTrapAn event to report that all the hosts in the AAA (RADIUS or TACACS+) server
group are not responding NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.2 |
aaaServerAuthFailTrapAn event to report that AAA (RADIUS or TACACS+) server rejected the authentication request NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.3 |
secuLocalAuthFailTrapAn event to report that local password authentication failed NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.4 |
secuLineAuthFailTrapAn event to report that line password authentication failed NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.5 |
rip2AuthFailTrapAn event to report rip2 authentication failed. NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.6 |
cadIpdrNoPrimaryCollectorAn event to report IPDR Streaming is enabled but there is no primary collector connected. NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.7 |
cadIpdrStreamingDisabledAn event to report IPDR Streaming function has been turned off. NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.8 |
cadIpdrReportCycleMissedAn event to report CMTS was not able to start the scheduled IPDR report cycle session on time.
This may be due to system or network load or the lack of primary collector connection. NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.9 |
cadLinkUpThis is to expand standard linkUp trap to include ifDescr.
A linkUp trap signifies that the SNMP entity, acting in an
agent role, has detected that the ifOperStatus object for
one of its communication links left the down state and
transitioned into some other state (but not into the
notPresent state). This other state is indicated by the
included value of ifOperStatus. NOTIFICATION-TYPE .1.3.6.1.4.1.4998.1.1.6.1.1.0.10 |
cadTrapsInfo OBJECT IDENTIFIER .1.3.6.1.4.1.4998.1.1.6.1.1.1 |
securityInfoThe detail security failure informationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4998.1.1.6.1.1.1.1 |
ipdrInfoThe detail IPDR failure informationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4998.1.1.6.1.1.1.2 |