Home/Catalog/BROCADE-VCS-MIB

BROCADE-VCS-MIB

AI MIB Summary

The BROCADE-VCS-MIB provides SNMP monitoring and management capabilities for Brocade VDX switch clusters operating in either Fabric or Logical Chassis modes, exposing metrics for fabric topology, principal switch election status, and inter-switch synchronization states.

The MIB module for the monitoring of VCS fabrics. VCS fabrics is a proprietary technology of Brocade. A VCS fabric consists of a set of inter-connected Brocade VDX switches. These set of switches together behave like a single L2 switch to the outside world. The cluster can operate in 2 modes: fabric mode and Logical chassis mode. In fabric mode, the switches together behave like a single L2 switch - but configuration on each switch is independent of the other. In logical chassis mode, one switch in the fabric is elected as the principal switch. All configurations need to be done only from the principal switch. This is synced across to all the switches in the fabric. Thus the configuration information is the same on all the switches.
Main OID:
brocadeVcsMIB.1.3.6.1.4.1.1588.3.1.6
27
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

27 total
Object Name
brocadeVcsMIB
MODULE-IDENTITY
.1.3.6.1.4.1.1588.3.1.6
brocadeVcsMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.6.1
vcsConfigModero
VcsConfigMode
.1.3.6.1.4.1.1588.3.1.6.1.1
vcsModeOfOperationro
VcsOperationMode
.1.3.6.1.4.1.1588.3.1.6.1.2
vcsIdentifierro
VcsIdentifier
.1.3.6.1.4.1.1588.3.1.6.1.3
vcsVirtualIpV4Addressro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.1588.3.1.6.1.4
vcsVirtualIpV6Addressro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.1588.3.1.6.1.5
vcsVirtualIpAssociatedRbridgeIdro
VcsRbridgeId
.1.3.6.1.4.1.1588.3.1.6.1.6
vcsVirtualIpInterfaceIdro
Unsigned32
.1.3.6.1.4.1.1588.3.1.6.1.7
vcsVirtualIpV4OperStatusro
Enumeration
.1.3.6.1.4.1.1588.3.1.6.1.8
vcsVirtualIpV6OperStatusro
Enumeration
.1.3.6.1.4.1.1588.3.1.6.1.9
vcsNumNodesInClusterro
Unsigned32
.1.3.6.1.4.1.1588.3.1.6.1.10
vcsClusterConditionro
VcsClusterCondition
.1.3.6.1.4.1.1588.3.1.6.1.11
vcsFabricIslTable
SEQUENCE OF VcsFabricIslEntry
.1.3.6.1.4.1.1588.3.1.6.1.12
vcsFabricIslEntry
VcsFabricIslEntry
.1.3.6.1.4.1.1588.3.1.6.1.12.1
vcsFabricIslIndex
Unsigned32
.1.3.6.1.4.1.1588.3.1.6.1.12.1.1
vcsFabricIslIntfNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1588.3.1.6.1.12.1.2
vcsFabricIslNbrIntfNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1588.3.1.6.1.12.1.3
vcsFabricIslNbrWWNro
FcWwn (Brocade-TC)
.1.3.6.1.4.1.1588.3.1.6.1.12.1.4
vcsFabricIslNbrNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1588.3.1.6.1.12.1.5
vcsFabricIslBWro
Unsigned32 UNITS "megabytes"
.1.3.6.1.4.1.1588.3.1.6.1.12.1.6
vcsFabricIslIsTrunkro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.1588.3.1.6.1.12.1.7
brocadeVcsMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.6.2
brocadeVcsConformanceGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.6.2.1
brocadeVcsObjectsGroup
Unknown
.1.3.6.1.4.1.1588.3.1.6.2.1.1
brocadeVcsCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.6.2.2
brocadeVcsCompliance
Unknown
.1.3.6.1.4.1.1588.3.1.6.2.2.1

BROCADE-VCS-MIB Technical Reference Overview

The BROCADE-VCS-MIB SNMP MIB module published by Brocade defines 27 managed OID objects, including 20 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.1588.3.1.6. Key tabular structures include vcsFabricIslTable.

Key OID Definitions in BROCADE-VCS-MIB

brocadeVcsMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.1588.3.1.6

The MIB module for the monitoring of VCS fabrics. VCS fabrics is a proprietary technology of Brocade. A VCS fabric consists of a set of inter-connected Brocade VDX switches. These set of switches together behave like a single L2 switch to the outside world. The cluster can operate in 2 modes: fabric mode and Logical chassis mode. In fabric mode, the switches together behave like a single L2 switch - but configuration on each switch is independent of the other. In logical chassis mode, one switch in the fabric is elected as the principal switch. All configurations need to be done only from the principal switch. This is synced across to all the switches in the fabric. Thus the configuration information is the same on all the switches.

vcsFabricIslTableSEQUENCEnot-accessible
.1.3.6.1.4.1.1588.3.1.6.1.12

This table contains all the ISLs (Inter Switch Link) on the local device.

brocadeVcsComplianceunknownnot-accessible
.1.3.6.1.4.1.1588.3.1.6.2.2.1

The compliance information for this MIB.

brocadeVcsObjectsGroupunknownnot-accessible
.1.3.6.1.4.1.1588.3.1.6.2.1.1

The MIB objects related to VCS monitoring.

vcsClusterConditionVcsClusterConditionread-only
.1.3.6.1.4.1.1588.3.1.6.1.11

The condition of the cluster as a whole.

vcsConfigModeVcsConfigModeread-only
.1.3.6.1.4.1.1588.3.1.6.1.1

The configuration mode of this cluster that is in effect.

vcsIdentifierVcsIdentifierread-only
.1.3.6.1.4.1.1588.3.1.6.1.3

The unique identifier of this cluster.

vcsModeOfOperationVcsOperationModeread-only
.1.3.6.1.4.1.1588.3.1.6.1.2

The operational mode of this cluster.

vcsNumNodesInClusterUnsigned32read-only
.1.3.6.1.4.1.1588.3.1.6.1.10

The number of switches in the cluster that are currently online.

vcsVirtualIpAssociatedRbridgeIdVcsRbridgeIdread-only
.1.3.6.1.4.1.1588.3.1.6.1.6

The rbridge-id of the switch that hosts the virtual IP address.

vcsVirtualIpInterfaceIdUnsigned32read-only
.1.3.6.1.4.1.1588.3.1.6.1.7

The interface Id that is configured in the case of inband configuration. If it is not inband configuration, then this object will contain the value 0.

vcsVirtualIpV4AddressInetAddressread-only
.1.3.6.1.4.1.1588.3.1.6.1.4

The virtual IPv4 address of the cluster. Management stations can use this address to send requests.

vcsVirtualIpV4OperStatusINTEGERread-only
.1.3.6.1.4.1.1588.3.1.6.1.8

The operational status of the virtual IPv4 address.

vcsVirtualIpV6AddressInetAddressread-only
.1.3.6.1.4.1.1588.3.1.6.1.5

The virtual IPv6 address of the cluster. Management stations can use this address to send requests.

vcsVirtualIpV6OperStatusINTEGERread-only
.1.3.6.1.4.1.1588.3.1.6.1.9

The operational status of the virtual IPv6 address.

vcsFabricIslBWUnsigned32read-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.6

The band-width of this ISL.

vcsFabricIslEntryVcsFabricIslEntrynot-accessible
.1.3.6.1.4.1.1588.3.1.6.1.12.1

Represents a single Inter Switch Link (ISL) on this switch.

vcsFabricIslIndexUnsigned32not-accessible
.1.3.6.1.4.1.1588.3.1.6.1.12.1.1

A unique id to distinguish this ISL from others on the local device.

vcsFabricIslIntfNameDisplayStringread-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.2

The interface name (ifName) of the interface on which the ISL is formed on this switch.

vcsFabricIslIsTrunkTruthValueread-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.7

An indication whether this ISL is a trunk interface. A value of true(1) means it is a trunk. A value of false(2) means it is not a trunk.

vcsFabricIslNbrIntfNameDisplayStringread-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.3

The interface name (ifName) of the interface on the neighboring switch for this ISL.

vcsFabricIslNbrNameDisplayStringread-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.5

The name of the neighboring switch on which this ISL is formed.

vcsFabricIslNbrWWNFcWwnread-only
.1.3.6.1.4.1.1588.3.1.6.1.12.1.4

The World Wide Name (WWN) of the neighboring switch for this ISL.

More MIBs from Brocade

Browse all BrocadeMIBs →
SW-MIB

SW-MIB provides management and monitoring capabilities for Brocade Fibre Channel switches, exposing critical operational metrics such as port status, traffic counters, buffer credits, and fabric topology state. This module enables the collection of performance data and fault detection for storage area network (SAN) infrastructure via SNMP.

249 objects→
BROCADE-SYSTEM-MIB

The BROCADE-SYSTEM-MIB provides standard SNMP access to Brocade Fibre Channel and Ethernet switch system-level attributes, including device identity, hardware status, environmental sensors, and operational counters. It enables centralized monitoring of critical infrastructure health metrics such as temperature, fan status, power supply states, and system uptime across the Brocade SAN and LAN fabric.

82 objects→
LINK-INCIDENT-MIB

The LINK-INCIDENT-MIB module monitors FICON link incident and failure events for host and device connections to Brocade Fibre Channel switches within Fabos environments. It provides specific counters and status indicators to track link stability and fault conditions for FICON traffic traversing the switch fabric.

81 objects→
BROCADE-MPLS-MIB

The BROCADE-MPLS-MIB enables monitoring and management of Multi-Protocol Label Switching (MPLS) operational states and traffic statistics on Extreme Networks (formerly Brocade) routing platforms. It provides access to specific metrics including MPLS label forwarding table entries, LSP (Label Switched Path) status, and associated interface counters for troubleshooting label-switched network performance.

65 objects→
BROCADE-TMSTATS-MIB

The BROCADE-TMSTATS-MIB module provides SNMP access to performance counters and operational statistics for Brocade Traffic Manager (TM) hardware and software components, specifically monitoring data plane throughput, packet processing rates, buffer utilization, and traffic flow metrics.

53 objects→
BROCADE-ACL-MIB

The BROCADE-ACL-MIB enables SNMP-based configuration and monitoring of Access Control List (ACL) policies on Brocade Fibre Channel and Ethernet switches, specifically tracking rule definitions, hit counts, and packet drop statistics to enforce network segmentation and security.

49 objects→