BROCADE-SYSTEM-MIB
The BROCADE-SYSTEM-MIB provides standard SNMP access to Brocade Fibre Channel and Ethernet switch system-level attributes, including device identity, hardware status, environmental sensors, and operational counters. It enables centralized monitoring of critical infrastructure health metrics such as temperature, fan status, power supply states, and system uptime across the Brocade SAN and LAN fabric.
Imported Objects
Objects
81 total| Object Name |
|---|
swTrapsV2 OBJECT IDENTIFIER .1.3.6.1.4.1.1588.2.1.1.1.0 |
swFCPortScn NOTIFICATION-TYPE .1.3.6.1.4.1.1588.2.1.1.1.0.3 |
swEventTrap NOTIFICATION-TYPE .1.3.6.1.4.1.1588.2.1.1.1.0.4 |
swStateChangeTrap NOTIFICATION-TYPE .1.3.6.1.4.1.1588.2.1.1.1.0.12 |
swSystem MODULE-IDENTITY .1.3.6.1.4.1.1588.2.1.1.1.1 |
swCurrentDatero DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.1 |
swBootDatero DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.2 |
swFWLastUpdatedro DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.3 |
swFlashLastUpdatedro DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.4 |
swBootPromLastUpdatedro DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.5 |
swFirmwareVersionro DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.6 |
swOperStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.7 |
swSsnro DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.10 |
swFlashDLOperStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.11 |
swFlashDLAdmStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.12 |
swBeaconOperStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.18 |
swBeaconAdmStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.19 |
swDiagResultro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.20 |
swNumSensorsro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.1.21 |
swSensorTable SEQUENCE OF SwSensorEntry .1.3.6.1.4.1.1588.2.1.1.1.1.22 |
swSensorEntry SwSensorEntry .1.3.6.1.4.1.1588.2.1.1.1.1.22.1 |
swSensorIndexro SwSensorIndex (Brocade-TC) .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1 |
swSensorTypero Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2 |
swSensorStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3 |
swSensorValuero Integer32 .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4 |
swSensorInforo DisplayString .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5 |
swIDro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.1.24 |
swEtherIPAddressro IpAddress .1.3.6.1.4.1.1588.2.1.1.1.1.25 |
swEtherIPMaskro IpAddress .1.3.6.1.4.1.1588.2.1.1.1.1.26 |
swIPv6Address DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1588.2.1.1.1.1.29 |
swIPv6Status Enumeration .1.3.6.1.4.1.1588.2.1.1.1.1.30 |
swFabric OBJECT IDENTIFIER .1.3.6.1.4.1.1588.2.1.1.1.2 |
swVfIdro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.2.15 |
swFCport OBJECT IDENTIFIER .1.3.6.1.4.1.1588.2.1.1.1.6 |
swFCPortTable SEQUENCE OF SwFCPortEntry .1.3.6.1.4.1.1588.2.1.1.1.6.2 |
swFCPortEntry SwFCPortEntry .1.3.6.1.4.1.1588.2.1.1.1.6.2.1 |
swFCPortIndexro SwPortIndex (Brocade-TC) .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1 |
swFCPortTypero Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2 |
swFCPortPhyStatero Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3 |
swFCPortOpStatusro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4 |
swFCPortAdmStatusrw Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5 |
swFCPortLinkStaterw Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.6 |
swFCPortTxTypero Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.7 |
swFCPortTxWordsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.11 |
swFCPortRxWordsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.12 |
swFCPortTxFramesro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.13 |
swFCPortRxFramesro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.14 |
swFCPortRxC2Framesro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.15 |
swFCPortRxC3Framesro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.16 |
swFCPortRxLCsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.17 |
swFCPortRxMcastsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.18 |
swFCPortTooManyRdysro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.19 |
swFCPortNoTxCreditsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.20 |
swFCPortRxEncInFrsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21 |
swFCPortRxCrcsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22 |
swFCPortRxTruncsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.23 |
swFCPortRxTooLongsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.24 |
swFCPortRxBadEofsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.25 |
swFCPortRxEncOutFrsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26 |
swFCPortRxBadOsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.27 |
swFCPortC3Discardsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.28 |
swFCPortMcastTimedOutsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.29 |
swFCPortTxMcastsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.30 |
swFCPortLipInsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.31 |
swFCPortLipOutsro Counter32 .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.32 |
swFCPortLipLastAlparo OCTET STRING .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.33 |
swFCPortWwnro OCTET STRING .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.34 |
swFCPortSpeedrw Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.35 |
swFCPortNamero DisplayString .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36 |
swFCPortSpecifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.37 |
swFCPortFlagro FcPortFlag .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.38 |
swFCPortBrcdTypero Enumeration .1.3.6.1.4.1.1588.2.1.1.1.6.2.1.39 |
swEvent OBJECT IDENTIFIER .1.3.6.1.4.1.1588.2.1.1.1.8 |
swEventTable SEQUENCE OF SwEventEntry .1.3.6.1.4.1.1588.2.1.1.1.8.5 |
swEventEntry SwEventEntry .1.3.6.1.4.1.1588.2.1.1.1.8.5.1 |
swEventIndexro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.1 |
swEventTimeInforo DisplayString .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.2 |
swEventLevelro Enumeration .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.3 |
swEventRepeatCountro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.4 |
swEventDescrro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.5 |
swEventVfIdro Integer32 .1.3.6.1.4.1.1588.2.1.1.1.8.5.1.6 |
BROCADE-SYSTEM-MIB Technical Reference Overview
The BROCADE-SYSTEM-MIB SNMP MIB module published by Brocade defines 81 managed OID objects, including 67 scalar/column metrics, 3 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.1588.2.1.1.1.1. Key tabular structures include swEventTable, swFCPortTable, swSensorTable. Monitored SNMP traps/notifications include swEventTrap, swFCPortScn, swStateChangeTrap.
Key OID Definitions in BROCADE-SYSTEM-MIB
.1.3.6.1.4.1.1588.2.1.1.1.1The MIB module is for system information. Copyright (c) 1996-2003 Brocade Communications Systems, Inc. All rights reserved.
.1.3.6.1.4.1.1588.2.1.1.1.8.5The table of event entries.
.1.3.6.1.4.1.1588.2.1.1.1.6.2A table that contains, one entry for each switch port, configuration and service parameters of the port.
.1.3.6.1.4.1.1588.2.1.1.1.1.22The table of sensor entries.
.1.3.6.1.4.1.1588.2.1.1.1.0.4This trap is generated when an event whose level at or below swEventTrapLevel occurs.
.1.3.6.1.4.1.1588.2.1.1.1.0.3This trap is sent whenever an FC port operational status or its type changed. The events that trigger this trap are port goes to online/offline, port type changed to E-port/F-port/FL-port. swFCPortName and swSsn are optional varbind in the trap PDU.swSsn is optional varbind sent when swExtTrap is also enabled.swVfId is optional if VF is enabled.
.1.3.6.1.4.1.1588.2.1.1.1.0.12This trap is sent whenever switch state changes to online/offline
.1.3.6.1.4.1.1588.2.1.1.1.1.19The desired status of the switch beacon. When the beacon is set to on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is set to off, each LED will be in its regular status indicating color and state.
.1.3.6.1.4.1.1588.2.1.1.1.1.18The current operational status of the switch beacon. When the beacon is on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off, each LED will be in their its regular status indicating color and state.
.1.3.6.1.4.1.1588.2.1.1.1.1.2The date and time when the system last booted, in displayable textual format.
.1.3.6.1.4.1.1588.2.1.1.1.1.5The information indicates the date when the boot PROM was last updated, in displayable textual format.
.1.3.6.1.4.1.1588.2.1.1.1.1.1The current date information in displayable textual format.
.1.3.6.1.4.1.1588.2.1.1.1.1.20The result of the power-on startup (POST) diagnostics.
.1.3.6.1.4.1.1588.2.1.1.1.1.25The IP Address of the Ethernet interface of this logical switch.
.1.3.6.1.4.1.1588.2.1.1.1.1.26The IP Mask of the Ethernet interface of this logical switch.
.1.3.6.1.4.1.1588.2.1.1.1.1.3The information indicates the date when the firmware was last updated, in displayable textual format.
.1.3.6.1.4.1.1588.2.1.1.1.1.6The current version of the firwmare.
.1.3.6.1.4.1.1588.2.1.1.1.1.12The state of the FLASH. o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgrade(2) means that the firmware in the FLASH is to be upgraded from the host specified; o swCfUpload(3) means that the switch config file is to be uploaded to the host specified; or o swCfDownload(4) means that the switch config file is to be downloaded from the host specified. o swFwCorrupted(5) state indicates that the firmware in the FLASH is corrupted. This value is for informational purpose only. However, set of swFlashDLAdmStatus to this value is not allowed. The host is specified in swFlashDLHost.0. In addition, user name is specified in swFlashDLUser.0, and the file name specified in swFlashDLFile.0. Reference the user manual on the following commands, o firmwareDownload, o configUpload, and o configDownload.
.1.3.6.1.4.1.1588.2.1.1.1.1.11The operational status of the FLASH. The operational states are as follow: o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgraded(2) state indicates that it contains the image upgraded from the swFlashDLHost.0.; o swCfUploaded(3) state indicates that the switch configuration file has been uploaded to the host; and o swCfDownloaded(4) state indicates that the switch configuration file has been downloaded from the host. o swFwCorrupted (5) state indicates that the firmware in the FLASH of the switch is corrupted.
.1.3.6.1.4.1.1588.2.1.1.1.1.4The information indicates the date when the FLASH was last updated, in displayable textual format.
.1.3.6.1.4.1.1588.2.1.1.1.1.24The number of the logical switch (0/1).
.1.3.6.1.4.1.1588.2.1.1.1.1.29IPV6 address.
.1.3.6.1.4.1.1588.2.1.1.1.1.30The current status of ipv6 address.
.1.3.6.1.4.1.1588.2.1.1.1.1.21The number of sensors inside the switch.
More MIBs from Brocade
Browse all BrocadeMIBs →SW-MIB provides management and monitoring capabilities for Brocade Fibre Channel switches, exposing critical operational metrics such as port status, traffic counters, buffer credits, and fabric topology state. This module enables the collection of performance data and fault detection for storage area network (SAN) infrastructure via SNMP.
The LINK-INCIDENT-MIB module monitors FICON link incident and failure events for host and device connections to Brocade Fibre Channel switches within Fabos environments. It provides specific counters and status indicators to track link stability and fault conditions for FICON traffic traversing the switch fabric.
The BROCADE-MPLS-MIB enables monitoring and management of Multi-Protocol Label Switching (MPLS) operational states and traffic statistics on Extreme Networks (formerly Brocade) routing platforms. It provides access to specific metrics including MPLS label forwarding table entries, LSP (Label Switched Path) status, and associated interface counters for troubleshooting label-switched network performance.
The BROCADE-TMSTATS-MIB module provides SNMP access to performance counters and operational statistics for Brocade Traffic Manager (TM) hardware and software components, specifically monitoring data plane throughput, packet processing rates, buffer utilization, and traffic flow metrics.
The BROCADE-ACL-MIB enables SNMP-based configuration and monitoring of Access Control List (ACL) policies on Brocade Fibre Channel and Ethernet switches, specifically tracking rule definitions, hit counts, and packet drop statistics to enforce network segmentation and security.
The BROCADE-OPTICAL-MONITORING-MIB enables SNMP-based monitoring of Brocade optical transceivers to track critical physical layer parameters including temperature, transmit power, receive power, and laser bias current. This module facilitates real-time health assessment and fault detection for fiber optic ports by exposing these analog sensor values for network management systems.