The BROCADE-OPTICAL-MONITORING-MIB enables SNMP-based monitoring of Brocade optical transceivers to track critical physical layer parameters including temperature, transmit power, receive power, and laser bias current. This module facilitates real-time health assessment and fault detection for fiber optic ports by exposing these analog sensor values for network management systems.

This MIB module supports monitoring of port optics for parameters like, temperature, Tx Power, Rx Power, Tx Bias Current, etc.,.
Main OID:
brocadeOpticalMonitoringMIB.1.3.6.1.4.1.1588.3.1.8
38
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

38 total
Object Name
brocadeOpticalMonitoringMIBThis MIB module supports monitoring of port optics for parameters like, temperature, Tx Power, Rx Power, Tx Bias Current, etc.,.
MODULE-IDENTITY
.1.3.6.1.4.1.1588.3.1.8
bcsiOptMonNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.8.0
bcsiOptMonObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.8.1
bcsiOptMonLaneTableThis table lists the instrumented parameters of all lanes within a 40G Optic of type SR4 and LR4, 100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes per optic, LR10 has 10 lanes per optic.
SEQUENCE OF BcsiOptMonLaneEntry
.1.3.6.1.4.1.1588.3.1.8.1.1
bcsiOptMonLaneEntryOnly the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.
BcsiOptMonLaneEntry
.1.3.6.1.4.1.1588.3.1.8.1.1.1
bcsiOptMonLaneNumThe lane number of this 40G or 100G optic. LR4 and SR4 have 4 lanes per optic. LR10 has 10 lanes per optic.
Unsigned32
.1.3.6.1.4.1.1588.3.1.8.1.1.1.1
bcsiOptMonLaneTemperatureThis object holds the value of the transmitter laser diode temperature for the lane in the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning.ro
SnmpAdminString
.1.3.6.1.4.1.1588.3.1.8.1.1.1.2
bcsiOptMonLaneTxPowerStatusThis object holds the status of the transmitter optical signal power for the lane in the interface, indicating whether this is normal or an alarm is present.ro
Enumeration
.1.3.6.1.4.1.1588.3.1.8.1.1.1.3
bcsiOptMonLaneTxPowerThis object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.ro
SnmpAdminString
.1.3.6.1.4.1.1588.3.1.8.1.1.1.4
bcsiOptMonLaneTxPowerValThis object holds the value of the transmitter optical signal power for the lane in the interface, measured in microWatt.ro
Unsigned32 UNITS "microWatt"
.1.3.6.1.4.1.1588.3.1.8.1.1.1.5
bcsiOptMonLaneRxPowerStatusThis object holds the status of the receiver optical signal power for the lane in the interface, indicating whether this is normal or an alarm is present.ro
Enumeration
.1.3.6.1.4.1.1588.3.1.8.1.1.1.6
bcsiOptMonLaneRxPowerThis object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.ro
SnmpAdminString
.1.3.6.1.4.1.1588.3.1.8.1.1.1.7
bcsiOptMonLaneRxPowerValThis object holds the value of the receiver optical signal power for the lane in the interface, measured in microWatt.ro
Unsigned32 UNITS "microWatt"
.1.3.6.1.4.1.1588.3.1.8.1.1.1.8
bcsiOptMonLaneTxBiasCurrentTx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm.ro
SnmpAdminString
.1.3.6.1.4.1.1588.3.1.8.1.1.1.9
bcsiOptMonInfoTableThis table lists the instrumented parameters of all optical interfaces.
SEQUENCE OF BcsiOptMonInfoEntry
.1.3.6.1.4.1.1588.3.1.8.1.2
bcsiOptMonInfoEntryOnly the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.
BcsiOptMonInfoEntry
.1.3.6.1.4.1.1588.3.1.8.1.2.1
bcsiOptMonTemperatureThis object holds the value of the transmitter laser diode temperature for the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning. For 100G and 40G optic, this returns the average temperature for all lanes.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.2.1.1
bcsiOptMonTxPowerStatusThis object holds the status of the transmit optical signal power for the interface, indicating whether this is normal or an alarm is present.ro
Enumeration
.1.3.6.1.4.1.1588.3.1.8.1.2.1.2
bcsiOptMonTxPowerThis object holds the value of the transmitter optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G optic, this returns the aggregated Tx Power for all lanes.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.2.1.3
bcsiOptMonTxPowerValThis object holds the value of the transmitter optical signal power for the interface, measured in microWatt. For 100G optic, this returns the aggregated Tx Power for all lanesro
Unsigned32 UNITS "microWatt"
.1.3.6.1.4.1.1588.3.1.8.1.2.1.4
bcsiOptMonRxPowerStatusThis object holds the status of the receiver optical signal power for the interface, indicating whether this is normal or an alarm is present.ro
Enumeration
.1.3.6.1.4.1.1588.3.1.8.1.2.1.5
bcsiOptMonRxPowerThis object holds the value of the receiver optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Rx Power for all lanes.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.2.1.6
bcsiOptMonRxPowerValThis object holds the value of the receiver optical signal power for the interface, measured in microWatt. For 100G and 40G optic, this returns the aggregated Rx Power for all lanesro
Unsigned32 UNITS "microWatt"
.1.3.6.1.4.1.1588.3.1.8.1.2.1.7
bcsiOptMonTxBiasCurrentTx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Tx Bias Current for all lanes.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.2.1.8
bcsiIfMediaInfoTableThis table lists the information of the media device (SFP/XFP/Copper) installed in the physical port. Only the ifIndices of Ethernet ports those are associated with the operational cards will be included in this table.
SEQUENCE OF BcsiIfMediaInfoEntry
.1.3.6.1.4.1.1588.3.1.8.1.3
bcsiIfMediaInfoEntryAn entry in this table. The ifIndices of ethernet interfaces will be used to index this table.
BcsiIfMediaInfoEntry
.1.3.6.1.4.1.1588.3.1.8.1.3.1
bcsiIfMediaTypehe type of the media installed in the physical port.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.3.1.1
bcsiIfMediaVendorNameThe media vendor name, full name of the corporation.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.3.1.2
bcsiIfMediaVersionThe media vendor product version number.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.3.1.3
bcsiIfMediaPartNumberThe media vendor part number.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.3.1.4
bcsiIfMediaSerialNumberThe vendor serial number of the media device.ro
DisplayString
.1.3.6.1.4.1.1588.3.1.8.1.3.1.5
bcsiOptMonConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.8.2
bcsiOptMonCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.8.2.1
bcsiOptMonComplianceThe compliance statement for entities which implement BROCADE-OPTICAL-MONITORING-MIB.
Unknown
.1.3.6.1.4.1.1588.3.1.8.2.1.1
bcsiOptMonGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1588.3.1.8.2.2
bcsiOptMonLaneMonGroupA collection of objects for Optical Lane Monitoring of interface optics.
Unknown
.1.3.6.1.4.1.1588.3.1.8.2.2.1
bcsiOptMonInfoMonGroupA collection of objects for Optical Monitoring of interface optics.
Unknown
.1.3.6.1.4.1.1588.3.1.8.2.2.2
bcsiIfMediaGroupA collection of objects for monitoring media information of interfaces.
Unknown
.1.3.6.1.4.1.1588.3.1.8.2.2.3
BROCADE-OPTICAL-MONITORING-MIB - SNMP MIB Reference | MIBs Explorer