BIANCA-X8000-MIBSYS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for BIANCA-X8000-MIBSYS-MIB.
33
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
33 total| Object Name |
|---|
bintec OBJECT IDENTIFIER .1.3.6.1.4.1.272 |
RFC-1215 Unknown .1.3.6.1.4.1.272 |
bibo OBJECT IDENTIFIER .1.3.6.1.4.1.272.4 |
sys OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17 |
x8 OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.3 |
sysX8Config OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.3.1 |
sysX8ConfigPowerSupply1StateThis variable shows the state of the power supply.ro Enumeration .1.3.6.1.4.1.272.4.17.3.1.1 |
sysX8ConfigPowerSupply1TempThis variable shows the actual power supply temperature
in the unit Celsius.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.2 |
sysX8ConfigPowerSupply1TempAlarmThresholdPower supply 1 temperature threshold.rw INTEGER .1.3.6.1.4.1.272.4.17.3.1.3 |
sysX8ConfigPowerSupply1TempAlarmTrapIf the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds.ro Enumeration .1.3.6.1.4.1.272.4.17.3.1.4 |
sysX8ConfigPowerSupply2StateThis variable show the the state of the power supply.ro Enumeration .1.3.6.1.4.1.272.4.17.3.1.5 |
sysX8ConfigPowerSupply2TempThis variable shows the actual power supply temperature
in the unit Celsius.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.6 |
sysX8ConfigPowerSupply2TempAlarmThresholdPower supply 2 temperature threshold.rw INTEGER .1.3.6.1.4.1.272.4.17.3.1.7 |
sysX8ConfigPowerSupply2TempAlarmTrapIf the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds.ro Enumeration .1.3.6.1.4.1.272.4.17.3.1.8 |
sysX8ConfigFanControlThis variable defines automatic fan control.
In mode 'auto' the fans are automatically adjusted
depending on the current temperature.
In mode 'high' all fans remain at maximum speed.rw Enumeration .1.3.6.1.4.1.272.4.17.3.1.9 |
sysX8ConfigFanVersionThis variable shows the firmware version of
the fan unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.272.4.17.3.1.10 |
sysX8ConfigFan1This variable shows the current turning speed.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.11 |
sysX8ConfigFan2This variable shows the current turning speed.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.12 |
sysX8ConfigFan3This variable shows the current turning speed.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.13 |
sysX8ConfigFan4This variable shows the current turning speed.ro INTEGER .1.3.6.1.4.1.272.4.17.3.1.14 |
sysX8Traps OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.3.2 |
sysX8TrapPowerSupply1MissingThis trap signifies that the power supply 1
has been removed TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.1 |
sysX8TrapPowerSupply1PowerOffThis trap signifies that the power supply 1
has no power-good signal (no power input) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.2 |
sysX8TrapPowerSupply1PowerFailThis trap signifies that the power supply 1
has been in the failure (bad DC output) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.3 |
sysX8TrapPowerSupply1PowerGoodThis trap signifies that the power supply 1
is running (supplying power) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.4 |
sysX8TrapPowerSupply1TempCriticalThis trap signifies that the power supply 1 temperature
raises above the critical alarm-threshold TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.5 |
sysX8TrapPowerSupply1TempOkA normal power supply 1 temperature has been restored. TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.6 |
sysX8TrapPowerSupply2MissingThis trap signifies that the power supply 2
has been removed TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.7 |
sysX8TrapPowerSupply2PowerOffThis trap signifies that the power supply 2
has no power-good signal (no power input) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.8 |
sysX8TrapPowerSupply2PowerFailThis trap signifies that the power supply 2
has been in the failure (bad DC output) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.9 |
sysX8TrapPowerSupply2PowerGoodThis trap signifies that the power supply 2
is running (supplying power) TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.10 |
sysX8TrapPowerSupply2TempCriticalThis trap signifies that the power supply 2 temperature
raises above the critical alarm-threshold TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.11 |
sysX8TrapPowerSupply2TempOkA normal power supply 2 temperature has been restored. TRAP-TYPE .1.3.6.1.4.1.272.4.17.3.2.0.12 |