Home/Catalog/BIANCA-X8000-MIBSYS-MIB

BIANCA-X8000-MIBSYS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for BIANCA-X8000-MIBSYS-MIB.

33
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

33 total
Object Name
bintec
OBJECT IDENTIFIER
.1.3.6.1.4.1.272
RFC-1215
Unknown
.1.3.6.1.4.1.272
bibo
OBJECT IDENTIFIER
.1.3.6.1.4.1.272.4
sys
OBJECT IDENTIFIER
.1.3.6.1.4.1.272.4.17
x8
OBJECT IDENTIFIER
.1.3.6.1.4.1.272.4.17.3
sysX8Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.272.4.17.3.1
sysX8ConfigPowerSupply1StateThis variable shows the state of the power supply.ro
Enumeration
.1.3.6.1.4.1.272.4.17.3.1.1
sysX8ConfigPowerSupply1TempThis variable shows the actual power supply temperature in the unit Celsius.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.2
sysX8ConfigPowerSupply1TempAlarmThresholdPower supply 1 temperature threshold.rw
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.3
sysX8ConfigPowerSupply1TempAlarmTrapIf the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.ro
Enumeration
.1.3.6.1.4.1.272.4.17.3.1.4
sysX8ConfigPowerSupply2StateThis variable show the the state of the power supply.ro
Enumeration
.1.3.6.1.4.1.272.4.17.3.1.5
sysX8ConfigPowerSupply2TempThis variable shows the actual power supply temperature in the unit Celsius.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.6
sysX8ConfigPowerSupply2TempAlarmThresholdPower supply 2 temperature threshold.rw
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.7
sysX8ConfigPowerSupply2TempAlarmTrapIf the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.ro
Enumeration
.1.3.6.1.4.1.272.4.17.3.1.8
sysX8ConfigFanControlThis variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed.rw
Enumeration
.1.3.6.1.4.1.272.4.17.3.1.9
sysX8ConfigFanVersionThis variable shows the firmware version of the fan unit.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.272.4.17.3.1.10
sysX8ConfigFan1This variable shows the current turning speed.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.11
sysX8ConfigFan2This variable shows the current turning speed.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.12
sysX8ConfigFan3This variable shows the current turning speed.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.13
sysX8ConfigFan4This variable shows the current turning speed.ro
INTEGER
.1.3.6.1.4.1.272.4.17.3.1.14
sysX8Traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.272.4.17.3.2
sysX8TrapPowerSupply1MissingThis trap signifies that the power supply 1 has been removed
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.1
sysX8TrapPowerSupply1PowerOffThis trap signifies that the power supply 1 has no power-good signal (no power input)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.2
sysX8TrapPowerSupply1PowerFailThis trap signifies that the power supply 1 has been in the failure (bad DC output)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.3
sysX8TrapPowerSupply1PowerGoodThis trap signifies that the power supply 1 is running (supplying power)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.4
sysX8TrapPowerSupply1TempCriticalThis trap signifies that the power supply 1 temperature raises above the critical alarm-threshold
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.5
sysX8TrapPowerSupply1TempOkA normal power supply 1 temperature has been restored.
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.6
sysX8TrapPowerSupply2MissingThis trap signifies that the power supply 2 has been removed
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.7
sysX8TrapPowerSupply2PowerOffThis trap signifies that the power supply 2 has no power-good signal (no power input)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.8
sysX8TrapPowerSupply2PowerFailThis trap signifies that the power supply 2 has been in the failure (bad DC output)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.9
sysX8TrapPowerSupply2PowerGoodThis trap signifies that the power supply 2 is running (supplying power)
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.10
sysX8TrapPowerSupply2TempCriticalThis trap signifies that the power supply 2 temperature raises above the critical alarm-threshold
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.11
sysX8TrapPowerSupply2TempOkA normal power supply 2 temperature has been restored.
TRAP-TYPE
.1.3.6.1.4.1.272.4.17.3.2.0.12
BIANCA-X8000-MIBSYS-MIB - SNMP MIB Reference | MIBs Explorer