BIANCA-X4000-MIBSYS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for BIANCA-X4000-MIBSYS-MIB.
35
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
35 total| Object Name |
|---|
org OBJECT IDENTIFIER .1.3 |
RFC1155-SMI Unknown .1.3 |
dod OBJECT IDENTIFIER .1.3.6 |
internet OBJECT IDENTIFIER .1.3.6.1 |
private OBJECT IDENTIFIER .1.3.6.1.4 |
enterprises OBJECT IDENTIFIER .1.3.6.1.4.1 |
bintec OBJECT IDENTIFIER .1.3.6.1.4.1.272 |
bibo OBJECT IDENTIFIER .1.3.6.1.4.1.272.4 |
sys OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17 |
x4 OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.2 |
sysX4Config OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.2.1 |
sysX4ConfigLcdBrightnessThis variable allows to control the brightness of the LCD
display. Lower values mean less, higher values mean
more brightness. Zero means no brightness.rw INTEGER .1.3.6.1.4.1.272.4.17.2.1.1 |
sysX4ConfigLcdContrastThis variable allows to control the contrast of the LCD
display. Lower values mean less, higher values mean
more contrast. Zero means factory settings.rw INTEGER .1.3.6.1.4.1.272.4.17.2.1.2 |
sysX4ConfigLcdConfigureThis variable determines whether it is possible to configure
the brick by using the LCD display and the buttons.rw Enumeration .1.3.6.1.4.1.272.4.17.2.1.3 |
sysX4ConfigLcdPinThe PIN is the personal identification number that is needed
for authorisation for display configurations.
It consists solely of digits and must be 4
characters long.
Default Value is '0000'.rw DisplayString .1.3.6.1.4.1.272.4.17.2.1.4 |
sysX4ConfigLcdIdleTimerAfter this time the display screen changes to default screen.
Default Value is 5. If this value is set to 0, change to
defaultscreen is disabledrw INTEGER .1.3.6.1.4.1.272.4.17.2.1.5 |
sysX4ConfigLcdDefaultScreenThis screen will be displayed after the LcdIdleTimer has
elapsed.
Default Value is MainMenu.rw DisplayString .1.3.6.1.4.1.272.4.17.2.1.6 |
sysX4ConfigLcdLanguageChoose your display language.rw DisplayString .1.3.6.1.4.1.272.4.17.2.1.7 |
sysX4ConfigTempUnitThis variable defines the unit of sysX4Config*Temp,
either Celsius or Fahrenheit.ro Enumeration .1.3.6.1.4.1.272.4.17.2.1.8 |
sysX4ConfigMainTempThis variable shows the actual main board temperature measured
in the units Fahrenheit or Celsius.ro INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.9 |
sysX4ConfigMainTempAlarmThresholdsystem mainboard temperature threshold.rw INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.10 |
sysX4ConfigMainTempAlarmTrapIf the system temperature raises above the threshold,
a alarm trap is generated every 60 seconds.ro Enumeration .1.3.6.1.4.1.272.4.17.2.1.11 |
sysX4ConfigMod1TempThis variable shows the actual module sensor1 temperature
in the units Fahrenheit or Celsius.ro INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.12 |
sysX4ConfigMod1TempAlarmThresholdactual module sensor1 temperature threshold.rw INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.13 |
sysX4ConfigMod1TempAlarmTrapIf the actual module sensor1 temperature raises above the threshold,
a alarm trap is generated every 60 seconds.ro Enumeration .1.3.6.1.4.1.272.4.17.2.1.14 |
sysX4ConfigMod2TempThis variable shows the actual module sensor2 temperature
in the units Fahrenheit or Celsius.ro INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.15 |
sysX4ConfigMod2TempAlarmThresholdactual module sensor2 temperature threshold.rw INTEGER (-1000..1000) .1.3.6.1.4.1.272.4.17.2.1.16 |
sysX4ConfigMod2TempAlarmTrapIf the actual module sensor2 temperature raises above the threshold,
a alarm trap is generated every 60 seconds.ro Enumeration .1.3.6.1.4.1.272.4.17.2.1.17 |
sysX4Traps OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.17.2.2 |
sysX4TrapMainTempCriticalThis trap signifies that the system board temperature
raises above the critical alarm-threshold TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.1 |
sysX4TrapMainTempOkNormal system board temperature has been restored. TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.2 |
sysX4TrapMod1TempCriticalThis trap signifies that the actual module (sensor 1)
temperature raises above the critical alarm-threshold TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.3 |
sysX4TrapMod1Temp1OkNormal temperature of actual module (sensor 1)
has been restored. TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.4 |
sysX4TrapMod2TempCriticalThis trap signifies that the actual module (sensor 2)
temperature raises above the critical alarm-threshold TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.5 |
sysX4TrapMod2TempOkNormal temperature of actual module (sensor 2)
has been restored. TRAP-TYPE .1.3.6.1.4.1.272.4.17.2.2.0.6 |