BIANCA-BRICK-TOKEN-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for BIANCA-BRICK-TOKEN-MIB.
30
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
30 total| Object Name |
|---|
org OBJECT IDENTIFIER .1.3 |
RFC1155-SMI Unknown .1.3 |
dod OBJECT IDENTIFIER .1.3.6 |
internet OBJECT IDENTIFIER .1.3.6.1 |
private OBJECT IDENTIFIER .1.3.6.1.4 |
enterprises OBJECT IDENTIFIER .1.3.6.1.4.1 |
bintec OBJECT IDENTIFIER .1.3.6.1.4.1.272 |
bibo OBJECT IDENTIFIER .1.3.6.1.4.1.272.4 |
tokenring OBJECT IDENTIFIER .1.3.6.1.4.1.272.4.11 |
tokenringIfTableThe tokenringIfTable contains information relating to the
interfaces found on the system. Each entry corresponds to
a connected TokenRing interface. Entries can only be added or
deleted by the system.
Creating entries: Entries are created by the system
only when a new TokenRing module is installed.
Deleting entries: Entries are removed by the system
after the appropriate TokenRing module is removed. SEQUENCE OF TokenRingIfEntry .1.3.6.1.4.1.272.4.11.1 |
tokenringIfEntry TokenRingIfEntry .1.3.6.1.4.1.272.4.11.1.1 |
tokenringIfSlotUnique Slot of the TokenRing interface.ro INTEGER .1.3.6.1.4.1.272.4.11.1.1.1 |
tokenringIfStateThe TokenRing adapter initialization statero Enumeration .1.3.6.1.4.1.272.4.11.1.1.2 |
tokenringIfRingRatespeed of the token ring.rw Enumeration .1.3.6.1.4.1.272.4.11.1.1.3 |
tokenringIfEarlyTokenReleaseenable or disable early token release. This feature is only
valid with the 16 Mbps ring raterw Enumeration .1.3.6.1.4.1.272.4.11.1.1.4 |
tokenringIfWrapInterfaceenable or disable the wrap interface option. If enabled the
ring insertion process is omitted and all user-transmit data
appears as receive data.rw Enumeration .1.3.6.1.4.1.272.4.11.1.1.5 |
tokenringIfMtuThe size of the largest datagram which can be
sent/received on the interface, specified in
octets.rw INTEGER .1.3.6.1.4.1.272.4.11.1.1.6 |
tokenringIfOverwritePhysAddressThe interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. This overwrites the address
defined in the adapter PROM.rw PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.272.4.11.1.1.7 |
tokenringIfNAUNThe interface's address of the nearest upstream
neighbour.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.272.4.11.1.1.8 |
tokenringIfLineErrorCount of line errors. This counter is incremented whenever
1) a frame is repeated or copied, and
2) the Error Detected Indicator (EDI) is zero in the incoming
frame, and
3) at least one of the following conditions exists:
a) a code violation between SDEL and EDEL
b) a code violation in a token
c) a FCS errorro Counter .1.3.6.1.4.1.272.4.11.1.1.9 |
tokenringIfBurstErrorCount of burst errors. This counter is incremented whenever
the interface detects the absence of transitions for five
half-bit times between SDEL and EDEL, or EDEL and SDELro Counter .1.3.6.1.4.1.272.4.11.1.1.10 |
tokenringIfAriFciErrorCount of ARI/FCI errors. This counter is incremented whenever
the interface receives an Active Monitor Present (AMP) MAC
frame with the ARI/FCI bit equal to zero and a Standby Monitor
Present (SMP) MAC frame with the ARI/FCI bits equal to zero,
or more than one SMP MAC frame with the ARI/FCI bits equal
to zero, without receiving an intervening AMP MAC frame.ro Counter .1.3.6.1.4.1.272.4.11.1.1.11 |
tokenringIfLostFrameErrorCount of lost frames errors. This counter is incremented
whenever the interface is in transmit (stripping) mode and
fails to receive the end of the frame it transmittedro Counter .1.3.6.1.4.1.272.4.11.1.1.12 |
tokenringIfReceiveCongestionErrorCount of receive congestion errors. This counter is
incremented whenever the interface in the repeat mode
recognizes a frame addressed to it but has no buffer space
to copy the framero Counter .1.3.6.1.4.1.272.4.11.1.1.13 |
tokenringIfFrameCopiedErrorCount of frame copied errors. This counter is incremented
whenever the interface in the receive/repeat mode recognizes
a frame addressed to its specific address but finds the
ARI bits not equal to zeroro Counter .1.3.6.1.4.1.272.4.11.1.1.14 |
tokenringIfTokenErrorCount of token errors. This counter is only active in the
active monitor station. It is incremented when the active
monitor detects an error in the token protocolro Counter .1.3.6.1.4.1.272.4.11.1.1.15 |
tokenringIfDmaBusErrorCount of DMA bus errors. This counter is counts the occurences
of DMA bus errors that do not exceed the specified abort
thresholdsro Counter .1.3.6.1.4.1.272.4.11.1.1.16 |
tokenringIfDmaParityErrorCount of DMA parity errors. This counter counts the occurences
of DMA parity errors that do not exceed the specified abort
thresholdsro Counter .1.3.6.1.4.1.272.4.11.1.1.17 |
tokenringIfSoftErrorCount of soft errors that occur during normal operation. A soft
error is an error condition that temporarily degrades system
performance; however the ring recovers by using the protocols
of the adapter. The adapter counts these errors and can report
them to both the attached product and the ring error monitor.ro Counter .1.3.6.1.4.1.272.4.11.1.1.18 |
tokenringIfSourceRoutingenable or disable source routing. If enabled, a routing
information field is added to the frame sent over this
interface.rw Enumeration .1.3.6.1.4.1.272.4.11.1.1.19 |